Loading...
TAB Report - Hyundai QueensbusryNortheastern Air Quality, Inc. P.O. Box 3271 Albany, New York 12203 (518) 857-3641 HVAC SYSTEMS TESTING: Project:Garvey Hyundai Location:Queensbury, New York Architect: Engineer: Piping: Sheet Metal:Alltek Energy Systems Waterford, New York Date:October 6, 2023 Prepared by:T. Waldorf Air Balance Report RKelley@NortheasternAirQuality.com Page 1 of 6 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 PROJECT: THE FOLLOWING IS A LIST OF STANDARD ABBREVIATIONS WHICH MAY APPEAR IN THIS REPORT: MEANING MEANING A AMPS or AMPERAGE NL NOT LISTED ACH AIR CHANGES PER HOUR NOM NOMINAL AD ACCESS DOOR NOM EFFY NOMINAL EFFICIENCY ADJ ADJUSTABLE NR NOT REQUIRED Ak KINETIC (EFFECTIVE FREE) AREA NS NOT SPECIFIED BG BLAST GATE OBD OPPOSED BLADE DAMPER BHP BRAKE HORSEPOWER OED OPEN END DUCT CALC CALCULATED PF POWER FACTOR CALIBR CALIBRATION or CALIBRATED PH PHASE CD CEILING DIFFUSER Ps STATIC PRESSURE CF CUBIC FEET Pt TOTAL PRESSURE CFM CUBIC FEET PER MINUTE Pv VELOCITY PRESSURE cL CENTERLINE RG RETURN GRILLE CLG CEILING RPM REVOLUTIONS PER MINUTE CR CEILING REGISTER RR RETURN REGISTER CS CIRCUIT SETTER SBD SINGLE BLADE DAMPER CSD CEILING SUPPLY DIFFUSER SD SMOKE CONTROL DAMPER DD DIRECT DRIVE SF SERVICE FACTOR DDC DIRECT DIGITAL CONTROL SMC SHEET METAL CONTRACTOR DISC DISCONNECT SWITCH SP STATIC PRESSURE DISCH DISCHARGE SPS STATIC PRESSURE SENSOR DPR DAMPER SR SUPPLY REGISTER DR PRESSURE DIFFERENTIAL TC TEMPERATURE CONTROL EC END CAP TCC TEMPERATURE CONTROL CONTRACTOR ER EXHAUST REGISTER TCD TEMPERATURE CONTROL DAMPER FL BHP BRAKE HORSEPOWER @ FULL LOAD AMPS TP THERMALLY PROTECTED FLA FULL LOAD AMPS TRAV DUCT TRAVERSE FTR FINNED TUBE RADIATION V VOLTS or VOLTAGE GPM GALLONS PER MINUTE VAR VARIABLE HP HORSEPOWER VBD V-BELT DRIVE LD LINEAR DIFFUSER VD VOLUME DAMPER LF LINEAR FEET (NOMINAL)VEL VELOCITY NA NOT ACCESSIBLE W WATTS or WATTAGE ND NO DAMPER WG WALL GRILLE NDRG NON-DUCTED RETURN GRILLE WMS WIRE MESH SCREEN NG NO GAUGE WR WALL REGISTER NI NOT INSTALLED ZD ZONE DAMPER NIC NOT IN CONTRACT ABBREVIATIONS Garvey Hyundai ABBREVIATION ABBREVIATION Page 2 of 6 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 Project: Date Last Updated: Item #System / Note Description Date Closed By Date Closed 1 All RTU Units OA modules not installed 10/6/2023 2 All RTU Units Gas not turned on, preventing fans from running in high (Heating).10/6/2023 Garvey Hyundai 10/6/2023 Punchlist Page 3 of 6 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 10/6/2023 MOTOR NAME- PLATE VOLTS HERTZ 208 60 208 60 DATA EXT. STATIC PRESSURE VOLTS AMPS BHP (calc.) RPM REMARKS: * NOTE: If P.F. or NOM EFFY are NL, (P.F. x NOM EFFY) = 746Hp/(VAX), where X = 1 if 1 Ph, and 1.73 if 3 Ph T1 - T3 (3 Ph only)-- F.L.A.ACTUAL 0.54 T2 (3 Ph only)2.4 1.8 T3 (3 Ph only)2.3 TOTAL CFM - FAN NL NL DISCHARGE NL 0.33 NL 0.28 OUTSIDE AIR CFM #N/A #N/A #N/A NA TOTAL --0.68 TOTAL CFM - OUTLETS NL 2308 NL 