IM Inspection Worksheet_25-10-2023_13-28-58INSPECTION WORKSHEET (COMFIN-028420-2023)
CC-0374-2023Case Number:Case Module:Permit Management
10/25/2023 FailedInspection Status:Inspection Date:
Commercial Final InspectionInspection Type:Inspector:John O'Brien
Job Address:Parcel Number:1012 State Rte 9
Queensbury, NY 12804
296.13-1-62
Company Name NameContact Type
Applicant Jonathan LaRock
Granted Permission Peter Shabat
Primary Owner Peter Shabat
Checklist Item CommentsPassed
Low flow toilet 1.3 gal/flushing cycle False
Handicapped Ramps False
Final Survey False
Building Inspector Notes False 10/25/23 final commercial inspection not approved, please
address the items listed below and call for recheck.
- Provide proof of final electrical inspection.
- install switch plates at all receptacles, outlet with switch will
need to be moved from kitchen floor and properly fastened.
- Insulation behind walk in coolers need to be cleaned up/
reinstalled.
- cover insulation in ceiling behind walk in coolers, install 22" x 30"
attic access that is insulated equal to ceiling insulation with a
gasket seal.
- install lever type door hardware at all interior doors.
- install cap on open sanitary drain observed in basement.
- several leaks were observed in basement plumbing while
conducting a flow test. Both supply and sanitary drains were
observed to be leaking.
- repair open soffits and holes in the siding as discussed on site.
- complete Fire Marshals items.
- Complete all plumbing work, drain for sink in kitchen not
completed.
Bldg Access All Sides 20ft Drivable Surface False
H/C rear grab bar 36" with 24" to open side False
Backflow Preventors where required False
Public Toilet Room Handicapped Accessible False
Exterior timer for exterior lighting False
Hydraulic Elevators: Oil Seperator REQUIRED False
Firewalls, 2 Hr, 3 Hr / Fire Dampers / Fire Doors False
Handicap parking striping False
Boiler/Furnace Enclosurer Fire Ext System False
Int/Ext Balusters 4 inch Spacing Platform Decks False
Bldg Num or Tenant Address on Bld or Drive False
Ramps: 12" extension top & bottom False
Attic Access Insulation = Attic R- Value False
Individual storage units 5% of each type False
Gas Shut-off Exposed & Regulator 12" min abv grd False
October 25, 2023 Page 1 of 3
INSPECTION WORKSHEET (COMFIN-028420-2023)
Checklist Item CommentsPassed
Water Fountain or Cooler False
As-built Septic System Layout Required False
Public Sewer Sign-Off False
Bollard Protection:4' on ctr/3' abv grd, gas meter False
Handicapped Service Counters 34 inch False
Gas Furnace Shut Off False
12" beyond top & bottom False
Int/Ext Guardrails 42 inch Platform Decks False
H/C side & rear grab bars 36" above floor False
HVAC air balancing report False
H/C sinks 34" above floor False
Hydraulic Elevators: Non-comb. Plumbing REQUIRED False
Wood deck: 2'+ from grade dia bracing required False
Low Water Shut Off for Boilers False
H/C 18" minimum vertical grab bar False
Engineer or Architect Approval False
Ramps: 6" or more need handrails False
Hot water drain pan to indirect waste False
Chimney Rain Cap Installed False
Foam in basement/attics covered w/thermal barrier False
Oil Furnace Shut-Off at Entrance to Furnace Area False
H/C grab bar: 42" side, 12" from center False
Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame False
OK to Issue C/O False
Chimney / B Vent / Direct Vent Location False
HVAC Vent Terminal 10' from Lot Line & Openings False
Attic Access Gasketed False
Jack posts in basement lagged at top and bottom False
Bottled or cooler water provided False
Smoke Vents Or Fan, if required False
Crawl space/knee wall access insulated & gasketed False
Bollard Protection: 15" footings & 3' below grade False
Propane Tank: Proper Setback from Prop Line/Struct False
Universal Symbol of Access displayed False
Final Electrical / Flex Gas Piping Bonded False
Blower Door Test False
Electronic as-builts False
Doors 36 inch wLever Hand Panic Hardware, if req False
CSST/other piping in conduit if buried,if required False
H/C mirrors 40" above floor False
Attic Access 30 x 20 x 30 (h)False
Ext Finish /Grade Complete/6 in 10ft or Equivalent False
October 25, 2023 Page 2 of 3
INSPECTION WORKSHEET (COMFIN-028420-2023)
Checklist Item CommentsPassed
Occupancy sensor lighting control False
Stockroom /Storage/Receiving/Shipping Room False
Step risers: riser 7" & treads 11"False
Vestibules for Exit doors greater than 3000 sq. ft False
Elevator Operation and Signage Shaft Sealed False
Handicapped Bath/Parking Lot Signage False
H/C toilet flush handle on open side False
Exits At Grade Or Platform 36 (w) x 44 (l)False
Floor Bathroom Watertight Other Floors Okay False
Ramps: 4" toe kick each side of ramp False
Active Listening System and Signage Assembly Space False
Relief Valve ,Heat Trap/Water Temp 110 deg or less False
Special Inspections False
Elevator Hoistways Pressurized False
¾ Hour Corridor Doors & Closers False
OK to Issue Temporary C/O False
Plumbing Vent Through Roof/Roof complete False
H/C vertical grab bar 39" from floor and corner False
Handicapped water cooler installed False
Stair rail 34"–38": both sides of stairway False
Outside Spigots have Air Gap False
Handicapped Units False
Pull down stairs boxed out and insulated False
Site Plan Variance required False