Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
CC-0466-2023
- y Office Use Only ADDITION ALTERATION'PERMIT f� � Permit#: �— �'�f�(o-- 7�Z� Tam ofQueen-s6uzy APPLICATION Permit Fee:$ 6 !1‘,. 742 Bay Road,Queensbury,NY 12804 q P:518-761-8256 www.oueensburv.net Invoice#: 0 2— Flood Zone? Y Reviewed B . Project Location: 713 Upper Glen St. Tax Map ID#: Subdivision Name: PROJECT INFORMATION: TYPE: El Residential i] Commercial,Proposed Use: Dunkin' Donuts ❑ Single-Family 0 Two-Family El Multi-Family(#of units_J 0 Townhouse O Business Office ❑ Retail 0 Industrial/Warehouse 0 Garage(#of cars ❑ Other(describe ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 1355 2nd floor: 2nd floor: 3rd floor: 3rd floor: Basement(habitable space): Basement(habitable space): Total sq ft: Total sq ft: 1355 Interior work Only, No Exterior work to be completed on this permit, Scope of work to be done:_ Change interior finishes, relocate mechanicals for relocated equipment, minor non structural framing of interior partitions and soffit. New millwork and furniture package. Addition/Alteration Application Revised June 2022 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction:$ 150,000.00 2. Source of Heat(circle one): g Gas ❑ Oil ❑ Propane 0 Solar ❑ Other: Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? ❑ YES NO Explain: 4. Are there any easements on the property? ❑ YES ❑ NO SITE INFORMATION:. • Is this a corner lot? ❑ YES g NO • Will the grade be changed as a result of the construction? ❑ YES ! NO • What is the water source? G PUBLIC 0 PRIVATE WELL • What type of wastewater system is on the parcel? g SEWER ❑ PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date,100%of the fee is retained. 3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. I certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations. 5. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Pat Shaw -s SIGNATURE: �� -- -- `%!-� DATE: 9/11/23 Addition/Alteration Application Revised June 2022 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Pat Shaw Mailing Address, C/S/Z: 449 State Route 281 ,Tully,NY 13159 Cell Phone: ( )(315)440-5283 Land Line: ( ) Email:patshaw280@gmail.com • Primary Owner(s): Name(s): Thomas J Burke Jr (North Star Donut Group) Mailing Address, C/S/Z: 509 State Route 67, Malta,NY 12020 Cell Phone: ( )(518)209-3397 Land Line: ( ) Email:tomburke@theburkecompanies.com ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Pat Shaw(T.Shaw Inc) Contractor Trade: General Contractor Mailing Address, C/S/Z: 449 State Route 281 ,Tully, NY 13159 Cell Phone: ( )(315)440-5283 Land Line: ( ) Email:patshaw280@gmail.com **Workers' Comp documentation must be submitted with this application** • Architect(s)/Engineer(s): Business Name: Ahoronian&Associates Inc. Architects Contact Name(s): Jackie Daley Mailing Address, C/S/Z: 310 George Washington Highway Suite 100 ,Smithfield Rhode Island 02917 Cell Phone: ( )(401)232-5010 Land Line: ( Email:idaley@arch-eng.com Contact Person for Compliance in regards to this project: Pat Shaw Cell Phone: ( )(315)440-5283 Land Line: ( ) Email:Patshaw280@gmail.com Addition/Alteration Application Revised June 2022 COMcheck Software Version COMcheckWeb II(lit Interior Lighting Compliance Certificate RE1/IE�/UE ? FOR ENERGY CODE COMPLIANCE Project Information Energy Code: 2020 New York State Energy Conservation Construction Code Project Title: Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 713 Upper Glen st Tom Burke Jackie Brousseau Queensbury, New York 12804 509 State Route 67 Aharonian&Associates Malta, New York 12020 310 George Washington Hwy,Suite 518-209-3397 100 tomburke@theburkecompanies.co Smithfield, Rhode Island 02917 FILE COPY m 401232 5010 jbrousseau@arch-eng.com Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed (ft2) Watts/ft2 Watts 1-Common Space Types:Restrooms 105 0.85 89 2-Common Space Types:Dining Area-Cafeteria/Fast Food 855 0.63 539 