Concrete compression 06042021 CONCRETE COMPRESSIVE STRENGTH TEST REPORT "'`''µ' Alra-rracast emaP,aar Report Number: JB211030.0014 Service Date: 06/04/21 30 Corporate Cir Ste 201 Report Date: 06/14/21 Albany,NY 12203-5169 Task: 518-266-0310 Client Project The Great Escape Theme Park,L.P. The Great Escape Theme Park Attn:Rebecca Wood 1172 State Rte 9 1172 Route 9 Queensbury,NY 12804 Queensbury,NY 12804 Project Number:JB211030 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Sample Date: 06/04/21 Sample Time: 1220 Sampled By: A.Valvo Mix ID: 5000 CSP Weather Conditions: Sunny Supplier: Jointa Galusha,LLC - Accumulative Yards: 210 Batch Size(cy): 10 Batch Time: 1152 Plant: Glens Falls Placement Method: Pump Truck No.: 4907 Ticket No.: 2095 Water Added Before(gal): Field Test Data Water Added After(gal): Sample Location: End of Truck Chute Test Result Specification Placement Location: Foundation Mat for Outlaw Ride Slump(in): 6 Max 8 Air Content(%): 7.2 4.5-7.5 Concrete Temp.(F): 77 Ambient Temp.(F): 70 Plastic Unit Wt.(pct): Yield(Cu.Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Weight Date Test Load Strength Fracture Tested No. ID (n) (sq in) Received_ (lbs) Tested (days) (lbs) (psi) Type By 5 1 4.00 12.57 06/07/21 8.35 06/07/21 3 59,550 4,740 5 ADB 5 2 4.00 12.57 06/07/21 8.35 06/09/21 5 72,040 5,730 2 ADB 5 3 3.99 12.5 06/07/21 8.40 06/11/21 7 74,880 5,990 2 ADB 5 4 06/07/21 8.35 07/02/21 28 5 5 06/07/21 8.35 07/02/21 28 5 6 06/07/21 8.35 07/02/21 28 5 7 06/07/21 8.40 Hold Initial Cure: Onsite Cooler Final Cure: Moist Room Comments: Not tested for plastic unit weight. Note: Reported air content does not include Aggregate Correction Factor(ACF). 5000 PSI,Superplasticizer Samples Made By:Dente Group-A Terracon Co. Services: Sample fresh concrete at the placement locations,perform required field tests and cast compressive strength samples. Dente Group-A Terracon Co.Rep.: A.Valvo Reported To: Dean of The Great Escape and Rich Barber/Rozell Contractor: Rozell / Report Distribution: / (1)The Great Escape Theme Perk,L.P.,Rehecca (1)The Great Escape Thecae Park,L.P.,Laraine Reviewed By: wood Caricad Jared f,-aff Staff Geologist Test Methods: ASTM C 31,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only'applicable to the actual samples tested at the location(s)referenced and are not necessarily Indicative of the properties of other apparently similar or identical materials. CR000t,11-16-12,Rev.6 Page 5 of 5 CONCRETE COMPRESSIVE STRENGTH TEST REPORT `f- Mmnan Comm" Report Number: J131211030.0014 Service Date: 06/04/21 30 Corporate Cir Ste 201 Report Date: 06/14/21 Albany,NY 12203-5169 Task: 518-266-0310 Client Project The Great Escape Theme Park,L.P, The Great Escape Theme Park Attn:Rebecca Wood It 72 State Rte 9 1172 Route 9 Queensbury,NY 12804 Queensbury,NY 12804 Project Number:JB211030 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Sample Date: 06/04/21 Sample Time: 1140 Sampled By: A.Valvo Mix ID: 5000 CSP Weather Conditions: Partly Sunny Supplier: Jointa Galusha,LLC Accumulative Yards: 160 Batch Size(cy): 10 Batch Time: 1101 Plant: Glens Falls Placement Method: Pump Truck No.: 4525 Ticket No.: 2091 Water Added Before(gal): Field Test Data Water Added After(gal): Sample Location: End of Truck Chute Test Result Specification Placement Location: Foundation Mat for Outlaw Ride Slump(in): 5 Max 8 Air Content(%): 6.0 4.5-7.5 Concrete Temp.