Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
CC-0143-2023
• Office Use Only ) ADDITION/ALTERATION PERMIT permit#:CC-0143-2023 Town ofQuee 6 ry APPLICATION Permit Fee:$ 1295.00 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.queensbury.net Invoice#: .7215? Flood Zone? Y N Reviewed By:/ • Project Location: 40 Media Dr - Core Renovations Tax Map ID#: Subdivision Name: PROJECT INFORMATION: • • • TYPE: ElResidential © Commercial, Proposed.Use: Mixed Commerical Space ❑ Single-Family ❑ Two-Family ❑ Multi-Family (#of units_) ❑ Townhouse ® Business Office ❑ Retail ❑ Industrial/Warehouse ❑ Garage (#of cars ❑ Other(describe ) • • ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 3,700 sf 2nd floor: 2nd floor: 3rd floor: 3rd floor: Basement(habitable space): Basement (habitable space): Total sq ft: . Total sq ft: 3,700 sf Scope of work to be done: Architectural Modification to update corridor, lobby, and future tenant space including.misc demo, ceilings, floors, lighting, etc. I11 ` k , fF�.__. 11 1 APR 0 ,,nn, 61 • Toimq op f'>i .t�c'_ipjlJ7\ • Addition/Alteration Application Revised June 2022 • • • ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 15,000 2. Source of Heat (circle one): ❑ Gas ❑ Oil ❑ Propane ❑ Solar ❑ Other: . Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? ❑ YES •i NO Explain: 4. Are there any easements on,the property? ❑ YES © NO SITE INFORMATION: • Is this a corner lot? ❑ YES ® NO . • Will the grade be changed as a result of the construction? ❑ YES ® NO • What is the water source? .1 PUBLIC ❑ PRIVATE WELL • What type of wastewater system is on the parcel? 8 SEWER ❑ PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. • 2. If;for any reason,the building permit application is-withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100% of the fee is retained. 3. If thework 'is not completed by the 1 year expiration date the permit may. be renewed, subject to fees and department approval. 4. I certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. [also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above:. PRINT NAME: Cory Crane '1 Digitallyslgnar by Cory Crane SIGNATURE: COI,/ Crane ,i LCN Cory Cran`�negbblinc.wm.D=aaLDons�ctionsenlces,= DATE: 4I4/2023 Dale:2023.04.04 09:54:30-04'00' Addition/Alteration Application . Revised June 2022 e %F CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): BBL Construction Services (Cory Crane) Mailing Address, C/S/Z: 302 Washington Ave Ext,Albany NY 12203 Cell Phone: ( 518 )416-2224 Land Line: ( 518 )452-8200 Email:ccrane@bblinc.com • ' Primary Owner(s): Name(s): BBL Tribune,LLC(Brandon Stabler) Mailing Address, C/S/Z: 302 Washington Ave Ext,Albany NY 12203 Cell Phone: ( 518 )944-0695 Land Line: ( 518 )862-9133 Email:bstabler@columbiadev.com ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): BBL Construction Services(Cory Crane) ' Contractor Trade: General Contractor Mailing Address, C/S/Z: 302 Washington Ave Ext,Albany NY 12203 Cell Phone: ( 518 )416-2224 Land Line: ( 518 )452-8200 Email:ccrane@bblinc.com • • **Workers' Comp documentation must be submitted with this application** • • Architect(s)/Engineer(s): Business Name: hcp architects Contact Name(s): Joe Riley Mailing Address, C/S/Z: 302 Washington Ave Ext,Albany NY 12203 Cell Phone: ( 518 )694-1819 Land Line: ( 518 )218-0614 Email:jriley@hcpdesign.com • Contact Person for Compliance in regards to this project: Cory Crane Cell Phone: ( 518 )416-2224 Land Line: ( 518 )452-8200 Email:ccrane@bblinc.com • Addition/Alteration Application Revised June 2022 COMcheck Software Version 4.1.5.5 Envelope Compliance Certificate Project Information . Energy Code: 2018 IECC `^IED FOR E Project Title: Traveler's InsuranceT�V Location: Glens Falls, New York REviEp�.IANC Climate Zone: 6a o�� COp .