Loading...
1986-853 CERTIFICATE OF OCCUPANCY TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK May 31, . Date 19 _ This is to certify that work requested to be done as shown by Permit No. 86-853 has been completed. This structure may be occupied as a One-Family Dwelling Lot 51 Queens Lane (St. No. 25) Van Howe Estates Location Classic Home Builders, Inc. Owner.. By Order Town Board TOWN OF QUEENSBURY • Building Er Zoning Inspector • • BUILDING PERMIT TOWN OF QUEENSBURY No. 86-853 WARREN COUNTY, NEW YORK PERMISSION is hereby granted to Classic Home Builders Inc. w OWNER of property located at Lot 51 Queens Lane (St. No. 25) Street, Road or Ave. N. One—Family Dwelling x in the Town of Queensbury,To Construct or place a at the above location in accordance to application together with plot plans and other information hereto filed and co approved and in compliance with the Town of Queensbury Building and Zoning Ordinance. H. 1. OWNER'S Address is Box 112A N ri East Berne, NY 12059 CD H 2. CONTRACTOR or BUILDER'S Name Same cr • o 3. CONTRACTOR or BUILDER'S Address rt O H Same • A t1fD cD 4. ARCHITECT'S Name r�r • m rt ct Cr) W m 5. ARCHITECT'S Address rt 0 6. TYPE of Construction—(Please indicate by X) IV Ln (x)Wood Frame ( ) Masonry ( )Steel ( ) v 7. PLANS and Specifications 0 No. 24'x68' per plot plan, specifications and application submitted including sewage system and two—car attached garage. cif 0 8. Proposed Use N One—Family Dwelling CD 0 $5.00 C/O H. $ 136.00 PERMIT FEE PAID —THIS PERMIT EXPIRES July 1 19 87 vg (If a longer period is required an application for an extension must be made to the Building and Zoning inspector of the town of Queensbury before the expiration date.) Dated at the Town of Queensbury this 12th Day of December 19 86 SIGNED BY 7h� Legfor the Town of Queensbury Building and Zoning Inspect r �!%' TO BE COMPLETED BY BLDG. DEPT. Application No. gown ofQuecniur Permit Issued 19 T OWOUE NSIS PY 1 BUILDING and ZONING DEPARTMENT Permit Expires 19 - Bay and Haviland Road, R.D. 1 Box 98 Zoning Designation li.b i4 0. = i1 !'tg • ' Queensbury, New York 12801 Variance N ' f� Site Plan Review No. LJlas l i-I- it 16 q - I (. '5 I Approve • Altil j ,?dre6-P14141.. APPLICATION FOR ��1 190.1 j ' 11"2)3)415i6 ® Ju�4. BUILDING AND ZONING PERMIT ----- * * * * .* * * * .*. * * * * * * * * * * * * * * * * * *• * * * * * *. * * * * :: * A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. ANSWER ALL OF THE FOLLOWING. The undersigned hereby applies for a Building Permit to do the following work which will be done in accordance with the description, plans and specifications submitted, and such special conditions as may be indicated on the Permit. The owner of this property is: C_C A SS(C I/ Q vile aui_bE(�5=N P.O. Address 6 l) Z E �1 -Be e, \-4 f 203 9 Tel. BTZ-O6,7 1/ • i Property Location: (c-I Cc�Ue.E'NS (,GIl��- S7 (V0. D5 , Tax Map g_41/12±14 Street number, or building lot number Subdivision name (if applicable) .AC-a N .) THE PERSON RESPONSIBLE FOR SUPERVISION OF WORK AS REGARDS BUILDING CODES IS : o1 ( A x 0E4 •3•T 7-1 . rq g 7 -O6z2 Name P.O. Address Tel. No. ;;gy�.pp - Name of builder C3S(C Lioeile igaAir dress 'Rd )e i f 2 A- Zi ST.1.. • � , �Z-C ? Name of plumber 3 I'7m` ,je25 Address {G/ iz.e" & .c f i 'Z i „ A;g ' Tel. 7C _4-/6C7 Name of mason ,gym MA`7��el p D Address s 3 frie fC 6 brad.e. Tel. �cl 3 -- 35,3 Z NATURE OF PROPOSED WORK: * ZONING INFORMATION: V. Construction of a new building * A PLOT' PLAN MUST BE PREPARED AND SUBMITTED,' _Addition to a building * drawn reasonably to scale and attached hereto, Alteration to a building * showing clearly and distinctly all buildings, (no change to exterior dimensions) * whether existing or proposed and indicate all Other work (describe) * set-back dimensions from property lines. Give * street and number or lot number and indicate - *FOR DEMOLITION PERMIT, STATE SIZE AND_ * whether interior or corner lot. Show location of water supply and location and configuration LOCATION OF STRUCTURES AFFECTED. 'V * of septic disposal area. * * COMPLETE INFORMATION REQUIRED BELOW. * Size of property 1 Z c- ft X 7_00 ft. * Existing building(s) Size, ft X ft. * mol(e PROPOSED BUILDING AND USE: ,II- ® 1 Existing building(s) Use Size of,new structure 'L`C ft X (55 ft * aj c i e. Foundation-pier/slab/crawl/partia /full * Proposed building, distance from property line (circle one) * Front yard 53 ft Rear yard f2 A ft No. of stories (habitable spa e) 2. 7 ft and �n ft Height (grade to ridge) ''' ft. * Side yards - . If on corner, setback from side street ft, * ! If residential, no. of families , No. of rooms(excluding baths) 8 . * OCCUPANCY INFORMATION No. of bedrooms s3 , * ' No. of bathrooms Z.i/t- .* PRIMARY BUILDING - Primary heating system EL-ectia C 61rh 0* " T One family dwelling Type of fuel * Two family dwelling No. of fireplaces to be installed ' * Multiple dwelling / Number of units • Will a wood stove be installed? .nf6 * Permanent occupancy * Transient occupancy Central Air conditioning? kJ O * Business BUILDING STYLE, PRIMARY STRUCTURE ' Industrial Ranch ' Contemporary Log cabin * Other Raised ranch Mansion Duplex * If addition, what will use be? Split level Old style Bungalow * Cape Cod Cottage Other * ACCESSORY 'BUILDING- ro is Row Town House * Detached garage/one car/ two .r/ car ( CIRCLE ONE PLEASE ) * Attached garage/one car/ o o c. / car * * * * * * * * * * * * * * * * * * Private storage building ESTIMATED MARKET VALUE OF *" Other CONSTRUCTION $ Iq'o * INFORMATION ON ,BUILDING SPECIFICATIONS, ON REVERSE SIDE OF THIS SHEET, TO BE COMPLETED! Form BPA 4/86 and-vl i I BUILDING PERMIT APPLICATION CONTINUED I BUILDING SPECIFICATIONS: Type of construction, wood frame, fire safe,etc. 'C,A.1CX ' Will any second-hand or ungraded lumber be used? If so, for what? (J Q Foundation wall materials e co Cd Thickness n' Depth of foundation below grade (to boo ooting) f Will there be a cellar? Yes Heated or unheated? 0/�( Floor sq. footage sq sq ft Will there be a basement? Will any portion be used ag living space? (If so, what portion? OA- sq.ft. - - Type of use? Type of roof - sl7•17e /flat/shed/other,5co/ed Material, of roof A - 4A(,( S' IAi9fe Size, wood studs — "X Fj " spacing 1g "o.c. length%Zs/cft. -. )0C.0 Joists(floor beams) 1st. floor Z "X Ib " spacing 14. "o.c. span ft. AS Per y'tein)S Joists (floor beams) 2nd. floor Z. "X /Q " spacing j , "o.c. span d ft. /1 Po© Woaks Overlays(ceili • beams) NA- "X " spacing "o.c. span ft. Roof rafters �' �"X 6spacing 16 o.c. span ft. PeA N Roof trusses(pre-engiyieered) spacing Z4 "o.c. span ft. AS .