Loading...
AST-0571-2023 Office Use Only ) ACCESSORY STRUCTURE Permit#:AST-0571-2023 Townf „b ry PERMIT APPLICATION Permit Fee:$1 40.00 742 Bay Road,Queensbury,NY 12804 Invoice#: 6527 P:518-761-8256 www.queensbury.net Flood Zone? Y Reviewed By: KS Project Location: 441 Lockhart Mtn Road - Unit 12 Tax Map ID#: 252.39-1 -1 Subdivision Name: N/A PROJECT INFORMATION: TYPE: B Residential ❑ Commercial, Proposed Use: STRUCTURE: ❑ Boathouse(with or w/o sundeck) ❑ Canopy ❑ Carport ❑ Cell Tower ® Deck ❑ Detached Garage(>300 s.f.) ❑ Dock El Gazebo ❑ Pavilion ❑ Pole Barn ❑ Porch ❑ Ramp ❑ Shed (<300 s.f.) ❑ Solar Panels (w/o rafter upgrades) ❑ 3-Season Porch El Other: SQUARE FOOTAGE OF STRUCTURE: 1st floor: 348 SQFT 2nd floor: 144 SQFT Total square feet: 492 SQFT Brief description of scope of project: Removal and replacement of both 1st and 2nd level deck. *Plans attached to application Accessory Structure Application Revised June 2022 � 1 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction:$50,000.00 2. Are there any structures not shown on the plot plan? ❑ YES 0 NO Explain: 3. Are there any easements on the property? ❑ YES RI NO DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. I certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Northern Builders - Nicholas Denno SIGNATURE: DATE: 09/08/2023 Accessory Structure Application Revised June 2022 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Northern Builders Mailing Address, C/S/Z: 33 Atwell Road, Porter Corners NY 12859 Cell Phone: 5187966694 Land Line: N/A Email: ndenno@northernbld.com • Primary Owner(s): Name(s): Kathyrn & Michael Stango Mailing Address, C/S/Z: 441 Lockhard Mtn Road Lake Geroge NY 12845 Unit 12 Cell Phone: 412-480-6659 Land Line: Email: mestango@gmail.com ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contractor Name(s): Northenr Builders Contractor Trade: General Contractor /Builder Mailing Address, C/S/Z: 33 Atwell Road Porter Corners NY 12859 Cell Phone: 518-796-6694 Land Line: N/A Email: ndenno@northernbld.com **Workers' Comp documentation must be submitted with this application** • Architect(s)/Engineer(s): Business Name: Engineering America Contact Name(s): Geroge Yasenchak Mailing Address, C/S/Z: 76 Washington Street Saratoga Springs NY 12866 Cell Phone: N/A Land Line: 518-587-1340 Email: georgeyas3@yahoo.com Contact Person for any questions regarding this project: Nicholas Denno-Northern Builders Cell Phone: 518-796-6694 Land Line: N/A Email: ndenno@northernbld.com Accessory Structure Application Revised June 2022 lM REVISION zi ACY WALL MIN.4x4 P.T. POST INSIDE PRIVACY WALL CONTINUOUS FROM BEAM TO FOUNDATION NEW (3)1-314"X 16"ML BEAM - COVER IN CEDAR C NOTE: THiS SPAN CANNOT EXCEED 19"--6" ADJUSTANGLES ACCORDINGLY SPECIAL NOTE: CONTRACTOR TO VERIFY THAT A POST EXISTS IN THE PRIVACY WALL PRIOR AND NOTIFY ENGINEER IF ONE DOES NOT EXIST Alt #2 - Upper Deck Beam Scale: 114" = 1'--0" CAULK AROUND WHERE BEAM ENTERS PRIVACY WALL PRIVACY WALL -------------------------------------- (a__,Foundation Plan Scale: SHEET A-2 NOTE: (4) SIMPSON HOLD DOWS SHALL BE INSTALLED (1) AT EACH END AND THE OTHER 2 EQUALLY SPACED ACROSS LENGTH OF DECK TIE -DOWNS CAN BE APPLIED TO EITHER THE SIDE OR THE BOTTOM OF THE JOISTS 2x8 P. T. FJ`_,/ 16-in oc (2)2x10P.T. FACE BOARD Upper Deck Framing Plan Scale: 114" = V-0" 2nd Floor Deck - Demo Plan Scale: 114" = 1 "-0" Existing 2nd Floor Deck Scale: 114" = 1'-0" SIMPSON OR EQUAL LUS26 OR EQUAL EACH FJ WALL PRIVACY WA POST FOR 2nd LOCATE PRIVAC` VACY WALL PRIVACY WALL VACY WALL PRIVACY WALL f'AGL BOARD @16-in cc B0LDBENCH SAME AS EXISTING �� 9 st Floor Deck Framina Plan AFTER 2ND LEVEL IS REMOVED Ist Floor Deck - Demo Plan Existing 1st Floor Deck Scale: 114" = 1 "-0" SPECIAL NOTES: 1. Contractor shall walk through each unit that will be receiving a new decks) and observe and cracks or other imperfections. The Contractor shall be accompanied on this walk through by the Owners representative. Photos and notes will be taken and made part of the Construction Documents. 