CC-0030-2023 i
,, � Office Use Only
st, ADDITION ALTERATION PERMIT
� Permit#: Cam. 010. 0- 2D2�
Town ofQvee sn n ry APPLICATION �
Permit Fee:$ 20
_ 742 Bay Road,Queensbury,NY 12804 6
P:518-761-8256 www.queensburv.net Invoice#: �O
Flood Zone? Y O Reviewed By: .5
Project Location: 578 Aviation Road, Queensbury .New York
Tax Map ID#: 302.5-1-92.12 - Subdivision Name:
PROJECT INFORMATION:
TYPE: ❑ Residential ® Commercial, Proposed Use: Target
❑ Single-Family ❑ Two-Family ❑ Multi-Family(#of units_) ❑ Townhouse
❑ Business Office ❑ Retail ❑ Industrial/Warehouse ❑ Garage (#of cars )
❑ Other(describe )
ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE:
1st floor: 1st floor:
2nd floor: 2nd floor:
3rd floor: 3rd floor:
Basement (habitable space): Basement (habitable space):
Total sq ft: Total sq ft: 1200
Scope of work to be done: Minor interior alterations to an existing Target store
rovvry oi=
.��_- coDis
„,
Addition/Alteration Application Revised June 2022
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction: $ 80,000.00
2. Source of Heat (circle one): R Gas ❑ Oil ❑ Propane ❑ Solar ❑ Other:
Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application
3. Are there any structures not shown on the plot plan? El YES R NO Explain:
4. Are there any easements on the property? ❑ YES R NO
SITE INFORMATION:
• Is this a corner lot? ❑ YES ❑ NO
• Will the grade be changed as a result of the construction? El YES R NO
• What is the water source? R PUBLIC El PRIVATE WELL
• What type of wastewater system is on the parcel? R SEWER ❑ PRIVATE SEPTIC
DECLARATION:
1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be
completed within a 12 month period.Any changes to the approved plans prior to/during construction will require
the submittal of amended plans,additional reviews and re-approval.
2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of
Queensbury.After 1 year from the initial application date, 100%of the fee is retained.
3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees
and department approval.
4. I certify that the application, plans and supporting materials are a true and a complete statement and/or description
of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws
and ordinances, and in conformance with local zoning regulations.
5. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of
occupancy.
6. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: Dwight Groom
SIGNATURE: DATE: 01/04/2023
Addition/Alteration Application Revised June 2022
CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL
• Applicant:
Name(s): Groom Construction-Patty Colone's
Mailing Address, C/S/Z: 96 Swampscott Road,Suite 6, Salem MA 01970
Cell Phone: ( )781-592-3135 Land Line: ( )
Email:pcolone@groomco.com
• Primary Owner(s):
Name(s): Target Corporation
Mailing Address, C/S/Z: 1000 Nicollet Mall TPS-3165, Minneapolis, MN 55403
Cell Phone: ( ) Land Line: (
Email:
❑ Check if all work will be performed by property owner only
• Contractor(s): (List all additional contractors on the back of this form)
Contact Name(s): Groom Construction-Patty Colone's
Contractor Trade:
Mailing Address, C/S/Z: 96 Swampscott Road,Suite 6, Salem MA 01970
Cell Phone: ( )781-592-3135 Land Line: ( )
Email:pcolone@groomco.com
**Workers' Comp documentation must be submitted with this application**
• Architect(s)/Engineer(s):
Business Name: Sargenti
Contact Name(s): Richard Torres
Mailing Address, C/S/Z: 461 From Road,Second Floor, Paramus, NJ 07652
Cell Phone: ( )732.425.4605 Land Line: (
Email:RTorres@sargarch.com
Contact Person for Compliance in regards to this project: Groom Construction-Patty Colone's
Cell Phone: ( )781-592-3135 Land Line: ( )
Email:Pcolone@groomco.com
WI2-O • Cown - ,.1
Addition/Alteration Application Revised June 2022
A( COMcheck Software Version 4.1.5.5
1 Interior Lighting Compliance Certificate
Project Information
Energy Code: 2018 IECC ��
Project Title: T-1830 Queensbury,NY re
Project Type: ,c� Alteration O n
`` v
Construction Site: 0 -0 Owner/Agent: Designer/Con.-ctor
578 Aviation RD. #1S I- G Target Corp Jeffrey A. Piehl
Queensbury, NY 12804 �a ��� Target Nelson-Rudie&Associates
1000 Nicollet Mall 9100 49th Ave. North
'O 0 Minneapolis, MN 55403 Minneapolis,OH 55428
O 763-367-7600
C� T jeff.piehl@nelsonrudie.com
Allowed Interior Lighting Power (j
A ��/ B C D
Area Category s Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B X C)
1-Sales Floor(Retail:Sales Area) 3592 1.22 4382
Total Allowed Watts= 4382
Proposed Interior Lighting Power
A B C D E
Fixture ID: Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Sales Floor(Retail:Sales Area 3592 sq.ft.)