��O,V 1 Project Type: Alteration ENE Construction Site: Owner/Agent: Designer/Contractor: 40 Media Drive M/E Engineering P.C. 1st Floor 433 State Street Queensbury, NY 12804 4th Floor Schenectady, NY 12305 518-533-2171 Building Area Floor Area 1-Office:•Nonresidential 15700 Envelope Assemblies • Envelope TBD: No envelope assemblies specified OF Ej',v1, ce. 1414/ W/,.4)4 • I Z • V >>887'1 o A . �. ' REssiooP`' F�� • • Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 1 of 13 Insurance.cck ` T AtliCOMcheck Software Version 4.1.5.5 Interior Lighting Compliance Certificate Project Information . Energy Code: 2018 IECC Project Title: Traveler's Insurance Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 40 Media Drive M/E Engineering P.C. 1st Floor 433 State Street Queensbury, NY 12804 4th Floor Schenectady, NY 12305 518-533-2171 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Office Total Allowed Watts= N/A Area Category Exemption Qualifications #Fixtures Total#Watts Activity Area• Pre-Alt. Repl./Added Pre-Alt. Post-Alt. Office(15700 sq.ft.) 35000.000 35000.000 Exemption:Replacement of bulbs and ballasts only. Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Office(15700 sa.ft.): Exempt Linear Fluorescent 1:Other:Electronic: 2 200 50 10000 Total Proposed Watts= N/A Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the • building plans,specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date Project Title: Traveler's Insurance Report date: 03/30/23 Data filename:. \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 2 of 13 Insurance.cck iCOMcheck Software Version 4.1.5.5 i Mechanical Compliance Certificate Project Information Energy Code: 2018 IECC • Project Title: Traveler's Insurance Location: Glens Falls, New York - Climate Zone: 6a Project Type: Alteration • Construction Site: Owner/Agent: Designer/Contractor: 40 Media Drive M/E Engineering P.C. 1st Floor 433 State Street Queensbury, NY 12804 • 4th Floor Schenectady, NY 12305 518-533-2171 • • • Mechanical Systems List Quantity System Type&Description 2 HVAC System 1 (Single Zone): Cooling:1 each-Split System,Capacity=36 kBtu/h,Air-Cooled Condenser,No Economizer,Economizer exception:None Proposed Efficiency=18.80 SEER,Required Efficiency: 13.00 SEER Fan System: AC-4,5 j First Floor VDC--Compliance(Motor nameplate HP method):Passes Fans: FAN 2 Supply,Constant Volume,920 CFM,0.1 motor nameplate hp,0.0 fan efficiency grade Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. , Name-Title Signature Date • • Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 3 of 13 Insurance.cck • COMcheck Software Version 4.1.5.5 irift Inspection Checklist Energy Code: 2018 IECC • Requirements: 96.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans,specifications,and/or . ❑Complies Requirement will be met. [P[12]1 calculations provide all information ❑Does Not with which compliance can be determined for the mechanical ❑Not Observable systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Load • calculations per acceptable engineering standards and handbooks. C103.2 . Plans,specifications, and/or ❑Complies Requirement will be met. [PR4]1 calculations provide all information ❑Does Not with which compliance can be [Not Observable Location on plans/spec: E.20 • determined for the interior lighting and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. • Additional Comments/Assumptions:• • • • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 4 of 13 Insurance.cck • Section # Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID C403.12.2{Snow/ice melting system and freeze ❑Complies Exception: Requirement does not apply. !protection systems have sensors and ❑Does Not C403.12.3;controls configured to limit service for ['Not Observable [FO9]3 ;pavement temperature and outdoor !temperature.future connection to ❑Not Applicable controls. Additional Comments/Assumptions: • • • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018Traveler's Page 5 of 13 Insurance.cck • Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.5, !Heated water supply piping conforms ElComplies Exception: Requirement does not apply. C404.5.1, Ito pipe length and volume ❑Does Not C404.5.2 ;requirements. Refer to section details. ❑Not Observable [PL6]3 ❑Not Applicable C404.6.3 ;Pumps that circulate water between a ❑Complies Exception: Requirement does not