Loading...
002WASTEWATER SYSTEM PLAN SCALE: 1'=20't GRAPHIC SCALE 10 0 5 10 20 40 IN FEET ) CONTRACTOR To FIELD VERIFY LOCATIONS AND DISTANCES THIS IS NOT A FIELD SURVEY. RESS7ANT ACCESS COVER W TANK IS GREATER THAN tr BELOW GRADE (NON-TRAFRC AREAS) 12' ANL COVER 114' PER FOOT Aft SLOPE v +• HOW SENER PVC SOR-35 OR Sp9-4O LIQUIDLEA' WATERTIGHT SLEEVE 18` & SEAL (TVP•) Aft NEW 1,= GALLON CONCRETE SEPTIC TAW 4" TOPSOIL COVER ABOVE TOP OF STONE BED, SEED & ESTABLISH -- F 8-16" COVER 2" STONE COVER OVER PIPE 6" MIN STONE BELOW PIPE 3/4"-1-1/2" WASHED CRUSHED STONE LIMIT OF 20'x30' STONE BED 20' T/D' PER FOOT Ir Aft COVER AM N. SLOPE DISTRIBUTroN BOX 4' URL04T MIER PVC SDR-35 OR SCH-40 4 • L1AFIFLE 2"AIN, USE SPEED LEIELERS TO . ASS ALL OUTLETS ARE AT EXACTLY THE SAME ELEVA71ON 2" WL DROP 4' PVC SOR-35 SOLID HEADER BE711M INVERT 70 ABSORPTION FIELD, 1/$" PER FOOT AMN SLOPE SEPTIC TANK NOTES ALL UNITS SHALL COMPLY WITH THE REQU#WdENTS OF 774E NEW YORK STATE DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS • MANUFACTURED BY UTOPIA ENTERPRISES OR EQUIVALENT. ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STOAC SHALL BE PLACED AS NECESSARY TO ACHIEVE A STABLE BASE • SEP77C TANKS INSTALLED AN TRAFFIC AREAS SHALL BE OF EXTRA HEAVY CONSTRUCTION DESOW FOR H-20 WHEEL LOADING ALL JOINTS MUST BE SEALED W17iH BUTYL SEALANT. JOINTS BELOW THE LIQUID LEVEL MUST BE TESTED BEFORE BACKFiLUNG SEPTIC TANK DETAIL NTS 5 FT CENTER TO CENTER (TIP.) 4" PVC PERFORATED LATERAL INSTALLED LEVEL, IN BED CONFIGURATION WITH MANIFOLDED ENDS 25' TO EL OF BED WASTEWATER SYSTEM DESIGN 4—BEDROOM DESIGN WATER SAVING FIXTURES (1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS) DESIGN FLOW — 110 GPD/BEDROOM SYSTEM DESIGN FLOW — 440 GPD SEP77C TANK NEW 1250 GAL PRECAST CONCRETE TANK „EACH FIELD —STANDARD PIPE —IN -STONE ABSORPTION BED DESIGN PERCOLATION RATE = 1 MIN 52 SEC 4N APPLICATION RATE = 0.90 GPD/SF ABSORPTION BED AREA REQUIRED = 489 SF 600 Sr TOTAL TO BE PROVIDED 20 FT WIDE BY 30 FT LONG ABSORPTION BED PROPOSED POTABLE WATER FROM MUNICIPAL WATER SYSTEM — FILTER FABRIC MIRAFI 14M OR EQUAL 2' TYP. _.r j..,� ♦..-j/��:Z� �-Y-.��.:r .��.�.�_.��-•.:. �.✓..::(r.:•l'Y;.?�"i ..(fin' "'R.J `��Y M 12 TOTAL r 3 ,�•r r� } ra �1..:y , STONE DEPTH i:fiii �'f�� C..T�f-i"i' `Lr� �'�l �Y'�iv.� LWJ�'�iY'�!.':'.G�'!'i'—W^� � G,� f�': "'�•.. 