IM Inspection Worksheet_26-10-2023_12-53-00INSPECTION WORKSHEET (FRM-028495-2023)
RC-0900-2021Case Number:Case Module:Permit Management
10/26/2023 Partial PassInspection Status:Inspection Date:
Building FramingInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:25 Otter Track
Queensbury, NY 12804
316.14-1-9
Company Name NameContact Type
Applicant Mario Profita
Architect Blackbird Group Architect LLC
Contractor Superior Walls of Upstate NY
Wittig Construction
Granted Permission Wittig Construction
Primary Owner Mario Profita
Maria Lasala
Checklist Item CommentsPassed
Building Inspector Notes False
Insulation under bow & bay window(s)False
Air Seal all Plates and Sills False complete air sealing as discussed
Joist hangers True
Exterior wall outlets sealed False
20 in. (W)True
Draft stopping 1,000 sq. ft. floor trusses False
5.0 sf grade True
Design Professional Sign-off, if required False
24 in. (H)True
Air Seal All Registers at Floor False
Anchor Bolts 6 ft. or less on center True
Ice and water shield 24 inches from wall True
Bath fans connected to exterior vent False
12 O.C.True
Air Sealing all Joints Before Insulation False
Notches Holes Bearing Walls False
5.7 sf above below grade True
>1000 s.f. then firestop must be installed False
Truss Specification Provided False N/A TJI's
Windows Habitable Space Bedrooms False
Metal Strapping for Notches Top Plate False
Bracing Bridging True
Garage portal framing True
Deck (post beam connections hex head bolts)True
Jack Studs Headers True
Jack Posts Main Beams True
Attic Access 22 x 30 minimum True
October 26, 2023 Page 1 of 2
INSPECTION WORKSHEET (FRM-028495-2023)
Checklist Item CommentsPassed
Soffits-Insulation Baffel False
Exterior sheeting nailed properly True
Hurricane Clips/Uplift Screws/Nail Holes Filled True
Permit Card Visible From Road True
Framing True rough framing approved
Headroom 6 ft. 8 in.False