-f (Pt cduS p Exterior wall finis4CillpBoi}ef) -4- O a ' • A CU VA I'IQ uiM pigul Interior wall finish If a garage is to be attache , describe materials to be used for FIRE SEPARATION: 5' is c5,j �o C�, .fpSo Is therd to bean opening between garage and dwelling? V&S If so will a Fire-rated door, enclosure, and self-closing device be provided? '#e S Will a flue-lined chimney be installed? IV© Height above roof /O A- ft. Depth of chimney foundation below grade Oft. Depth of fireplace hearth Ii1W ft. in.. Water supply unicipa or private well SEPTIC SYSTEM istance from ANY private well(including adjoining properties f/14- ft. (A separate application is necessary for any repair or riew installation of septic system) Town of Queensbury A F F .I D A V I T STATE OF NEW YORK County of Warren I swear that to the best of my knowledge and belief the statements contained in this application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done 'on the described premises and that all provisions of the BUILDING CODE, THE ZONING ORDINANCE, and all other laws pertaining to the proposed work shall be complied with, whether specified or not, and that such work is authorized by the owner. C� n SWORN TO BEFORE ME THIS Signature ' / b r Owner, owner's agent,arcnitect,contractor G() day ofDECOON9e196Vh Notary Public, Warren County, N.Y. * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * SPECIAL CONDITIONS OF THE PERMIT: tl } By .Jru4Queu4tj .601 APPLICATION FOR SEPTIC.DISPOSAL PERMIT DATE I, 4 /86' LOCATION OF PROPERTY FOR INSTALLATION 5-1 ()Jeeps! S C.Ai _ Owner's Name: cCA-SS(C lie vie txJ(C,LS Telephone: i 72 Address: YDr)1 darl e4ST (&fok/e (J is j Installer's Name: 6-4- U I/- Telephone: 251 2_I cg Number of bedrooms (residential only) 3 Total daily flow (compute @ 150 gal per bedroom) 4 Sb Topography: circle one:(ilat)Rolling Steep Slope % of slope 2'67a Soil Nature: circle on . San Loam Clay Other / Depth: 7/0 feet Ground Water: At what depth? feet Bedrock or Impervious Material: At what depth? /Q feet- " Less +AWN Percolation test: circle one: :(-of require. required /rate tj min. inch. Domestic water supply: circle one: unicipal Well Other IF domestic water supply is a Well: Separation: Watersupply from Septic absorption Dvp/k- feet PROPOSED SYSTEM: Septic Tank /aid gal. (minimum size: 1,000 gal.) TILE FIELD: Each Trench feet / Total system length Z,<Oi feet SEEPAGE PIT(S): Number of N/A / Size each • feet by feet Size of stone to be used #3/J-fo/ Z / Depth or Thickness j j) Zdf'i feet * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * IMPORTANT ...Please...LIST NEW EQUIPMENT TO BE INSTALLED * * * * * * * * * * *.* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * (over) Section II Septic System Inspections: . A. All applications for septic system installation, alteration or repair, as - required bythe Town of q Queensbury Sanitary Sewage Ordinance, shall be submitted to the Building Department at least 24 hours before start of construction and shall include a plot plan showing: 1.) the proposed location of the system _ ._.'2.).location and distance to lot lines 3.) location and distance to structures 4.) location and distance to any water supply ; 5.) size and dimensions of all tanks, distribution. boxes, tile fields and/or drywells B: No system shall be covered before inspection and approval by the building Inspector. Failure to comply with this requirement may result in the uncovering of the system by the installer and a fine of up to $250.00. C. An approved copy of the plot plan shall be available on the construction site. Failure to produce said plot plan at time of inspection may result in an immediate work stoppage. D. Should unforeseen problems during construction prevent proper installation, alteration or repair of an approved system, a new proposal must be submitted to the Queensbury Building Department before further construction. • I have read the regulations above and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. Signature of responsible person: v R�'� 4l p/ Date: 1 Z e Town of Queensbury Building and Code Department Bay at Haviland Road Queensbury, New York 12801 (518) 792-5832 SETTLED 1.763 . . . HOME OF NATURAL BEAUTY . . . A GOOD,PLACE TO LIVE TOWN OF QUEENSBURY WARREN COUNTY , NEW YORK Application for : BUILDING PERMIT IN COMPLIANCE WITH THE NEW YORK STATE ENERGY CONSERVATION CODE A permit must be obtained before beginning work . ANSWER ALL of the following: . 1. Gross floor area (����`���(/-�Crj / [ 2 . Type of heat .�eC"�{L e[' ' 4s :— '1. C /41/42b 3 . Is the building mechanically cooled? 0 6 Il 4 . Percentage of area of windows and doors 1 P /6 A. Over 16% Only 1 . Uo value of gross area of walls , roof/ceiling and floors exposed to ambient conditions :O.(270 2 . Floor over heated spaces NO a. Are foundation walls insulated? YES NO 1. If YES , what is the R value? 3 . Slab on grade YES NO a. If YES , what is the • value of insulation' around perimeter of floor? 4 . Is basement heated? YES NO5 a. R value of insulation 5. Type of insulation B. Under 16% Only 1. R value of roof and floors exposed to ambient conditions P F6002. It-i I - 2 . R value of exterior walls . — l 1 3 . R value of glazed area d9Z- f c ?.. 4 . R value of doors 4--- I 0 ' 5 . R value of floors over unheated spaces e - / I 6 . R value of slab edge insulation - unheated slab 7 . R value of slab insulation - heated slab 1 A 8 . R value of heated basement/cellar• walls (above grade) N! 9 . R value of heated basement/cellar walls (below grade) A/ ' 10 . Type of insulation rj D• /C( S,5 C. Controls �O 1 . Thermostat maximum heat setting "l D. Duct Systems 1. Is duct system installed in unheated spaces? YES NO a. If YES , R value of duct ,installation C� b. R value of duct in other areas E . Piping Insulation 1. Size of hot water or cooling carry,jng agent pipe klik 2 . R value of pipe insulation F. Service Water Heating C f j`�1 . Performance efficiencyL, 2 . Temperature control setting maximum JZQ G. For Swimming Pool Only A ' 1 . Maximum heating ,rU Telephone No . ( / z—o 6 LB S Y (applicant ' s signature) BUILDING DEPT.COPY OF APPLICATION FORM 46-EL,NEW YORK BOARD OF FIRE UNDERWRITERS.. FILE THIS COPY WITH BUILDING DEPT:WHEN REQUIRED. : .._ . -- t - (TEMP.ik DATE'= _ ' CITY OR 1-- :, , i - r j 7 ;PI- lC ! %' l:'tiffy / 't COUNTY t l�I %r VILLAGE iV--t' / f/ / t:" r 1�"( / I 1J� t (.4 /j ( X'(' 1 � )i !t j i ,)tF �_ C I I TOWNSHIP ly.l �t f_ {' ✓ �� t 9 / 1f`�, �� '' l .1 STREET AND�O.OR �r ;^� rM1 ,-_ ) r JJJ ROAD AND POLE NO. 1�-- /� ) / J vl l f'j�G: :3 i 7 I:LC POLE NO. BETWEEN WHAT TWO ----- I t" - _ CROSS STREETS IS -(j' .