apply. [PL7]3 ;heater and storage tank have controls ❑Does Not ;that limit operation from startup to :Not Observable <= 5 minutes after end of heating • cycle. ❑Not Applicable C404.7 ;Demand recirculation water systems EComplies Exception: Requirement does not apply. [PL8]3 ;have controls that start the pump ❑Does Not ;u pon receiving a signal from the ❑Not Observable action of a user of a fixture or appliance and limits the temperature ENot Applicable l of the water entering the cold-water ;piping to 104°F. Additional Comments/Assumptions: • • • • • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 6 of 13 Insurance.cck Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions &Req.ID C402.2.6 ;Thermally ineffective panel surfaces of❑Complies Exception: Requirement does not apply. [ME41]3 ;sensible heating panels have ❑Does Not ;insulation >= R-3.5. ['Not Observable [Not Applicable C403.11.3)'HVAC piping insulation insulated in ❑Complies Requirement will be met. [ME61]z ;accordance with Table C403.11.3. ❑Does Not ;Insulation exposed to weather is Location on plans/spec: MO.2, MO.3 (protected from damage and is ❑Not Observable !provided with shielding from solar ❑Not Applicable • radiation. C403.8.4 ;Motors for fans that are not less than ❑Complies Requirement will be met. [ME142]z I1/12 hp and less than 1 hp are ❑Does Not ;electronically commutated motors or have a minimum motor efficiency of ❑Not Observable )70 percent.These motors have the ❑Not Applicable ;means to adjust motor speed. C403.8.5 ;Each DX cooling system > 65 kBtu ❑Complies Exception: Requirement does not apply. [ME143]z ;and chiller water/evaporative cooling ❑Does Not ;system with fans> 1/4 hp are Location on plans/spec: Existing systems>65kBtu are to :designed to vary the indoor fan airflow ❑Not Observable remain in place. as a function of load and comply with ❑Not Applicable ;detailed requirements of this section. • • C403.12.11Systems that heat outside the building ❑Complies Exception: Requirement does.not apply. [ME71]z ;envelope are radiant heat systems ❑Does Not ;controlled by an occupancy sensing device or timer switch. ❑Not Observable LiNot Applicable C403.2.3 ;HVAC equipment efficiency verified. ❑Complies • See the Mechanical Systems list for values. [ME55]2 I ❑Does Not [Not Observable ❑Not Applicable C403.2.2 Natural or mechanical ventilation is ❑Complies Requirement will be met. [ME59]i provided in accordance with ❑Does Not International Mechanical Code Chapter 4. Mechanical ventilation has ['Not Observable capability to reduce outdoor air supply ❑Not Applicable • to minimum per IMC Chapter 4. C403.7.1 ;Demand control ventilation provided ❑Complies Exception: Requirement does not apply. [ME59]1 ;for spaces>500 ft2 and >25 ❑Does Not • people/1000 ft2 occupant density and ;served by systems with air side ❑Not Observable ;economizer, auto modulating outside ❑Not Applicable air damper control, or design airflow >3,000 cfm. C403.7.2 :Enclosed parking garage ventilation ❑Complies Exception: Requirement does not apply. [ME115]3 ;has automatic contaminant detection LiDoes Not ;and capacity to stage or modulate :fans to 50%or less of design capacity. ENotObservable ❑Not Applicable C403.7.6 I HVAC systems serving guestrooms in ❑Complies Exception: Requirement does not apply. [ME141]3 ;Group R-1 buildings with > 50 ❑Does Not ;guestrooms: Each guestroom is provided with controls that ❑Not Observable automatically manage temperature ❑Not Applicable !setpoint and ventilation(see sections ;C403.7.6.1 and C403.7.6.2). C403.7.4 Exhaust air energy recovery on ❑Complies Exception: Requirement does not apply. [ME57]1 systems meeting Table C403.7.4(1) ❑Does.Not • and C403.7.4(2). ['Not Observable ❑Not Applicable • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 7 of 13 Insurance.cck Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.7.5 1 Kitchen exhaust systems comply with ElComplies Exception: Requirement does not apply. [ME116]3 !replacement air and conditioned ❑Does Not 'supply air limitations,and satisfy hood I rating requirements and maximum ['Not Observable lexhaust rate criteria. ❑Not Applicable C403.11.1 HVAC ducts and plenums insulated in EComplies Exception: Requirement does not apply. accordance with C403.11.1.and ❑Does Not • C403.11.2 constructed in accordance with [ME60]z 1C403.11.2,verification may need to ['Not Observable occur during Foundation Inspection. ENot Applicable C403.4.1. ;Heating for vestibules and air curtains EComplies Exception: Requirement does not apply. 