RC-0752-2022 F ^�
Office Use Only
ADDITION/ALTERATION PERMIT Permit#: VLC-— O Z— 2.02Z
Town of Queensbury APPLICATION Permit Fee:$ 255• ?moo
742 Bay Road,Queensbury,NY 12804
P:518-761-8256 www.queensbury.net Invoice#:
Flood Zone? Y Reviewed : • I
Project Location: Li I C.t7 +i q e 14- i 11 I) A . @,e.e a cl cL
Tax Map ID#: 3 0/, /2 -T, 2-z___ Subdivision Name:
r
PROJECT INFORMATION: - !,
fDEC29202W !'
TYPE: Residential El Commercial, Prop seltift OF C I IFFNI zc P
BUILDING&COL.,.
Single-Family ❑ Two-Family ❑ Multi-Family(#of units_) ❑ Townhouse
El Business Office ❑ Retail ❑ Industrial/Warehouse ❑ Garage (#of cars
❑ Other(describe
ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE:
1st floor: 1st floor: t 74,
2nd floor: 2nd floor:
3rd floor: 3rd floor:
Basement (habitable space): Basement (habitable space):
Total sq ft: Total sq ft:
Scope of work to be done:, ."*u- V.,Z7c =%v -S-`- •0I, `
-1„1 Y6''17 �r/' 1441 ,/yam" C -c4 A4$
c;f) � �,, ��, /2.92 � rocs ; J
41-?...) /Lk 6 eiX Ai)4/7 Ara' /Ve_cd ,3A-yee-;.z fioc-it
mr7/4"; /c,77‘, Fzevt:
/L+ �'tJ� J J l�c7►�_ ��`�� � '�''
Addition/Alteration Application Revised June 2022
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction: $ / 000e
2. Source of Heat (circle one): 13"Gas El Oil El Propane ❑ Solar ❑ Other:
Fireplaces/inserts need a separate Fuel Burning Appliances Chimney Application
3. Are there any structures not shown on the plot plan? ❑I YES NO Explain:
4. Are there any easements on the property? ElYES L�'NO
SITE INFORMATION:
• Is this a corner lot? ❑ YES NO
• Will the grade be changed as a res of the construction? ❑ YES O
• What is the water source? PUBLIC ❑ PRIVATE WELL
• What type of wastewater system is on the parcel? El SEWER RIVATE SEPTIC
DECLARATION:
1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be
completed within a 12 month period.Any changes to the approved plans prior to/during construction will require
the submittal of amended plans, additional reviews and re-approval.
2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of
Queensbury.After 1 year from the initial application date, 100%of the fee is retained.
3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees
and department approval.
4. I certify that the application, plans and supporting materials are a true and a complete statement and/or description
of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws
and ordinances, and in conformance with local zoning regulations.
5. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of
occupancy.
6. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: r�
ICSIGNATURE: DATE: L- L�
Addition/Alteration Application Revised June 2022
CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL
• Applicant:
Name(s):(6 F'
Mailing Address, C/S/Z: �i I C,c.� ;,5 p %� ;OA 1.0, LiNt)e e u
Cell Pho� ( I S ) -7 LA Z1 — °tO 5 Land Line: ( )
Email: `I`7�S(vim l i Z. 0 1-L4 w':,,► I ., C c yV)
• Primary Owner(s):
Name(s):` . 4 - oir‘,l P— EU c (5
Mailing Address, C/S/Z: L1 an ( ,)1 -11c 1
Cell Pho,�n : (j 1,* ) 1 4 H — �Le��i, Land Line: ( )
teic lk/Ea1 1i'V4i � C c✓,'1
lheck if all work will be performed by property owner only
• Contractor(s): (List all additional contractors on the back of this form)
Contact Name(s):
Contractor Trade:
Mailing Address, C/S/Z:
Cell Phone: ( ) Land Line: ( )
Email:
**Workers' Comp documentation must be submitted with this application**
• Architect(s)/Engineer(s):
Business Name:
Contact Name(s):
Mailing Address, C/S/Z:
Cell Phone: ( ) Land Line: ( )
Email:
Contact Person for Compliance in regards to this project: `— 'r oc4C_
Cell Phone: ( ) ' , 7 Land Line: ( )
Email: i�C«��G c�\C�,u6 ,Co-nn
Addition/Alteration Application Revised June 2022
Residential Plan Review: 1- and 2- Family Dwellings
Y/N/)JA (1 of 2)
Two (2)full sets of plans
14 Over 1,500 sq.ft. requires engineering stamp
g /4- Design loads on plans: 115 Wind Floor Loads 40 psf
North of Rte. 149 60) 50 Ground Snow Load Sleeping Areas &Attics 30 psf
Calculations Decks 40 psf
Wind design for lake front properties
Window schedule with glass size & main doors/Air leakage< .5 cfm for doors, < .3 cfm for
windows/Tempered glass in bathrooms
�/ Door schedule/Main entrance 36" door o ` �,�,� ,,_:-;4.Cr
/ Emergency Escape or Bedrooms & Habitable Space cG��
Above-grade: 5.7 sq.ft.
