Loading...
CC-0596-2021 4 Office Use Only . v� PRINCIPLE STRUCTURE PERMIT APPLICATION Permit#: CC. —059 tQ • 2021 Permit Fee:$ 2 .15 Town of Qucensbury r i 21.1S 742 Bay Road,Queensbury, NY 12804 *Rec Fee: $ 11 P: 518-761-8256 www.queensburynet Invoice#: 6 • Flood Zone? Y ' Reviewed B Project Location: Building #4 - 16 Whitbeck Dr. (Fowler Square) Tax Map #: Subdivision Name: *RECREATION FEE$1000.00 for new dwelling units: single family, duplexes/two-family, multiple family, apartments,condominiums, townhouses,a-NYS Building Standards & approved manufactured home. This is in addition to the permit fee(s). PROJECT INFORMATION: g. Residential ►�i Commercial, Proposed Use AUG 13 2021 ❑ — p TOW COpe RY ❑Single-Family: ❑Two-Family Multi-Family nits. 8 ) 1. ❑ Custom 2. ❑Modular(REQUIRED:NYS stamped engineered drawings of foundation plans) ❑Townhouse ❑ Garage (#of cars ) ❑ Business Office ❑ Retail ❑ Hotel/Motel ❑ Industrial ❑ Heated Warehouse/Storage Building ❑ Unheated Warehouse/Storage Building ❑Amusement Ride ❑ Other(describe: ) MAIN STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE: 1sr floor: 7,908 SF 1ST floor: 2"d floor: 7,581 SF 2"d floor: 3rd floor: Total square feet: Basement(habitable space): • Total square feet: 15,489 SF x�53 Irv3b, Principle Structure Packet Revised March 2021 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 1,918,841 2. Proposed use of the building:Apartments 3. If Commercial or Industrial, indicate the name of the business: 4. Source of Heat: Gas ❑ Oil ❑ Propane ['Solar ❑ Other: (Fireplaces need a separate Fuel Burning Appliances&Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan? ❑YES / NO Explain, if yes: 6. Are there any easements on the property? ❑ YES NO 7. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? b. Is this a corner lot? ❑ YES ►/ NO c. Will the grade be changed as a result of the construction? ❑ YES NO d. What is the water source? ill PUBLIC ❑ PRIVATE ❑ WELL e. What type of wastewater system is on the parcel? ►/ SEWER ❑ PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans, additional reviews and re-approval. 2. If,for any reason,the building permit,application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a NYSlicensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: SIGNAURE: DATE: 8/3 Principle Structure Packet Revised March 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): BBL Construction Services Mailing Address, C/S/Z: 302 Washington Avenue Ext. Albany, NY 12203 Cell Phone: Land Line: (518) 452-8200 Email: Eweatherwax@bblinc.com, retue@bblinc.com • Primary Owner(s): Name(s):Rossetti Acquisitions Mailing Address, C/S/Z:427 New Karner Road Albany, NY 12205 Cell Phone: Land Line: (518) 452-8200 Email: cfalvey@Falveygroup.com ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contractor Name(s): BBL Construction Services Contractor Trade: General Contractor Mailing Address, C/S/Z: 302 Washington Avenue Ext. Albany, NY 12203 Cell Phone: Land Line: (518) 452-8200 Email:Eweatherwax@bblinc.com, retue@bblinc.com **Workers' Comp documentation must be submitted with this application** • Architect(s)/Engineer(s): Business Name:HCP Achitects Contact Name(s): Stephen Bednarczyk Mailing Address, C/S/Z:302 Washington Avenue Ext. Albany, NY 12203 Cell Phone: Land Line:(518) 218-0614 Email:sbednarczyk@hcpdesign.com Contact Person for Compliance in regards to this project: Cell Phone: