Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
SOLAR-0497-2023
<< Office Use Only Permit#: Permit Fee:$ e5 _ 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.queensbury.net Invoice#: .0 6 Flood Zone? Reviewed By:e/N.- SOLAR PANEL PERMIT APPLICATION SITE INFORMATION: Project Location: 28 Lester Dr Queensbury, NY 12804 Tax Map ID#: 301.13-1-23 Subdivision Name: PROJECT INFORMATION: Residential: Commercial Other: Single Family Multi-Family Are the solar panels? V Purchased Leased Estimated cost of construction: $ 12,636.00 Total System Capacity Rating (sum of all panels): /ijiieCell Solar PV System: 9.72 kW DC Select System Configuration: 1 2023 # Supply side connection with micro invertersO� J1LD �V Supply side connection with DC optimizers V � Supply side connection with string inverter Load side connection with DC optimizers Load side connection with micro inverters Load side connection with string inverter Solar Panel Application Revised January 2021 SfilitStiMer Queensburv. NY 12804 DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. I certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations. 5. A third-party electrical inspection will be completed at which time the Town of Queensbury's Building and Codes Enforcement department will be contacted to complete an inspection of the final installation of the solar panels. Please sign below to affirm that all answers are correct and that you have met all of the conditions and requirements to submit a unified solar permit. I have read and agree to the above: �i rJ 8/7/2023 Homeowner's Signature Date eha.1� a 8/7/2023 Solar Co. Representative Signature Date Solar Panel Application Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Property Owner(s): Name(s): Joseph Wildey II Mailing Address, C/S/Z: 28 Lester Dr Queensbury, NY 12804 Cell Phone:_(518 )744-4864 Land Line:_( Email:sami.wildey@gmail.com • Solar Contractor: Workers' Comp documentation must be submitted with this application Business Name: Plug PV LLC Contact Name: Chelsea Breen Mailing Address, C/S/Z: 630 7th Ave Troy, NY 12182 Cell Phone: (838 )839-1500 Land Line:_( ) Email:permits@plugpv.com/cbreen@plugpv.com • Electrical Contractor: Workers' Comp documentation must be submitted with this application Business Name: Plug PV LLC Contact Name: Steve Weigel Mailing Address, C/S/Z: 630 7th Ave Troy, NY 12182 Cell Phone: (518 )728-0284 Land Line:_( ) Email:permits@plugpv.com/cbreen@plugpv.com Contact Person for Compliance in regards to this project: Chelsea Breen-permit coordinator Cell Phone: ( 838 )839-1500 Land Line: ( ) Email: permitsi.plugpv.com/cbreen(u,plugpv.com Solar Panel Application Revised January 2021 DocuSign Envelope ID:7EDD57BA-88B9-4291-A536-C45B25E0E3D1 (518) 948-5316 HELLO@PLUGPV.COM HTTPS://WWWPLUGPV.COM PLUG PV 630 7TH AVENUE,TROY, NY 12182 LETTER OF AUTHORIZATION FOR ZONING AND PERMIT APPLICATION To Whom It May Concern: Joseph E wildey II I, as owner(s)of the property located at 28 Lester Dr, Queensbury, NY 12804 Hereby designate PlugPV,LLC.as my contractor and registered agent for the purposes of the applying for Permits and Zoning Board representation regarding my solar installation project. Joseph E wildey Print DocuSgnedptrr Sign 7/102023 Date , , Solar Panel Plan Review All wiring in conduit 1 18" from ridgeline and valleys ITwo 3' foot access ways from ground to ridge one side of roof shutdown shown /—Rapid commercial in compliance with section 1203.4 of fire code Labeling of conduit and panels " attery storage in attached garages and Utility Closets separation on wall and 5/8" on ceiling if living space above ;4 Battery storage on exterior walls located a minimum 3 feet from doors and windows. 4L1 Individual battery storage system units shall have a maximum rating of 20 kWh. The aggregate rating shall not exceed: 40 kWh within utility closets and storage or utility spaces 80 kWh in attached or detached garages and detached accessory structures 3.80 kWh on exterior walls. 