2. The Contractor, with the Owner's representative present, shall observe and examine the existing rim boards (not the ledger boards) for both the first floor deck and the second floor deck If they are deemed `unacceptable' by both the Contractor and the Owners representative, they shall be 31MPSON removed and replaced prior to beginning construction of he iAL HANGERS decks. FACE BOARD General Design Criteria 1. Seismic design category - C 2. Concrete weathering probability - Severe 3. Design wind speed - 90 mph 4. Design ground snow load - 60-psf 5. Termite infestation - Slight to moderate 6. Decay probability - Slight to moderate 7. Exposure category - B 8. Wind-borne region - No General Design Loads Deck Floor Load - 60-psf live load plus dead load NOTES: 1. Should the project become delayed for any reason, and the time between the beginning of the project and the date stamped by the Engineer exceed one (1) year the plans must be reviewed for NYS Code changes by a licensed NYS Engineer or Architect prior to beginning construction. 2. All construction shall comply with the 2Q&dResidential Code of New York State and the Energy Conservation Construction Code of New York State. 3. The contractor/owner shall comply with all laws, rules and ordinances of any public authority bearing on the performance of the work. 4. The contractor is solely responsible for all construction means, methods, techniques, sequences and procedures and for the coordination of all portions of work. 5. The Engineer is not responsible and is to be held harmless by the owner from any claim or suit whatsoever, including all payments or costs involved arising from or alleged to have arisen from the contractor's work to conform to design intent. 6. All measurements to be job /field verified and advise Engineer of any discrepancies prior to proceeding. 7. Drawings not to be scaled from for field work purposes. 8. All stairs: a. Max rise 8 %" b. Min run 9" c. Nose 1 1/8" Handrail & Guard Notes: 1. Handrails shall be provided on at least one (1) side of each continuous run of treads or flight with four (4) or more risers. 2. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, shall be not less than 34-inches and not more than 38-inches. 3. Handrails for stairways shall be continuous for the full length of the flight, from a point directly above the top riser to a point directly above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. 4. Handrail Grip: a. Type 1. Circular cross section shall have an outside diameter of at least 1-114" but not greater than 2". 5. Guards shall be located on all porches, balconies, ramps or raised floors located 30-in or more above grade. 6. Guard height shall be not less than 36-inches. 7. Intermediate rails and spindles shall be placed so as not to pass a sphere 4-inches or greater. TOWN Or Q' EEiv,3URy BUILDING DEPARTMENT Eased on our limited examination, compliance V;:t,, our comments shail not be construed as i. ;%-.atin the plans and sppeci cations are in 9 B •'d'n Codes of ABBREVIATIONS AFG Above Finish Grade BFG Below Finish Grade DJ Deck Joist FJ Floor Joist FV Field Verify ft Foot / Feet in Inch / Inches Max Maximum Min Minimum_ ML _ Microlam oc On Center P.T. Pressure Treated SS Stainless Steel ST Sonotube TBD To Be Determined compliance with the u�� g Ne-j Ywk 6tatr 252.48-1-4 AST-0571-2023 Stango, Michael & Kathlyn 12 Top of the World BILE COP` Deck repair, upper and lower 1 OQ % Drawings For Construction TOWN OF QUENSBURY BUILDING & CODES Typical Unit Deck Plans ReviewedBy'. Ian Views & Typ. Section Date:__ q IF Scale: 114" = 1'-0" M+1 �i P4 w W W O I 00 aD q c,Q aD c�z Z rr� z 0-4 O H M z O E--+ z cfl r- � L o� p00`f>O p, OCV� N70 C� O o ^- � UN , UyaD UfC'OC O �O)�N�C O�Oiy 0U O WOONW2 c'(0L <r'C Op +N Lc N O��-O "q O0, Q 6 o c-a ca am ic or0cto� �°c� 0) O cfn 2 viNis iri.N33�� aci ?m�as 0 Z- N M NCw C 8� ec�4�c•`° w m•v, � cn roaLk DRAWN gy DATE August 28, 2023 PROJECT NO. 22-0131 SHEET NO. A-1