-+� /,,,- }�' - y I .r: .:r' PREMISES LOCATED? 't t i --k ii'-'i ! ➢t I/.''`.l I 1% l"-' SECTION ! `` BLOCK / LOT ) 7`= OCCUPANT'S BUILDING NAME OCCUPANCY % `l - ' ! 1 / / - i OWNER'S NAME / / `�-, i � ---r / %= //- .i AND ADDRESS ,� / - ,0 c 4%•.i j — :,r7 / •--�-/ /`_/ .:C. TEL # `-�/ f! /- '`!Z r CURRENT .) -- - SUPPLIED i� / i i -- / /.;[ L '! BY 1/ ) �i�7(t FROM THEIR j,'//'(-f r (/i - OFFICE BUILDING ',_. WORK /t J DEFECTS IS NEW 1T�„I OLD❑ IS ! NEW Q/\ ADDITIONAL❑ REMOVED ❑ LIST BELOW ALL EQUIPMENT WHICH YOU INSTALLED, I No.of Fixtures& BRANCH' NUMBER OF OUTLETS Lamp Receptacles MOTORS .• HEATERS CIRCUITS - OFFICE USE - Loca- . -.-ONLY tion Side Attach't H.P. . Watts A.W.G. Ceiling Wall Recep'Is Switch Pendant Bracket No. Type Each ', No. Each No. Gauge INSPECTION Out- side - Sub- ; 1 base ,. :..� Base- ment 1st Fl. 2nd Fl. 3rd Fl. �_. j . :', H '` i ' REMARKS: LIST OTHER ELECTRICAL DEVICES NOT SET FORTH ABOVE=-,.-.- / ''- „,,}�:' ' DO,NOYUSE THIS SPACE. 1 ' -. r' I / iU This application is intended to cover the above-listed equipment to be inspected but if at time of inspection there is found additional equipment not above listed, you are authorized to make the inspection and adjust the fee to cover the additional equipment,as provided by the applicant- SIZE OF ELECTRIC SIGN TOTAL MAINS FEEDERS LAMPS WATTS CHARACTER EXPOSED GAS TUBE SIGN _ OF WORK CONCEALED TRANSFORMERS OF VA WORK TO BE (NUMBER) • (CAPACITY) STARTED COMPLETED SIZE OF SIGN . SERVICE OVERHEAD UNDERGROUND MAKER ENTERS BUILDING OF SIGN INSPECTION REQUESTED ON OR AS NEAR AS POSSIBLE NEW OLD AVOID DELAY BY GIVING FULL AND ACCURATE INFORMATION.ALL SPACES DATE OF MUST BE FILLED IN OR APPLICATION MAY BE RETURNED. APPLICATION • PRINT NAME AND ADDRESS I �: <<; _Jt 1 NAME OF f/ / -' �i'i.,,. y�(SIGNATURE y;f r, \i - '1,, i i . APPLICANT / J:-'. `: -'7' �k'•,frt (=� i`i/ r !ii . rV _. °‘OF APPLICANT J '-.-_,{. 1 �``r 7`� i ' %�(_- II STREET ADDRESS i�- % F•,�,t.r't 1 TELEPHONE# `f7-.' t.--1,I/-!:•;.r/ CITY OR j •t ,l I ,+ ZIP ,I -,i LICENSE NO. POSTOFFICE yam.''1 r k'.-4, Ii�"� �F CODE t -�'( '!'� WHEN APPLICABLE 46 EL (REV. 1i66) A SEPARATE APPLICATION MUST BE FILED FOR EACH SEPARATE BUILDING awn o/ Queeni‘ury BUI ING and ZONING DEPARTMENT ay an Haviland Road, R.D. 1 Box 98 �, u ensbury, New York 12801 BUIL INSPECTOR ' S REPORT • LOCATION �L5-7 u7y��2(�_ Date, -3/ /Z� Permit No. C1� r.:5' * * * * * * * * * * * * * * * * * * * * * * * ✓ = APPROVED - YES / NO Footing/Pier Forms Foundation Waterproofing Backfill Framing Roofing Siding X Masonry Ve ,eer Rough Plumbing Relief Valv- K Ext. Porches X Finished Floo,s V Interior Trim Stairs & Railino Cellar Drain T. Concrete Floo s Plbg. Fixtur-s • X Gar. Firepraofing )C Door Clos-• s Se • &ir-'e • / Smoke De -ctors Chimney INSULAT ON: Foundation Floor Walls Ceili g • FINAL LECTRICAL INSPECTION 1 DRIVEWAY APPROVAL Final Building Survey Next scheduled inspection (call when ready) Remarks- / 1-7 g4/7 i) c, 0.11, e //-/r ///2 X‘'(/ • 0/ Buildin Inspector 6/86 and-vl 1�I-���/1 . _Jotun 01 Queeni‘ury q' BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 .