IM Inspection Worksheet_14-09-2023_14-46-09INSPECTION WORKSHEET (BINS-027694-2023)
CC-0081-2023Case Number:Case Module:Permit Management
09/14/2023 Partial PassInspection Status:Inspection Date:
Building InsulationInspection Type:Inspector:Mark Smith
Job Address:Parcel Number:920 State Rte 9
Queensbury, NY 12804
296.17-1-45
Company Name NameContact Type
Applicant Excel Engineering Inc
Business Name wellNOW
Contractor Franco Construction Services LLC
Engineer Excel Engineering Inc
Granted Permission Queensbury Realty Partners LLC
Primary Owner Queensbury Realty Partners LLC
Checklist Item CommentsPassed
Zip exterior sheathing, nailing & taping True
Building Inspector Notes False 9/14/23 partial approval for insulation.
- thermal insulation at exterior walls verified. R 21 with vapor
barrier
- duct work not completed at this time.
U Factors = .3 cfm for windows, .5 cfm for doors True
Insulation under bow & bay window(s)False
Tub Shower R-20 with Vapor Barrier False
Exterior wall outlets sealed False
All Return Air Hard Duct Work False
Duct work sealed properly / No duct tape False
Duct Testing Outside Conditioned Space False
House Wrap Taped at all Seams False
Door / Window Sealed (No Insulation)False
Air Seal Outside Penetrations False
All Ductwork Sealed Return and Supply False
Air Barrier behind Knee Walls False
Blower Door Test False
Duct Insulation - if required in unheated spaces False
15 min thermal barrier/intumescent paint applied False
Combustion Air Supply for Furnace False
Window Sealing True
Duct Blaster Test for duct work, R-8, unhtd spaces False
Permit Card Visible From Road False
Proper Vent, Attic Vent False
Insulation ResCheck ComCheck True
September 14, 2023 Page 1 of 1