4.80 kWh outdoors on the ground access isles required Id Heat detector interconnected to the smoke alarm in building P ( CRooms and areas containing battery storage systems 5/8" Type X, installed on the walls and ceiling of the room NANIndoor installations exhaust ventilation required for other than lithium-ion '__ Bollards for impact protection Revised 1/24/2022 , 1S structura ENGINEERS July 26, 2023 PIugPV LLC I o L ; 11 r 630 7th Avenue Troy, NY 12182 AUG 1 1 20 31 Subject:Structural Certification Letter Job Number: PZSE Portal# P23-1260717COH TOWN OF QUEENSBURY DES Project Name: Wildey II,Joseph - __a_BUILDING ` CO Client P0: SD5819 Address: 28 Lester Dr, Queensbury, NY 12804 Attn.:To Whom It May Concern Re: Residential Flush-Mount Solar Photovoltaic Installation PZSE's scope of work is limited to performing a structural evaluation of loading at the address above. After review, PZSE certifies that the alteration to the existing structure by installation of the PV system meets the requirements of the applicable codes and criteria shows below: Design Criteria • Applicable Codes: 2020 Residential Code of NYS,ASCE 7-16 and NDS-18 • Ground Snow Load: 50 Ib/sqft • Basic Wind Speed: 108 mph, Exposure Category B • Existing Roof Dead Load: - 7 lb/sqft • Existing Roof Live Load: 20.00 Ib/sgft The existing structure is adequate to support the PV alteration per Code Sections 502.4 and 502.5 Residential PV Module Assembly The PV module assembly including structural supporting components shall be installed in accordance with the manufacturers specifications and meets or exceeds all requirements set forth by the referenced codes above. Residential Installation Requirements The PV system shall be mounted flush to the existing roof surface.The contractor shall notify PZSE of any signs of damage to the roof framing prior to commencing the installation. PZSE shall then determine if the existing roof is adequate to support the applied loads.The electrical engineering and waterproofing system shall be addressed by others. If you have any questions on the above, do not hesitate to call. , QF NEw Zqex/ O,p •Prepared By: ,* 6Air,,� �I\ � g j PZSE, Inc.-Structural Engineers m 1 rs&l�:l�? Roseville, CA �, -/ �? '91365 ��� �19OFESSI0 1478 Stone Point Drive,Suite'190, Roseville,CA 95661 07/26/2023 T'916.961.3960 F •916.961.3965 W www:pzse.com Experience I Integrity I Empowerment • COMMONWEALTH ELECtRiCAL INgPECtiON Eft '•.I(Cri C. (Maid Omot 1.76 Doe R i Read1-Ik a►t13 P&1•7545. MUNICiPAL CERTIFICATE ZaerktICAL ArPROVAL - S -0497-2023 DD231245 _permit��...,...OLAR... , Geri. ... .. ,.•�,ttF,�tt�a���:...,,....,. ., ..�, .... I owner_.Joseph Wildey II... ....... ,.....,.».....Location 28 Lester Drive Queensbury, NY I - ns stivn C4 s1st;t� of 9 72 KW Roof Mounted PV System including (24)4.05W REC modules, • (24) P320 PV Optimizers, (1) SE10000H 10 KW inverter, m - (1)60A AC disconnect, and all associated conduit and conductors. Installed By Plug PV .............. • ... , •--.... , . . Lie No, The.corditions following goi,ern d the is .urxnee fthis.ee tafica e..an#any certificate;prev sty iskked is canceller!!:- T#tit certificate oily x ers the'electrical equipment-end installation.vogditiorts as i fdate. !span rlre Sa3t�oducti cif additi6ual equipmenr or alterations, alma be Oiorpity.ma(t$ror frespectkp. In .ctors of this. Company shad have the, privilege of tthkipg Aitspittibris t ai{y ti i ,• 0'6 .4' }t rules!are vxotated,the CCrnpgny shall have ths right to revoke rhis ct~rtifcate. • Dale...............September 26,,2023,,.`- INSP TO Z7G[�YL81ii V Q 8 • . 'OCT 0 2 2023. TOWN.OF QUEENSBURY • BUILDING& CODES • • I ' _ • I • Thy, s structura ENGINEERS July 26, 2023 PIugPV LLC it.1 (c-7. y A �.... ..' 