� Queensbury, New York 12801 SEPTIC�� DISPOSAL��SYYSTEM INSPECTION • E ( ci% //dam O LOCATION 4- / 9.[,e_l_1 Z_-' . DATE 9/icicF7 PERMIT NO. C,) , -1613 SOIL TYPE - Sand - Loam - Clay - Percolation Test Required? YES - NO Percolation rate - Min/Inch I TYPE of SYSTEM Absorption fie',d, total le-ga Length of each trench Depth of trenc s ,, Size of gravel_` / 1SEEPAGE PITS4N ...er of Size- ft. X f ,. Gravel size " PIPING: lIr Size ._- Type Bldg. to tank Tank to dist. box //I .- Dist. box to field pit '2;/� Openings sealed? YES V'NO ) Partial LOCATION/SEPARAT NS: Foundation to to ft. Foundation to ab orption ft. Absorption to 1 line ft. Separation of p s ft. LOCATION OF SYS ON PROPERTY(circle one) Front - /R r eft side - Right side COMMENTS,; I' qt.pg j � ,'r---3 „.1 I, 6-„/.., t ,) ,...,_,.....pr 41 / I,- r —44-----74 i SYSTEM USE APPROVED YES x NO r ,. /I� Building nspector 01/86 and vl C la . down of Queniurcy q/ 7�BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 4.1/•)/-1 SEPTIC DISPOSAL SYSTEM INSPECTION • NAME e//05,/G ,/7 LOCAT I ON„c674 ,Sf /eG%�0,/ _ DATE :/, 7 / PERMIT NO. iF 1L53 SOIL TYPE - an - Loam - Clay - Percolatio . est Required? YES N Percolation rate - Min/Inch 0 �(- TYPE of SYST;, : � Absorption f i-1d, tota'l length ;OD Length of eac trenc S O Depth of trenc'°-s Size of gravel '— SEEPAGE PITS{N . ` of) Size- ft. X ' ft. Gravel size - ; PIPING: Size Type Bldg. to tank / • • n ! d Tank to dist. oox ' « f� : Dist. box to Field/pit Openings seal.d? YES 4.0 Partial LOCATION/SEP•RATIONS: Foundation p`. tank 7, t. Foundation ro absorption � "'t. Absorption o lot line 9O f f' Separation pits ft. LOCATION SYSTEM ON PROPERTY(circle one) Front ear - Left side - Right side - COMMEN . '07,,-e.,c_ 0„4-6? .,,er--( 2.1...,e ./L-6-)� k-k.-0--e. 4) Z5c,„......4( SYSTEM USE APPROVED YES (6-9) (C,//k//? • Building Inspector 01/86 and vl ...awn of Queeniur1 BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 BUILDING INSPECTOR ' S REPORT NAME C L/ 16- i ))4450Li9c-1Z_s LOCATION 5,1 (PUG- %&✓,s L/ ,t/ Date , / c ygr., Permit No. 8(-- 8 0 ✓ = APPROVED - YES / NO Footing/Pier Forms _ Foundation Waterproofing . Backfill Framing Roofing Siding Masonry Veneer Rough Plumbing Relief Valves . Ext. Porches Finished Floors >' Interior Trim `, Stairs & Railings r, Cellar Drain Tile Concrete Floors Plbg. Fixtures Gar. Fireproofing Door Closers Smoke Detectors Chimney }INSULATION: Foundation Floors Walls Ceiling _ FINAL ELECTRICAL INSPECTION DRIVEWAY APPROVAL Final Building Survey Next scheduled inspection (call when ready) Remarr/k�sy- 7, Building Inspector 6/86 and-vl .own of Queen iturcy BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 BUILDING INSPECTOR ' S REPORT NAME /54 LOCATION Alf-I , Date �(� / ; � Permit No. ( --- * * * * * * * * * * * * * * * * * * * * .