IM Inspection Worksheet_02-10-2023_15-20-36INSPECTION WORKSHEET (PTI-027982-2023)
PT-0568-2023Case Number:Case Module:Permit Management
10/02/2023 FailedInspection Status:Inspection Date:
Property Transfer InspectionsInspection Type:Inspector:Mark Smith
Job Address:Parcel Number:285 Big Bay Rd
Queensbury, NY 12804
316.5-1-1
Company Name NameContact Type
Applicant MARIANNE PARRISH
Checklist Item CommentsPassed
Watertight False
Building Inspector Notes False 9/19/23 property transfer inspection not approved. The septic
system components list below will need to be exposed in order to
complete the inspection.
- inlet and out side of the septic tank.
- the D box
- the seepage pits.
Call to reschedule when ready.
10/2/23 property transfer inspection not approved.
- the two seepage pits were exposed and observed to be full of
effluent. the septic system appears to be failing.
flow test was completed and all fixtures flow to the existing 1000
gallon septic tank.
Weather/lack of information/inaccessibility False
Maintenance Agrmnt/Srvc contract (required)False
Holding tank (if yes, include capacity)False
Capacity in gallons False
System/components indicate unacceptable False
Is there a high water alarm?False
Roof gutters don't discharge over leach field False
Concrete tank False
Temperature (Fahrenheit)False
D-box material: concrete or plastic False
Baffle & D-box or 45° angle False
Apparent structural damage False
Effluent filter False
Septic inlet cover ext - Req 12"+ below grade False
Visible scum layer False
Septic tank (include # of tanks)False
Number of tank compartments False
Capacity of pump tank (gallons)False
Plumbing fixtures tested & confirmed False
Evidence of a pipe bypassing tank False
Holding Tank:verify level rises; cap. w/in 250 gal False
Whirlpool tub add 250 gal False
System appears undersized/undersized components False
Foundation drain(s)False
October 02, 2023 Page 1 of 3
INSPECTION WORKSHEET (PTI-027982-2023)
Checklist Item CommentsPassed
Verify 50% & 90% floats False
Speed levers in D-box False
Is there evidence of surface water infiltrating False
Stormwater False
Septic tank for bdrms/whrlpl/grndr w/in 250 gal False
Garbage grinder add 250 gal False
Tank cover False
System appears to have functioned adequately False
Engineer's report on ETU False
System passes all function testing False
Outlet pipe (automatic failure, if yes)False
Metal tank (automatic failure)False
Does the pump(s) appear to be operating properly?False
Surface discharge? (if yes, to where?)False
Roof runoff False
Septic outlet cover ext - Req 12"+ below grade False
System needs repairs False
Sump pump not connected to septic system False
Sand filter False
Absorption bed False
Outflow line invert above leach line invert(s)?False
Overflow pipe (automatic failure)False
Depth below grade to top of tank False
Evidence of prolonged high liquid level False
Access riser? (if yes, depth to cover)False
Raised system False
Cracked, corroded or deformed?False
Evidence of liquid above outlet inverts?False
Inlet baffle False
Water softener not connected to septic system False
Is tank pumped more than 4x/year?False
Number of drop box(es)False
Recommend upgrade/expand/replace 1+ components False
Cracked, corroded or deformed?False
Manufacturer False
Solids in D-box False
Test each fixture flow to septic tank False
Other False
Pump station extention - Reg 12"+ below grade False
Cesspool (automatic failure, if yes)False
Are there any obvious electrical shortcomings?False
Plastic tank False
October 02, 2023 Page 2 of 3
INSPECTION WORKSHEET (PTI-027982-2023)
Checklist Item CommentsPassed
Type False
On-site as-built req'd before insp is complete False
Leaking water fixtures False
Weather False
Seepage Pits: Number False
Main tank cleanout size and location False
No treatment tank/other critical component(s)False
Are both switch and alarm operable?False
Mound system False
Dosing or pump tank sealed False
Water tight tank False
Other False
Sump pump(s)False
Model False
Other False
Aerobic system False
Absorption field False
Liquid level AT/ABOVE/BELOW (one) discharge invert False
Ejector or grinder pump sealed False
Excavate 18" around,no leach field connected False
As-built provided is accurate False
Outlet baffle False
October 02, 2023 Page 3 of 3