630 7th Avenue T m- - ___..Troy, NY 12182 � 1. ., Subject: Structural Certification Letter Job Number: PZSE Portal# P23-1260717C0H TO' l�N OF QUFENSBURY Project Name: Wildey II,Joseph SW! DING CO Client P0: SD5819 Address: 28 Lester Dr, Queensbury, NY 12804 Attn.:To Whom It May Concern Re: Residential Flush-Mount Solar Photovoltaic Installation PZSE's scope of work is limited to performing a structural evaluation of loading at the address above. After review, PZSE certifies that the alteration to the existing structure by installation of the PV system meets the requirements of the applicable codes and criteria shows below: Design Criteria • Applicable Codes: 2020 Residential Code of NYS,ASCE 7-16 and NDS-18 • Ground Snow Load: 50 lb/sqft • Basic Wind Speed: 108 mph, Exposure Category B • Existing Roof Dead Load: 7 lb/sqft • Existing Roof Live Load: 20.00 lb/sqft The existing structure is adequate to support the PV alteration per Code Sections 502.4 and 502.5 Residential PV Module Assembly The PV module assembly including structural supporting components shall be installed in accordance with the manufacturers specifications and meets or exceeds all requirements set forth by the referenced codes above. Residential Installation Requirements The PV system shall be mounted flush to the existing roof surface.The contractor shall notify PZSE of any signs of damage to the roof framing prior to commencing the installation. PZSE shall then determine if the existing roof is adequate to support the applied loads.The electrical engineering and waterproofing system shall be addressed by others. If you have any questions on the above, do not hesitate to call. - of NEyy J\ ZAcyy�'A N W c� 1 Prepared By: (6,r�sl ��, PZSE Inc.-Structural Engineers Roseville, CA rtip\rg2— '43LiFESSIO" , 1478 Stone Point Drive,Suite 19.0, Roseville,CA 95661 07/26/2023 T 916.961.'3960 F 916.961.3965 W www.pzse.com Experience I Integrity I Empowerment 0,4_,,,,„:--,y,H....;.::.:._.__-:,_ 1,:i._ _,_ RE Cm a SOLAR'S MOST TRUSTED' � :rd n a t R fi - r • - , k; aa;R s 4 r j 1-:, ..:_,I,.._,T.,-_,i. . x x fi r �� -- - ----- —- r j J ;t r �J 4F . / Vgg LL Pi - -.'-:. r‘ REE ALPHOC PURE a _ __(__ _ 5EE- T s � hBLACK y .. __ .,,,,,.... .. ...„.,,,„,:. PRODUCT SP DF.� f s � r SLY.. 3 .* , =''''.-. }hT+ A'�••�' .... ,„ ,„„ . ,., ,...„.., 77- a EXPERIENCE 400 WP 'r` 25 YEAR ,, . : v PROTRUST �a W i -` WARRANTY 20.E /T2 Q LEAD-FREE ELIGIBLE ROHS COMPLIANT PERFORMANCE [-C PRODUCT SPECIFICATIONS SOLAR'S MOST TRUSTED •I• •-r 4 :,w 0_ea>-1+■...- , I 1821±2.5[71.7±0.1] • 28[1.1] 901[35.5] 460[18.1] '-CERTIFICATIONS A .,a,_ o ° • ,✓ IEC 61215:2016,IEC 61730:2016,UL 61730(Pending) ® � + / 15014001:2004,ISO 9001:2015,OHSAS 18001:2007,IEC 62941 1100[43.3] °®- C E o f"a tntertek 6.0±0.2 [0.24±0.01] -- l +; WARRANTY e▪l qQ,I oV. od m Standard RECProTrust �i Installed byan REC Certified No Yes Yes :Si 11±0.2 -. Solar Professional - [0.43±0.01] System Size All 425 kW 25-500 kW I Product Warranty(yrs) 20 25 25 j -- Power Warranty(yrs) 25 25 25 I F' 20.5±0.5 j o [0.8±0.02] 1111-" 1200[47.2] Labor Warranty(yrs) 0 25 10 l.--- / ° 1 Power in Year 1 98% 98% 98% - ° _ _ ° Annual Degradation 0.25% 0.25% 0.25% 671±3[26.4±0.12] 22.s[0.9] 92% -�.-as[t.s] � � I Power in 92% 92% 1 _ 1130[1.2] See warranty documents for details.Conditions apply Measurements in mm lin] I Ise o GENERAL DATA L MAXIMUM RATINGS 132ha1f-cutRECheterojunctioncells Staubli MC4 PV-KBT4/KST4,12AWG(4 mm2) Operational temperature: -40...+185°F(-40...+85°C) Celltype: with lead-free,gapless technology Connectors: in accordance with IEC 62852 Maximum system voltage: 1000V 6strings of 22 cells in series IP68 only when connected Maximum test load(front): +7000 Pa(146 lbs/sq ft)• 0.13 in(3.2 mm)solar glass with 12AWG(4mm2)PVwire,43+47in(1.1+1.2m) Glass: Cable:anti-reflection surface treatment accordance with EN 50618 Maximum test load(rear): 4000Pa(83.5lbs/sgft)' Backsheet: Highly resistant polymer(black) Dimensions: 71.7 x40 x1.2 in(1821 x1016 x 30 mm) Max series fuse rating: 25A Max reverse current: 25 A 5 Frame: Anodized aluminum(black) Weight: 45 lbs(20.5 kg) 'See installation manual for mounting instructions. + Design load=Test load/1.5(safetyfactor) .2 Junction box: 3-part,3bypassdiodes,IP67rated Origin: Made in Singapore 3 in accordance with IEC 62790 co c ro c • ELECTRICAL DATA Product Code':RECxxxAA Pure Black TEMPERATURE RATINGS' 2 Power Output-PMAX(Wp) 385 390 395 400 405 Nominal Module Operating Temperature: 44°C(±2°C) Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+5 0/+5 Temperature coefficient ofPMAx: -0.26%/°C o Nominal Power Voltage-V,,,(V) 41.2 41.5 41.8 42.1 42.4 Temperature coefficient ofVcc: -0.24%/°C u F Nominal Power Current-IMPP(A) 9.35 9.40 9.45 9.51 9.56 Temperature coefficient ofloC: 0.04%/°C in Open Circuit Voltage-Voc(V) 48.5 48.6 48.7 48.8 48.9 'The temperature coefficients stated are linear values Short Circuit Current-I5,(A) 9.99 10.03 10.07 10.10 10.14 Power Density(W/sgft) 19.3 19.6 19.8 20.1 20.3 - LOW LIGHT BEHAVIOUR Panel Efficiency(%) 20.8 21.1 21.3 21.6 21.9 Typical low irradiance performance of module at STC: ,, m 0 Power Output-PMAS(Wp) 293 297 301 305 309 I < Nominal Power Voltage-VMPP(V) 38.8 39.1 39.4 39.7 40.0 a � m m o 2 Nominal Power Current-IMPP(A) 7.55 7.59 7.63 7.68 7.72 m --_ N Z ito Open Circuit Voltage-Voc(V) 45.7 45.8 45.9 46.0 46.1 ' °' • Short Circuit Current-I5,(A) 8.07 8.10 8.13 8.16 8.19 Irradiance(W/m2) v x Values at standard test conditions(STC:air mass AM 1.5,irradiancel0.75 W/sq ft(1000 W/m2).temperature77°F(25°C),based on a production spread with a tolerance ofPwa,Voc&15C±3%within one watt class Nominal module operating temperature(NMOT:air mass AM1.5,irradiance 800 W/m',temperature 68°F(20°C),windspeed 33 ft/s(1 m/s).*Where xxx indicates the nominal power class(PM*x)at STC above. - Founded in 1996,REC Group is an international pioneering solar energy n r C company dedicated to empowering consumers with clean,affordable I� solar power.As Solar's Most Trusted,REC is committed to high quality, • innovation,and a low carbon footprint in the solar materials and solar www.recgroup.com panels it manufactures. Headquartered in Norway with operational (]; 71:1 - headquarters in Singapore,REC also has regional hubs in North America, �' Europe,and Asia-Pacific. FF Power Optimizer 0 For Residential Installations S440 / S500 / S500B m 2.5 YEAR . WARRANTY N f � m aC7 Enabling PV power optimization at the module level / Specifically designed to work with SolarEdge I Mitigates all types of module mismatch loss,from residential inverters manufacturing tolerance to partial shading I Detects abnormal PV connector behavior, / Faster installations with simplified cable preventing potential safety issues* management and easy assembly using a single bolt I Module-level voltage shutdown for installer I Flexible system design for maximum space and firefighter safety utilization / Superior efficiency (99.5%) / Compatible with bifacial PV modules •Functionality subject to inverter model and firmware version / Power Optimizer For Residential Installations S440 / S500 / S5006 S440 S500 5500B UNIT INPUT Rated Input DC Powert't 440 • 500 W Absolute Maximum Input Voltage(Voc) 60 125 Vdc MPPT Operating Range 8-60 12.5-105 Vdc Maximum Short Circuit Current(Isc)of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 Weighted Efficiency 98.6 Overvoltage Category II OUTPUT DURING OPERTION Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1±0.1 Vdc STANDARD COMPLIANCE(z) EMC FCC Part 15 Class B,IEC61000-6-2,IEC61000-6-3,CISPR11,EN-55011 Safety IEC62109-1(class II safety),UL1741 Material UL94 V-0,UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions(W x L x H) 129 x 155 x 30 I 129 x 155 x 45 mm Weight(including cables) 655 gr