Loading...
IM Inspection Worksheet_25-09-2023_12-58-10INSPECTION WORKSHEET (SEP-027916-2023) SEP-0690-2022Case Number:Case Module:Permit Management 09/25/2023 Partial PassInspection Status:Inspection Date: SepticInspection Type:Inspector:Mark Smith Job Address:Parcel Number:20 Burnt Ridge Rd Lake George, NY 12845 239.16-1-19 Company Name NameContact Type Applicant Environmental Design Partnership (EDP) Contractor Moss Capital Group LLC Engineer Environmental Design Partnership (EDP) Granted Permission DAN SLOTE Primary Owner DAN SLOTE Checklist Item CommentsPassed Building Inspector Notes False 8/25/23 partial approval for septic system. -placement of 1250 gallon poly septic tank verified -placement of 1000 gallon pump tank verified.. - placement of 20' x30' raised absorption bed verified. 2' forced main from pump tank verified. items remaining - verify baffles at septic tank. -verify alarm and pump floats at pump tank. - verify grinder pump and alarms at grinder pump are operational. -provide proof of final electrical inspection. -provide final as built drawing from design engineer. - verify final grading at raised bed. 9/25/23 partial approval for septic system. Alarms and floats at both the grinder pump at the house and pump tank at the top of the hill verified baffles at septic tank verified. connection of forced main at septic tank verified. items remaining proof of final electric inspection submit certified as built drawing from design engineer ETU Maintenance Contract provided False Final Electrical False Roof gutters don't discharge over leach field True Waterline separation distance True Building to Tank True 2" forced main Tank to Distribution Box True 2" forced main to raised pressure bed Opening Sealed:True 90% alarm level activates True End Cap True Absorbtion Fields: Total Length True 30' x20'bed system Septic system field above flood plain True Foundation to Tank True Engineer Report and As-Built False September 25, 2023 Page 1 of 2 INSPECTION WORKSHEET (SEP-027916-2023) Checklist Item CommentsPassed Sump pump not connected to septic system True Location of system on property False Inlet & Outlet manholes 12"+ below grade True Type of Water: Municipal / Well Water True lake water supply Separation of Pits False Length of Each Trench True 30' x 20' bed system System Use Status True system approved for use Conforms as per Plot Plan False Size of tank True 1250 gallon septic tank 1000 gallon pump tank Foundation to Absorption False InletOutlet Pipes & Baffles True 50% alarm level activates True September 25, 2023 Page 2 of 2