2.2 2.2 WASTEWATER-SEWER�APPROVE�Ioffnan—HoldnigTankReplacementSetbacksRequestforTimeExtension—InAPA-11-20-2023 RESOLUTION APPROVING WENDY HOFFMAN'S APPLICATION FOR SANITARY SEWAGE DISPOSAL VARIANCES AND EXTENSION OF TIME TO COMPLETE WASTEWATER SYSTEM IMPROVEMENTS RESOLUTION NO.: 12023 INTRODUCED BY: WHO MOVED ITS ADOPTION SECONDED BY: WHEREAS, Wendy Hoffinan (Applicant) filed an application for variances from Chapter 136, §136-11 which requires applicants to obtain a variance for a holding tank system, as the Applicant wishes to replace the existing deficient onsite wastewater system by installing a holding tank system consisting of two (2) holding tanks each with a 1,500 gallon capacity, thus meeting the required total capacity of 3,000 gallons, with placement of the holding tank system to be located 8' from the north property line in lieu of the required 10' setback on property located at 146 Lake Parkway in the Town of Queensbury, and WHEREAS, the Town Clerk's Office published the Notice of Public Hearing in the Town's official newspaper and the Local Board of Health duly conducted a public hearing concerning the variance request on Monday,November 20t', 2023, and WHEREAS, the Town Clerk's Office has advised that it duly notified all property owners within 500 feet of the subject property, and WHEREAS, Town Code Chapter 137 requires inspection of Onsite Wastewater Treatment Systems (OWTS) prior to the sale of certain real property and provides that a $2,000 escrow deposit will be forfeited to the Town in the event that completion of a wastewater treatment system meeting all standards is not completed within the time provided, and WHEREAS, a change of deed for the Applicant's property occurred and when the required property transfer septic inspection took place, it was found that the existing wastewater system was deficient; however, the proposed new system is not able to be completed within the required six (6) month time period due to the time of year and timing of permitting, and WHEREAS, the Applicant has therefore applied for a timeline extension or until May 01, 2024 to install the system and to extend the date on which the $2,000 escrow deposit she previously deposited with the Town shall be automatically forfeited and the Town's Director of Building and Codes Enforcement has recommended Town Board approval of this requested extension, NOW, THEREFORE, BE IT RESOLVED,that 1. due to the nature of the variances, the Local Board of Health determines that the variances would not be materially detrimental to the purposes and objectives of this Ordinance or other adjoining properties nor otherwise conflict with the purpose and objectives of any Town plan or policy; and 2. the Local Board of Health finds that the granting of the variances is necessary for the reasonable use of the land and are the minimum variances which would alleviate the specific unnecessary hardship found by the Local Board of Health to affect the Applicants; and BE IT FURTHER, RESOLVED, that the Local Board of Health hereby approves the application of Wendy Hoffinan for variances from the Sewage Disposal Ordinance to replace the existing deficient onsite wastewater system by installing a holding tank system consisting of two (2) holding tanks each with a 1,500 gallon capacity, thus meeting the required total capacity of 3,000 gallons, with placement of the holding tank system to be located 8' from the north property line in lieu of the required 10' setback on property located at 146 Lake Parkway in the Town of Queensbury and bearing Tax Map No: 226.15- 1-8, and [BE IT FURTHER, RESOLVED, that the premises shall not be rented until and unless the holding tank system has been approved and installed