LED 17:SP20:20'PENDANT LINEAR LED:LED Linear 33W: 1 6 200 1200
LED 18:VL12:4'FOCAL DOWN FIXTURE:Other: 1 18 40 720
LED 18 copy 1:VL13:4'GONDOLA DOWN LIGHT FIXTURE:Other: 1 48 20 960
LED 18 copy 2:VL13A:3'GONDOLA DOWN LIGHT FIXTURE:Other: 1 3 15 45
Total Proposed Watts= 2925
Interior Lighting PASSES
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any
applicable mandatory requirements listed in the Inspection Checklist.
Jeffrey A.Piehl-Electrical P.E. ;t"�E A. • re. 02/06/2023
Name-Title Signature �. y Date
la A
li l w
#'461,—,
85369- `•OF,SSI�i`„_
Project Title: T-1830 Queensbury, NY Report date: 01/24/23
Data filename: J:\2022\22632\14-Electrical Design\Lighting Calcs&Compliance Report\T1830 REMODEL Ulta.c Page 1 of 6
COMcheck Software Version 4.1.5.5
( Inspection Checklist
Energy Code: 2018 IECC
41
Requirements: 90.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
& Req.ID
C103.2 Plans,specifications, and/or ❑Complies Requirement will be met.
[PR4]i calculations provide all information ❑Does Not
with which compliance can be
determined for the interior lighting ❑Not Observable
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations,wattage of
bulbs and ballasts,transformers and
control devices.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: T-1830 Queensbury, NY Report date: 01/24/23
Data filename: J:\2022\22632\14-Electrical Design\Lighting Calcs&Compliance Report\T1830 REMODEL Ulta.c Page 2 of 6
,
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
&Req.ID
C405.2.2. ;Spaces required to have light- ❑Complies Requirement will be met.
2 :reduction controls have a manual ❑Does Not
[EL22]1 control that allows the occupant to ['Not Observable Location on plans/spec: E131
reduce the connected lighting load in
a reasonably uniform illumination ❑Not Applicable
pattern >= 50 percent.
C405.2.1, :Occupancy sensors installed in ❑Complies Requirement will be met.
C405.2.1. :classrooms/lecture/training rooms, ❑Does Not
1 conference/meeting/multipurpose Location on plans/spec: E131
[EL18]1 rooms,copy/print rooms, ['Not Observable
lounges/breakrooms,enclosed offices, ENot Applicable
open plan office areas, restrooms,
storage rooms, locker rooms,
warehouse storage areas, and other
spaces<=300 sqft that are enclosed
by floor-to-ceiling height partitions.
Reference section language
C405.2.1.2 for control function in
warehouses and section C405.2.1.3
for open plan office spaces.
C405.2.1. Occupancy sensors control function in ❑Complies Requirement will be met.
2 warehouses: In warehouses,the ❑Does Not
[EL19]1 lighting in aisleways and open areas is ❑Not Observable Location on plans/spec: E161
controlled with occupant sensors that
automatically reduce lighting power ❑Not Applicable
by 50%or more when the areas are
unoccupied.The occupant sensors
control lighting in each aisleway
independently and do not control
lighting beyond the aisleway being
controlled by the sensor.
C405.2.1. Occupant sensor control function in ❑Complies Requirement will be met.
3 open plan office areas: Occupant ❑Does Not
[EL20]1 sensor controls in open office spaces Location on plans/spec: E131
>= 300 sq.ft. have controls 1) ❑Not Applicable
vaui
configured so that general lighting can
be controlled separately in control
zones with floor areas<= 600 sq.ft.
within the space, 2)automatically turn
off general lighting in all control zones
within 20 minutes after all occupants
have left the space, 3)are configured
so that general lighting power in each
control zone is reduced by>= 80%of
the full zone general lighting power
within 20 minutes of all occupants
leaving that control zone,and 4)are
configured such that any daylight
responsive control will activate space
general lighting or control zone
general lighting only when occupancy
for the same area is detected.
C405.2.2, ;Each area not served by occupancy ❑Complies Requirement will be met.
C405.2.2. :sensors (per C405.2.1) have time- ❑Does Not
1, :switch controls and functions detailed ['Not Observable Location on plans/spec: E111, E601
C405.2.2. ;in sections C405.2.2.1 and C405.2.2.2.
2 ❑Not Applicable
[EL21]2
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: T-1830 Queensbury, NY Report date: 01/24/23
Data filename:;J:\2022\22632\14-Electrical Design\Lighting Calcs&Compliance Report\T1830 REMODEL Ulta.c Page 3 of 6
Section
Rough-In Electrical Inspection Complies? Comments/Assumptions
&Req.ID
C405.2.3, ;Daylight zones provided with ❑Complies Exception: Requirement does not apply.
