IM Inspection Worksheet_14-09-2023_14-46-09INSPECTION WORKSHEET (BINS-027694-2023) CC-0081-2023Case Number:Case Module:Permit Management 09/14/2023 Partial PassInspection Status:Inspection Date: Building InsulationInspection Type:Inspector:Mark Smith Job Address:Parcel Number:920 State Rte 9 Queensbury, NY 12804 296.17-1-45 Company Name NameContact Type Applicant Excel Engineering Inc Business Name wellNOW Contractor Franco Construction Services LLC Engineer Excel Engineering Inc Granted Permission Queensbury Realty Partners LLC Primary Owner Queensbury Realty Partners LLC Checklist Item CommentsPassed Zip exterior sheathing, nailing & taping True Building Inspector Notes False 9/14/23 partial approval for insulation. - thermal insulation at exterior walls verified. R 21 with vapor barrier - duct work not completed at this time. U Factors = .3 cfm for windows, .5 cfm for doors True Insulation under bow & bay window(s)False Tub Shower R-20 with Vapor Barrier False Exterior wall outlets sealed False All Return Air Hard Duct Work False Duct work sealed properly / No duct tape False Duct Testing Outside Conditioned Space False House Wrap Taped at all Seams False Door / Window Sealed (No Insulation)False Air Seal Outside Penetrations False All Ductwork Sealed Return and Supply False Air Barrier behind Knee Walls False Blower Door Test False Duct Insulation - if required in unheated spaces False 15 min thermal barrier/intumescent paint applied False Combustion Air Supply for Furnace False Window Sealing True Duct Blaster Test for duct work, R-8, unhtd spaces False Permit Card Visible From Road False Proper Vent, Attic Vent False Insulation ResCheck ComCheck True September 14, 2023 Page 1 of 1