IM Inspection Worksheet_16-11-2023_08-39-09INSPECTION WORKSHEET (SEP-028881-2023) CC-0241-2023Case Number:Case Module:Permit Management 11/16/2023 Partial PassInspection Status:Inspection Date: SepticInspection Type:Inspector:Mark Smith Job Address:Parcel Number:355 Dix Ave Queensbury, NY 12804 303.15-1-27 Company Name NameContact Type Applicant Blueprint Engineering and Desing LLC Contractor Hunt Companies Inc Engineer Blueprint Engineering and Desing LLC Granted Permission Hospitality Syracuse Inc Primary Owner Hospitality Syracuse Inc Checklist Item CommentsPassed Building Inspector Notes False 10/26/23 partial approval of septic system. - placement of 1000 gallon grease trap, 2000 gallon septic tank and 1000 gallon pump tank only. - Alarms and float switches have not been verified. - baffles at grease trap and septic tank have not been installed at time of inspection. 11/16/23 partial approval for septic system. - placement of absorption field verified. - operation of sump chamber and alarms verified. - flow to D- box verified - final electrical inspection verified. - Engineer on site at time of inspection. Items remaining. - Submit as built drawing and letter of substantial completion from design engineer. - verify final grading at raised absorption field. Soil Type: Sand True Size of Stone True # 2 Final Electrical True Roof gutters don't discharge over leach field True Waterline separation distance True Building to Tank True 4' sch 40 from building to septic tank with clean out. 4' sch 40 connecting grease tank to septic tank. both septic and pump tank are vented. [Provide extension collar if Yes]True Tank to Distribution Box True 2" forced main PVC Opening Sealed:True 90% alarm level activates True End Cap True Absorbtion Fields: Total Length True 10 laterals at 100' each, 1000' total. Septic system field above flood plain True Foundation to Tank False Engineer Report and As-Built True provide as built drawing Inlet & Outlet manholes 12"+ below grade True November 16, 2023 Page 1 of 2 INSPECTION WORKSHEET (SEP-028881-2023) Checklist Item CommentsPassed Water softener not connected to septic system True Type of Water: Municipal / Well Water True municipal water supply Locations / Separations True Depth of Trenches True 12/16" Length of Each Trench True 10 laterals at 100' each, 1000' total. System Use Status True system approved for use Conforms as per Plot Plan True Size of tank True 1000 gallon grease tank, 1000 gallon pump tank, 2000 gallon septic tank. Distribution box to Field / Pit True 4" D S 3000 PVC perforated Foundation to Absorption False InletOutlet Pipes & Baffles True November 16, 2023 Page 2 of 2