C405.2.3. :individual controls that control the ❑Does Not
1, i lights independent of general area ❑Not Observable
C405.2.3. ,lighting.See code section C405.2.3
2 :Daylight-responsive controls for ❑Not Applicable
[EL2312 :applicable spaces,C405.2.3.1 Daylight
:responsive control function and
section C405.2.3.2 Sidelit zone.
C405.2.4 ;Separate lighting control devices for ❑Complies Requirement will be met.
[EL26]1 :specific uses installed per approved ElDoes Not
;lighting plans. Location on plans/spec: E131
❑Not Observable
❑Not Applicable
C405.2.4 ;Additional interior lighting power ElComplies Requirement will be met.
[EL27]1 :allowed for special functions per the ElDoes Not
;approved lighting plans and is
;automatically controlled and Not Observable
.separated from general lighting. ❑Not Applicable
C405.3 ;Exit signs do not exceed 5 watts per ❑Complies Exception: Requirement does not apply.
[EL6]1 'face. ❑Does Not
:Not Observable Location on plans/spec: E601
❑Not Applicable
C405.6 Low-voltage dry-type distribution ❑Complies Requirement will be met.
[EL26]2 electric transformers meet the ❑Does Not
;minimum efficiency requirements of
;Table C405.6. Not Observable
❑Not Applicable
C405.7 Electric motors meet the minimum ❑Complies Requirement will be met.
[EL27]2 :efficiency requirements of Tables ❑Does Not
1C405.7(1)through C405.7(4).
{Efficiency verified through certification ❑Not Observable
under an approved certification ❑Not Applicable
program or the equipment efficiency
ratings shall be provided by motor •
manufacturer(where certification
;programs do not exist).
C405.8.2, Escalators and moving walks comply ❑Complies Requirement will be met.
C405.8.2. :with ASME A17.1/CSA B44 and have ElDoes Not
1 ;automatic controls configured to
[EL2812 i reduce speed to the minimum ❑Not Observable
:permitted speed in accordance with ❑Not Applicable
ASME A17.1/CSA B44 or applicable
;local code when not conveying
;passengers.
C405.9 ;Total voltage drop across the ❑Complies Requirement will be met.
[EL29]2 combination of feeders and branch ❑Does Not
circuits<= 5%. ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: T-1830 Queensbury, NY Report date: 01/24/23
Data filename: J:\2022\22632\14-Electrical Design\Lighting Calcs&Compliance Report\T1830 REMODEL Ulta.c Page 4 of 6
Section
Final Inspection Complies? Comments/Assumptions
& Req.ID
C303.3, ;Furnished O&M instructions for ❑Complies Requirement will be met.
C408.2.5. :systems and equipment to the ODoes Not
2 }building owner or designated
[FI17]3 representative. ['Not Observable
❑Not Applicable
C405.4.1 ;Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values.
[FI18]1 lighting power is consistent with what ❑Does Not
is shown on the approved lighting
;plans,demonstrating proposed watts ❑Not Observable
are less than or equal to allowed Observable,..._,
Applicable
watts.
C408.1.1 ;Building operations and maintenance ❑Complies Requirement will be met.
[FI57]1 idocuments will be provided to the ❑Does Not
;owner. Documents will cover
;manufacturers' information, ❑Not Observable
'specifications,programming ❑Not Applicable
procedures and means of illustrating
to owner how building,equipment and
systems are intended to be installed,
maintained, and operated.
C408.2.5. :Furnished as-built drawings for ❑Complies Requirement will be met.
1 electric power systems within 90 days ❑Does Not
[FI16]3 ;of system acceptance. ['Not Observable
❑Not Applicable
C408.3 Lighting systems have been tested to ❑Complies Requirement will be met.
[FI33]1 ensure proper calibration,adjustment, ❑Does Not
programming,and operation.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: T-1830 Queensbury, NY Report date: 01/24/23
Data filename: J:\2022\22632\14-Electrical Design\Lighting Calcs&Compliance Report\T1830 REMODEL Ulta.c Page 5 of 6
Project Title: T-1830 Queensbury,NY Report date: 01/24/23
Data filename: J:\2022\22632\14-Electrical Design\Lighting Calcs&Compliance Report\T1830 REMODEL Ulta.c Page 6 of 6
. FIRE MARSHAL'S OFFICE
Town of Queensbury
742 Bay Road, Queensbury, NY 12804
J
"Home of Natural Beauty ... A Good Place to Live "
PLAN REVIEW
Target Corp.
578 Aviation Road
CC-0030-2023 •
2/3/2023
The following comments are based on review of drawings:
• FM has no comments at this time
Michael J Palmer
Fire Marshal
742 Bay Road
Queensbury NY 12804
firemarshal@queensbury.net
Fire Marshal 's Office ■ Phone: 518-761-8206 • Fax: 518-745-4437
firemarshal@queensbunj.net • www.queensbunj.net