(F): 77 Ambient Temp.(F): 70 Plastic Unit Wt.(Pei): Yield(Cu.Yds.): Laboratory Test Data age at Maximum Compressive Set Specimen Avg Diam. Area Date Weight Date Test Load Strength Fracture Tested No. ID (in) _ (sq in) Received. (ibs) Tested (days) (lbs) (psi) Type By 4 1 4.00 12.57 06/07/21 8.50 06/07/21 3 62,390 4,960 3 ADB 4 2 4.00 12.57 06/07/21 8.50 06/09/21 5 67,680 5,390 2 ADB 4 3 3.99 12.5 06/07/21 8.55 06/11/21 7 66,450 5,310 2 ADB 4 4 06/07/21 8.55 07/02/21 28 4 5 06/07/21 8.55 07/02/21 28 4 6 06/07/21 8.50 07/02/21 28 4 7 06/07/21 8.50 Hold Initial Cure: Onsite Cooler Final Cure: Moist Room Comments: Not tested for plastic unit weight. Note: Reported air content does not include Aggregate Correction Factor(ACF). 5000 PSI,Superplasticizer Samples Made By:Dente Group-A Terracon Co. . Services: Sample fresh concrete at the placement locations,perform required field tests and cast compressive strength samples. Dente Group-A Terracon Co.Rep.: A.Valvo Reported To: Dean of The Great Escape and Rich Barber/Rozell Contractor: Rozell Report Distribution: (1)The Great Escape Theme Park,L.P.,Rebecca (1)The Great Escape Theme Park,L.P.,Lorraine Wood Caricari Test Methods: ASTM C 31,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. caooai,i i-1612,Rev.6 Page 4 of 5 CONCRETE COMPRESSIVE STRENGTH TEST REPORT L` a7Lrra=cox�w,nr Report Number: JB211030.0014 1 � Service Date: 06/04/21 30 Corporate Cir Ste 201 Report Date: 06/14/21 Albany,NY 12203-5169 Task: 518-266-0310 Client Project The Great Escape Theme Park,L.P. The Great Escape Theme Park Attn:Rebecca Wood 1172 State Rte 9 1172 Route 9 Queensbury,NY 12804 Queensbury,NY 12804 Project Number:JB211030 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Sample Date: 06/04/21 Sample Time: 1030 Sampled By: A.Valvo Mix ID: 5000 CSP Weather Conditions: Partly Cloudy Supplier: Jointa Galusha,LLC Accumulative Yards: 110 Batch Size(cy): 10 Batch Time: 0954 Plant: Glens Falls Placement Method: Pump Truck No.: 4912 Ticket No.: 2086 Water Added Before(gal): Field Test Data Water Added After(gal): Sample Location: End of Truck Chute Test Result Specification Placement Location: Foundation Mat for Outlaw Ride Slump(m): 6 Max 8 Air Content(%): 6.5 4.5-7.5 Concrete Temp.(F): 75 Ambient Temp.(F): 70 Plastic Unit Wt.(pcf): Yield(Cu.Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Weight Date Test Load Strength Fracture Tested No. ID (in) (sq in) Received (lbs) Tested (days) (1bs) (psi) Type By 3 1 4.00 12.57 06/07/21 8.40 06/07/21 3 61,710 4,910 2 ADB 3 2 4.00 12.57 06/07/21 8.50 06/09/21 5 66,380 5,280 2 ADB 3 3 3.99 12.5 06/07/21 8.50 06/11/21 7 73,200 5,850 2 ADB 3 4 06/07/21 8.55 07/02/21 28 3 5 06/07/21 8.50 07/02/21 28 3 6 06/07/21 8.55 07/02/21 28 3 7 06/07/21 8.45 Hold Initial Cure: Onsite Cooler Final Cure: Moist Room Comments: Not tested for plastic unit weight. Note: Reported air content does not include Aggregate Correction Factor(ACF). 