IM Inspection Worksheet_11-09-2023_15-47-34INSPECTION WORKSHEET (COMFIN-027640-2023) CC-0081-2023Case Number:Case Module:Permit Management ScheduledInspection Status:Inspection Date: Commercial Final InspectionInspection Type:Inspector:Mark Smith Job Address:Parcel Number:920 State Rte 9 Queensbury, NY 12804 296.17-1-45 Company Name NameContact Type Applicant Excel Engineering Inc Business Name wellNOW Contractor Franco Construction Services LLC Engineer Excel Engineering Inc Granted Permission Queensbury Realty Partners LLC Primary Owner Queensbury Realty Partners LLC Checklist Item CommentsPassed Low flow toilet 1.3 gal/flushing cycle False Handicapped Ramps False Final Survey False Building Inspector Notes False Bldg Access All Sides 20ft Drivable Surface False H/C rear grab bar 36" with 24" to open side False Backflow Preventors where required False Public Toilet Room Handicapped Accessible False Exterior timer for exterior lighting False Hydraulic Elevators: Oil Seperator REQUIRED False Firewalls, 2 Hr, 3 Hr / Fire Dampers / Fire Doors False Handicap parking striping False Boiler/Furnace Enclosurer Fire Ext System False Int/Ext Balusters 4 inch Spacing Platform Decks False Bldg Num or Tenant Address on Bld or Drive False Ramps: 12" extension top & bottom False Attic Access Insulation = Attic R- Value False Individual storage units 5% of each type False Gas Shut-off Exposed & Regulator 12" min abv grd False Water Fountain or Cooler False As-built Septic System Layout Required False Public Sewer Sign-Off False Bollard Protection:4' on ctr/3' abv grd, gas meter False Handicapped Service Counters 34 inch False Gas Furnace Shut Off False 12" beyond top & bottom False Int/Ext Guardrails 42 inch Platform Decks False H/C side & rear grab bars 36" above floor False September 11, 2023 Page 1 of 3 INSPECTION WORKSHEET (COMFIN-027640-2023) Checklist Item CommentsPassed HVAC air balancing report False H/C sinks 34" above floor False Hydraulic Elevators: Non-comb. Plumbing REQUIRED False Wood deck: 2'+ from grade dia bracing required False Low Water Shut Off for Boilers False H/C 18" minimum vertical grab bar False Engineer or Architect Approval False Ramps: 6" or more need handrails False Hot water drain pan to indirect waste False Chimney Rain Cap Installed False Foam in basement/attics covered w/thermal barrier False Oil Furnace Shut-Off at Entrance to Furnace Area False H/C grab bar: 42" side, 12" from center False Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame False Plumbing Vent Through Roof/Roof complete False OK to Issue C/O False Step risers: riser 7" & treads 11"False ¾ Hour Corridor Doors & Closers False Propane Tank: Proper Setback from Prop Line/Struct False Stair rail 34"–38": both sides of stairway False Doors 36 inch wLever Hand Panic Hardware, if req False Final Electrical / Flex Gas Piping Bonded False Jack posts in basement lagged at top and bottom False Attic Access 30 x 20 x 30 (h)False Bottled or cooler water provided False Chimney / B Vent / Direct Vent Location False Handicapped Units False Smoke Vents Or Fan, if required False Attic Access Gasketed False Electronic as-builts False Ramps: 4" toe kick each side of ramp False Relief Valve ,Heat Trap/Water Temp 110 deg or less False H/C vertical grab bar 39" from floor and corner False Blower Door Test False Exits At Grade Or Platform 36 (w) x 44 (l)False Special Inspections False Floor Bathroom Watertight Other Floors Okay False Vestibules for Exit doors greater than 3000 sq. ft False Crawl space/knee wall access insulated & gasketed False CSST/other piping in conduit if buried,if required False Ext Finish /Grade Complete/6 in 10ft or Equivalent False Stockroom /Storage/Receiving/Shipping Room False September 11, 2023 Page 2 of 3 INSPECTION WORKSHEET (COMFIN-027640-2023) Checklist Item CommentsPassed Occupancy sensor lighting control False Universal Symbol of Access displayed False Bollard Protection: 15" footings & 3' below grade False H/C mirrors 40" above floor False Handicapped water cooler installed False Pull down stairs boxed out and insulated False Elevator Operation and Signage Shaft Sealed False HVAC Vent Terminal 10' from Lot Line & Openings False OK to Issue Temporary C/O False Elevator Hoistways Pressurized False Active Listening System and Signage Assembly Space False Handicapped Bath/Parking Lot Signage False Outside Spigots have Air Gap False H/C toilet flush handle on open side False Site Plan Variance required False September 11, 2023 Page 3 of 3