3-Common Space Types:Food Preparation 494 1.06 524 Total Allowed Watts = 1152 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp /Wattage Per Lamp/ Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. Common Space Types: Restrooms (105 sq.ft.) R2: LED Panel 33W: 1 2 32 64 Common Space Types: Dining Area -Cafeteria/Fast Food (855 sq.ft.) R2: LED Panel 33W: 1 19 32 608 P3: LED A Lamp 9W: 1 4 9 36 A: Other: 1 4 9 36 Common Space Types: Food Preparation (494 sq.ft.) R5: LED Panel 44W: 1 6 44 264 R1: LED PAR 11W: 1 9 11 99 R4-8: LED Linear 11W: 1 3 12 36 Total Proposed Watts= 1143 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2020 New York State Energy Conservation Construction Code requirements in Project Title: Report date: 08/11/23 Data filename: Page 1 of 6 COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Jackie Brousseau - Project Manager U?eadzg 4 8/11/2023 Name-Title Si ture Date Project Title: Report date: 08/11/23 Data filename: Page 2 of 6 1 COMcheck Software Version COMcheckWeb il Inspection Checklist Energy Code: 2020 New York State Energy Conservation Construction Code inA Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans,specifications,and/or ❑Complies [PRO calculations provide all information ❑Does Not with which compliance can be determined for the interior lighting :Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 08/11/23 Data filename: Page 3 of 6 Section Rough-In Electrical Inspection - Complies? Comments/Assumptions & Req.ID C405.2.2. ;Spaces required to have light- EComplies 2 ;reduction controls have a manual ElDoes Not [EL22]1 ;control that allows the occupant to ;reduce the connected lighting load in ❑Not Observable a reasonably uniform illumination ❑Not Applicable ;pattern >= 50 percent. C405.2.1, Occupancy sensors installed in ❑Complies C405.2.1. classrooms/lecture/training rooms, ❑Does Not 1 conference/meeting/multipurpose [EL18]1 rooms,copy/print rooms, ❑Not Observable lounges/breakrooms,enclosed offices, ❑Not Applicable open plan office areas, restrooms, storage rooms, locker rooms, • warehouse storage areas,and other spaces<= 300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. C405.2.1. Occupancy sensors control function in ❑Complies 2 warehouses: In warehouses,the ❑Does Not [EL19]1 lighting in aisleways and open areas is controlled with occupant sensors that ❑Not Observable automatically reduce lighting power ❑Not Applicable by 50%or more when the areas are unoccupied.The occupant sensors control lighting in each aisleway independently and do not control lighting beyond the aisleway being controlled by the sensor. C405.2.1. Occupant sensor control function in ElComplies 3 open plan office areas: Occupant ❑Does Not [EL20]1 _sensor controls in open office spaces :Not Observable >= 300 sq.ft. have controls 1) ❑Not Applicable configured so that general lighting can i e be controlled separately in control zones with floor areas<= 600 sq.ft. within the space, 2)automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space, 3)are configured so that general lighting power in each control zone is reduced by>= 80%of the full zone general lighting power within 20 minutes of all occupants leaving that control zone, and 4)are configured such that any daylight responsive control will activate space general lighting or control zone general lighting only when occupancy for the same area is detected. C405.2.2, ;Each area not served by occupancy ❑Complies C405.2.2. 