Input Connector MC4t3t Input Wire Length 0.1 m Output Connector MC4 Output Wire Length (+)2.3,(-)0.10 m Operating Temperature Ranget4t -40 to+85 'C Protection Rating IP68 Relative Humidity 0—100 (1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power.Modules with up to+5%power tolerance are allowed. (2)For details about CE compliance,see Declaration of Conformity—Cf. (3)For other connector types please contact SolarEdge. (4)For ambient temperature above+70°C power de-rating is applied.Refer to Power Optimizers Temperature De-Rating Technical Note for details. PV System Design Using a SolarEdge SolarEdge Home Three Phase Three Phase for Three Phase for Inverter(5) Wave Single Phase . SExxK-RWB 230/400V Grid 277/480V Grid Minimum String Length S440,S500 8 9 16 18 (Power Optimizers) S500B 6 8 14 Maximum String Length(Power Optimizers) 25 20 50 Maximum Continuous Power per String 5700 5625 11250 12750 W Maximum Allowed Connected Power per String (Permitted only when the power difference between strings is Seet6) See(6) 13500 15000 W less than 2,000V) Parallel Strings of Different Lengths or Orientations Yes (5)It is not allowed to mix S-series and P-series Power Optimizers in new installations. (6)If the inverter's rated AC power s maximum nominal power per string,then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to Application Note'Single Strino Design Guidelines. • — m EVo Figrzi I al I •45mm for S500B Single Phase Inverter with HD-wave Technology rn for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US \ rn 12-25 f — YEAR — — -- — — ® WARRANTY ® �I O 0 1 E I O solar �tih�.rowe solar,[' 4 1tp !O i 0 ' O A I MP Optimized installation with HD-Wave technology / Specifically designed to work with power optimizers / UL1741 SA certified,for CPUC Rule 21 grid compliance / Record-breaking 99%weighted efficiency / Small, lightweight, and easy to install both outdoors or indoors / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Built-in module-level monitoring / Fixed voltage inverter for longer strings / Optional: Faster installations with built-in consumption metering (1% accuracy) and / Integrated arc fault protection and rapid shutdown production revenue grade metering (0.5%accuracy, for NEC 2014, NEC 2017 and NEC 2020 per article ANSI C12.20) 690.11 and 690.12 solaredge.com solar - 1 • !' / Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US 4 APPLICABLE TO INVERTERS I WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ I ✓ ✓ ✓ Vac (211-240-264) AC Output Voltage Min. Nom. Max. I ✓ - - ✓ Vac - (183-208-229) AC Frequency(Nominal) 59.3-60-60.5m Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output 16 24 - 48.5 A - Current©208V Power Factor 1,Adjustable-0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240VPPI 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V0 - 9 - 13.5 - - 27 Adc • Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency 99 99.2 % 40V CEC Weighted Efficiency 99 98.5 @2208V Nighttime Power Consumption <2.5 W (1)For other regional settings please contact SolarEdge support (2)A higher current source may be used;the inverter will limit its input current to the values stated I Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER I SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Metering,ANSI C12.20 Optionalai Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown-NEC 2014,NEC Automatic Rapid Shutdown upon AC Grid Disconnect 2017 and NEC 2020,690.12 STANDARD COMPLIANCE Safety ((UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07, ) Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/mm Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+60 °F/°C Protection Rating NEMA 4X(Inverter with Safety Switch) (3)Inverter with Revenue Grade Meter P/N:SEmocxxH-US000BNC4;Inverter with Revenue Grade Production and Consumption Meter P/N:SEwxciH-US000BN14.For consumption