5000 PSI,Superplasticizer Samples Made By:Dente Group-A Terracon Co. Services: Sample fresh concrete at the placement locations,perform required field tests and cast compressive strength samples. Dente Group-A Terracon Co.Rep.: A.Valvo Reported To: Dean of The Great Escape and Rich Barber/Rozell Contractor: Rozell Report Distribution: (1)The Great Escape Theme Park,L.P.,Rebecca (1)The Great Escape Theme Park,L.P.,Lorraine Wood Caricari Teat Methods: ASTM C 31,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report Is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company..Test results transmitted herein are only applicable to the j actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or Identical materials. Page 3 of 5 CR0001,11-16-12,Rev.6 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Wal •7C��tra�tcoxMx,r Report Number: JB211030.0014 Service Date: 06/04/21 30 Corporate Cir Ste 201 Report Date: 06/14/21 Albany,NY 12203-5169 Task: 518-266-0310 Client Project The Great Escape Theme Park,L.P. The Great Escape Theme Park Attn:Rebecca Wood 1172 State Rte 9 1172 Route 9 Queensbury,NY 12804 Queensbury,NY 12804 Project Number:JB211030 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Sample Date: 06/04/21 Sample Time: 0855 Sampled By: A.Valvo Mix ID: 5000 CSP Weather Conditions: Overcast Supplier: Jointa Galusha,LLC Accumulative Yards: 60 Batch Size(cy): 10 Batch Time: 0825 Plant: Glens Falls Placement Method: Pump Truck No.: 4903 Ticket No.: 2078 Water Added Before(gal): Field Test Data Water Added After(gal): Sample Location: End of Truck Chute Test Result Specification Placement Location: Foundation Mat for Outlaw Ride Slump(in): 5 1/2 Max 8 Air Content(®/o): 7.0 4.5-7.5 Concrete Temp.(F): 76 Ambient Temp.(F): 66 Plastic Unit Wt.(pet): Yield(Cu.Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Weight Date Test Load Strength Fracture Tested No. ID (in) (sq in) Received (Ibs) Tested (days) (Ibs) (psi) Type By 2 1 4.00 12.57 06/07/21 8.50 06/07/21 3 62,240 4,950 2 ADB 2 2 4.00 12.57 06/07/21 8.60 06/09/21 5 63,800 5,080 2 ADB 2 3 3.99 12.5 06/07/21 8.60 06/11/21 7 68,820 5,500 2 ADB 2 4 06/07/21 8.55 07/02/21 28 2 5 06/07/21 8.65 07/02/21 28 2 6 06/07/21 8.60 07/02/21 28 2 7 06/07/21 8.60 Bold Initial Cure: Onsite Cooler Final Cure: Moist Room Comments: Not tested for plastic unit weight. Note: Reported air content does not include Aggregate Correction Factor(ACF). 5000 PSI,Superplasticizer Samples Made By:Dente Group-A Terracon Co. Services: Sample fresh concrete at the placement locations,perform required field tests and cast compressive strength samples. Dente Group-A Terracon Co.Rep.: A.Valvo Reported To: Dean of The Great Escape and Rich Barber/Rozell Contractor: Rozell Report Distribution: (1)The Great Escape Theme Park,L.P.,Rebecca (1)The Great Escape Theme Park,L.P.,Lorraine Wood Carlcad Test Methods: ASTM C 31,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or Identical materials. ceta001,11-16-12,Rw.6 Page 2 of 5 CONCRETE COMPRESSIVE STRENGTH TEST REPORT 7r�rarart�PaW Report Number: JB211030.0014 1!6"a 4 Service Date: 06/04/21 30 Corporate Cir Ste 201 Report Date: 06/14/21 Albany,NY 12203-5169 Task: 518-266-0310 Client Project The Great Escape Theme Park,L.P. The Great Escape Theme Park Attn:Rebecca Wood 1172 State Rte 9- 1172 Route 9 Queensbury,NY 