and determined to be in compliance as confirmed by the Director of Building and Codes Enforcement, and] BE IT FURTHER, RESOLVED, that the Local Board of Health further authorizes and grants the Applicant additional time to obtain a certificate of compliance from the Town's Building and Codes Enforcement Office as set forth in Chapter 137 to complete installation of the holding tank system and extends the date on which the $2,000 escrow deposit the Applicant previously deposited with the Town be automatically forfeited to the Town until May 6th, 2024 and authorizes and directs the Director of Building and Codes Enforcement to take any and all actions necessary to effectuate the terms of this Resolution, and BE IT FURTHER, RESOLVED, that the Town Board authorizes and directs the Town Clerk to forward by certified mail a certified copy of this Resolution to the Adirondack Park Agency for its review, and BE IT FURTHER, RESOLVED, that this approval Resolution shall not be effective until 30 days after such notice to the Adirondack Park Agency and shall be subject to any lawful action by the Adirondack Park Agency during such period. Duly adopted this 20t'day of November, 2023,by the following vote: AYES NOES ABSENT: 169 Haviland Road Queensbury, NY 12804 Hutchins Engineering PLLC PFax: (518)745 03087 October 23, 2023 Town of Queensbury Town Board Board of Health P r 742 Bay Road Oti. Queensbury NY 12804 ��' 1 sr Queensbury \-, Re: Wendy Hoffman 1' Q _ d/7;: 146 Lake Parkway - - co g ��4903 Tax Map ID: 226.15 1 8 e-� f6�,j,,��QOJ)) s ott/c t 8 .. Dear Supervisor Strough & Town Board Councilmen: e This office represents Ms. Wendy Hoffman with respect to the pursuit of wastewater variances for a holding tank system installation at her property located at 146 Lake Parkway. Presently the home is served by a unknown sized seepage pit which is far from adequate and they desire to bring the parcel up to the town's current on-site wastewater system standards. Given the terrain and site constraints, it is not feasible to install an absorption field system, therefore we are pursuing the holding tank system. A change of Deed for the property occurred the beginning of 2023. The required septic inspection found the existing wastewater system to be deficient. Presently the house is served by a seepage pit, which is far from adequate and the applicants desire to install (2) 1500-gallon tanks to support the existing 2-bedroom residence. Relief is requested for the installation of the holding tank system which is detailed in the application. Also, 2 ft of relief is requested from the north side property line setback 'which requires 10 ft but we have proposed an 8 ft property line setback for the installation of the holding tanks. We are also requesting a 6-month extension from the property transfer law requirements for the installation of the holding tank system. Enclosed please find ten submission packages for this project. We respectfully request, if possible, that this item be placed upon the agenda of the next town board meeting. Please contact me if you have any questions or if you require additional information. Best Regards, Thomas R. Center Jr., P.E. Associate - Design Engineer Cc: Wendy Hoffman OWN SEPTIC VARIANCE Office Use Only ) Permit#: APPLICATION Permit Fee:$ Town of Cjcensbury Invoice#: 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.queensburv.net Approvals: Submittal: 1 (one) original &8 copies of the completed application package PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL Section 1: Contact Information: Property Owner(s): WENDY HOFFMAN Owner's Agent: HUTCHINS ENGINEERING,PLLC Address: 266 VAN RENSSELAER BLVD Address: 169 HAVILAND ROAD ALBANY,NY 