Loading...
001WASTEWATER SYSTEM DESIGN I / C CO OP _ - D-8< 1 I 20'(W)X30`(L) I �� 1 ABSORPTION �, \ BED, 600 SF I s O II I 1 1 --�- COVERED CONCRETE PORCH ' I p. ggTBACK PATI O NEW 1' I 1250 GALLON 1 I SEPTIC TANK ' EXI5TING 4 BEDRM ' ' HOU5E I I 1 I I GARAGE I 1 , ' 1 1 , DRIVEWAY � AVENUE COOLIDGE- TOWN OF QUEENSBURY BUILDING & CODES DEPT. Reviewed Date. 2' TOWN OF QUEENSBURY BUILDING DEPARTMENT fiance Based on our limited examination, comp with our commentsshall soebf at ons are e construed an WASTEWATER SYSTEM PLAN indicating. the plans full compliance with the uilding Codes of SCALE 10=20't New York State. GRAPHIC SCALE 10 0 5 10 20 40 ( IN F' CON7RACTOR TO FIELD VERIFY LOCA710NS AND DISTANCES THIS IS NOT A FIELD SURVEY. F1►-E G�pY 1/I4 PERK T _ 4' HOUSE. E PVC SOR-35 OR Saf-40 WATERWGHT SLEEVE) & SEAL (TM) 4 NEW 1,250 GALLON CONCRETE SIP71C TANK POL,ETHYLENE EMSION-\ TO GRADE NTH TAMPER RESISTANT ACCESS CODER IF TANK IS GREATER THAN 12' BELOW GRADE (N N-7RAMC AREAS) fr MML COVER TEE BAFFLE 1/b' PER FOOT it ift COVER Aft SLOPE DISiRBUnOM Box 4' EFFLUENT SENER • PVC SDR-35 OR SCH-40 BAFFLE 18 , 21M AGL USE SPEED LEVOF1tS TO ASSUME ALL OUTLETS ARE AT EXACTLY THE SAME ELEVA710M 2, AM DROP t 4' PVC SDR-35 SOW HEADER7 BETIAM INVERTS TO ABSORP71ON FEA 1%8" PER FOOT MIN SLOPE SEPTIC TANK NOTES ALL UNITS SHALL COMPLY KITH THE REQUAD"73 OF THE NEW YORK STATE DEPARTMENT OF HEAL714 AND SHALL BE OF PRECAST CONCRETE AS • MANUFACTURED BY UTOPIA ENTERPRISES OR EQUIVALENT. AA ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE WHERE EXIS7ING SOIL CON017TANS ARE UNSUITA Z CRUSHED STONE SHALL BE PLACED AS NECESSARY 70 ACHIEVE A STABLE BASE • � `. �'• :: •,.; . SFP71C TANKS 04STAUED X TRAFFIC AREAS SHALL BE OF EXTRA HEAVY PRECAST CONCRETE SEP71C TANK GONSTRUC770N DES FOR H-20 WHEEL LOADING. ALL JOINTS MUST BE SEALED MTN BUTYL SEALANT. JOINTS BELOW THE LIQUID LEVEL MUST BE TESTED BEFORE BACKFILUNa SEPTIC TANK DETAIL NTS 4" TOPSOIL COVER 5 FT CENTER TO CENTER (TYP ) ABOVE TOP OF STONE BED, SEED & ESTABLISH Nq — F 8-16" COVER 2" STONE COVER OVER PIPE 6" MIN STONE BELOW PIPE 3/4--1-1/2" WASHED CRUSHED STONE LIMIT OF 20'x3O' STONE BED 20' 4- PVC PERFORATED LATERAL INSTALLED LEVEL, IN BED CONFIGURATION WITH MANIFOLDED ENDS 2.5' TO EC OF BED 4-BEDROOM DESIGN WATER SAVING FIXTURES (1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS) DESIGN FLOW - 110 GPD/BEDROOM SYSTEM DESIGN FLOW - 440 GPD SEPTIC TAW NEW 1250 GAL PRECAST CONCRETE TANK LEACH FIELD -STANDARD PIPE -IN -STONE ABSORPTION BED DESIGN PERCOLATION RATE = 1 MIN 52 SEC /IN APPLIgA710N RATE = 0.90 GPD/SF ABSOIFTION BED AREA REQUIRED = 489 SF 600 SF TOTAL TO BE PROVIDED 20 FT' WIDE BY 30 FT LONG ABSORPTION BED PROPOSED POTABLE WATER FROM MUNICIPAL WATER SYSTEM - FILTER FABRIC MIRAFI 14ON OR EQUAL 2, 7'YP.. _ ir } ,• ,� � 12 TOTAL STONE DEPTH .. ..'."" �.�'ai— l�itil-itii ,. `ice.:..Y�i:!"i.ii'i:i.—�ii.."L'�it4i ii'i�'•!Y"Gi..L"J—ii � � ""i'� " 20 FT WIDE BED �' 2' MINIMUM SEPARATION TO BOUNDARY CONDITION ABSORPTION BED PROFILE NTS 30' ABSORPTION BED PLAN NTS PROPOSED DISTRIBUTION BOX FIDE COPY W/W SYSTEM INSTALLATION NOTES • CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE W►TH THE N.YS DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLA77ON OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS. • AFTER EXCAVATION OF BED TO THE DEPTH REQUIRED, THE WALLS AND FLOOR OF THE BED SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED SECTIONS OF EXCAVATION. • PLACEMENT OF AGGREGATE SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN 774E ABSORPTION TRENCHES • THE PIPE AND STONE SHALL BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER UNSUITABLE CONDITIONS • ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. • DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORP71ON AREA AFTER BED HAS BEEN INSTALLED. • THIS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES AND IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE OR EXTREME ORGANIC LOADING DEVICES SUCH AS JACUZZI TYPE SPAS OR GARBAGE GRINDERS. • ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. SYSTEM MATERIAL SPECIFICATIONS ABSORPTION BED AGGREGATE STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. EFFLUENT SEWER PIPE PIPING TO BE 40 SDR-35 OR SCH-40 PVC. INSTALL Wi774 1/8" PER FOOT MINIMUM SLOPE. FILTER FABRIC FILTER FABRIC 70 BE 4.8 OZ/SY NON -WOVEN SEPARATION FABRIC, TENCATE MIRAFI 14ON OR EQUIVALENT. HOUSE SEWER PIPE PIPING TO BE 4- SDR-35 OR SCHEDULE 40 PVC. INSTALL WITH 1/4- PER FOOT MINIMUM SLOPE. TOPSOIL PLACE 4" MINIMUM TOPSOIL OVER EN7IRE BACKFILL AREA. SEED, MULCH, AND ESTABLISH TURF. FF COPY 302.18-3-35 SEP-0484-2023 Frost, Bruce 103 Cooldidge Ave Residential Septic Alteration Dig %Safely. Newffork ■ can safer. rasa ■ watt „n ft** a Th" ■ RaWPaa no Nwks ■ oy WM car. 800-962.7962 MAP REFERENCE: BASE MAP INFORMATION FROM WARREN COUNTY GIS MAPPING AND FIELD MEASUREMENTS BY CENTER PROJECT SERVICES T3•IC)6= R. CEWER, ,a" L TAX MAP # 302.18-3-35 ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW.