SOLAR-0497-2023(2) PHOTOVOLTAIC SYSTEM APPtehouse 1 n SYSTEM SIZE: ' a z NAMEPLATE: 9.72 KW DC/10 KW AC N Mn o EQUIPMENT: a - (24) REC SOLAR REC405AA PURE BLACK SERIES PV MODULES: o (405W) SOLAR MODULES w; PV OPTIMIZER(S): (24) S440 SOLAREDGE POWER OPTIMIZER f /jf ' / 1 28 Lester Dr, INVERTER(S): (1) SOLAREDGE SE1000OH-US INVERTER /fTj/ liu!T/T ;i% %T /� %1i � , � Queensbury,NY Lester Dr � /�� ire ����� � AC ��//, r �r� 1 4,United States U; COMPONENT(S): (1) 60A FUSED AC DISCONNECT y m col Z Uj W W to TYPE OF INTERCONNECTION: LINE SIDE TAP IN THE MSP U' 0 W J � SCOPE OF WORK: '°�'� a o INSTALLATION OF A CODE COMPLIANT, UTILITY INTERACTIVE LLJ _ N PHOTOVOLTAIC ELECTRIC SYSTEM. %� '��r� Uj Uj 0 AERIAL VIEW 43.320954, -73.732687 VICINITY MAP � 2017 NATIONAL ELECTRICAL CODE 1 - a LS" l Y J 2020 FIRE CODE OF NYS JOSEPH WILDEY II: 28 LESTER DR, QUEENSBURY, NY 12804, USA I 1 C. � � - `� ~ 2020 RESIDENTIAL CODE OF NYS viewed �1 N N Date, .....�.... _... . .� L. o rn 2020 BUILDING CODE OF NYS GENERAL NOTES: ELECTRICAL NOTES: W W 1. DRAWINGS ARE DIAGRAMMATIC ONLY.THE LOCATION AND ROUTING OF RACEWAYS SHALL BE 1. ALL EQUIPMENT IS LISTED FOR USE. ```G���� APPLICABLE CODE PER LOCAL AUTHORITY HAVING DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE NOTED OR STANDARDIZED. 2. MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. N Y Q 2- ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. 3. ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND /- JURISDICTION 3. IF A DISCREPANCY IN QUANTITY OR S17E OF CONDUIT,WIRE,EQWPMENT DEVICES,OVER-CURRENT LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. U O PROTECTION,GROUNDING SYSTEMS,ETC.(ALL EQUIPMENT AND MATERIALS)THE CONTRACTOR SHALL 4. AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY DE-ENERGIZE ITS BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY THE OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS 0 C STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON'ISE PLANS TO ENSURE COMPLETE OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL G COMPLIANCE WITH ALL CODES AND TO ENSURE THE LONGEVITY AND SAFETY OF THE OPERABLE PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. SYSTEM. S. ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. 4. ALL OUTDOOR EQUIPMENT SHALL BE MIN.NEMA 3R RATED. 6. ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT CALCULATED AT 5. METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE THAT COMPONENT. RUN INSIDE A BUILDING. 7. ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY 6. MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS AND AT LEAST6'ABOVE FLUSH VENTS. GROUNDED. 0 Q 7- THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS GIVEN BY UTILITY 8. DC EQUIPMENT SHALL BE 60OVDC RATED MINIMUM. W COMPANIES. 9. MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE DISCONNECT EQUIPMENT r J APPLICABLE CODES 8. FOR ADDITIONAL EQUIPMENT SPECIFICATIONS,SEE PROVIDED ETS, MIGHT BE ENERGIZED. Lij 9. ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TOO REQUIREMENTS BY NEC AND THE 10. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OR JUNCTION LOCAL A)-U.THE AHJ MAY HAVE SPECIAL LABEL REQUIREMENTS BEYOND THE SCOPE O THIS BOXES/COMBINER BOXES PER APPROPRIATE JURISDICTIONAL REQUIREMENTS. U_ Q DO DOCUMENT,THIS MAY ENCOMPASS LANGUAGE INCLUDING,BUT NOT LIMITED TO,THAT FOUND IN NEC 11. FOR ANY UNGROUNDED PV SYSTEM,A LABEL READING:"WARNING-ELECTRICAL SHOCK HAZARD. (D r _ARTICLES 690.5(C),690.14(C)(2),690,17,690,53,690.35 fl,690,54,690,64(B)(7)and 705.10. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE F- (� 10. ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES. EN ERE ENERGIZED,IUNGROUNDEDEPLACED TEACH JUNCTION ITS MAY BE EXPOSED NUR COMBINER BOX, ING DISCONNECT AND DEVICE O r z PV 1 COVER PAGE 12. INVERTER(S)SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. STRUCTURAL NOTES: 13. