Loading...
Construction Technology CONSTRUCTION TECHNOLOGY 4 William Street,Ballston Lake,New York 12019 Phone:(518)399-1848 Fax:(518)399-1913 CLIENT: JAG INDUSTRIES,INC. REPORT NUMBER: 1 :PAGE#:1 175 BROAD STREET,SUITE 320 INSPECTION DATE: 02/13/20 GLENS FALLS,NEW YORK 12801 OUR FILE NUMBER: 813.032 INSPECTOR&TEST SET: DAVE CASAW #5 ATT'N: MR.TIMOTHY BARBER AMBIENT WEATHER: 30's:LT.RAIN PROJECT: #8 BLUE LUPINE ROAD:WILTON,NEW YORK OUR FILE LOCATION: 198229 CONCRETE FIELD INSPECTION & COMPRESSION TEST RESULTS PLACEMENT LOCATION OF LOAD# 1 : FOOTING:A/5-C.5/6 PLACEMENT LOCATION OF LOAD# 2: FOOTING:C.5/6-E/6-EIS DELIVERED LOAD NUMBER: 1 2 TRUCK NUMBER/TICKET NUMBER: 45681 3197082 4523 / 3197083 YARDAGE DELIVERED/SUBTOTAL: 7.00/ 7.00 6.00 / 13.00 TIME CONC. BATCHED/ARRIVED: 12.521 1.25 1.04 / 1.38 TIME PLACEMENT BEGAN/ENDED: 1.30/ 1.50 1.52 / 2.10 CONCRETE AGE(HOURS) (SPEC: MAX: 1.50) 0.97 1.10 SLUMP ON ARRIVAL (INCHES): 4.50 4.25 WATER ADDED ONSITE(GALLONS): WATER ADDED AT DISCRETION OF: SLUMP OF CONCRETE INTO PUMP: IF APPLICABLE: PLACEMENT SLUMP(INCH) (SPEC: - 5.00) 4.50 4.25 ENTRAINED AIR (%VOL) (SPEC: 4.00- 7.00) 5.80 UNIT WEIGHT (PCF) (SPEC: - ) 148.44 CONCRETE TEMP. (F) (SPEC: 45 - 90) 60 60 NUMBER OF TEST SPECIMEN CAST: 6 LAB CYLINDER CONTROL NUMBERS 198229- 198234 DISCREPANCIES&REMARKS: PLACEMENT AREA REINFORCEMENT: CLEANLINESS&COVER ACCEPTABLE.PROPERLY SIZED&LOCATED. UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 CONCRETE SUPPLIER: PALLETTE STONE CORP. CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM:C39 DESIGN STRENGTH&FORMULA: 4000 P.S.I.@ 28 DAYS UNLESS OTHERWISE NOTED ALL CYLINDERS RECEIVED: 02/14/20 CEMENT: LBS. CYLINDER TEST TEST AGE ULTIMATE UNIT CEMENT: LBS. NUMBER DATE DAYS APPLIED LOAD P.S.I. WATER: GAL COARSE AGGREGATE#1: LBS. 198229 OPJ20/20 7 59,050 4700 COARSE AGGREGATE#2: LBS. 198230 02/20/20 7 56,550 4500 COARSE AGGREGATE#3: LBS. 198231 03/12/20 28 76,500 6090 FINE AGGREGATE: LBS. 198232 03/12/20 28 74,150 5900 ADMIXTURE#1: OZS. 198233 03/12/20 28 76,500 6090 ADMIXTURE#2: OZS. 198234 SPARE ADMIXTURE#3: OZS. AIR ENTRAINING AGENT: OZS. REPORT DISTRIBUTION: 1:FILE 5: 2:SUPPLIER 6: 3: 7: 4: 8: RESPECTFULLY SUBMITTED, CONSTRUCTION TECHNOLOGY ROBERT BEHAN (NICET) MANAGER TECHNICAL SVCS. CONSTRUCTION TECHNOLOGY 4 William Street,Ballston Lake,New York 12019 Phone:(518)399-1848 Fax:(518)399-1913 CLIENT. JAG INDUSTRIES,INC. REPORT NUMBER: 2 :PAGE#:1 175 BROAD STREET,SUITE 320 INSPECTION DATE: 02/18/20 GLENS FALLS,NEW YORK 12801 OUR FILE NUMBER: 813.032 INSPECTOR&TEST SET: DAVE CASAW #5 ATT'N: MR.TIMOTHY BARBER AMBIENT WEATHER: 20's:SNOW PROJECT: #8 BLUE LUPINE ROAD:WILTON,NEW YORK OUR FILE LOCATION: 198331 CONCRETE FIELD INSPECTION & COMPRESSION TEST RESULTS PLACEMENT LOCATION OF LOAD# 1 : FOUNDATION WALL:WEST WALL DELIVERED LOAD NUMBER: 1 TRUCK NUMBER/TICKET NUMBER: 4524/ 3197166 YARDAGE DELIVERED/SUBTOTAL: 8.00/ 8.00 TIME CONC. BATCHED/ARRIVED: 10.081 10.49 TIME PLACEMENT BEGAN/ENDED: 10.53/ 11.22 CONCRETE AGE(HOURS) (SPEC: MAX: 1.50) 1.23 SLUMP ON ARRIVAL (INCHES): 4.25 WATER ADDED ONSITE(GALLONS): WATER ADDED AT DISCRETION OF: SLUMP OF CONCRETE INTO PUMP: IF APPLICABLE: PLACEMENT SLUMP(INCH) (SPEC: - 5.00) 4.25 ENTRAINED AIR (%VOL) (SPEC: 4.00- 7.00) 5.10 UNIT WEIGHT (PCF) (SPEC: - ) 147.76 CONCRETE TEMP. (F) (SPEC: 45 - 90) 67 NUMBER OF TEST SPECIMEN CAST: 6 LAB CYLINDER CONTROL NUMBERS 198331- 198336 DISCREPANCIES&REMARKS: PLACEMENT AREA REINFORCEMENT: CLEANLINESS&COVER ACCEPTABLE.PROPERLY SIZED&LOCATED. UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 CONCRETE SUPPLIER: PALLETTE STONE CORP. CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM:C39 DESIGN STRENGTH&FORMULA: 4000 P.S.I.@ 28 DAYS UNLESS OTHERiMSE NOTED ALL CYLINDERS RECEIVED: 02/19/20 CEMENT: LBS. CYLINDER TEST TEST AGE ULTIMATE UNIT CEMENT: LBS. NUMBER DATE DAYS APPLIED LOAD P.S.I. WATER: GAL. COARSE AGGREGATE#1: LBS. 198331 02/25/20 7 54,350 4330 COARSE AGGREGATE#2: LBS. 198332 02/25/20 7 50,800 4040 COARSE AGGREGATE#3: LBS. 198333 03/17/20 28 68,400 5460 FINE AGGREGATE: LBS. 198334 03/17/20 28 66,250 5270 ADMIXTURE#1: OZS. 198335 03/17/20 28 69,100 5500 ADMIXTURE#2: OZS. 198336 SPARE ADMIXTURE#3: OZS. AIR ENTRAINING AGENT: OZS. REPORT DISTRIBUTION: 1:FILE 5: 2:SUPPLIER 6: 3: 7: 4: 8: RESPECTFULLY SUBMITTED, CONSTRUCTION TECHNOLOGY ROBERT BEHAN (NICET) MANAGER TECHNICAL SVCS. CONSTRUCTION TECHNOLOGY 4 William Street,Ballston Lake,New York 12019 Phone:(518)399-1848 Fax:(518)399-1913 