CC-0024-2023 Office Use Only
ADDITION/ALTERATION PERMIT Permit It: CC—00?1-k••2_02_3
APPLICATION
Tosco ofQuecnsbury Permit Fee:$ 1152 • 5cj
742 Bay Road,Queensbury,NY 12804
P:518-761-8256 www.queensbury.net Invoice#: 5b 1
Flood Zone? Y N / Reviewed By: 16
Project Location: 310 Bay Road -Adirondack Retirement Specialists
Tax Map ID#: 302.8-1-16i Subdivision Name:
PROJECT INFORMATION:
TYPE: El Residential 2 Commercial, Proposed Use: Business Offices
❑ Single-Family ❑ Two-Family 0 Multi-Family(#of units_) ❑ Townhouse
2 Business Office ❑ Retail ❑ Industrial/Warehouse El Garage (#of cars
❑ Other(describe
ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE:
1st floor: 332 SF 1st floor: 2,875 SF
2nd floor: 2nd floor: 86 SF
3rd floor: 3rd floor:
Basement (habitable space): Basement (habitable space):
Total sq ft: 332 SF Total sq ft: 2,961 SF
Scope of work to be done: Addition and replacement of exterior entry porches, interior alterations
to interior office spaces on the first floor and a small section of the second floor offices.
", l E D ! E
_ JAN232023 j
TOWN OF QUEE;•JS3URY
BUILDING & CODES
Addition/Alteration Application Revised June 2022
,
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction: $ 150,000
2. Source of Heat (circle one): 2 Gas 0 Oil ❑ Propane El Solar ❑ Other:
Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application
3. Are there any structures not shown on the plot plan? ❑ YES 2 NO Explain:
4. Are there any easements on the property? ❑ YES 2 NO
SITE INFORMATION:
• Is this a corner lot? ❑ YES 2 NO
• Will the grade be changed as a result of the construction? ❑ YES 2 NO
• What is the water source? 2 PUBLIC ❑ PRIVATE WELL
• What type of wastewater system is on the parcel? .2 SEWER ❑ PRIVATE SEPTIC
DECLARATION:
1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be
completed within a 12 month period.Any changes to the approved plans prior to/during construction will require
the submittal of amended plans,additional reviews and re-approval.
2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of
Queensbury.After 1 year from the initial application date, 100%of the fee is retained.
3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees
and department approval.
4. I certify that the application, plans and supporting materials are a true and a complete statement and/or description
of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws
and ordinances, and in conformance with local zoning regulations.
5. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of
occupancy.
6. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: Ethan P. Hall -Architect\Agent for the Applicant
SIGNATURE: c�A 7Vall DATE: 23 Jan 2023
Addition/Alteration Application Revised June 2022
CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL
• Applicant:
Name(s): Adirondack Retirement Specialists-Adam Mark
Mailing Address, C/S/Z: 351 Bay Road, Queensbury NY 12804
Cell Phone: ( 716 )531-6266 Land Line: '( 518 )761-6184
Email: markam1256agmail.com
• Primary Owner(s):
Name(s): Adirondack Retirement Specialists-Adam Mark
Mailing Address, C/S/Z: 351 Bay Road, Queensbury NY 12804
Cell Phone: ( 716 )531-6266 Land Line: ( 518 )761-6184
Email: markam1256@gmail.com
❑ Check if all work will be performed by property owner only
• Contractor(s): (List all additional contractors on the back of this form)
Contact Name(s): Farr Construction - Brodie Farr
Contractor Trade: General Construction
Mailing Address, C/S/Z: 4 Stonehurst Drive, Queensbury NY 12804
Cell Phone: ( 518 )796-7066 Land Line: (518 )745-5438
Email: farrconstruction23@gmail.com •
**Workers' Comp documentation must be submitted with this application**
• Architect(s)/Engineer(s):
Business Name: Rucinski Hall Architecture
Contact Name(s): Ethan P. Hall
Mailing Address, C/S/Z: 134 Dix Ave, Glens Falls NY 12801
Cell Phone: ( 518 )260-2888 Land Line: ( 518 )741-0268
Email: ephalk nycap.rr.com
Contact Person for Compliance in regards to this project: Ethan P. Hall
Cell Phone: ( 518 )260-2888 Land Line: ( 518 )741-0268
Email: ephall@nycap.rr.com
Addition/Alteration Application Revised June 2022
,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
RUCINSKI HALL ARCHITECTURE
Ronald Richard Rucinski
Ethan Peter Hall
134 Dix Avenue
Glens Falls NY 12801
Voice 518 741-0268
Fax 518 741-0274
Email ephall@nycap.rr.com
Transmittal
To: Mark Smith —Town of Queensbury— Building Department
From: Ethan Hall
Date: 11 November, 2023
Re: Adirondack Retirement Specialists — 310 Bay Road —As-built & acceptance
Mark,
At the above referenced project location this office has made periodic site visits during construction
to witness the work and all changes that have been made during construction have been reviewed
by this office. All work is acceptable to this office and the work has been performed in accordance
with the construction drawings.