4 Iwith integral heating include ❑Does Not [ME63]2 automatic controls that shut off the heating system when outdoor air ['Not Observable temperatures> 45F.Vestibule ENot Applicable ;heating and cooling systems controlled by a thermostat in the ,vestibule with heating setpoint<= 160F and cooling setpoint>= 80F. C403.3.3 ;Hot gas bypass limited to: <=240 ❑Complies Requirement will be met. [ME35]1 'kBtu/h-50%>240 kBtu/h-25% ElDoes Not :Not Observable Location on plans/spec: MO.6-No hot gas bypass specified. System is capable of continuous capacity modulation. ENot Applicable • C408.2.2. ;Air outlets and zone terminal devices EComplies• Requirement will be met. 1 ;have means for air balancing. EDoes Not [ME53]3 [Not Observable ENot Applicable C403.5, ;Refrigerated display cases,walk-in EComplies Exception: Requirement does not apply. C403.5.1, !coolers or walk-in freezers served by ❑Does Not C403.5.2 ;remote compressors and remote [ME123]3 icondensers not located in a :Not Observable !condensing unit, have fan-powered ENot Applicable • ;condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Additional Comments/Assumptions: • • • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 8 of 13 Insurance.cck • Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.2. Spaces required to have light- ❑Complies Exception: Daylight spaces that comply with this code. 2 reduction controls have a manual Does Not [EL22]1 control that allows the occupant to Location on plans/spec: E2.0 reduce the connected lighting load in ['Not Observable a reasonably uniform illumination ❑Not Applicable pattern >= 50 percent. C405.2.1, Occupancy sensors installed in ❑Complies Exception:Automatic-on controls are allowed in corridors, C405.2.1. classrooms/lecture/training rooms, ❑Does Not stairways, restrooms, primary building entrance areas and 1 conference/meeting/multipurpose lobbies,and areas where manual-on controls could impact [EL18]1 rooms,copy/print rooms, Not Observable safety or security. lounges/breakrooms,enclosed offices, ❑Not Applicable open plan office areas, restrooms, Location on plans/spec: E2.0 storage rooms, locker rooms, warehouse storage areas, and other spaces<= 300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. C405.2.1. Occupancy sensors control function in ❑Complies Exception: Requirement does not apply. 2 warehouses: In warehouses,the ❑Does Not • [EL19]1 lighting in aisleways and open areas is ['Not Observable Location on plans/spec: E2.0 • controlled with occupant sensors that automatically reduce lighting power ❑Not Applicable by 50%or more when the areas are unoccupied.The occupant sensors control lighting in each aisleway independently and do not control lighting beyond the aisleway being controlled by the sensor. C405.2.1. Occupant sensor control function in ❑Complies Requirement will be met. 3 • open plan office areas: Occupant ❑Does Not [EL2O]1 sensor controls in open office spaces ['Not Observable Location on plans/spec: E2.0 . >= 300 sq.ft. have controls 1) configured so that general lighting can ENot Applicable • be controlled separately in control zones with floor areas <= 600 sq.ft. within the space, 2) automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space, 3) are configured so that general lighting power in each control zone is reduced by>=80%of the full zone general lighting power within 20 minutes of all occupants leaving that control zone, and 4)are configured such that any daylight responsive control will activate space general lighting or control zone general lighting only when occupancy for the same area is detected. C405.2.2, I Each area