12204 QUEENSBURY,NY 12804 Phone#: 518-466-0238 Phone#: 518-796-2515 Email: Email: TCENTER36@YAHOO.COM Section 2: Site Information: Site Address: 146 LAKE PARKWAY Tax ID#: 226.15-1-8 Directions to Site: RT 9L TO ASSEMBLY PT RD TO BAY PARKWAY TO LAKE PARKWAY Section 3: Distance from well on property to septic system (if applicable) NA feet Section 4: Is it possible to install a conforming septic system on this property? ❑Yes ❑■ No If YES, please explain and attach a diagram: Section 5: Does the proposed system meet setback requirements for distance from wells&septic systems on neighboring properties? *Yes ❑ No If NO, please explain: Section 6: Is the proposed system to be installed under a parking area? ❑ Yes ❑■ No Section 7: Section of the Sanitary Sewage Ordinance from which you are seeking the variance (i.e. leaching system will be 89 ft. from well in lieu of required 100 ft.): 136-11 HOLDING TANKS & 136-11 B.5 - 2 FT OF RELIEF FROM 10' SIDE Septic Variance Application Revised December 2021 Section 8: List the names, parcel addresses, and tax map numbers of all adjoining property owners. You may obtain this information from the Town of Queensbury's Assessor's Office: North Name PAUL & ARLENE LOTTERS Address 140 LAKE PARKWAY Tax Map ID 226.15-1-9 South Name SEAN & KAREN FLANAGAN Address 150 LAKE PARKWAY Tax Map ID 226.15-1-7 East Name OTYOKWA, INC Address LAKE PKRWY/45 GREAT HILL RD, RIDGEFIELD,CT 06877 Tax Map ID 226.15-1-38 West Name NA Address Tax Map ID Section 9: OWNER STATEMENT I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: NA . I/We realize that putting the well, septic tank or leaching system less than the required feet from the may increase the risk of pollution. Owner—Print Name: Owner—Signature: Date: Section 10: NEIGHBOR OR TENANT RELEASE STATEMENT(if applicable) I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: NA . I/We realize that putting the well, septic tank or leaching system less than the required feet from the may increase the risk of pollution. Neighbor/Tenant—Print Name: Neighbor/Tenant-Signature: Date: Septic Variance Application Revised December 2021 ii PLEASE ATTACH THE FOLLOWING TO YOUR APPLICATION: 1. A location map showing the site within the Town of Queensbury 2. A plot plan showing existing and proposed features of the property, including: a. Lot dimensions b. North arrow and scale: 1 inch=40 feet c. Location & dimensions of existing and proposed buildings, showing setback distances and uses d. Parking layout to scale (if applicable) e. Physical features (street, steep slopes, lakes, wetlands, etc.) f. Location of all wells and septic systems on neighboring properties g. Adjacent ownerships h. All properties within 500 feet A sample plot plan and location are shown below: \ 1-``._. 1 — .� ,; 41 irs,;(w.S: J //f�, h1)---\'' u \l�- - r / 'J. is•� _ 5"4""� F3� : 1_1: ! -mot , «� - I it ~ Z L'� `_ 3 \ C. F ..v r r'..-- ..\„...__ ..,...:..,-'-i.-` / ..,--"--rias,''''' ic"—er. t / / kti.:p. 7..".". / I 4.„ N --IL „r I r ; `• r ` G; ;°l N_YL:, ff / 61 e.-.c t.._ ?� A `�� 1 thst t un dY � j 1 i t- I amrx:trn!cn Fts. r am' p re.4n Cftea ff 1 1 ;, — 47 i --_--3-',...,,u _______,---- ----- ./... 