If there are any questions please let me know.
Regards,
Ethan P. Hall
Architect
Y:AAdirondack Retirement Specialists\310 Bay Road\Paperwork\Transmittal-11 Nov 2023.doc
��������Q�°��
���� r ��m ��� ~
SECT|ON142O2
ELEVATORS AND LIFTS
Display hidden notes tospecifier. (Oon't know how? Click Here)
Copyright 2008- 20Y7ARCA T, /nc -All rights reserved
PART1. GENERAL
1.1 SECTION INCLUDES
A. Connnnoroio| vvhoo|ohoir lifts.
1.2 RELATED SECTIONS
A. Division 16 Sections for electrical service for elevators to and including disconnect
and fused switches ot machine room.
B. Division 16 Sections for standby power source, transfer switch, and connection from
auxiliary contacts in transfer switch to controller.
C. Division 16 Section "Voice and Data Communication Cabling"for telephone service
to elevators.
O. Section 03300 -Cost-in-P|000 Concrete: Concrete for elevator machine foundation,
and pit.
E. Section 06100 - Rough Carpentry: Hoistway framing, building-in hoistway door
frames and overhead hoist beams.
F. Section OD21O -Wood Doors: Hoishwoydoors.
G. Section OD71O - Door Hardware.
H. Section O02GO -Gypsum Board Assemblies: Gypsum shaft walls.
|. Section 00650 - Resilient Flooring: Floor finish in cab.
J. Section 00686 -Carpet: Floor finish in cab.
K. Section 00000 - Points and Coatings: Interior transparent wood finish in cab.
L. Section 13DSO - Detection and Alarm: Fire and smoke detectors and interconnecting
devices.
1.3 REFERENCES
A. American National Standards Institute (ANSI) B-20.2 -Choin Standards for Inverted
Tooth (Si|ont) Chains and Sprockets.
142O2-1
B. American Society of Mechanical Engineers (ASME)A17.1 - Safety Code for
Elevators and Escalators.
C. American Society of Mechanical Engineers (ASME)A18.1 - Safety Standard for
Platform and Stairway Chair Lifts.
D. CSA B44.1 - Elevator and Escalator Electrical Equipment.
E. CSA B355 - Lifts for Persons with Physical Disabilities.
F. CSA B613 - Private Residence Lifts for Persons with Physical Disabilities.
G. U.S. Architectural &Transportation Barriers Compliance Board's "Americans with
Disabilities Act (ADA), Accessibility Guidelines for Buildings and Facilities
(ADAAG)".
H. ICC/ANSI A117.1 -Accessible and Usable Buildings and Facilities.
I. NFPA 70 - National Electric Code.
J. CSA- National Electric Code.
1.4 REQUIREMENTS OF REGULATORY AGENCIES:
A. Fabricate and install work in compliance with applicable jurisdictional authorities.
B. File shop drawings and submissions with local authorities as the information is made
available. Company pre-inspection and jurisdictional authority inspections and
permits are to be made on timely basis as required.
1.5 SUBMITTALS
A. Submit under provisions of Section 01300.
B. Product Data: Manufacturer's data sheets on each product to be used, including:
1. Preparation instructions and recommendations.
2. Storage and handling requirements and recommendations.
3. Installation methods.
C. Shop Drawings: Provide a complete layout of lift equipment detailing dimensions
and clearances as required.
D. Selection Samples: For each finish product specified requiring selection of color or
finish, two complete sets of color charts representing manufacturer's full range of
available colors and patterns.
1.6 QUALITY ASSURANCE
A. Installer Qualifications:
1. Skilled tradesmen shall be employees of the installing contractor approved by
the manufacturer, with demonstrated ability to perform the work on a timely
basis.
