IM Inspection Worksheet_28-09-2023_11-38-46INSPECTION WORKSHEET (PTI-027985-2023) PT-0138-2023Case Number:Case Module:Permit Management 09/28/2023 PassedInspection Status:Inspection Date: Property Transfer InspectionsInspection Type:Inspector:Mark Smith Job Address:Parcel Number:53 Birch Rd Lake George, NY 12845 289.13-1-31 Company Name NameContact Type Applicant Daphne Sanborn Septic Contractor Morning Star Excavation & Septic Checklist Item CommentsPassed Building Inspector Notes True 5/24/23 property transfer inspection not approved - inlet side of septic tank will need to be exposed - absorption field or seepage pit will need to be exposed, including D box. - a barrier will need to be place in driveway so no cars can park on pump tank or septic tank. Call for recheck when ready. 9/28/23 property transfer inspection approved. -A stone barrier has been placed at the driveway pump tank. - seepage pit was exposed and inspected, a traffic rated access lid was installed. - a new 1000 gallon septic tank was installed and approved at the carriage house. Capacity in gallons True both septic tanks are 1000 gallon Is there a high water alarm?True Roof gutters don't discharge over leach field True Concrete tank True all tanks are pre cast concrete Temperature (Fahrenheit)True 65 degrees Septic inlet cover ext - Req 12"+ below grade True Visible scum layer True Septic tank (include # of tanks)True there are two 1000 gallon septic tanks, one at the house one at the garage. there are two pump tanks. one at the house is approximately 250 gallon, one at the lower drive way is 500 gallon. Capacity of pump tank (gallons)True there are two pump tanks, one is 250 gallon, one is 500 gallon. Plumbing fixtures tested & confirmed True Stormwater True negative Septic tank for bdrms/whrlpl/grndr w/in 250 gal True System passes all function testing True property transfer inspection approved Does the pump(s) appear to be operating properly?True Roof runoff True negative Access riser? (if yes, depth to cover)True all four tanks have access covers at grade as well as the seeepage pit Inlet baffle True As-built provided is accurate True Test each fixture flow to septic tank True fixtures at both the house and garage tested and approved. Liquid level AT/ABOVE/BELOW (one) discharge invert True fluid at discharge level Is tank pumped more than 4x/year?True negative September 28, 2023 Page 1 of 2 INSPECTION WORKSHEET (PTI-027985-2023) Checklist Item CommentsPassed Ejector or grinder pump sealed True Outlet baffle True Weather True sunny Dosing or pump tank sealed True Pump station extention - Reg 12"+ below grade True Leaking water fixtures True negative Water tight tank True September 28, 2023 Page 2 of 2