11----:ILC-1-,_ _ _— _— —r�---' i J 1 ^ r kr___.._ _ js c sH' Id ri/L+ r: Septic Variance Application Revised December 2021 Section 11: AUTHORIZATION AND SIGNATURE PAGE This page includes the Authorization to Act as Agent form, engineering fee disclosure, authorization for site visits, other permit responsibilities and agreement to provide documentation required. Complete the following if the OWNER is using an Agent: Owner's Name: WENDY HOFFMAN Designates: HUTCHINS ENGR as agent regarding the Septic Variance for Site Address: 146 LAKE PARKWAY Tax Map#: 226.15=1-8 Engineering Fee Disclosure: Applications may be referred to the Town consulting engineer for review of septic design, storm drainage, etc. as determined by the Town Board of Health. Fees for engineering review services will be charged directly to the applicant. Authorization for Site Visits: By signing this page and submitting the application materials attached herein,the Owner, Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code Enforcement Officers and Town Engineer to enter the subject properties for the purpose of reviewing the application submitted. Please Note: Other permits may be required for construction or alteration activity subsequent to approval by the Town Board of Health. It is the applicant's responsibility to obtain any additional permits. Official Meeting Minutes Disclosure: It is the practice of the Town Board of Health to have a designated stenographer tape record the proceedings of the meetings resulting from the application, and that the minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy between such record and the handwritten minutes taken by the designated stenographer,the handwritten minutes shall be deemed the official record. I, the undersigned, have thoroughly read and understand the instructions for submission; agree to the submission requirements and completed checklist: OWNER—PRINT NAME: OWNER—SIGNATURE: DATE: AGENT—PRINT NAME: TOM CENTER, PE HUTCHINS ENGINEERING AGENT—SIGNATURE: n/1 �/ / t� DATE: 10/23/23 Septic Variance Application Revised December 2021 Lake George 3. 7'± To Mean High Water CAST IRON MANHOLE COVER W/WATERTIGHT INSERT, QTY. 2 PER TANK PRECAST CONCRETE RISER, MORTARED TO TANK COVER MIN._ SLOPE 114" PER FOOT TOP TO BASE SEAM TO BE BUTYL SEALED AND 12" WIDE EXTERIOR BUTYL WRAP TO BE PLACED AROUND THE PERIMETER OF SEAM PRIOR TO BACKFILL EXTERIOR OF TANKS TO BE COATED WITH ASPHALT EMERSION COATING 4" PVC INLET TEE -BAFFLE & TAILPIECE NOTE: NO WELLS ARE VISIBLE WITHIN 50' OF PROP. HOLDING TANKS Lands of Sean P. & Karen L. Flanagan D:3880 P:52 226.15-1-7 1 A1d CTFI AZd TF12 CYCTFM DI d N SCALE. 1 "=20' CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES. GRAPHIC SCALE 10 0 5 10 20 40 IN FEET ) FINISHED LAWN AREA 12- MIN. INLET COVER MAXIMUM LIQUID LEVEL MAINTAIN 2" MINIMUM DROP 16" IN INVERTS BETWEEN INLET & OUTLET PIPES 12" OF 314-1-112" CRUSHED STONE HOLDING TANK SIZING 1500 GALLON STANDARD DUTY PRECAST CONCRETE HOLDING TANK 1-PIECE TANK W/TOP & W/ANTI-FLOAT BASE EXTENSIONS BY MANUFACTURER 1 2-BEDROOM RESIDENCE WATER SAVING FIXTURES - INSTALL NEW FIXTURES AS NEEDED (1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS) DESIGN FLOW - 110 GPD/BEDROOM SYSTEM DESIGN FLOW - 220 GPD NYSDOH MINIMUM SIZING - 5-DAYS DESIGN FLOW - 1100 GALS TOWN OF QUEENSBURY REQUIRED HOLDING TANKS CAPACITY - 3000 GALS - INSTALL (2) 1500 GAL PRECAST CONCRETE HOLDING TANKS IN -SERIES TO PROVIDE ADDITIONAL TIME BETWEEN PUMP OUTS 3000 GALLONS OF STORAGE TO BE PROVIDED -POTABLE WATER SUPPLY IS EXISTING LAKE WATER SUPPLY CAST IRON MANHOLE COVER W/WATERTIGHT INSERT, QTY. 2 PER TANK PRECAST CONCRETE RISER, MORTARED TO TANK COVER OUTLET HOLDING TANKS DETAIL SCALE. NTS -SOLENOID VALVE OR EQUIVALENT ELECTRICAL INTERLOCK TO BE INSTALLED ON WATER PUMP CIRCUIT TO SHUT DOWN WATER SUPPLY TO HOUSE WHEN ACTIVATED BY WARNING/SHUT DOWN ALARM ON PANEL MIN. SLOPE 118" PER FOOT CONIVECTOR PIPE HOLDING TANK ALARM NOTES OUTLET ALARM PANEL CONTROLS SHALL BE SJE RHOMBUS TANK ALERT DUO, MODEL TAEZ-01HDUO, ALARM SYSTEM OR EQUIVALENT, AND PROVIDE THE FOLLOWING MONITORING AND CONTROL FUNCTIONS. WHEN LEVEL OF TANK REACHES 85% CAPACITY, YELLOW WARNING LIGHT INDICATING "TANK HIGH LEVEL" WILL BE ACTIVATED AND AUDIBLE ALARM WILL SOUND. WHEN