not served by occupancy ❑Complies Exception: Lighting controlled by occupancy sensors. C405.2.2. sensors (per C405.2.1) have time- Does Not 1, switch controls and functions detailed Location on plans/spec: E2.0 C405.2.2. :in sections C405.2.2.1 and C405.2.2.2. Not Observable 2 DNot Applicable [EL21]2 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\DesInfo\COMCHECK\233018 Traveler's Page 9 of 13 Insurance.cck • • • Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.3, ;Daylight zones provided with ❑Complies Requirement will be met. C405.2.3. individual controls that control the ❑Does Not 1, lights independent of general area ['Not Observable Location on plans/spec: E2.0 • C405.2.3. !lighting. See code section C405.2.3 2 !Daylight-responsive controls for ❑Not Applicable [EL23]2 ;applicable spaces,C405.2.3.1 Daylight `responsive control function and !section C405.2.3.2 Sidelit zone. C405.2.4 Separate lighting control devices for ❑Complies Requirement will be met. [EL26]1 specific uses installed per approved ❑Does Not lighting plans. Location on plans/spec: E2.0 :Not Observable ['Not Applicable C405.2.4 Additional interior lighting power ❑Complies Requirement will be met. [EL27]1 allowed for special functions per the ❑Does Not approved lighting plans and is [Not Observable Location on plans/spec: E2.0 automatically controlled and separated from general lighting. ❑Not Applicable C405.3 Exit signs do not exceed 5 watts per ['Complies Requirement will be met. [EL6]1 face. ❑Does Not :Not Observable Location on plans/spec: E7.0 ❑Not Applicable , C405.6 ;Low-voltage dry-type distribution ❑Complies Requirement will be-met. [EL26]2 electric transformers meet the ❑Does Not minimum efficiency requirements of Table C405.6. ❑Not Observable ❑Not Applicable • C405.7 ;Electric motors meet the minimum ❑Complies . Requirement will be met. [EL2712 'efficiency requirements of Tables ❑Does Not C405.7(1)through C405.7(4). Efficiency verified through certification ['Not Observable I under an approved certification ❑Not Applicable !program or the equipment efficiency • I ratings shall be provided by motor . • manufacturer(where certification {programs do not exist). C405.8.2, ;Escalators and moving walks comply ❑Complies C405.8.2. !with ASME A17.1/CSA B44 and have ❑Does Not 1 !automatic controls configured to [EL28]2 ;reduce speed to the minimum ❑Not Observable !permitted speed in accordance with ❑Not Applicable • !ASME A17.1/CSA B44 or applicable • local code when not conveying passengers. C405.9 !Total voltage drop across the EComplies Requirement will be met. [EL29]2 combination of feeders and branch ❑Does Not ;circuits<= 5%. :Not Observable ❑Not Applicable Additional Comments/Assumptions: • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\DesInfo\COMCHECK\233018 Traveler's Page 10 of 13 Insurance.cck • • • • Section # Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, Furnished O&M instructions for ❑Complies Requirement will be met. C408.2.5. systems and equipment to the ❑Does Not 2 building owner or designated [FI17]3 representative. ['Not Observable ENot Applicable C303.3, Furnished O&M manuals for HVAC ❑Complies Requirement will be met. C408.2.5. (systems within 90 days of system ❑Does Not 3 ;acceptance. [F18]3 ; • ENot Observable ENot Applicable C403.2.2 HVAC systems and equipment ❑Complies Exception: Multiple units of the same type of equipment with [FI27]3 :capacity does not exceed calculated ❑Does Not sequencing controls. loads. ['Not Observable ENot Applicable C403.2.4. I Heating and cooling to each zone is ❑Complies Requirement will be met. 1 icontrolled by a thermostat control. EDoes Not [FI47]3 !Minimum one humidity control device ['Not Observable Location on plans/spec: M2.0 • per installed humidification/dehumidification ENot Applicable I system. C403.4.1. 