2050 RETURN AIR CFM NL 2300 NL 2000 INLET NL -0.31 NL -0.40 S.F.7.5 -7.5 - -- -- NOM EFFY -- Direct Drive Direct Drive Direct Drive CALCULATED (P.F. x NOM EFFY) * MOTOR SHEAVE STARTER HEATER ELEMENTS 0.82 0.82 BELTS FAN SHEAVE Direct Drive Direct Drive Eco-Blue STYLE FRAME -DD -DD FAN RPM Direct Drive Direct Drive Direct DriveSHEAVE cL DISTANCE TEST DATA DESIGN ACTUAL DESIGN ACTUAL P.F. SERIAL NUMBER:0823P73517 0823P73518 SYSTEM:RTU-Detailing Garage RTU-Sales Floor LOCATION:Roof Roof 2.90 1800 PHASE 3 3 FL AMPS HP 2.90 1800 DATE TESTED:10/6/2023 10/6/2023 MANUFACTURER Eco-Blue AIR MOVEMENT EQUIPMENT TEST SHEET SERVICE:Detailing Garage Sales Floor MANUFACTURER:Carrier Carrier MODEL:48FCEM08A3A5A0A0A0 48FCEM08A3A5A0A0A0 PROJECT:Garvey Hyundai TESTED BY:N. Mailly DATE: 208 208 1.9 208 208 T1 7.5 2.3 7.5 1.7 0.64 T1 - T2 208 208 T2 - T3 (3 Ph only) 0.40 Page 4 Northeastern Air Quality, Inc.GRILLE, REGISTER & DIFFUSER REPORT P.O. Box 3271, Albany, NY 12203-0271 PROJECT: (518) 857-3641 TESTED BY:DATE: REMARKS:1) No Damper DESIGN INITIAL INTERMEDIATE FINAL % OF NO.Location MODEL Ak VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS RTU-Detailing Garage 1 Detailing Garage 26" x 16"NL Hood 769 10/6/23 2 Detailing Garage 26" x 16"NL Hood 769 10/6/23 3 Detailing Garage 26" x 16"NL Hood 770 10/6/23 Total 2,308 10/6/23 Return 4 -14" x 38"3.00 NL 800 2,400 10/6/23 RTU-Sales Floor 5 Sales Floor 27" x 8"NL Hood 293 10/6/23 6 Sales Floor 27" x 8"NL Hood 293 10/6/23 7 Sales Floor 27" x 8"NL Hood 293 10/6/23 8 Sales Floor 27" x 8"NL Hood 293 10/6/23 9 Sales Floor 27" x 8"NL Hood 293 10/6/23 10 Sales Floor 27" x 8"NL Hood 293 10/6/23 11 Sales Floor 27" x 8"NL Hood 292 10/6/23 Total 2,050 10/6/23 Return 12 Sales Floor 32" x 32"2.57 NL 408 1,050 10/6/23 RTU-Mezanine 13 Office Area 14" x 10"0.59 NL 911 534 10/6/23 1 14 Office Area 14" x 10"0.59 NL 554 325 10/6/23 1 15 Office Area 14" x 10"0.59 NL 320 188 10/6/23 1 16 Private Office1 14" x 8"NL Hood 189 10/6/23 17 Private Office 2 14" x 8"NL Hood 246 10/6/23 18 Private Office 3 14" x 10"0.59 NL 344 202 10/6/23 19 Private Office 3 14" x 10"0.59 NL 485 284 10/6/23 20 Electrical Closet 14" x 8"NL Hood 112 10/6/23 Total 2,079 10/6/23 Return 21 Office Area 16" x 16"1.24 NL 420 522 10/6/23 22 Private Office 1 16" x 8"NL Hood 198 10/6/23 23 Private Office 2 16" x 8"NL Hood 277 10/6/23 24 Private Office 3 16" x 16"1.24 NL 284 353 10/6/23 Total 1,350 10/6/23 25 -24" x 24" N. Mailly 10/6/2023 Garvey Hyundai Duct Size Page 5 Northeastern Air Quality, Inc.DUCT TRAVERSE REPORT P.O. Box 3271, Albany, NY 12203-0271 PROJECT: (518) 857-3641 TESTED BY:DATE: REMARKS: System Area % OF NO.Zone or Branch Sq. Ft.VEL CFM VEL CFM SP VEL CFM SP DES DATE REMARKS T-1 RTU-Detailing G.12''x 27''2.25 #VALUE!NS 1,025 2,306 -#VALUE!10/6/23 T-2 RTU-Sales Floor 22''2.64 #VALUE!NS 777 2,050 -#VALUE!10/6/23 Rnd Garvey Hyundai Duct Size DESIGN REQUIRMENT INITIAL FINAL N. Mailly 10/6/2023 Page 6