LEVEL OF TANK REACHES 95% CAPACITY, AUDIBLE ALARM WILL SOUND AND RED LIGHT WILL FLASH, INDICATING "TANK SHUTOFF LEVEL". SOLENOID VALVE OR EQUIVALENT ELECTRICAL INTERLOCK SHALL BE INSTALLED TO DISABLE WATER SUPPLY TO BUILDING UPON REACHING "TANK SHUTOFF LEVEL". SYSTEM WILL RESET AFTER HOLDING TANK IS PUMPED DOWN TO BELOW THE ACTUATION LEVEL OF "TANK HIGH LEVEL" ALARM. AN ELECTRICAL INSPECTION BY A CERTIFIED ELECTRICAL INSPECTION AGENCY IS REQUIRED AFTER INSTALLATION. ELECTRICAL INSPECTION SEAL IS TO BE AFFIXED TO ALARM CONTROL PANEL. FINISHED LAWN AREA Bench Mark Nail In Pole NM 9 Elevation = 337.00 EXTERIOR WEATHERPROOF JUNCTION BOX (IF NECESSARY). SEAL CONDUIT GAS TIGHT. INSTALL CONTROL PANEL IN HOUSE 12" MIN. COVER MAXIMUM LIQUID LEVEL INSTALL FLOAT SWITCHES TO O OPERATE ALARM PANEL AT INDICATED LEVELS. O INSTALL FLOAT SWITCHES WHERE ACCESSIBLE THRU RISER TO GRADE. VARIANCE REQUEST SUMMARY THE FOLLOWING RELIEF IS REQUESTED FROM THE TOWN OF QUEENSBURY SEWERS AND SEWAGE DISPOSAL ORDINANCE, CHAPTER 136: SECTION 136-11 - HOLDING TANKS PART A. - "HOLDING TANKS ARE PROHIBITED UNLESS A VARIANCE IS GRANTED FOR A HOLDING TANK BY THE LOCAL BOARD OF HEALTH... " - INSTALL (2) 1500-GAL HOLDING TANKS IN -SERIES SECTION 136-11 B. (2) - HOLDING TANK SIZING 3-BEDROOMS - HOLDING TANK CAPACITY REQUIRED = 3000 GAL - INSTALL (2) 1500-GAL HOLDING TANKS IN -SERIES, 3000 GALS TOTAL TO BE PROVIDED SECTION 136-11 B.5 INSTALL HOLDING TANKS 8 FT FROM NORTH PROPERTY LINE WHERE 10 FT IS REQUIRED. 2 FT OF RELIEF IS REQUESTED. SITE SOILS DATA TC(`T nTT TP-1 - 0711912023 BY TOM CENTER, P.E. 0-9" - TOPSOIL 9-13" - LOAMY FINE SILTY SAND 13-17" - TOPSOIL 17-29" - LOAMY FINE SILTY SAND 29-50" - MEDIUM FINE SILTY SAND MOTTLING @ 20" GROUNDWATER ® 40" 95Z CAPACITY (2850 GAL) WARNING ALARM / WATER SHUT DOWN 1500 GALLON STANDARD DUTY 8(CAPACITY 2 550 GAL) PRECAST CONCRETE HOLDING TANK TANK HIGH LEVEL 1-PIECE TANK WI TOP & W/ANTI -FLOAT YELLOW LIGHT ON BASE EXTENSIONS BY MANUFACTURER & WARNING ALARM i i SYSTEM MATERIAL SPECIFICATIONS BACKFILL MATERIAL BACKFILL MATERIAL TO BE GRANULAR BACKFILL MATERIAL WITH NO PARTICLES GREATER THAN 2" HOLDING TANK CONNECTOR PIPE PIPING TO BE 4" SCH-40 PVC. INSTALL LEVEL BETWEEN OUTLET PORTS OF TANKS. BUILDING SEWER PIPE PIPING TO BE 4" SCH-40 PVC. INSTALL WITH 114" PER FOOT MINIMUM SLOPE. TOPSOIL PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED, MULCH, AND ESTABLISH TURF. HOLDING TANK NOTES ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS MANUFACTURED BY PALETTE STONE CORP. ALL STRUCTURES SHALL BE PLACED ON FIRM, CRUSHED STONE BASE. HOLDING TANKS TO BE OF STANDARD PRECAST CONCRETE TANKS BY PALLETTE STONE CORP OR APPROVED EQUIVALENT. ALL JOINTS MUST BE SEALED WITH BUTYL SEALANT. TANKS SHALL BE OF ONE PIECE CONSTRUCTION SUCH THAT JOINTS ARE NOT LOCATED BELOW THE LIQUID LEVEL. EXTERIOR (TOP. BOTTOM. ALL SIDES) OF TANKS TO BE COATED WITH ASPHALT EMERSION COATING. BAY OIL COMPANY AQUA SAFE OR EQUIVALENT. TOP TO BASE SEAM TO BE BUTYL SEALED AND 12" WIDE EXTERIOR BUTYL WRAP TO BE PLACED AROUND THE PERIMETER OF SEAM PRIOR TO BACKFILL. MAP REFERENCE: BASE MAP INFORMATION FROM A MAP OF A SURVEY MADE FOR WENDY HOFFMAN BY VAN DUSEN & STEVES LAND SURVEYORS., WARREN COUNTY GIS, AERIAL PHOTOGRAPHY, AND FIELD MEASUREMENTS. CONTRACTOR TO FIELD VERIFY ALL SETBACKS PRIOR TO BEGINNING INSTALLATION. WASTEWATER SYSTEM SETBACK REQUIREMENTS PROPERTY LINE HOUSE STREAM, LAKE, WATERCOURSE, WETLAND WELL SEPTIC TANK 10' 10' 50' 50' ABSORPTION FIELD 10' 20' 100' 1 100' SITE Dig P Safely. Newyork Call Before You Dig Wait The Required Time Confirm Utility Response E3 Respect The Marks Dig With Care 800-962.7962 www.digsafelynewyork.com LUC,A I lU1V MAP Neighborhood Map TAX MAP # 226.15-1-8