12804 Queensbury,NY 12804 Project Number:JB211030 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Sample Date: 06/04/21 Sample Time: 0722 Sampled By: A.Valvo Mix ID: 5000 CSP Weather Conditions: Overcast Supplier: Jointa Galusha,LLC Accumulative Yards: 10 Batch Size(cy): 10 Batch Time: 0639 Plant: Glens Falls Placement Method: Pump Truck No.: 4598 Ticket No.: 2073 Water Added Before(gal): Field Test Data Water Added After(gal): Sample Location: End of Truck Chute Test Result Specification Placement Location: Foundation Mat for Outlaw Rid Slump(in): 6 Max 8 Air Content(%): 6.0 4.5-7.5 Concrete Temp.(F): 75 Ambient Temp.(F): 64 Plastic Unit WL(pcf): Yield(Cu.Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Weight Date Test Load Strength Fracture Tested No. ID (in) (sq in) Received (lbs) Tested (days) (ibs) (pso Type By 1 1 .4.00 12.57 06/07/21 8.65 06/07/21 3 67,070 5,340 3 ADB 1 2 4.00 12.57 06/07/21 8.65 06/09/21 5 72,400 5,760 2 ADB 1 3 3.99 12.5 06/07/21 8.70 06/11/21 7 71,840 5,750 2 ADB 1 4 06/07/21 8.55 07/02/21 .28 1 5 06/07/21 8.60 07/02/21 28 1 6 06/07/21 8.70 07/02/21 28 1 7 -06/01/21 8.70 Hold Initial Cure: Onsite Cooler . Final Cure: Moist Room Comments: Not tested for plastic unit weight. Note: Reported air content does not include Aggregate Correction Factor(ACF). 5000 PSI,Superplasticizer Samples Made By:Dente Group-A Terracon Co. Services: Sample fresh concrete at the placement locations,perform required field tests and cast compressive strength samples. Dente Group-A Terracon Co.Rep.: A.Valvo Reported To: Dean of The Great Escape and Rich Barber/Rozell Contractor: Rozell Report Distribution: (1)The Great Escape Theme Park,L.P.,Rebecca (1)The Great Escape Theme Park,L.P.,Loraine Wood Caricari Test Methods: ASTM C 3.1,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is,exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001,11-WIZ Rev.6 Page 1 of 5 CONCRETE COMPRESSIVE STRENGTH TEST REPORT HUP Report Number: JB211030.0014 Service Date: 06/04/21 30 Corporate Cir Ste 201 Report Date: 06/14/21 Albany,NY 12203-5169 Task: 518-266-0310 Client Project The Great Escape Theme Park,L.P. The Great Escape Theme Park Attn:Rebecca Wood 1172 State Rte 9 1172 Route 9 Queensbury,NY 12804 Queensbury,NY 12804 Project Number:JB211030 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Sample Date: 06/04/21 Sample Time: 0722 Sampled By: A.Valvo Mix ID: 5000 CSP Weather Conditions: Overcast Supplier: Jointa Galusha,LLC Accumulative Yards: 10 Batch Size(cy): 10 Batch Time: 0639 Plant: Glens Falls Placement Method: Pump Truck No.: 4598 Ticket No.: 2073 Water Added Before(gal): Field Test Data Water Added After(gal): Sample Location: End of Truck Chute Test Result Specification Placement Location: Foundation Mat for Outlaw Rid Slump(in): 6 Max 8 Air Content(%): 6.0 4.5-7.5 Concrete Temp.(F): 75 Ambient Temp.(F): 64 Plastic Unit Wt.(pcf): Yield(Cu.Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Weight Date Test Load Strength Fracture Tested No. ID (in) (sq in) Received Ohs) Tested (days) Ohs) (psi) Type By 1 1 4.00 12.57 06/07/21 8.65 06/07/21 3 67,070 5,340 3 ADB 1 2 4.00 12.57 06/07/21 8.65 06/09/21 5 72,400 5,760 2 ADB 1 3 3.99 12.5 06/07/21 8.70 06/11/21 7 71,840 5,750 2 ADB 1 4 06/07/21 8.55 07/02/21 28 1 5 06/07/21 8.60 07/02/21 28 1 6 06/07/21 8.70 07/02/21 28 1 7 06/07/21 8.70 Hold Initial Cure: Onsite Cooler Final Cure: Moist Room Comments: Not tested for plastic unit weight. Note: Reported air content does not include Aggregate Correction Factor(ACF). 