20 FT WIDE BED �' 2' MINIMUM ABSORPTION BED PROFILE NTS 100 30' RECORD DRAWING INSTALLATION DATE: 8131123 INSTALLED BY - SANITARY SEWER SERVICES RECORD DRAWING NOTE: A REPRESENTATIVE OF OUR OFFICE VISITED THE SITE DURING CONSTRUCTION AND IT IS MY OPINION THAT THE SYSTEM IS INSTALLED IN GENERAL CONFORMANCE WITH THE APPROVED PLAN AND THIS RECORD DRAWING. FINAL SURFACE FINISHING AND TURF ESTABLISHMENT REMAINS TO BE COMPLETED. THOMAS CENTER JR., P.E. 912/23 A SEPARA77ON TO BOUNDARY CONDITION PROPOSED DIS77?IBU71ON BOX SITE SOILS DATA TEST PIT TP 1 — 8/31123 BY TOM CENTER, P.E. 0-10" — TOPSOIL 10-36" — LOAMY MEDIUM FINE SAND 36-60" — MEDIUM FINE SAND NO MOTTLING OR GROUNDWATER OBSERVED PERCOLATION TEST PT-1 — 6130123 BY TOM CENTER, P.E. —TEST AT 24 INCHES BELOW GRADE IN A 30 INCH DEEP HOLE STABILIZED PERCOLATION RATE. 1 MINUTES 05 SECONDS W/W SYSTEM INSTALLATION NOTES • CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS. • AFTER EXCAVATION OF BED TO THE DEPTH REQUIRED, THE WALLS AND FLOOR OF THE BED SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED SEC71ONS OF EXCAVATION. • PLACEMENT OF AGGREGATE SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN THE ABSORP71ON TRENCHES • THE PIPE AND STONE SHALL BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER UNSUITABLE CONDITIONS • ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. • DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER BED HAS BEEN INSTALLED. • THIS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES AND IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE OR EXTREME ORGANIC LOADING DEVICES SUCH AS JACUZ21 TYPE SPAS OR GARBAGE GRINDERS • ROOF, FOOTING, GARAGE, CELLAR AND. SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. SYSTEM MATERIAL SPECIFICATIONS ABSORPTION BED AG GREG4TE STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. EFFLUENT SEWER PIPE PIPING TO BE 4" SDR-35 OR SCH-40 PVC. INSTALL WITH 1/8" PER FOOT MINIMUM SLOPE. FILTER FABRIC FILTER FABRIC TO BE 4.8 OZ/SY NON —WOVEN SEPARATION FABRIC, TENCATE MIRAFI 14ON OR EQUIVALENT. HOUSE SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL WITH 1/4" PER FOOT MINIMUM SLOPE. TOPSOIL PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED, MULCH, AND ESTABLISH TURF. AS BUILT SEP 0 7 2023 L�� TAX MAP # 302.18-3-35 ABSORPTION BED PLAN ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL NTS ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. Dig IpSafelye 1 SEPTIC RECORD DRAWING 0912123 HoUffork Cali Be&"You qg 0 ISSUED FOR SEPTIC PERMIT 07130123 ■ Wait The Required Time ■ Oonlim Utift Response No., Revisions Date ■ Respect The Marks 800-962.7962 WASTEWATER SYSTEM PLAN & DETAILS w w - wLemn pmpared for: FROST RESIDENCE 103 COOLIDGE AVENUE MAP REFERENCE: Town of Queensbury, warren County, NY BASE MAP INFORMATION FROq WARREN COUNTY GIS MAPPING AND FIELD MEASUREMENTS BY CENTER Drawn: TRC Checked TRC Scale: NOTED Date: 71412023 PROJECT SERVICES 73 Sheridan Street CENTER Glens Falls, NY 12801 400 PROJECT SERVICES (518) 796-2515 Phone f-wq &° y A f "