Grade: 5.0 sq.ft.
24" (h)x 20" (w) minimum
44" maximum height above door
t P" Window control devices 24"or less 2nd story or 72" above grade
Egress window from basement 5.0 sq.ft.
._,,4, Floor system sizing per table 502.3.1 , 57/,.h .
,//1-- Residential check ERI or Prescriptive method _1t,E.0 A
A,//1- Driveway length: 300' or more-12'width required/500'or more,turnaround required
/1A- Foundation drainage on plans, if required
�- 6" drop in 10' exterior grade
Framing cross section for each roof line,vertical fire stopping every 10'where
w/. required/joist spans pg. 127
NA- Ice&snow shield-24"from exterior wall
y - Platforms at exterior doors
NA Stairway headroom 6'8"; all stairs 36" width
Stair run and rise
1 Winder run and rise
Spiral stairs meet requirements
't . Smoke detectors—battery backup & proper location, interconnected
Bathroom fixtures—proper clearance
Hall width-36"width
/V/f Handrails more than four risers on open sides
Railing&guards>30"/basement stairs included/closed risers more than 4" in height
f- Safety glazing notes for required areas
Garage fire separation:1A" gable end/5/8" under living space &%" on walls/20 min. door
Alt and closer
Garage floor sloped
I Attic access: gasket seal& R-value equal to roof insulation
t Roof over 30"-22"x 30"/Crawl spaces 18" x 24" access
Continued on back 4
Residential Plan Review Revised October 2021
`.' 9 Load Short Form °b
wri htsoft® Date: Dec 15,2022
Entire House . By: JAY
PETE SLUCK •
. ._ �.F ,-: __;-:ram-- ----- - a �
4.- - __ - . --Akin'
For. PETE SLUCK
8 CONNER DRIVE,S.GLENS FALLS,NY 12983
Design Information
Htg Clg Infiltration
Outside db(°F) -20 93 Method Simplified
Inside db(°F) 72 75 Construction quality Average
Design TD(°F) 92 18 Fireplaces 0
Daily range - M
Inside humidity(%) 50 50
Moisture difference(grub) 57 47 —
HEATING EQUIPMENT COOLING EQUIPMENT •
Make AMERISTAR Make AMERISTAR
Trade Trade
Model A951X040BU4SAB Cond A4AC3024D1000A
AHRI ref Coil 4PXCBU24BS3HAA
AHRI ref
Efficiency 95AFUE Efficiency 0 SEER
Heating input 40000 Btuh Sensible cooling 0 Btuh
Heating output 39000 Btuh Latent cooling 0 Btuh
Temperature rise 59 °F Total cooling 0 Btuh
Actual airflow 600 cfm Actual airflow 800 efin
Airflow factor 0.018 cfrn/Btuh Air flow factor 0.111 cfm/Btuh
Static pressure 0.05 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.79
ROOM NAME Area I Htg load Clg load HtgAVF ClgAVF
(ft2) (Btuh) (Btuh) (cfrn) (cfm)
LMNGROOM 188 11116 2205 202 246
BEDROOM 1 188 7663 1812 139 202
BEDROOM 2 188 7096 1485 129 165
KITCHEN 188 7096 1680 129 187
Entire House d I 750 32971 7182 600 800
Other equip loads 0 0
Equip.@ 0.98 RSM 7024
Latent cooling 1859
TOTALS 750 32971 8883 600 800
Bold/italic values have been manually overridden
Calculations approved byACCA to meet all requirements of Manual J 7th Ed.
wrightsoft� 2022-Dec-1514:50:21
4w4.•a .� Rigt@-Suite®universal2021 21.0.03 RSU09659 Page 1
ACCA Project2.rup Caic=MJ7 Frorl Door faces:N
12/15/22,3:21 PM manual_s
Sizing Calculator based on Manual S
System Type::Straight cool w/gas v Climate: Heating&cooling v Elevation: ft.
