IM Inspection Worksheet_10-10-2023_15-28-30INSPECTION WORKSHEET (RESFINAL-028144-2023)
RC-0752-2022Case Number:Case Module:Permit Management
10/10/2023 PassedInspection Status:Inspection Date:
Residential Final InspectionInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:41 Cottage Hill Rd
Queensbury, NY 12804
301.12-3-22
Company Name NameContact Type
Applicant BRITTANY FLORES
Granted Permission PETE SLUCK
Primary Owner BRITTANY FLORES
Checklist Item CommentsPassed
Low flow toilet 1.3 gal/flushing cycle True
Bathroom Fans, if no window True
3" Plumbing Vent through roof minimum 18 inch True
Final Survey Plot Plan False N/A
Interior privacy/trim/doors/main entrance 36 True
Attic Access Insulation = Attic R- Value True
Gas Shut-off Exposed & Regulator 12" min abv grd True
Inter Connected True
Arc Fault Breaker Habitable Spaces True
Furnace/Hot Water Heater operating True
Fresh Air Intake True
Foam in basement/attics covered w/thermal barrier True
Outside every bedroom area True
Fin Elect; Energy Saving Light Bulbs 90 Percent True
OK to Issue C/O True
4 inch Building Number Address visible from road True
HVAC Vent Terminal 10' from Lot Line & Openings True
Every level, Every bedroom True
Furnace shut-off w/in 30 ft. or w/in line of site True
within 10' of all sleeping areas True
on all levels w/gas appliances (i.e. furnace)True
Relief Valve ,Heat Trap/Water Temp 110 deg or less True
Bathroom / Kitchen Watertight True
Battery backup True
Fresh air supply 3' from grade True
Attic Access 22 x 30 minimum True
Roof Complete / Exterior Finish Complete True
General Comments True for alterations / rehab of home
Smoke Detectors:True
Carbon Monoxide Detectors:True
Plumbing fixtures True
October 10, 2023 Page 1 of 1