2. Execute work of this section only by a company that has adequate product
liability insurance.
1.7 DELIVERY, STORAGE, AND HANDLING
A. Store products in manufacturer's unopened packaging until ready for installation.
14202-2
B. Store and dispose of solvent-based materials, and materials used with solvent-
based materials, in accordance with requirements of local authorities having
jurisdiction.
1.8 PROJECT CONDITIONS
A. Maintain environmental conditions (temperature, humidity, and ventilation)within
limits recommended by manufacturer for optimum results. Do not install systems
under environmental conditions outside manufacturer's absolute limits.
1.9 WARRANTY
A. Coverage -this warranty applies to the repair or replacement, at Manufacturer's
option, of parts that fail due to defective material or workmanship. Manufacturer
may, at its option, provide factory reconditioned parts. This warranty is provided to
the Authorized Dealer on behalf of the final purchaser of the product and is not
transferable. The Manufacturer's warranty does not cover labor charges for the
removal, repair or replacement of warranty parts but such costs may be covered for
a period of time by Authorized Dealer's warranty, which is provided to purchaser
separately.
1. The manufacturer shall offer a 36-month limited warranty on parts from date
of shipment.
PART 2. PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: Savaria, which is located at: 2 Walker Drive, Brampton,
ON, Canada, L6T 5E1; Toll Free Tel: 800-661-5112; Tel: 905-791-5555; Fax: 905-
791-2222; Email: request info; Web: www.savaria.com
B. Substitutions: Not permitted.
C. Requests for substitutions will be considered in accordance with provisions of
Section 01600.
2.2 COMMERCIAL WHEELCHAIR LIFT
A. Hydraulic Vertical Platform Lifts: Savaria V1504-STD.
B. Hydraulic Vertical Platform Lift: The lift described here, manufactured by Savaria
Lifts Inc, is a vertical platform lift consisting of a hydraulic tower with a lifting
platform. The platform is made to accommodate a wheelchair user or a person with
impaired mobility. The lift can be used indoor or outdoor (with optional package) and
in commercial or residential applications.
C. Work described in this section includes providing equipment, incidental material and
labor required for complete, operable roped hydraulic wheelchair lift installation. Lifts
shall be erected, installed, adjusted, tested and placed in operation by lift system
manufacturer, or manufacturer's authorized installer.
1. Lifts shall be in accordance:
a. ASME A18.1 and ADAAG compliant (USA)
b. ASME A18.1 and A117.1 compliant (USA)
C. ASME 18.1 only(USA)
d. CSA B355 (Canada)
14202-3
D. The following preparatory work to receive the lifts specified in this section is part of
the work of other sections:
1. Permanent 120 VAC, 20 amp single phase power to operate lift to be
provided from a lockable fused/cartridge type disconnect switch with auxiliary
contacts for battery operation. Refer to drawings for permanent power
specifications and location of disconnects. Temporary power may be provided
to expedite installation of lift.
2. Provide a plumb and square hoistway with smooth interior surfaces, including
fascias or furring of the hoistway interior.
3. Provide rough openings per lift contractor's shop drawings.
4. Provide substantial, level pit floor slab as indicated on the lift contractor's shop
drawings.
E. Characteristics:
1. Rated Load: 750 lb (340 kg).
2. Rated Speed: 20 fpm (0.10 m/s).
3. Car Dimensions:
a. 36 inches W by 54 inches D (914 mm by 1371 mm)—Standard
b. 36 inches W by 48 inches D (914 mm by 1219 mm)
C. 36 inches W by 60 inches D (914 mm by 1524 mm)
d. 42 inches W by 60 inches D (1067 mm by 1524 mm)
4. Levels Serviced:
a. 2.
b. 3.
C. 4.
5. Car Configuration:
a. Enter/Exit same side.
b. 90 degree exit.