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. ,y � 14. THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CECINEC. V PV2 SITE PLAN pF NEW 1, MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE,BUT SHALL BE ACCURATELY SPACED. 15, BACKFED SOLAR BREAKER(S)SHALL BE INSTALLED AT THE OPPOSITE END OF THE CIRCUIT OR 2. MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY INSTRIBUTE LOAD AMONGST RAFTERS. FURTHEST AWAY FROM THE MAIN BREAKER. K. Z,q Y0 3. DO NOT SPLICE RAILS IN MIDDLE 50%OF SPAN BETWEEN TWO MOUNTS. 16. ALL WIRE,VOLTAGES,AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DATE PV3 MOUNTING PLAN P �� Cy ONLYDERA OP ER ICU)COND 17. ONLY COPPER ICU)CONDUCTORS SHALL BE USED.CONDUCTORS SHALL BE STRANDED OR SOLID QP �� WITH PROPERLY RATED CONNECTORS. O7I26�ZO23 * * Ia. DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED. PV4 STRUCTURE DETAILS r- w RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL. 19. ALL MODULES SHALL BE GROUNDED AS PER MANUFACTURER SPECIFICATIONS. 20 GROUNDED, OG JUMPERS WHERE NECESSARY ACROSS DESIGNED BY: PV5 MOUNTING DETAILS 9t t.5 O KH Fm 0 3 6 PV6-6.1 ELECTRICAL DIAGRAMS ROFESSIONP\ i 1 I OF C t LAR I-ME T PV7 MARKING& LABELS {` l rsod o(�our llmr ted cxarj)uuj[)tlana¢arrol�d(ru�ca 07/26/2023 �I i nun 1 sasy4th our caP :nits shall rat be,construed as N a ,;" a �I I� erd'ucotict p tha ia9ans and s ocs rWat6ans are lr *ATTACHMENTS fj corr�sliance wb thn :alVdo�': odes at i cw York'State. V MANUFACTURER'S SPECIFICATIONS , - .... �J... �....._._.� 3 i..13-�-23 S 7-2 23 6l e , loseph PV1 INDEX GENERAL NOTES 28 Lester Dr Roof mounted solar array 9.72 kW DC ARRAY 1 TILT:22' P-f yLINE pp,op AZIMUTH: 175' U, U) cc < cr O LINE 0 pp,op lu rn �o 45'-2" co m ARRAY SPECIFICATIONS Z uJ W>- z < U) < W G. Cf UTILITY METER C) 00 AC DISCONNECT FUSED Q v- c\I INVERTER CA >- COMBINER PANEL w z 5W�MM�NG 0 MAIN SERVICE PANEL co w FOOL 18"VENTILATION SETBACK -i mom 04 �TWIDE FIRE ACCESS PATHWAY 3'x3' GROUND LADDER ACCESS POINT C) Ljj aj 73' w-j WALK WA LEGEND co Z) IOU Uo < I W aRIVE WAY0 70 j o > ci a- < co OF NE y'. Zlc 0 Al co Z rz 0- co z (D DATE p 0 '4P2 0 rn 09 107/26/2023 LESITE R DRIVE DESIGNED BY: 07/26/2023 OKH % PV2 0 v N e h Wilde II�72oxlm Joseph Wilde II(,1zo502o7 fl J05 P Y { I .IRIDNRIDGE P y IR0NRIDGE w „e rail ;c r•a tau 28357 INDUSTRIAL eLVO..HAYWARD.G94545 78357INDUSTRIAL BLVD.,HAYWARD,CA 94545 ("° Z W � t Project Details J Bill of Materials " " O Name Joseph Wildey II Date 07/26/2023 1- Location 28 Lester Drive,Queensbury,NY 12804 Total modules 24 Part Spares Total Qty h Module REC Solar:REC405AA Pure(30mm) Total watts 9.720 Rails&Splices o U Dimensions Dimensions:71.69"x 40.0"x 1.18"(1821.Omm x 1016.Omm x 30.Omm) Attachments 46 XR-10-1688 0 12 ASCE 7-10 Rails per row 2 XR10,Rail 168"Black XR10-BOSS-01-Ml 0 8 Bonded Splice,XR10 Clamps&Grounding _ CO UFO-CL-01-B1 0 52 Universal Module clamp,Black UFO-STP-30MM-Bl O 8 ~ W W (n Stopper Sleeve,30MM,Black W Q W LUG L Grounding Lug, 0 2 '^ § (3 ` ) Grountling Lug,Low Prattle V Attachments Z DO F- INQ QM-LM•01-B1 V_ L-mount,9•x 12',Black 4 50 Ji W N BHW-SQ-02-Al 4 50 O O LWL z Square-Boll Banding Hardware 1— Accessories W FM-CM•OO1-B J Kit,4 PCs,Conduit Mount,Black 0 1 00 N QMCPC-A-12 0 1 Conduit Penetration Flashing,Mill System Weight e 04 p N Total system weight 1,212.5 W W Weightlattachment 26.4 Racking weight 127.9 Y Distributed weight 2,5 Cl) U U eQ C) Q G Roof Information Roof Material Family Comp Shingle Roof material Comp Shingle a/ O Building height 15 ft Roof attachment L-Mount(Lag Bolt) 0 J ci� < Staggered attachments Yes �! QF NEW y V > LU Roof slope 22° Attachment hardware Square �(• Zq C Q N Risk category II Gj QQ� yt 'F F_ :) = N Specific gravity 0.42 Z � 2 V Z Span Details XR10 - Portrait (J) ,_,,• Qry =07/26/2023 C-Zone Max span Max cantilever •F� eSSI1 4'5" 1'9" 2 4'5" r 9' 07/26/2023 DESIGNED BY: 3 4'S" Last updated by 44RuLSh Jangam on 072512311:14 PM Last updated by 44Rilesh Jangam on 07125R311 M14 P Page 1 of 7 Page 7 017 PV5