5000 PSI,Superplasticizer Samples Made By:Dente Group-A Terracon Co. Services: Sample fresh concrete at the placement locations,perform required field tests and cast compressive strength samples. Dente Group-A Terracon Co.Rep.: A.Valvo Reported To: Dean of The Great Escape and Rich Barber/Rozell Contractor: Rozell Report Distribution: (1)The Great Escape Theme Park,L.P.,Rebecca (1)The Great Escape Theme Park,L.P.,Lorraine Wood Caricari Test Methods: ASTM C 31,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOo1,11-16-12,Rev.6 Page 1 of 5 CONCRETE COMPRESSIVE STRENGTH TEST REPORT 101 lknmconCOMPAW Report Number: J13211030.0014 Service Date: 06/04/21 30 Corporate Cir Ste 201 Report Date: 06/14/21 Albany,NY 12203-5169 Task: 518-266-0310 Client Project The Great Escape Theme Park,L.P. The Great Escape Theme Park Attn:Rebecca Wood 1172 State Rte 9 1172 Route 9 Queensbury,NY 12804 Queensbury,NY 12804 Project Number:JB211030 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Sample Date: 06/04/21 Sample Time: 0855 Sampled By: A.Valvo Mix ID: 5000 CSP Weather Conditions: Overcast Supplier: Jointa Galusha,LLC Accumulative Yards: 60 Batch Size(cy): 10 Batch Time: 0825 Plant: Glens Falls Placement Method: Pump Truck No.: 4903 Ticket No.: 2078 Water Added Before(gal): Field Test Data Water Added After(gal): Sample Location: End of Truck Chute Test Result Specification Placement Location: Foundation Mat for Outlaw Ride Slump(in): 5 1/2 Max 8 Air Content(%): 7.0 4.5-7.5 Concrete Temp.(F): 76 Ambient Temp.(F): 66 Plastic Unit Wt.(pet): Yield(Cu.Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Weight Date Test Load Strength Fracture Tested No. ID (in) (sq in) Received (lbs) Tested (days) (ibs) (psi) Type By 2 1 4.00 12.57 06/07/21 8.50 06/07/21 3 62,240 4,950 2 ADB 2 2 4.00 12.57 06/07/21 8.60 06/09/21 5 63,800 5,080 2 ADB 2 3 3.99 12.5 06/07/21 8.60 06/11/21 7 68,820 5,500 2 ADB 2 4 06/07/21 8.55 07/02/21 28 2 5 06/07/21 8.65 07/02/21 28 2 6 06/07/21 8.60 07/02/21 28 2 7 06/07/21 8.60 Hold Initial Cure: Onsite Cooler Final Cure: Moist Room Comments: Not tested for plastic unit weight. Note: Reported air content does not include Aggregate Correction Factor(ACF). 5000 PSI,Superplasticizer Samples Made By:Dente Group-A Terracon Co. Services: Sample fresh concrete at the placement locations,perform required field tests and cast compressive strength samples. Dente Group-A Terracon Co.Rep.: A.Valvo Reported To: Dean of The Great Escape and Rich Barber/Rozell Contractor: Rozell Report Distribution: (1)The Great Escape Theme Park,L.P.,Rebecca (1)The Great Escape Theme Park,L.P.,Lorraine Wood Caricari Test Methods: ASTM C 31,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001,11-16-12,xev.6 Page 2 of 5 CONCRETE COMPRESSIVE STRENGTH TEST REPORT „Mlracmce Report Number: J13211030.0014 Service Date: 06/04/21 30 Corporate Cir Ste 201 Report Date: 06/14/21 Albany,NY 12203-5169 Task: 