IM Inspection Worksheet_02-11-2023_13-13-07INSPECTION WORKSHEET (PTI-028621-2023)
PT-0692-2023Case Number:Case Module:Permit Management
11/02/2023 PassedInspection Status:Inspection Date:
Property Transfer InspectionsInspection Type:Inspector:John O'Brien
Job Address:Parcel Number:4 Big Bay Rd
Queensbury, NY 12804
316.18-1-1.4
Company Name NameContact Type
Primary Owner Chris Parrish
Checklist Item CommentsPassed
Building Inspector Notes True 11/2/23 Property Transfer Inspection Approved
- Verified that there was a total 5 bedrooms not 6 bedrooms as
stated in RPS and the septic tank capacity is actually 1250 gallons
not 1000 gallons. The septic tank is within 250 gallons of the 1500
gallon required for a 5 bedroom house.
Capacity in gallons True 1250 GALLONS
Concrete tank True
Temperature (Fahrenheit)True 30 degrees
D-box material: concrete or plastic True
Baffle & D-box or 45° angle True
Visible scum layer True
Septic tank (include # of tanks)True
Number of tank compartments True 1
Plumbing fixtures tested & confirmed True
Septic tank for bdrms/whrlpl/grndr w/in 250 gal True - Verified that were 5 bedrooms and the septic tank capacity is
1250 gallons not 1000 gallons.
Tank cover True
System appears to have functioned adequately True
System passes all function testing True
Outflow line invert above leach line invert(s)?True
Depth below grade to top of tank True 12" but recommended access cover
Access riser? (if yes, depth to cover)True 12" or less to finish grade
Inlet baffle True
As-built provided is accurate True
Test each fixture flow to septic tank True
Liquid level AT/ABOVE/BELOW (one) discharge invert True AT
Outlet baffle True
Weather True Clear and Cold
Main tank cleanout size and location True
Evidence of liquid above outlet inverts?True NO
Absorption field True
Leaking water fixtures True
Cracked, corroded or deformed?True
Water tight tank True
November 02, 2023 Page 1 of 1