Load Calculation Data Sizing Results System Performance at Design Temp
Cooling-Sensible: ;7182 btu's *Cooling-Minimum:9041 btu's Cooling-Sensible: '7182 btu's
( Cooling- Latent: 1859 btu's Cooling-Maximum:10397 btu's Cooling- Latent: :1859 btu's
Cooling-Total: 9041 btu's Heating-Minimum:32971 btu's Heat-Output 32971 btu's
Heating-Total: 32971 btu's Heating-Maximum:46159 btu's J.Totals After Altitude Correction,
Sensible Heat Ratio 0.79 Sensible:7182 Latent:1859 btu's
•
Calculate Heat:32971 Cooling:9041 btu's
Straight Cool w/gas heat
Manufacturer's CFM rating at sea level: 600 CFM required to maintain mass flow rate for elevation: 600
Is system within specs:YES
Clear Load Data I Clear System Data Clear All Data Instructions f Loadcalc Page Balance Point
*Note:The total cooling minimum can be 90%of the total cooling load if the output of the sensible plus 50%of the excess latent equal at least 90%of the sensible
load.If this condition exists the calculator will detect it but in most cases the cooling minmum will equal the total cooling load.
Gas heating output is estimated to be derated 4%per 1000 ft.by altitude
Disclaimer:
lise this online sizing program at your own risk.
This program has not been accredited by any organization and though much time
and elTon has been spent to make it accurate there is no guarantee to its accuracy.
https://www.loadcalc.net/sizing.php 1/1
Submittal
Upflow/ Horizontal Left/Right
Single Stage Condensing
Gas Fired Furnace
80,000 BTUH
Upflow, Convertible to
Horizontal Right or
Horizontal Left - �``
A951X080BU4SAB •
o•
o,y
o�
Note:Graphics in this document are for representation
only.Actual model may differ in appearance.
May 2020 A951 X080 B U-SUB-1 C-EN
0
C
r+
• It_•
11.1111 1.1/11 CD
1.1111
I. 11.1/1 ::�I; o
111 MC
11 UY1[/1 I 1 1.1/11 w/�i,�
SW 0[w I (t1[ Ci/
II./11 I\ I oily 11.1111
rUUt(( OUTLET ‘IF II
gib
AIR I �;w 1.1..Upflow Furnace
I•I/{ I eh
B Size Cabinet =
CC1.1/1 3l1 3.3/4
31.1/1 r•111{ N
111tt10 1011 �I
Ise use n was 11pr Of[0 a wee
1.1/1 qp1j11-v1
0tlra4I lam
1.3/0 1•ln 1431OOR1
�110 1.1/l 1.11/ 0f
[1 01113LL 11Hf --lal1 1.1/0-+ Ca03Y31T[Tt1101.
qq lwllal 11f1r1
I11[11111,[f —L\ l�, Itai 11414 um
1101170YI11/1a11
tgqtnl
(Otn111t 11qq u . IlllliruV It[1
IYaulallt 11111
IA1 IYI[i • { •• p1
IYw110114 11au I Ii0[ppr•[i
I • 11a1111111•[131
q 1.310
fa0[YW[hill11 I.311
Iw/1W1 41[ILR11111
M0031/r 11 11 !0•I/11 11 _ 400000. �lll
• 71•{lll 11.1/1{ 11.111 .
i Rr[3�31111t[1 1111
P. -.•—.. YL
I 31.1/1/ •P•—_
73.11
11 I
u3ra F7, S IDE win SIDE
I14/11 uan
RETURN I• RETURN j
•
III AIR i Tn•Iul 11.111I I AIR i 1/
I.11 L.—.--..- -.. . l 1 _ `. n.i--•---•—•----- 1•In
BII,+i -11.1111�• • .-•I•Il/ll 11.1I/u I•n/n+
r, 3/14/1 001 a11113113 MAT 1110
1.1/11 104/11 L-11/11
tan
11.111(Al
1•3111
1 1•I1/Il
1
Pull 0rol((
r03 rut 0811[I
mall INLET IYolnaul uan uwmu
AIR
> 1l1
cc
tT II.