518-266-0310 Client Project The Great Escape Theme Park,L.P. The Great Escape Theme Park Attn:Rebecca Wood 1172 State Rte 9 1172 Route 9 Queensbury,NY 12804 Queensbury,NY 12804 Project Number:JB211030 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Sample Date: 06/04/21 Sample Time: 1030 Sampled By: A.Valvo Mix ID: 5000 CSP Weather Conditions: Partly Cloudy Supplier: Jointa Galusha,LLC Accumulative Yards: 110 Batch Size(cy): 10 Batch Time: 0954 Plant: Glens Falls Placement Method: Pump Thick No.: 4912 Ticket No.: 2086 Water Added Before(gal): Field Test Data Water Added After(gal): Sample Location: End of Track Chute Test Result Specification Placement Location: Foundation Mat for Outlaw Ride Slump(in): 6 Max 8 Air Content(%): 6.5 4.5-7.5 Concrete Temp.(F): 75 Ambient Temp.(F): 70 Plastic Unit Wt.(pet): Yield(Cu.Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Weight Date Test Load Strength Fracture Tested No. 1D (in) (sq in) Received (lbs) Tested (days) (lbs) (psi) Type By 3 1 4.00 12.57 06/07/21 8.40 06/07/21 3 61,710 4,910 2 ADB 3 2 4.00 12.57 06/07/21 8.50 06/09/21 5 66,380 5,280 2 ADB 3 3 3.99 12.5 06/07/21 8.50 06/11/21. 7 73,200 5,850 2 ADB 3 4 06/07/21 8.55 07/02/21 28 3 5 06/07/21 8.50 07/02/21 28 3 6 06/07/21 8.55 07/02/21 28 3 7 06/07/21 8.45 Hold Initial Cure: Onsite Cooler Final Cure: Moist Room Comments: Not tested for plastic unit weight. Note: Reported air content does not include Aggregate Correction Factor(ACF). 5000 PSI,Superplasticizer Samples Made By:Dente Group-A Terracon Co. Services: Sample fresh concrete at the placement locations,perform required field tests and cast compressive strength samples. Dente Group-A Terracon Co.Rep.: A.Valvo Reported To: Dean of The Great Escape and Rich Barber/Rozell Contractor: Rozell Report Distribution: (1)The Great Escape Theme Park,L.P.,Rebecca (1)The Great Escape Theme Park,LP.,Lorraine Wood Caricari Test Methods: ASTM C 31,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001,11-16-12,Rev.6 Page 3 of 5 CONCRETE COMPRESSIVE STRENGTH TEST REPORT WIRMIa A1CeiratOrl COMPANY Report Nudiber: JB211030.0014 Service Date: 06/04/21 30 Corporate Cir Ste 201 Report Date: 06/14/21 Albany,NY 12203-5169 Task: 518-266-0310 Client Project The Great Escape Theme Park,L.P. The Great Escape Theme Park Attn:Rebecca Wood 1172 State Rte 9 1172 Route 9 Queensbury,NY 12804 Queensbury,NY 12804 Project Number:JB211030 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Sample Date: 06/04/21 Sample Time: 1140 Sampled By: A.Valvo Mix ID: 5000 CSP Weather Conditions: Partly Sunny Supplier: Jointa Galusha,LLC Accumulative Yards: 160 Batch Size(cy): 10 Batch Time: 1101 Plant: Glens Falls Placement Method: Pump Truck No.: 4525 Ticket No.: 2091 Water Added Before(gal): Field Test Data Water Added After(gal): Sample Location: End of Truck Chute Test Result Specification Placement Location: Foundation Mat for Outlaw Ride Slump (in): 5 Max 8 Air Content(%): 6.0 4.5-7.5 Concrete Temp.(F): 77 Ambient Temp.(F): 70 Plastic Unit Wt.(pcf): Yield(Cu.Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Weight Date Test Load Strength Fracture Tested No. ID (in) (sq in) Received (lbs) Tested (days) (lbs) (psi) Type By 4 1 4.00 12.57 06/07/21 8.50 06/07/21 3 62,390 4,960 3 ADB 4 2 4.00 12.57 06/07/21 8.50 06/09/21 5 67,680 5,390 2 ADB 4 3 3.99 12.5 06/07/21 8.55 06/11/21 7 66,450 5,310 2 ADB 4 4 06/07/21 8.55 07/02/21 28 4 5 06/07/21 8.55 07/02/21 28 4 6 06/07/21 8.50 07/02/21 28 4 7 06/07/21 8.50 Hold Initial Cure: Onsite Cooler Final Cure: Moist Room Comments: Not tested for plastic unit weight. Note: Reported air content does not include Aggregate Correction Factor(ACF). 5000 PSI,Superplasticizer Samples Made By:Dente Group-A Terracon Co. Services: Sample fresh concrete at the placement locations,perform required field tests and cast compressive strength samples. Dente Group-A Terracon Co.Rep.: A.Valvo Reported To: Dean of The Great Escape and Rich Barber/Rozell Contractor: Rozell Report Distribution: (1)The Great Escape Theme Park,L.P.,Rebecca (1)The Great Escape Theme Park,L.P.,Lorraine Wood Caricari Test Methods: ASTM C 31,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. C110001,11-16-12,Rev.6 Page 4 of 5 CONCRETE COMPRESSIVE STRENGTH TEST REPORT esillII A1Ceffc7CQr1 Co0.7PANY Report Nuimber: J13211030.0014 Service Date: 06/04/21 30 Corporate Cir Ste 201 Report Date: 06/14/21 Albany,NY 12203-5169 Task: 518-266-0310 Client Project The Great Escape Theme Park,L.P. The Great Escape Theme Park Attn:Rebecca Wood 1172 State Rte 9 1172 Route 9 Queensbury,NY 12804 Queensbury,NY 12804 Project Number:JB211030 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Sample Date: 06/04/21 Sample Time: 1220 Sampled By: A.Valvo Mix ID: 5000 CSP Weather Conditions: Sunny Supplier: Jointa Galusha,LLC Accumulative Yards: 210 Batch Size(cy): 10 Batch Time: 1152 Plant: Glens Falls Placement Method: Pump Truck No.: 4907 Ticket No.: 2095 Water Added Before(gal): Field Test Data Water Added After(gal): Sample Location: End of Truck Chute Test Result Specification Placement Location: Foundation Mat for Outlaw Ride Slump(in): 6 Max 8 Air Content(%): 7.2 4.5-7.5 Concrete Temp.(F): 77 Ambient Temp.(F): 70 Plastic Unit Wt.(pcf): Yield(Cu.Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Weight Date Test Load Strength Fracture Tested No. ID (in) (sq in) Received Ohs) Tested (days) (lbs) (psi) Type By 5 1 4.00 12.57 06/07/21 8.35 06/07/21 3 59,550 4,740 5 ADB 5 2 4.00 12.57 06/07/21 8.35 06/09/21 5 72,040 5,730 2 ADB 5 3 3.99 12.5 06/07/21 8.40 06/11/21 7 74,880 5,990 2 ADB 5 4 06/07/21 8.35 07/02/21 28 5 5 06/07/21 8.35 07/02/21 28 5 6 06/07/21 8.35 07/02/21 28 5 7 06/07/21 8.40 Hold Initial Cure: Onsite Cooler Final Cure: Moist Room Comments: Not tested for plastic unit weight. Note: Reported air content does not include Aggregate Correction Factor(ACF). 5000 PSI,Superplasticizer Samples Made By:Dente Group-A Terracon Co. Services: Sample fresh concrete at the placement locations,perform required field tests and cast compressive strength samples. Dente Group-A Terracon Co.Rep.: A.Valvo Reported To: Dean of The Great Escape and Rich Barber/Rozell Contractor: Rozell Report Distribution: Reviewed By (1)The Great Escape Theme Park,L.P.,Rebecca (1)The Great Escape Theme Park,L.P.,Lorraine Wood Caricari Jared Staff Geo ogist Test Methods: ASTM C 31,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CRoo01,11-16-12,Rev.6 Page 5 of 5