* * * ✓ = APPROVED - YES / NO Footing/Pier Forms Foundation Waterproofing Backfill Framing Roofing Siding Masonry Veneer N7/(N.,1/4s‘ Rough Plumbing Relief Valves Ext. Porches Finished Floors Interior Trim Stairs & Railings Cellar Drain Tile Concrete Floors Plbg. Fixtures Gar. Fireproofing Door Closers Smoke Detectors `,iChimney f/te-E_ /ti INSULATION: Foundation Floors Walls Ceiling FINAL ELECTRICAL INSPECTION DRIVEWAY APPROVAL Final Building Survey Next scheduled inspection (call when ready) Remarks- 6r Building Inspector 6/86 and-vl ...awn Of Queenilur/ �` y BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 BUILDING INSPECTOR' S REPORT NAME (k5 7 l LOCATIor\a 4L5 a (/ Date (p . / 7 ermit No: 36 ✓ = APPROVED - YES / NO Footing/Pier Forms Foundation Waterproofing Backfill Framing Roofing Siding Masonry Veneer /Rough Plumbing � 0 k Relief Valves Ext. Porches Finished Floors Interior Trim Stairs & Railings Cellar Drain Tile Concrete Floors Plbg. Fixtures Gar. Fireproofing Door Closers Smoke Detectors Chimney INSULATION: Foundation Floors Walls Ceiling FINAL ELECTRICAL INSPECTION DRIVEWAY APPROVAL Final Building Survey Next scheduled inspection (call when ready) Remarks- • Avelly1 Building Inspector 6/86 and-vl awn of Queenturj BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 BUILDING INSPECTOR 'S REPORT NAME (-.). la 5 S 01.4'I �s LOCATION LOT, 6---1 Date ,51, / 9 Permit No. t) o—c g * * * * * * * * * * * * * * * * * * * * .* * * ✓ = APPROVED - YES / NO Footing/Pier Forms Foundation Waterproofing Backfill `(Framing , -�1 i)�i11 ✓/ ! Roofing Siding Masonry Veneer Rough Plumbing Relief Valves Ext. Porches Finished Floors Interior Trim Stairs & Railings Cellar Drain Tile Concrete Floors Plbg. Fixtures Gar. Fireproofing Door Closers ' Smoke Detectors Chimney INSULATION: Foundation -- - Floors Walls Ceiling FINAL ELECTRICAL INSPECTION DRIVEWAY APPROVAL Final Building Survey Next scheduled inspection (call when ready) Remarks- 7 .1444r4r--- /V17113 Building Inspector 6/86 and-vl 5L277 /r7 Jown of Queen il ur, BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 BUILDING INSPECTOR ' S REPORT NAME Lv 7- Date__6/lay /Y 7 Permit No. * * * * * * * * * * * * * * * * * * * * * * * ✓ = APPROVED - YES / NO Footing/Pier Forms Foundation Waterproofing Backfill r , c Framing X Roofing // \\ Siding Masonry Veneer Rough Plumbing Relief Valves Ext. Porches Finished Floors Interior Trim Stairs & Railings \\& Cellar Drain Tile Concrete Floors Plbg. Fixtures Gar. Fireproofing Door Closers Smoke Detectors Chimney INSULATION: Foundation Floors Walls Ceiling FINAL ELECTRICAL INSPECTION DRIVEWAY APPROVAL Final Building Survey Next scheduled inspection (call when ready) Remarks- Building Inspector 6/86 and-vl cam. c��o �jy r �; 3Q✓'- ` _Down of Queens ur/ BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 BUILDING INSPECTOR REPORT 6t/t NAME Wr--)44z,g LOCATION / /)we , Date / 2-5/Permit No. g * * * * * * * * * * * * * * * * * * * * * * * c( 9 ✓! �1C�PVED - / NO otin /Pier Forms /)/ Foundation - Waterproofing Backfill Framing • Roofing Siding Masonry Veneer Rough Plumbing Relief Valves Ext. Porches Finished Floors Interior Trim Stairs & Railings Cellar Drain Tile Concrete Floors Plbg. Fixtures Gar. Fireproofing f \ Door Closers � • Smoke Detectors Chimney INSULATION: Foundation Floors Walls Ceiling FINAL ELECTRICAL INSPECTION DRIVEWAY APPROVAL Final Building Survey Next scheduled inspection (call when ready) Remarks-90 ✓V • y f Building Inspector 6/86 and-vl Jown of Queeniur, BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 BUILDING INSPECTOR ' S REPORT NAME C /q 5 5. /7 ern►ei 1C�1 e-I^S LOCATION t_G7 5- f �ra .e ens e Date /7 / Permit No. S.