IM Inspection Worksheet_06-12-2023_15-21-26INSPECTION WORKSHEET (PTI-029235-2023) PT-0766-2023Case Number:Case Module:Permit Management 12/06/2023 FailedInspection Status:Inspection Date: Property Transfer InspectionsInspection Type:Inspector:Charles Dyer Job Address:Parcel Number:12 Chelsie Ln Lake George, NY 12845 279.13-1-18 Company Name NameContact Type Agent Patrick Burke Primary Owner David Prehoda Checklist Item CommentsPassed Building Inspector Notes True inspection was for 2 dwellings on one parcel. The barn dwelling is in need of new D box, field lines appeared to be in good shape. The lakeside dwelling is a failure, due to 4" line with a 90 just lying on top of tank as inlet line, tank was observed to be in good shape. A engineer will have to be hired to redesign system, the septic tank for this system will have to be equipped with "mafia blocks" due to being in a flood zone. 12/6/23 Weather/lack of information/inaccessibility False Capacity in gallons True 1000 gallon System/components indicate unacceptable True at lakeside dwelling Roof gutters don't discharge over leach field False Concrete tank True Temperature (Fahrenheit)True 32+ D-box material: concrete or plastic False Baffle & D-box or 45° angle False Apparent structural damage False Effluent filter False Septic inlet cover ext - Req 12"+ below grade False Visible scum layer False Septic tank (include # of tanks)True 2 Number of tank compartments False Plumbing fixtures tested & confirmed True Evidence of a pipe bypassing tank False System appears undersized/undersized components False Foundation drain(s)False Speed levers in D-box False Tank cover False yes on barn dwelling / no on lakeside dwelling System appears to have functioned adequately False System passes all function testing False Outlet pipe (automatic failure, if yes)False Metal tank (automatic failure)False Surface discharge? (if yes, to where?)False Roof runoff False Septic outlet cover ext - Req 12"+ below grade False System needs repairs True December 06, 2023 Page 1 of 2 INSPECTION WORKSHEET (PTI-029235-2023) Checklist Item CommentsPassed Sand filter False Absorption bed False Outflow line invert above leach line invert(s)?False Overflow pipe (automatic failure)False Depth below grade to top of tank True 6"- 8" Evidence of prolonged high liquid level False Access riser? (if yes, depth to cover)False Cesspool (automatic failure, if yes)False Inlet baffle True Recommend upgrade/expand/replace 1+ components True No treatment tank/other critical component(s)False Number of drop box(es)False As-built provided is accurate False Mound system False Test each fixture flow to septic tank True Liquid level AT/ABOVE/BELOW (one) discharge invert False Is tank pumped more than 4x/year?False On-site as-built req'd before insp is complete False Solids in D-box False Outlet baffle True Weather True cloudy Main tank cleanout size and location False Evidence of liquid above outlet inverts?False Other False Cracked, corroded or deformed?True need of replacement at barn dwelling Sump pump(s)False Plastic tank False Raised system False Pump station extention - Reg 12"+ below grade False Cracked, corroded or deformed?False Leaking water fixtures False Other False Absorption field True at barn dwelling Water tight tank True Seepage Pits: Number False Other False December 06, 2023 Page 2 of 2