Loading...
IM Inspection Worksheet_02-10-2023_15-20-36INSPECTION WORKSHEET (PTI-027982-2023) PT-0568-2023Case Number:Case Module:Permit Management 10/02/2023 FailedInspection Status:Inspection Date: Property Transfer InspectionsInspection Type:Inspector:Mark Smith Job Address:Parcel Number:285 Big Bay Rd Queensbury, NY 12804 316.5-1-1 Company Name NameContact Type Applicant MARIANNE PARRISH Checklist Item CommentsPassed Watertight False Building Inspector Notes False 9/19/23 property transfer inspection not approved. The septic system components list below will need to be exposed in order to complete the inspection. - inlet and out side of the septic tank. - the D box - the seepage pits. Call to reschedule when ready. 10/2/23 property transfer inspection not approved. - the two seepage pits were exposed and observed to be full of effluent. the septic system appears to be failing. flow test was completed and all fixtures flow to the existing 1000 gallon septic tank. Weather/lack of information/inaccessibility False Maintenance Agrmnt/Srvc contract (required)False Holding tank (if yes, include capacity)False Capacity in gallons False System/components indicate unacceptable False Is there a high water alarm?False Roof gutters don't discharge over leach field False Concrete tank False Temperature (Fahrenheit)False D-box material: concrete or plastic False Baffle & D-box or 45° angle False Apparent structural damage False Effluent filter False Septic inlet cover ext - Req 12"+ below grade False Visible scum layer False Septic tank (include # of tanks)False Number of tank compartments False Capacity of pump tank (gallons)False Plumbing fixtures tested & confirmed False Evidence of a pipe bypassing tank False Holding Tank:verify level rises; cap. w/in 250 gal False Whirlpool tub add 250 gal False System appears undersized/undersized components False Foundation drain(s)False October 02, 2023 Page 1 of 3 INSPECTION WORKSHEET (PTI-027982-2023) Checklist Item CommentsPassed Verify 50% & 90% floats False Speed levers in D-box False Is there evidence of surface water infiltrating False Stormwater False Septic tank for bdrms/whrlpl/grndr w/in 250 gal False Garbage grinder add 250 gal False Tank cover False System appears to have functioned adequately False Engineer's report on ETU False System passes all function testing False Outlet pipe (automatic failure, if yes)False Metal tank (automatic failure)False Does the pump(s) appear to be operating properly?False Surface discharge? (if yes, to where?)False Roof runoff False Septic outlet cover ext - Req 12"+ below grade False System needs repairs False Sump pump not connected to septic system False Sand filter False Absorption bed False Outflow line invert above leach line invert(s)?False Overflow pipe (automatic failure)False Depth below grade to top of tank False Evidence of prolonged high liquid level False Access riser? (if yes, depth to cover)False Raised system False Cracked, corroded or deformed?False Evidence of liquid above outlet inverts?False Inlet baffle False Water softener not connected to septic system False Is tank pumped more than 4x/year?False Number of drop box(es)False Recommend upgrade/expand/replace 1+ components False Cracked, corroded or deformed?False Manufacturer False Solids in D-box False Test each fixture flow to septic tank False Other False Pump station extention - Reg 12"+ below grade False Cesspool (automatic failure, if yes)False Are there any obvious electrical shortcomings?False Plastic tank False October 02, 2023 Page 2 of 3 INSPECTION WORKSHEET (PTI-027982-2023) Checklist Item CommentsPassed Type False On-site as-built req'd before insp is complete False Leaking water fixtures False Weather False Seepage Pits: Number False Main tank cleanout size and location False No treatment tank/other critical component(s)False Are both switch and alarm operable?False Mound system False Dosing or pump tank sealed False Water tight tank False Other False Sump pump(s)False Model False Other False Aerobic system False Absorption field False Liquid level AT/ABOVE/BELOW (one) discharge invert False Ejector or grinder pump sealed False Excavate 18" around,no leach field connected False As-built provided is accurate False Outlet baffle False October 02, 2023 Page 3 of 3