CLIENT: JAG INDUSTRIES,INC. REPORT NUMBER: 5 :PAGE#:1 175 BROAD STREET,SURE 320 INSPECTION DATE: 02/28/20 GLENS FALLS,NEW YORK 12801 OUR FILE NUMBER: 813.032 INSPECTOR&TEST SET: DAVE CASAW #5 ATTN: MR.TIMOTHY BARBER AMBIENT WEATHER: 20's:CLOUDY PROJECT: #8 BLUE LUPINE ROAD:WILTON,NEW YORK OUR FILE LOCATION: 198493 CONCRETE FIELD INSPECTION & COMPRESSION TEST RESULTS PLACEMENT LOCATION OF LOAD# 1 : FOOTING:A/5-A/2.5 PLACEMENT LOCATION OF LOAD# 2: FOOTING:A/2.5-B/1 PLACEMENT LOCATION OF LOAD# 3: FOOTING:B/1-D/1 DELIVERED LOAD NUMBER: 1 2 3 TRUCK NUMBER/TICKET NUMBER: 4912/ 3197320 4902 / 3197321 4581 / 3197322 YARDAGE DELIVERED/SUBTOTAL: 8.00/ 8.00 7.00 / 15.00 7.00 / 22.00 TIME CONC. BATCHED/ARRIVED: 12.27/ 12.55 12.50 / 1.19 1.10 / 1.37 TIME PLACEMENT BEGAN/ENDED: 1.00/ 1.27 1.30 / 1.43 1.45 / 1.58 CONCRETE AGE(HOURS) (SPEC: MAX: 1.50) 1.00 0.88 0.80 SLUMP ON ARRIVAL (INCHES): 4.50 5.00 4.50 WATER ADDED ONSITE(GALLONS): WATER ADDED AT DISCRETION OF: SLUMP OF CONCRETE INTO PUMP: IFAPPLICABLE: PLACEMENT SLUMP(INCH) (SPEC: - 5.00) 4.50 5.00 4.50 ENTRAINED AIR (%VOL) (SPEC: 4.00- 7.00) 6.20 UNIT WEIGHT (PCF) (SPEC: - ) 146.81 CONCRETE TEMP. (F) (SPEC: 45 - 90) 70 70 70 NUMBER OF TEST SPECIMEN CAST: 6 LAB CYLINDER CONTROL NUMBERS 198493- 198498 DISCREPANCIES&REMARKS: PLACEMENT AREA REINFORCEMENT: CLEANLINESS&COVER ACCEPTABLE.PROPERLY SIZED&LOCATED. UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 CONCRETE SUPPLIER: PALLETTE STONE CORP. CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM:039 DESIGN STRENGTH&FORMULA: 4000 P.S.I.@ 28 DAYS UNLESS OTHERWISE NOTED ALL CYLINDERS REC13VED: 03/02/20 CEMENT: LBS. CYLINDER TEST TEST AGE ULTIMATE UNIT CEMENT: LBS. NUMBER DATE DAYS APPLIED LOAD P.S.I. WATER: GAL COARSE AGGREGATE#1: LBS. 198493 03/06/20 7 51,750 4120 COARSE AGGREGATE#2: LBS. 198494 03/06/20 7 49,300 3930 COARSE AGGREGATE#3: LBS. 198495 03/27/20 28 72,700 5790 FINE AGGREGATE: LBS. 198496 03/27/20 28 70,650 5630 ADMIXTURE#1: OZS. 198497 03/27/20 28 70,700 6630 ADMIXTURE#2: OZS. 198498 SPARE ADMIXTURE#3: OZS. AIR ENTRAINING AGENT: OZS. REPORT DISTRIBUTION: 1:FILE 5: 2:SUPPLIER 6: 3: 7: 4: 8: RESPECTFULLY SUBMITTED, CONSTRUCTION TECHNOLOGY 191991e .Emr ROBERT BEHAN (NICET) MANAGER TECHNICAL