'sensors(per C405.2.1) have time- ❑Does Not 1, ;switch controls and functions detailed C405.2.2. i in sections C405.2.2.1 and C405.2.2.2, ['Not Observable 2 ❑Not Applicable [EL2112 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 08/11/23 Data filename: Page 4 of 6 Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.3, ;Daylight zones provided with ❑Complies C405.2.3. (individual controls that control the ❑Does Not 1, ;lights independent of general area C405.2.3. :lighting.See code section C405.2.3 ['Not Observable 2 ;Daylight-responsive controls for ❑Not Applicable [EL23]2 ;applicable spaces,C405.2.3.1 Daylight responsive control function and ;section C405.2.3.2 Sidelit zone. C405.2.4 Separate lighting control devices for ❑Complies [EL26]1 specific uses installed per approved ElDoes Not lighting plans. ❑Not Observable ❑Not Applicable C405.2.4 ;Additional interior lighting power DComplies [EL27]1 allowed for special functions per the DDoes Not ;approved lighting plans and is :automatically controlled and ['Not Observable ;separated from general lighting. ❑Not Applicable C405.3 Exit signs do not exceed 5 watts per ❑Complies [EL6]1 face. ODoes Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 08/11/23 Data filename: Page 5 of 6 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, :Furnished O&M instructions for ❑Complies C408.2.5. 'systems and equipment to the ❑Does Not 2 !building owner or designated [FI17]3 ;representative. ['Not Observable ❑Not Applicable C405.4.1 Interior installed lamp and fixture EComplies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting plans, demonstrating proposed watts ['Not Observable are less than or equal to allowed ❑Not Applicable watts. C408.2.5. ;Furnished as-built drawings for ❑Complies 1 :electric power systems within 90 days ❑Does Not [FI16]3 ;of system acceptance. ['Not Observable ❑Not Applicable C408.3 'Lighting systems have been tested to ❑Complies [FI33]1 ensure proper calibration, adjustment, ❑Does Not programming,and operation. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 08/11/23 Data filename: Page 6 of 6 FIRE MARSHAL'S OFFICE w_ 1Olekt Town of Queensbury FA 1 742 , NY 12804 Bay Road, Queensbury, "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Dunkin Donuts FILE COPY 713 Glen Street CC-0466-2023 8/2/2023 The following comments are based on review of drawings: • Verify fire extinguisher location, • Verify storage at time of CO walk through • Exit and Emergency lighting will be verified, including exterior emergency lighting. All breakers clearly marked for function test of the fixtures. • Locks / latches on egress doors to be compliant with Chapter 10 of the IFC. Key locks and thumb turns are not accepted. • Contractor shall be responsible for protecting all existing fire alarm and extinguishing equipment, and the prevention of unintentional alarms. Any / all impairments or out of service conditions, shall be advised to the FM office. (Chapter 33 Fire Code) • NFPA 72 letter of compliance required for any adjustments or modifications to the fire alarm system • If a CO2 is in use, compliance with FC Se ' 5307 ts\k/e ...--s Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fire Marshal 's Office • Pitone: 518-761-8206 • F a x: 518-745-4437 firemarshal@queensbury.net • UMW.queensbuny.net T. Shaw Inc. To: Town of Queenbury NY Building Codes T. Shaw inc. is providing this letter to state we are applying for a building permit to complete interior work only at the Dunkin' Donuts located at 713 Upper Glen St.in the Town of Queensbury NY. There will be no work performed on the exterior of the building until I have received the approvals from the Town of Queensbury's Planning, Zoning and Building and Code Enforcement Departments. Thank You 9/12/23 FILE C°PY Pat Shaw 315.440.5283 Z3 ( 7' ( I ( t6 Phone: (315)696-5759 www.tshawinc.com \ Fax: (315)696-5733 Certificate of Inspection Foresight Electronic Monitoring Systems, Inc . 