C. Front/rear exit.
6. Travel: feet. Maximum of 14' in US and 23' in Canada.
7. Pit Depth:
a. 3"—Standard
b. 0"— Fixed Ramp Required
8. Powder Coat Finish
a. Almond beige—Standard
b. Optional Color— From manufactures color chart
C. Custom Color— Provide color sample to manufacturer
9. Operation: Constant pressure.
10. Power Supply: 110 volt, 20 amp, 1 phase, 60 Hz.
11. Drive System: 2:1 Roller chain hydraulic.
12. Emergency Power:
a. Battery operation in down direction —Standard.
b. 24VDC Battery raising and lowering -Optional
13. Controller: Relay logic based controller.
14. Motor/Pump: 3HP (2.24 kw), gear type
15. Manual Lowering: Outside the hoistway at lower landing.
F. Car Enclosure:
1. Cab Configuration:
a. Side Guards of platform shall have a steel frame with a powder coat
finish and steel panel inserts to a minimum of 42 inches (1067 mm)
high.
b. Side Guards of platform shall have a steel frame with a powder coat
finish and steel panel inserts to a minimum of 80 inches (2032 mm)
above the upper landing. A steel ceiling with an egg crate insert and 4
x LED lights shall be provided.
14202-4
C. Side Guards of platform shall have a steel frame with a formica finish to
a minimum of 80 inches (2032 mm)above the upper landing. The
formica choice will be selected from manufactures standard offerings.
A steel ceiling with an egg crate insert and 4 x LED lights shall be
provided.
G. Doors and Gates:
1. First landing door:
a. Door type:
1) 80" High 1-1/2 hour UL/ULC fire-rated Prodoor with concealed
hinges and a concealed electro/mechanical interlock.
2) 80" low profile aluminum door with a concealed
electro/mechanical interlock.
b. Flush closing operation with hoistway side.
C. Operation
1) Manual —with hydraulic closer
2) Automatic-Concealed 24 volt door opener with battery back-up
for fire-rated door.
3) Automatic-Surface 24 volt door opener with battery back-up for
low profile aluminum door.
d. Door Width
1) 36 inches (889 mm) clear opening.
2) 42 inches (1067 mm) clear opening
2. Intermediate landing 1 door:
a. Door type:
1) 80" High 1-1/2 hour UL/ULC fire-rated Prodoor with concealed
hinges and a concealed electro/mechanical interlock.
2) 80" low profile aluminum door with a concealed
electro/mechanical interlock.
b. Flush closing operation with hoistway side.
C. Operation
1) Manual —with hydraulic closer
2) Automatic-Concealed 24 volt door opener with battery back-up
for fire-rated door.
3) Automatic-Surface 24 volt door opener with battery back-up for
low profile aluminum door.
d. Door Width
1) 36 inches (889 mm)
2) 42 inches (1067 mm)
3. Intermediate landing 2 door:
a. Door type:
1) 80" High 1-1/2 hour UL/ULC fire-rated Prodoor with concealed
hinges and a concealed electro/mechanical interlock.
2) 80" low profile aluminum door with a concealed
electro/mechanical interlock.
b. Flush closing operation with hoistway side.
C. Operation
1) Manual —with hydraulic closer
2) Automatic-Concealed 24 volt door opener with battery back-up
for fire-rated door.
3) Automatic-Surface 24 volt door opener with battery back-up for
low profile aluminum door.
d. Door Width
1) 36 inches (889 mm)
2) 42 inches (1067 mm)
14202-5
4. Upper landing door/gate:
a. Door/gate type:
1) 80" High 1-1/2 hour UL/ULC fire-rated Prodoor with concealed
hinges and a concealed electro/mechanical interlock.
2) 80" low profile aluminum door with a concealed
electro/mechanical interlock.
3) 42" low profile aluminum gate with a concealed
electro/mechanical interlock.
b. Flush closing operation with hoistway side.
C. Operation
1) Manual —with hydraulic closer
2) Automatic-Concealed 24 volt door opener with battery back-up
for fire-rated door.
3) Automatic-Surface 24 volt door opener with battery back-up for
low profile aluminum door.
4) Automatic—Surface mounted gate opener for low profile
aluminum gate.
d. Door/Gate Width
1) 36 inches (889 mm)
2) 42 inches (1067 mm)
H. Call Stations: Provide flush, surface or door frame mounted landing call/send
stations.
1. Call stations will be:
a. Keyless
b. Keyed (removable in off position)
C. Keyed (removable in on/off position)
I. Car Operation:
1. Car Operating Panel shall consist of constant pressure buttons, emergency
stop/alarm button, on/off key switch (when applicable)and emergency LED
light mounted on a removable stainless steel panel (Type 304#4 Stainless
Steel Finish).
2. Auxiliary lighting: The car shall be equipped with a battery operated LED light
fixture. The battery shall be the rechargeable type with an automatic
recharging system.