SVCS. CONSTRUCTION TECHNOLOGY 4 William Street,Ballston Lake,New York 12019 Phone:(518)399-1848 Fax:(518)399-1913 CLIENT: JAG INDUSTRIES,INC. REPORT NUMBER: 6 :PAGE#:1 175 BROAD STREET,SUITE 320 INSPECTION DATE: 03104/20 GLENS FALLS,NEW YORK 12801 OUR FILE NUMBER: 813.032 INSPECTOR&TEST SET: DAVE CASAW #5 ATT'N: MR.TIMOTHY BARBER AMBIENT WEATHER: 40's:CLOUDY PROJECT: #8 BLUE LUPINE ROAD:WILTON,NEW YORK OUR FILE LOCATION: 198547 CONCRETE FIELD INSPECTION & COMPRESSION TEST RESULTS PLACEMENT LOCATION OF LOAD# 1 : FOUNDATION WALL:D/1-Al2 PLACEMENT LOCATION OF LOAD# 2: FOUNDATION WALL:Al2-A/5 DELIVERED LOAD NUMBER: 1 2 TRUCK NUMBER/TICKET NUMBER: 4564/ 3197372 4911 / 3197373 YARDAGE DELIVERED/SUBTOTAL: 10.50/ 10.50 10.50 / 21.00 TIME CONC. BATCHED/ARRIVED: 8.29/ 9.00 8.48 / 9.15 TIME PLACEMENT BEGAN/ENDED: 9.05/ 9.34 9.35 / 9.53 CONCRETE AGE(HOURS) (SPEC: MAX: 1.50) 1.08 1.08 SLUMP ON ARRIVAL (INCHES): 5.00 4.25 WATER ADDED ONSITE(GALLONS): WATER ADDED AT DISCRETION OF: SLUMP OF CONCRETE INTO PUMP: IF APPLICABLE: PLACEMENT SLUMP(INCH) (SPEC: - 5.00) 5.00 4.25 ENTRAINED AIR (%VOL) (SPEC: 4.00- 7.00) 5.90 UNIT WEIGHT (PCF) (SPEC: - ) 150.56 CONCRETE TEMP. (F) (SPEC: 45 - 90) 74 74 NUMBER OF TEST SPECIMEN CAST: 6 LAB CYLINDER CONTROL NUMBERS 198547 - 198552 DISCREPANCIES&REMARKS: PLACEMENT AREA REINFORCEMENT: CLEANLINESS&COVER ACCEPTABLE.PROPERLY SIZED&LOCATED. UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 CONCRETE SUPPLIER: PALLETTE STONE CORP. CONCRETE TEST CYLNDER COMPRESSIVE RESULTS PER: ASTM:C39 DESIGN STRENGTH&FORMULA: 4000 P.S.I.@ 28 DAYS UNLESS OTHERIMSE NOTED ALL CYLINDERS RECEIVED: 03/05/20 CEMENT: LBS. CYLINDER TEST TEST AGE ULTIMATE UNIT CEMENT: LBS. NUMBER DATE DAYS APPLIED LOAD P.S.I. WATER: GAL COARSE AGGREGATE#1: LBS. 198547, 03/11/20 7 59,600 4750 COARSE AGGREGATE#2: LBS. 198548 03/11/20 7 56,450 4490 COARSE AGGREGATE#3: LBS. 198549 04/01/20 28 75,000 5970 FINE AGGREGATE: LBS. 198550 04/01/20 28 72,950 5810 ADMXTURE#1: OZS. 198551 04/01/20 28 71,650 5700 ADMIXTURE#2: OZS. 198552 SPARE ADMIXTURE#$: OZS. AIR ENTRAINING AGENT: OZS. REPORT DISTRIBUTION: 1:FILE 5: 2:SUPPLIER 6: 3: 7: 4: 8: RESPECTFULLY SUBMITTED, CONSTRUCTION TECHNOLOGY /z'4* . '4' ROBERT BEHAN (NICET) MANAGER TECHNICAL SVCS.