25 Connecticut Avenue, Queensbury, NY 12804 Name : Address Co P--" City: State: New York Fire Alarm Inspection Date: K10\jU-y\—b-e-r k—a-Q, DESCRIPTION: Inspection of Fire Alarm devices as designated below. Loca\ 0Q-)rVV1 Panel Model : QTY Correct/Incorrect Battery 2 City Connect Digital Communicator Door Release Smoke Hatch Release Elevator Recall Fan Shutdown pull Stations Smoke Detectors Duct Smoke Detectors Ca Rate of Rise Thermostats Audible/Visual devices 31 Flow or pressure devices Time delay Tamper switches other ansul Other CO Detector Signature of Inspector: comments : Cxo-L�- Aown ah — Uj V, Signature of Customer Rep: Foresight Electronic Monitoring Systems, Inc . is duly licensed by the State of New York. NYS License number 12000076730 AHARONTAN & ASSOCIATES_„INC. A r c h i t e c t s November 22, 2023 John O'Brien, Director Town of Queensbury 742 Bay Road Queensbury,NY 12804 P: 518-761-8256 www.queensbury.net Re: Dunkin Donuts 713 Upper Glen Street Queensbury,NY 12804 AA Project#22023 RE: Letter of Substantial Completion Dear Mr. O'Brien, Based on our continued involvement with this project,we are submitting this letter of substantial completion to you, attesting that the construction is in conformance with the intended design. To the best of our knowledge,this project has met all requirements within the guidelines of state and Iocal building code and regulations. If we can be of any further assistance regarding this matter,please contact us at our office. Very truly yours, Aharonian&Associates, Inc.,Architects tiR€D A �Cti P'A HAqg 0 el John AJAhnian, R.A. OF cc: Mark Smith,Building Inspector,Town of Queensbury Tom Burke,The Burke Companies 910 George Washington Highway Suite 100 Smithfield Rhode Island 02917 T 401-232-5010 F 401-232-5080 *W- 0 r N Ln M O Z WLF 1-5 RS Lands Now or Formerly of Patricia Amash Book:3477 Page:153 302.G-1-7 Concrete Walk 53°23'p0„ E 45, 00 , Crushed Stone Parking WLF 1-4 NOTES: 1.) TH15 MAP WAS, PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT OF TITLE OR AN UP TO DATE TITLE REPORT AND IS THEREFORE SUBJECT TO ANY STATEMENT OF FACTS SHOWN THEREON. 2.) NO PROPERTY CORNERS WERE SET AS PART OF THIS SURVEY. 3.) PARCEL IS SUBJECT TO ANY EASEMENTS OF RECORD. 4.) THIS MAP WAS PREPARED FROM AN ACTUAL FIELD SURVEY MADE IN ACCORDANCE WITH THE EXISTING CODE OF PRACTICE ADOPTED BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS. 5.) THIS MAP IS COPYRIGHT © 2023 VAN DUSEN * STEVES LAND SURVEYORS. UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS VIOLATION OF SECTION 7209, SUBDIVISION 2, OF NEW YORK STATE EDUCATION LAW, G.) DIMENSIONS BETWEEN PROPERTY LINES AND STRUCTURES ARE TO THE NEAREST HALF FOOT AND ARE FOR THE SOLE PURPOSE OF INTERPRETING THEIR CONFORMANCE WITH ZONING AND NOT INTENDED TO AID IN THE ESTABLISHMENT OR PRETRACEMENT OF PROPERTY LINES. 7.) UNDERGROUND UTILITIES, IF ANY, ARE NOT SHOWN HEREON. 5.) THE SURVEYED PARCEL 15 SUBJECT TO WHATEVER RIGHTS, TITLE OR INTEREST THE TOWN OF QUEENSBURY, THE COUNTY OF WARREN, AND THE PEOPLE OF THE STATE OF NEW YORK MAY HAVE TO MAINTAIN THE ROADS, AND TO WHATEVER RIGHTS, TITLE OR INTEREST THE TRAVELING PUBLIC MAY HAVE TO THE BED OF THE ROADS. 3" IPF WLF A-3 LEGEND: 0 IPF = IRON PIPE FOUND 0 CIRF = CAPPED IRON ROD FOUND 0 IRS = IRON ROD 5ET/TO BE SET M-.� = UTILITY POLE = LIGHT POLE QS = MANHOLE WV = WATER VALVE = CHAIN LINK PENCE o G = STEEL BOLLARD v = SIGN A-2 O I • WLF A- I Lands Now or Formerly of Parker Hammond Development, LLC Book:1439 Page:147 302. G- I -1 2 End ~- of Proposed Band with LED One Sto''Y Bullding Dunkin Donuts', (713 Upper Glen Street) Site Data Total Lot Area = 19,230.1 Sq. Feet Building Footprint = 2,358.5 Sq. Feet Asphalt / Concrete = 14,507.2 Sq. Feet Permeable / Green Space = 2,364.4 Sq. Feet Percent Permeable = 12.3% Zoned: CI with Travel Corridor Overla Front Yard: 75' Side Yard: 20' Min, 50' Sum Rear Yard: 25' Min. Percent Permeability = 30% Max Building Height = 40' 24.51t� o O h� End of Propose 1 d Band With LED Llyhtmy 4�� Sq, `JIaeare Bar emu_ B�„Ia._ _ _ q4" 0 ft�-N-Sft'. Q cri MAP REFERENCES: = o c� MAP OF LANDS OF 2 cL DUNKIN DONUTS OF N.Y., INC. DATED: DECEMBER 5, 1991 W V) BY: COULTER & McCORMACK o LU 0 0 CL d� O co N .-1 O VL ® Q o z U a �n vl �n v` 0 o I� M C�d � rrnn V1 b 0 cd � I N c6 O i� Dates August 01, 2023 Scale 1'-10' S-1 SHEET 1 OF 1 BURKE D3243 DWG. NO, 02-279 O J VG. b-I - I V