(o 5,3 * * * * * * * * * * * * * * * * * * * * * * * ✓ = APPROVED - YES / NO Footing/Pier Forms Foundation waterproofing )(Backfill Framing Roofing Siding Masonry Veneer Rough Plumbing Relief Valves Ext. Porches Finished Floors Interior Trim Stairs & Railings Cellar Drain Tile Concrete Floors yA Plbg. Fixtures r Gar. Fireproofing \ / Door Closers 5ie Smoke Detectors f ; Chimney / INSULATION: �f Foundation f • Floors Walls Ceiling FINAL ELECTRICAL INSPECTION DRIVEWAY APPROVAL Final Building Survey � r Next scheduled inspection (call when ready) Remarks-Az, /4-7,0 Building Inspector 6/86 and-vl (II ( 3l2-7 p� /fi n. Jown of Queeniur, BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 BUILDING INSPECTOR ' S444-e_14 REPORT NAME la 5 s 2 C decS LOCATION S 7 9I/7.5 Date J / 2,7/"Permit No. X - � 5 3 * * * * * * * * * * * * * * * * * * * * * * * f✓ = APPROVED - YE / NO >ooting/Pier Forms e R Foundation Waterproofing Backfill Framing Roofing Siding Masonry Veneer Rough Plumbing Relief Valves Ext. Porches Finished Floors Interior Trim Stairs & Railings Cellar Drain Tile Concrete Floors Plbg. Fixtures Gar. Fireproofing // Door Closers '\ Smoke Detectors Chimney j INSULATION: Foundation Floors Walls Ceiling FINAL ELECTRICAL INSPECTION DRIVEWAY APPROVAL Final Building Survey Next scheduled inspection (call when ready) Remarks- •� /%n��' w K5 Building Inspector 6/86 and-vl -c.-P-e__ c---e / (j Jocun of QueensLry / / BUILDING and ZONING DEPARTMENT et-4., Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 SEPTIC DISPOSAL SYSTEM INSPECTION NAME (( 5tc / i -R„ taeckc LOCATION I Or �1 Is e C (C (-(.� DATE /a/ 3 PERMIT NO. D' K5 J SOIL TYPE - Sand - Loam - Clay - / Percolation Test Required? YES - O Percolation rate - Min/Inch TYPE of SYSTEM: Absorption field total length ' Length of each t ench Depth of trenches • Size of gravel SEEPAGE PITS{Numbel of) Size- ft. X f . Gravel size PIPING: Siz �(/"" Bldg. to tank � Tank to dist. box Dist. box to fiel./pi. Openings sealed? YES NO Partial LOCATION/SEPARATIONS: Foundation to t•,nk ft. Foundation to .a.sorption ft. Absorption to of line ft. Separation o 1•its ft. LOCATION 0 _4STEM ON PROPERTY circle one) Front - Rear Left side - Righ side - COMME ' • i Th, 4 ( d , s--/ )7/. ,A,e' X- / SYSTEM USE APPROVE YES B ding Inspector 01/86 and vl .,..._.„....__, N Qum E-,i,5. 1 L,q ,v� • 5- g.3n t , •p • :-J- p U ' • 0 ifT I .. 0 �� sZ ".1t,t - li v=soc� ua\v o, . �� N Nr 1W I ' e lonsisrft;;!! +oz. _ • I J N v I N . L . __ , ______, .____ G1./ . / 7/, y6 , • P2, r F:74..4N GoT S/ - S 6--c.--r;oAl two • 1l4111/4/ (401rwE ‘5l'ArES 74.,.v o F Qvr EA's6-vz-si 4/4.ee :v c o u,vrV, ,v. V $CAGE'. / ' : s-o , QArC: 4/o(.., '3, /9 i- VAn, D(Ase7 . 4 5-rEVE5 . ctWO 5c1.e grroes, 4o&)J5-F.4ccs, A).Y• rJ.y. srtrE" C/4. 'c,E,. ' (-i7 CL(A3V_. {4014E U)Lbc. c