X
C
i1
c
a
C
(!.
C
a
c-; .
(r
z
Product Specifications
MODEL A951X080BU4SAB(a) MODEL A951X080BU4SAB(a)
TYPE Upflow/Horizontal Gauge(Fired) 20
RATINGS(b) ORIFICES—Main
Input BTUH 80,000 Nat.Gas Qty.—Drill Size 4-45
Capacity BTUH(ICS)co on 77,200 LP Gas Qty.—Drill Size 4-56
Temp.Rise(Min.-Max.) 45-75 GAS VALVE Redundant-One Stage
AFUE(%)(d) 96.0 PILOT SAFETY DEVICE
Return Air Temp.(Min.-Max.) 45°F-80°F Type 120 V SiNi Igniter
BLOWER DRIVE z DIRECT • BURNERS—Type Multipart Inshot
Diameter—Width(In.) 11 X 8 Number 4
No.Used 1 POWER CONN.—V/Ph/Hz(h) 120/1/60
Speeds(No.)(e) 9 Ampacity(In Amps) 11.8
CFM vs.in.w.g. See Fan Performance Max.Overcurrent Protection(Amps) 15
Table
Motor HP 3/4 PIPE CONN.SIZE(in.) 1/2
RPM 1075 DIMENSIONS H x W x D
Volts/Ph/Hz 120/1/60 Uncrated(In.) 34 x 17-1/2 x 28-3/4
FLA 7.6 Crated(In.) 35-1/2 x 19-1/2 x 30-7/8
COMBUSTION FAN—Type Centrifugal WEIGHT
Drive—No.Speeds Direct 1 Shipping(Lbs.)/Net(Lbs.) 135/127
(a) Meets Energy Star
Motor HP—RPM 3300 (b) For U.S.applications,above input ratings(BTUH)are up to 2,000
Volts/Ph/Hz 120/1/60 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above
sea level.For Canadian applications,above input ratings(BTUH)are
FLA 2.14 up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500
feet above sea level.
FILTER—Furnished? No (c) Central Furnace heating designs are certified to ANSI Z21.47/CSA
Type recommended High Velocity 2.3—latest edition.
(d) Based on U.S.government standard tests.
Hi Vel.(No.-Size-Thk.) 1—16x25—1 in. (e) 9 Speed constant torque ECM blower motor
VENT PIPE DIAMETER—Min(in.) CORefer to the Vent Length Table in the Installer's Guide.
(f)(g) 2 Round CO All furnace models have a vent outlet diameter that equals 2 in.
(h) The above wiring specifications are in accordance with National
HEAT EXCHANGER Electrical Code;however,installations must comply with local codes.
Type—Fired 409 Stainless Steel
—Unfired 29-4C Stainless Steel
A951 X080B U-SUB-1 C-E N 3
Airflow tables
Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.)
Model Tap 0.1 0.3 0.5 0.7 0.9
1 SCFM 911 766 622 477 332
Watts 94 104 115 125 136
2 SCFM 1075 963 851 740 628
Watts 139 153 168 182 197
3 SCFM 1215 1121 1028 934 840
Watts 185 202 219 236 253
4 SCFM 1250 1164 1077 990 903
Watts 203 221 239 257 274
5 SCFM 1349 1272 1194 1116 1039
A951X0806U4SAB 251 271 291 310 330
Watts
6 SCFM 1453 1387 1321 1254 1188
Watts 313 335 356 378 400
7 SCFM 1505 1438 1372 1305 1239
Watts 340 362 384 406 427
8 SCFM 1657 1597 1538 1479 1419
Watts 453 477 500 524 547
9 SCFM 1878 1815 1752 1690 1627
Watts 669 686 702 718 735
4 A951 X080BU-SUB-1 C-EN