3. Telephone: The car shall be equipped with a
a. Hand held recessed telephone
b. ADA Hands free phone.
J. Pumping Unit and Control:
1. The pumping unit and control shall be enclosed in the tower. The controller
and pump unit shall be pre-wired and tested prior to shipment. The controller
is to be relay logic based operation for ease of maintenance and service.
Pump unit shall incorporate the following features:
2. Adjustable pressure relief valve.
3. Manually operable down valve to lower lift in the event of an emergency. This
valve shall be activated from outside of the hoistway through a keyed box.
4. Pressure gauge isolating valve, manually operable.
5. Gate valve to isolate cylinder from pump unit.
6. Electrical solenoid for down direction control.
7. Emergency Operation -A manual lowering device shall be located outside the
hoistway in a lockable box positioned at a lower landing.
K. Cylinder And Plunger:
1. The cylinder shall be constructed of steel pipe of sufficient thickness and
14202-6
suitable safety margin. The top of the cylinder shall be equipped with a
cylinder head with an internal guide ring and self-adjusting packing.
2. The plunger shall be constructed of a steel shaft of proper diameter machined
true and smooth. The plunger shall be provided with a stop electrically welded
to the bottom to prevent the plunger from leaving the cylinder.
L. Roller Chains: Two No.50 roller chains with 5/8 inch (16 mm) pitch. Minimum
breaking strength 6100 lb (2773 kg)each.
M. Leveling Device:
1. The lift shall be provided with an anti-creep device which will maintain the
carriage level within 1/2 inch (12 mm)of each landing.
2. All limit switch and leveling device switches shall be located in a position to be
inaccessible to unauthorized persons. They shall be located behind the mast
wall and be accessible through removable panels.
N. Guide Yoke: The 2:1 guide yoke/sprocket assembly shall be supplied with idler
sheaves, roller guide shoes, bearings and guards.
O. Terminal Stopping Devices: Normal terminal stopping devices shall be provided at
top and bottom of runway to stop the car positively and automatically.
P. Guide Rails and Brackets: Steel 'C"guide rails and brackets shall be used to guide
the platform and sling. Guide rails shall form part of the structural integrity of the unit
and be integral to the mast enclosure, ensuring stability and minimum platform
deflection when loaded.
Q. Car Sling: Car sling shall be fabricated from steel tubing 44 inches (1116 mm) high
with adequate bracing to support the platform and car enclosure. Roller guide shoes
shall be mounted on the top and bottom of the car sling to engage the guide rails.
Guide shoes shall be roller type with 3 inches (76 mm)diameter wheels. Nylon
guide shoes shall not be used for better ride quality and durability.
R. Wiring: All wiring and electrical connections shall comply with applicable codes.
Insulated wiring shall have flame-retardant and moisture-proof outer covering and
shall be run in conduit or electrical wire ways if located outside the unit enclosure.
Quick disconnect harnesses shall be used when possible.
PART 3. EXECUTION
3.1 EXAMINATION
A. Do not begin installation until hoistway and machine room has been properly
prepared.
B. Site dimensions shall be taken to verify that tolerances and clearances have been
maintained and meet local regulations.
C. If substrate preparation is the responsibility of another installer, notify Architect of
unsatisfactory preparation before proceeding. PREPARATION
A. Clean surfaces thoroughly prior to installation.
B. Prepare surfaces using the methods recommended by the manufacturer for
achieving the best result for the substrate under the project conditions.
3.3 ELEVATOR INSTALLATION
A. Install in accordance with manufacturer's instructions.
14202-7
B. Install the components of the elevator system that are required and that are required
by jurisdictional authorities to license the elevator.
A. Trained employees of the elevator contractor shall perform installation work.
B. Adjust elevator for proper operation and clean unit thoroughly.
C. Instruct users in operating procedures and owner's maintenance person in trouble-
shooting and maintenance procedures.
3.4 LIFT INSTALLATION
A. Install all the components of the lift system that are specified in this section to be
provided, and that are required by jurisdictional authorities to license the lift.
B. Trained employees of the lift contractor shall perform all installation work of this
section.
C. Adjust lift for proper operation and clean unit thoroughly.
D. Instruct users in operation procedures and Owner's maintenance person in trouble-
shooting and maintenance procedures.
3.5 PROTECTION
A. Protect installed products until completion of project.
B. Touch-up, repair or replace damaged products before Substantial Completion.
END OF SECTION
14202-8