metering,current transformers should be ordered separately:SEACT0750-200NA-20 or SEACT0750-400NA-20.20 units per box (4)Full power up to at least 50'C/122'F;for power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with HD-wave technology and built-in RGM and Service Panel consumption monitoring o ® Grid o o idCI LIT Y G d CT L1 N L2 Shielded CATSe cable /1111111111111.1.1110_ uvismommi 12 I -, Jarliny AC Conduit O SolarEdge Technologies,Inc All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc All Ro H7LJ other trademarks mentioned herein are trademarks of their respective owners.Date:12/2020N01/ENG NAM.Subject to change without notice. Z17%, IRON RIDGE XR Rail Family Solar Is Not Always Sunny eAts, Over their lifetime, solar panels experience countless ®� extreme weather events. Not just the worst storms in years, ,,'�\. but the worst storms in 40 years. High winds capable of \'��®� ® ripping panels from a roof, and snowfalls weighing / ® ®®`�� ,_, enough to buckle a panel frame. �,. 4 � --Allip��� ®, \ XR Rails are the structural backbone preventing .,- ,`` -. ���® these results. They resist uplift, protectW �;.: 7� ��M�! against buckling and safely and efficiently `� . �'�., ��� ®� transfer loads into the building structure. ' .,-*, "-,.....- s`- � ® Their superior spanning capability f`— `` `` ". requires fewer roof attachments, `-:= 'Y `iters:,--,......... `' � reducing the number of roof �`;� F~ ` -, ,,,,,,,, ........% 1 enetrations and the amount .� ' �... of installation time. - _ �� `� ! t :tr..-_)** ,„,. , '',,,-.., -.A.44,:.., --- Force-Stabilizing Curve {ftr li Sloped roofs generate both vertical and lateral i *,. �-- `---`-- `` forces on mounting rails which can cause them . _ : - - 1 , to bend and twist.The curved shape of XR Rails a=tV.• -' (Si. is specially designed to increase strength in both .4; ,,4-771. �� ; directions while resisting the twisting.This unique ' feature ensures greater security during extreme ti..t,„_. ., tz,; --> ,- . „.g.---r,.,,,,:,,,,,, weather and a longer system lifetime. %' ` . 1,4,-?.,!.- - -s- f tin. �F-n • Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials XR Rails are IronRidge offers All XR Rails are made of 6000-series Ia;', n� compatible with ® ;m '4 a range of tilt leg aluminum alloy,then protected with an FlashFoot and options for flat anodized finish.Anodizing prevents surface other pitched roof ® . roof mounting and structural corrosion,while also providing attachments. _µ applications. a more attractive appearance. A wisimmaiim XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. ----TEg\, ---_---- "`- —�Ili , i --' r XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail,designed for regions with light or mounting rail. It supports a range of solar mounting rails.It's built to handle no snow. It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. • 6'spanning capability • 10'spanning capability • 12'spanning capability • Moderate load capability • Heavy load capability • Extreme load capability • Clear&black anodized finish • Clear&black anodized finish • Clear anodized finish • Internal splices available • Internal splices available • Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load Rail Span Snow(PSF) Wind(MPH) 4' 5'4" 6' 8' 10' 12' I x- , 120 _, None __ - - __ rk 140 XR10 XR100 MAN 0004�� ' (— , 160 ; i :> i- r - 120 t p s 20 i - , - _ 140 --- . "` •z.1-115 1 , 160 1 -Ail ; 160 T- ,,,,,,,,,,,,0 160 I :. ,_ :- -'7z- Y1 120 160 i :* .. ,i� *Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. E - - 1 • 3 IRON RIDGE L-Foot 0 <C ITEM NO DESCRIPTION QTY IN KIT 1 FOOT, EXTRUDED L-SLOTTED 4 PART NUMBER DESCRIPTION FM-LFT-003 Kit, 4Pcs, Slotted L-Foot, Mill FM-LFT-003-B Kit, 4Pcs, Slotted L-Foot, Black 1) Foot, Extruded L-Slotted -0-.40-•••- .42 - 1.92 .35 -+- .94 H- .40-0- f 1.22 3.00 .31 _ 1 -1.92-NH -�-1.88---0-1 v1.11 74, k.