IM Inspection Worksheet_19-09-2023_10-15-02INSPECTION WORKSHEET (PTI-027646-2023) PT-0568-2023Case Number:Case Module:Permit Management ScheduledInspection Status:Inspection Date: Property Transfer InspectionsInspection Type:Inspector:Mark Smith Job Address:Parcel Number:285 Big Bay Rd Queensbury, NY 12804 316.5-1-1 Company Name NameContact Type Applicant MARIANNE PARRISH Checklist Item CommentsPassed Watertight False Building Inspector Notes False Weather/lack of information/inaccessibility False Maintenance Agrmnt/Srvc contract (required)False Holding tank (if yes, include capacity)False Capacity in gallons False System/components indicate unacceptable False Is there a high water alarm?False Roof gutters don't discharge over leach field False Concrete tank False Temperature (Fahrenheit)False D-box material: concrete or plastic False Baffle & D-box or 45° angle False Apparent structural damage False Effluent filter False Septic inlet cover ext - Req 12"+ below grade False Visible scum layer False Septic tank (include # of tanks)False Number of tank compartments False Capacity of pump tank (gallons)False Plumbing fixtures tested & confirmed False Evidence of a pipe bypassing tank False Holding Tank:verify level rises; cap. w/in 250 gal False Whirlpool tub add 250 gal False System appears undersized/undersized components False Foundation drain(s)False Verify 50% & 90% floats False Speed levers in D-box False Is there evidence of surface water infiltrating False Stormwater False Septic tank for bdrms/whrlpl/grndr w/in 250 gal False Garbage grinder add 250 gal False Tank cover False System appears to have functioned adequately False September 19, 2023 Page 1 of 3 INSPECTION WORKSHEET (PTI-027646-2023) Checklist Item CommentsPassed Engineer's report on ETU False System passes all function testing False Outlet pipe (automatic failure, if yes)False Metal tank (automatic failure)False Does the pump(s) appear to be operating properly?False Surface discharge? (if yes, to where?)False Roof runoff False Septic outlet cover ext - Req 12"+ below grade False Sump pump not connected to septic system False Seepage Pits: Number False Number of drop box(es)False Cesspool (automatic failure, if yes)False Model False Aerobic system False Solids in D-box False On-site as-built req'd before insp is complete False Leaking water fixtures False Outlet baffle False Depth below grade to top of tank False Evidence of prolonged high liquid level False Outflow line invert above leach line invert(s)?False Evidence of liquid above outlet inverts?False Main tank cleanout size and location False Other False Cracked, corroded or deformed?False Water tight tank False Ejector or grinder pump sealed False Are there any obvious electrical shortcomings?False Liquid level AT/ABOVE/BELOW (one) discharge invert False Sand filter False Type False Mound system False Absorption bed False Raised system False Cracked, corroded or deformed?False System needs repairs False Plastic tank False Overflow pipe (automatic failure)False Dosing or pump tank sealed False Water softener not connected to septic system False Other False Access riser? (if yes, depth to cover)False September 19, 2023 Page 2 of 3 INSPECTION WORKSHEET (PTI-027646-2023) Checklist Item CommentsPassed Is tank pumped more than 4x/year?False Test each fixture flow to septic tank False Excavate 18" around,no leach field connected False Pump station extention - Reg 12"+ below grade False Other False As-built provided is accurate False Are both switch and alarm operable?False No treatment tank/other critical component(s)False Absorption field False Recommend upgrade/expand/replace 1+ components False Inlet baffle False Manufacturer False Weather False Sump pump(s)False September 19, 2023 Page 3 of 3