1Thermostatic controls have a 5 °F ❑Complies Requirement will be met. 2 deadband. ❑Does Not [FI38]3 ENot Observable ENot Applicable C403.2.4.,;Temperature controls have setpoint ❑Complies Requirement will be met. 1.3 :overlap restrictions. EDoes Not [FI20]3 ['Not Observable ENot Applicable C403.2.4. I Each zone equipped with setback ❑Complies Requirement will be met. 2 controls using automatic time clock or EDoes Not • [FI39]3 programmable control system. N ENot Observable ENot Applicable C403.2.4. ;Automatic Controls: Setback to 55°F ❑Complies Exception: Requirement does not apply. 2.1, i(heat)and 85°F(cool); 7-day clock, 2- EDoes Not C403.2.4. 1 hour occupant override, 10-hour 2.2 ;backup :Not Observable [F140]3 ENot Applicable C403.2.4. ;Systems include optimum start ❑Complies Exception: Requirement does not apply. 2.3 controls. EDoes Not [FI41]3 ENot Observable ❑Not Applicable C405.4.1 Interior installed lamp and fixture EComplies See the Interior Lighting fixture schedule for values. [F118]1 lighting power is consistent with what EDoes Not is shown on the approved lighting :Not Observable plans, demonstrating proposed watts are less than or equal to allowed ❑Not Applicable watts. C408.1.1 Building operations and maintenance ❑Complies [F157]1 documents will be provided to the ❑Does Not owner. Documents will cover manufacturers'information, ENot Observable specifications, programming ENot Applicable procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and operated. • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 11 of 13 Insurance.cck • • Section # Final Inspection Complies? Comments/Assumptions & Req.ID C408.2.1 Commissioning plan developed by ❑Complies Requirement will be met. [F128]1 - registered design professional or ❑Does Not approved agency. ['Not Observable ENot Applicable C408.2.3. HVAC equipment has been tested to ❑Complies Requirement will be met. 1 ensure proper operation. DDoes Not [FI31]1 [(Not Observable ❑Not Applicable C408.2.3. ;HVAC control systems have been ❑Complies Requirement will be met. 2. (tested to ensure proper operation, ❑Does Not [FI10]1 ;calibration and adjustment of controls. ['Not Observable ENot Applicable C408.2.4 Preliminary commissioning report ❑Complies Requirement will be met. [FI29]1 completed and certified by registered ❑Does Not design professional or approved agency. ENot Observable ' ENot Applicable C408.2.5. !Furnished HVAC as-built drawings EComplies Requirement will be met. 1 submitted within 90 days of system ❑Does Not [FI7]3 acceptance. [Not Observable ENot Applicable C408.2.5. I Furnished as-built drawings for ❑Complies Requirement will be met. 1 electric power systems within 90 days ❑Does Not [FI16]3 ;of system acceptance. ENot Observable ENot Applicable C408.2.5. IAn air and/or hydronic system ❑Complies Requirement will be met. 3 :balancing report is provided for HVAC ❑Does Not [F143]1 systems. :Not Observable ❑Not Applicable C408.2.5. Final commissioning report due to ❑Complies Requirement will be met. 4 building owner within 90 days of ❑Does Not [F130]1 receipt of certificate of occupancy. :Not Observable ❑Not Applicable C408.3 Lighting systems have been tested to ❑Complies Requirement will be met. [F133]1 ensure proper calibration,adjustment, ❑Does Not programming, and operation. ENot Observable ENot Applicable Additional Comments/Assumptions: • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\DesInfo\COMCHECK\233018 Traveler's Page 12 of 13 Insurance.cck • Project Title: Traveler's Insurance • Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018_Traveler's Page 13 of 13 Insurance.cck 0 ,� FIRE MARSHAL'S OFFICE Town of Queensbury 742 Bay Road, Queensbury, NY 12804 "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW BBL Tribune LLC CC-0143-2023 4/5/2023 Floor 1 Core Reno The following comments are based on a review of submittal • Function test exit/El lighting, after renovation • Contractors shall follow all guidelines in Fire Code Chapter 33, for protection of fire and life safety devices, during construction • NFPA 72 letter of compliance required for any changes or alterations to the fire alarm system 1\(\k,,e Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fi re Marshal 's Office • Phone: 518-761-8206 • Fax: 518-745-4437 fireniarshal@queensburif.net • WWW.queensbury.net