Land Line: Email: Principle Structure Packet Revised March 2021 CHECKLIST--SINGLE FAMILY Project Location: REQUIRED-2SETS 1. Building Permit application, completed YES NO N/A 2. Energy Code inspector's report from ResCheck, completed &signed ❑ ❑ ❑ 3. Septic alteration application, if applicable ❑ ❑ ❑ 4. Solid fuel burning or gas insert appliance form(s), if applicable ❑ ❑ ❑ 5. Driveway permit, if applicable ❑ ❑ ❑ 6. Structural drawings, including: a. Floor plans ❑ ❑ ❑ b. Foundation plans ❑ ❑ ❑ c. Cross sections ❑ ❑ ❑ d. Elevations ❑ ❑ ❑ e. Window&door schedule ❑ ❑ ❑ f. Natural light,ventilation & emergency egress ❑ ❑ El 7. Plot plan: showing proposed structure(s) with setback dimensions from all ❑ ❑ ❑ surveyed property lines 8. Electrical inspection agency selected ❑ ❑ ❑ CHECKLIST-- MULTI-DWELLING/COMMERCIAL Project Location: REQUIRED-2 SETS 1. Building Permit application, completed YES NO N/A 2. Energy Code inspector's report from ComCheck, completed &signed ❑ ❑ 3. Septic alteration application, if applicable ❑ ❑ 4. Solid fuel burning or gas insert appliance form(s), if applicable ❑ ❑ ►� 5. Driveway permit, if applicable ❑ ❑ ► 6. Structural drawings, including: a. Floor plans ❑ ❑ b. Foundation plans ❑ ❑ c. Cross sections � ❑ ❑ d. Elevations k:4 ❑ ❑ e. Design loads including floor, snow&wind load � ❑ ❑ 0 El f. Seismic design g. Plans signed and sealed by registered architect or engineer ❑ ❑ h. Window&door schedule 7. Plot plan: showing proposed structure(s)with setback dimensions from all e ❑ ❑ surveyed property lines 8. Electrical inspection agency selected VI' ❑ ❑ 9. FINAL AS-BUILT PLANS SUBMITTED ELECTRONICALLY Principle Structure Packet Revised March 2021 NATURAL LIGHT,VENTILATION&EMERGENCY EGRESS CALCULATION SHEET (please complete if details are not provided on plans) Project Location: Primary Owner (s): Habitable Sq. Ft. Required Actual Required Actual Sq. ft. Rooms of Light Light Ventilation Ventilation opening Room (8% of rm.) (sq. ft.) (4% of room) (sq. ft.) for Egress Master lA Bedroom 189 15.1 23.0 7.56 12.8 6.45 Bedroom 135 10.8 23.0 5,4 12.8 6.45 Kitchen/ 512 41.0 55.3 Living 20.48 29.6 Master 1B Bedroom 167 13.4 23.0 6.68 12.8 6.45 Den 85 6.8 23.0 3.4 12.8 Kitchen/ Living 432 33.8 47.9 16.92 25.2 1C Bedroom 211 16.9 23.0 8.44 12.8 6.45 Bedroom 143 11.4 23.0 5.72 12.8 6.45 Bedroom 160 12.8 23.0 6.4 12.8 6.45 Kitchen/ 608 48.6 59.4 24.32 31.6 Living 1D Master Bedroom 233 18.6 29.8 9.32 16.8 6.45 Bedroom 155 12.4 23.0 6.2 12.8 6.45 Kitchen/ Living 595 47.6 70.9 23.8 38.0 Principle Structure Packet Revised March 2021 7� y. FILE COPY COMcheck Software Version 4.1.4.3 Envelope Compliance Certificate REVIEWED FOR ENERGY CODE COMPLIANCE Project Information Energy Code: 2018 IECC Project Title: FOWLER SQUARE 8 UNIT APARTMENT BUILDING Location: Glens Falls, New York Climate Zone: 6a Project Type: New Construction D E C lip' (, J]' Vertical Glazing/Wall Area: 22% ly �C, L6 �J �—C, Construction Site: Owner/Agent: . D sig er/Contra or?021 BLIND ROCK&BAY ROAD QUEENSBURY, NY 12804 TOWN OF QUEENSBURY Additional Efficiency Package(s) BUILDING & CODES High efficiency HVAC.Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Building Area Floor Area 1-Multifamily: Residential 7908 Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor(a) Perimeter Roof 1:Attic Roof with Wood Joists,[Bldg.Use 1 -Multifamily] 7930 38.0 0.0 0.027 0.021 Floor 1:Slab-On-Grade:Unheated,Vertical 4 ft.,[Bldg.Use 1 - 7908 -- 10.0 0.480 0.520 Multifamily](d) NORTH Exterior Wall 1:Wood-Framed,16"o.c.,[Bldg.Use 1 -Multifamily] 3623 21.0 6.6 0.042 0.051 Window 1:Vinyl/Fiberglass Frame:Operable,Perf.Specs.:Product ID-, 314 -- --- 0.270 0.430 SHGC 0.26,[Bldg.Use 1 -Multifamily](c) Door 1:Other Door,Swinging,[Bldg.Use 1 -Multifamily] 168 --- --- 0.200 0.370 Door 2:Insulated Metal,Garage door 14%glazing,[Bldg.Use 1 - 512 -- --- 0.001 0.310 Multifamily] EAST Exterior Wall 3:Wood-Framed,16"o.c.,[Bldg.Use 1 -Multifamily] 1490 21.0 6.6 0.042 0.051 Window 3:Vinyl/Fiberglass Frame:Fixed,Perf.Specs.:Product ID-, 116 -- -- 0.270 0.360 SHGC 0.26,[Bldg.Use 1 -Multifamily](c) Door 4:Other Door,Swinging,[Bldg.Use 1 -Multifamily] 21 — --- 0.200 0.370 SOUTH Exterior Wall 2:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Multifamily] 3089 6.6 21.0 0.034 0.051 Window 2:Vinyl/Fiberglass Frame:Fixed,Perf.Specs.:Product ID-, 672 --- --- 0.270 0.360 SHGC 0.26,[Bldg.Use 1 -Multifamily](c) Door 3:Glass(>50%glazing):Nonmetal Frame,Entrance Door,Perf. 944 -- --- 0.270 0.770 Specs.:Product ID-,SHGC 0.26,[Bldg.Use 1-Multifamily](c) WEST Exterior Wall 4:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Multifamily] 1490 21.0 6.6 0.042 0.051 Window 4:Vinyl/Fiberglass Frame:Fixed,Perf.Specs.:Product ID-, 116 -- -- 0.270 0.360 SHGC 0.26,[Bldg.Use 1 -Multifamily](c) Project Title: FOWLER SQUARE 8 UNIT APARTMENT BUILDING Report date: 02/15/21 Data filename: C:\Users\mgiddings\Documents\COMcheck\8 UNIT FOWLER APARTMENTS.cck Page 1 of 10 l Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factoria) Perimeter (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b)'Other'components require supporting documentation for proposed U-factors. (c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (d)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope PASSES: Design 19% better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.4.3 and to comply with any applicable mandatory requirements listed in the I pection Checklist. e‘IL "541/4319-4 A/2014 Name-Titles igna ure Date ;cRED Apo tt Jot (a zr In ;r-44� �O.035'6 y0�` OF NE44 Project Title: FOWLER SQUARE 8 UNIT APARTMENT BUILDING Report date: 02/15/21 Data filename: C:\Users\mgiddings\Documents\COMcheck\8 UNIT FOWLER APARTMENTS.cck Page 2 of 10 f COMcheck Software Version 4.1.4.3 in° Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans and/or specifications provide all ❑Complies [PR1]1 information with which compliance ❑Does Not can be determined for the building envelope and document where [Not Observable exceptions to the standard are ❑Not Applicable claimed. C402.4.1 The vertical fenestration area <= 30 ❑Complies [PR10]1 percent of the gross above-grade wall ❑Does Not area. ❑Not Observable • ❑Not Applicable C402.4.1 ;The skylight area <= 3 percent of the ❑Complies [PR11]1 'gross roof area. ❑Does Not :Not Observable ❑Not Applicable C405.5 Group R-2 dwelling units have ❑Complies [PR16]1 separate electrical meters. ❑Does Not ❑Not Observable ❑Not Applicable C406 Plans,specifications, and/or ❑Complies [PR9]1 calculations provide all information ❑Does Not with which compliance can be determined for the additional energy ❑Not Observable efficiency package options. Observable,___, Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: FOWLER SQUARE 8 UNIT APARTMENT BUILDING Report date: 02/15/21 Data filename: C:\Users\mgiddings\Documents\COMcheck\8 UNIT FOWLER APARTMENTS.cck Page 3 of 10 a Section Footing/Foundation Inspection Complies? Comments/Assumptions &Req.ID C303.2 ISlab edge insulation installed per ❑Complies [FO4]2 I manufacturer's instructions. ❑Does Not ['Not Observable ❑Not Applicable C303.2.1 Exterior insulation protected against ❑Complies [FO6]1 damage, sunlight, moisture, wind, ElDoes Not landscaping and equipment maintenance activities. ❑Not Observable ❑Not Applicable C105 Installed slab-on-grade insulation type ❑Complies See the Envelope Assemblies table for values. [FO3]2 and R-value consistent with insulation ❑Does Not ,specifications reported in plans and COMcheck reports. ❑Not Observable ❑Not Applicable C402.2.4 Slab edge insulation depth/length. ❑Complies See the Envelope Assemblies table for values. [FO7]2 Slab insulation extending away from ❑Does Not building is covered by pavement or >= 10 inches of soil. ❑Not Observable ❑Not Applicable C402.2.6 Radiant heating systems panels ❑Complies See the Envelope Assemblies table for values. [FO12]3 insulated to >=R-3.5 on face opposite ❑Does Not space being heated. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: FOWLER SQUARE 8 UNIT APARTMENT BUILDING Report date: 02/15/21 Data filename: C:\Users\mgiddings\Documents\COMcheck\8 UNIT FOWLER APARTMENTS.cck Page 4 of 10 sr Section Framing/Rough-In Inspection Complies? Comments/Assumptions & Req.ID C303.1.3 ;Fenestration products rated in ❑Complies [FR12]2 accordance with NFRC. ElDoes Not ['Not Observable ❑Not Applicable C303.1.3 Fenestration products are certified as ❑Complies [FR13]1 to performance labels or certificates ElDoes Not provided. ['Not Observable • ❑Not Applicable C402.4.3 Vertical fenestration SHGC value. ❑Complies See the Envelope Assemblies table for values. [FR10]1 ElDoes Not ❑Not Observable ❑Not Applicable C402.4.3, Vertical fenestration U-Factor. ❑Complies See the Envelope Assemblies table for values. C402.4.3. . ElDoes Not 4 1 ❑Not Observable [FR8] ❑Not Applicable C402.4.4 'U-factor of opaque doors associated ❑Complies See the Envelope Assemblies table for values. [FR14]2 with the building thermal envelope ElDoes Not meets requirements. ❑Not Observable ❑Not Applicable C402.5.1. The building envelope contains a ❑Complies 2.1 continuous air barrier that is sealed in ❑Does Not [FR19]1 an approved manner and material permeability<= 0.004 dfm/ft2.Air ❑Not Observable barrier penetrations are sealed in an ❑Not Applicable approved manner. C402.5.2, Factory-built fenestration and doors ❑Complies C402.5.4 tare labeled as meeting air leakage ElDoes Not [FR18]3 !requirements. ❑Not Observable { ❑Not Applicable C402.5.7 ;Vestibules are installed on all building ❑Complies [FR17]3 entrances. Doors have self-closing ElDoes Not ;devices. ❑Not Observable } ElNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: FOWLER SQUARE 8 UNIT APARTMENT BUILDING Report date: 02/15/21 Data filename: C:\Users\mgiddings\Documents\COMcheck\8 UNIT FOWLER APARTMENTS.cck Page 5 of 10 1 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C402.5.5, (Stair and elevator shaft vents have ❑Complies C403.2.4. !motorized dampers that automatically Does Not 3 close. Refernece section C403.7.7 for [ME3]3 !operational details. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: FOWLER SQUARE 8 UNIT APARTMENT BUILDING Report date: 02/15/21 Data filename: C:\Users\mgiddings\Documents\COMcheck\8 UNIT FOWLER APARTMENTS.cck Page 6 of 10 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.6 'Low-voltage dry-type distribution ❑Complies [EL26]2 l electric transformers meet the ODoes Not ?minimum efficiency requirements of Table C405.6. ['Not Observable ❑Not Applicable C405.7 l Electric motors meet the minimum ❑Complies [EL27]2 efficiency requirements of Tables ❑Does Not C405.7(1)through C405.7(4). ❑Not Observable p Efficiency verified through certification under an approved certification ❑Not Applicable program or the equipment efficiency ratings shall be provided by motor manufacturer(where certification programs do not exist). C405.8.2, Escalators and moving walks comply ❑Complies C405.8.2. with ASME A17.1/CSA B44 and have ❑Does Not 1 automatic controls configured to [EL2812 j reduce speed to the minimum ❑Not Observable permitted speed in accordance with ❑Not Applicable ASME A17.1/CSA B44 or applicable local code when not conveying ,passengers. C405.9 STotal voltage drop across the ❑Complies [EL29]2 combination of feeders and branch ❑Does Not Icircuits <=5%. } ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: FOWLER SQUARE 8 UNIT APARTMENT BUILDING Report date: 02/15/21 Data filename: C:\Users\mgiddings\Documents\COMcheck\8 UNIT FOWLER APARTMENTS.cck Page 7 of 10 1' Section # Insulation Inspection Complies? Comments/Assumptions & Req.ID C303.1 Roof insulation installed per ❑Complies [IN3]1 manufacturer's instructions. Blown or ❑Does Not poured loose-fill insulation is installed only where the roof slope is<=3 in ❑Not Observable 12. ❑Not Applicable C402.2.1 Insulation installed on a suspended ❑Complies [IN20]1 ceiling having ceiling tiles is not being ❑Does Not specified for roor/ceiling assemblies. Continuous insulation board installed ❑Not Observable in 2 or more layers with edge joints ❑Not Applicable offset between layers. C303.1 1 Building envelope insulation is labeled ❑Complies [IN10]z with R-value or insulation certificate ❑Does Not providing R-value and other relevant data. [Not Observable ❑Not Applicable C303.2 Above-grade wall insulation installed ❑Complies [IN7]1 per manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable C303.2.1 Exterior insulation is protected from ❑Complies [IN1412 damage with a protective material. ❑Does Not Verification for exposed foundation insulation may need to occur during ❑Not Observable Foundation Inspection. ❑Not Applicable C105 Installed above-grade wall insulation ❑Complies See the Envelope Assemblies table for values. [IN6]1 type and R-value consistent with ❑Does Not insulation specifications reported in plans and COMcheck reports. ['Not Observable ❑Not Applicable C402.2.3 I Installed floor insulation type and R- ❑Complies See the Envelope Assemblies table for values. [IN8]V value consistent with insulation ❑Does Not specifications reported in plans and COMcheck reports. ❑Not Observable ❑Not Applicable C402.2.6 1 Radiant panels and associated ❑Complies [IN18]3 lcomponents, designed for heat ❑Does Not transfer from the panel surfaces to the occupants or indoor space are ['Not Observable !insulated with a minimum of R-3.5. ❑Not Applicable C105 Installed roof insulation type and R- ❑Complies See the Envelope Assemblies table for values. [IN2]1 value consistent with insulation ❑Does Not specifications reported in plans and COMcheck reports. For some ceiling ['Not Observable systems,verification may need to ❑Not Applicable occur during Framing Inspection. C402.5.1. All sources of air leakage in the ❑Complies 1 building thermal envelope are sealed, ❑Does Not [IN1]1 caulked, gasketed, weather stripped or wrapped with moisture vapor- ❑Not Observable permeable wrapping material to ❑Not Applicable minimize air leakage. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: FOWLER SQUARE 8 UNIT APARTMENT BUILDING Report date: 02/15/21 Data filename: C:\Users\mgiddings\Documents\COMcheck\8 UNIT FOWLER APARTMENTS.cck Page 8 of 10 Section # Final Inspection Complies? Comments/Assumptions &Req.ID C402.5.6 Weatherseals installed on all loading ❑Complies [FI37]1 dock cargo door openings and provide ❑Does Not direct contact along the top and sides of vehicles parked in the doorway. ['Not Observable ❑Not Applicable C402.5.6 Weatherseals installed on all loading ❑Complies [FI37]1 dock cargo door openings and provide ElDoes Not direct contact along the top and sides of vehicles parked in the doorway. ❑Not Observable ElNot Applicable C402.5.6 Weatherseals installed on all loading ❑Complies [FI37]1 dock cargo door openings and provide ❑Does Not direct contact along the top and sides of vehicles parked in the doorway. ['Not Observable ❑Not Applicable C402.5.6 ;Weatherseals installed on all loading ❑Complies [F137]1 dock cargo door openings and provide ❑Does Not direct contact along the top and sides of vehicles parked in the doorway. ❑Not Observable ❑Not Applicable C402.5.8 ;Recessed luminaires in thermal ❑Complies [F126]3 envelope to limit infiltration and be IC ❑Does Not rated and labeled.Seal between interior finish and luminaire housing. ❑Not Observable ❑Not Applicable C408.1.1 Building operations and maintenance ❑Complies [FI57]1 documents will be provided to the ❑Does Not owner. Documents will cover manufacturers' information, ❑Not Observable specifications, programming ❑Not Applicable procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and operated. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: FOWLER SQUARE 8 UNIT APARTMENT BUILDING Report date: 02/15/21 Data filename: C:\Users\mgiddings\Documents\COMcheck\8 UNIT FOWLER APARTMENTS.cck Page 9 of 10 Jv • Project Title: FOWLER SQUARE 8 UNIT APARTMENT BUILDING Report date: 02/15/21 Data filename: C:\Users\mgiddings\Documents\COMcheck\8 UNIT FOWLER APARTMENTS.cck Page 10 of 10 • 1.` == ®i wi p ; • FILE COPY 11111111111111t. . ifelydr r4LI ] ,1r, - BOWDIOG DEPARTMENT STRUCTURAL Based on our limited examination,compliance with our comments shall not be construed as ENGINEERING indicating the plans and specifications are in full compliance with the Building Codes of New York State. Structural Design Data for Building No. 4 8 Unit Apartment Building Located at 16 Whitbeck Drive Queensbury, New York • /;'.1Z,-/<' 'c'c,\1P- ‘‘c . . (,J.'?- iiii0, 4,,,,;' , ,,_ ........y 124 EAST MAIN STREET, WATERVILLE, NY 13480 315.939.1740 TELEPHONE 518.458.2600 455 PATROON CREEK BLVD, SUITE 106,ALBANY, NY 12206 W WW.260STRUCTURALENGINEERING.COM / Project Name: Fowler Square-6/8 Unit Buildings ■� ®y Project Number: 260-2024 +' ; ,� ]� ___ __;_ Project Location: Queensbury,NY EN NINEPIN ..� ENLINEE4ING UNIFORM LOADING ROOF Supported Floors Areas Live Load(Snow) Live Loads Item Units Notes Item Units Notes Private Rooms&Corridors 40.00 PSF NYS Building Code Ground Snow Load(pa) 50.00 PSF Public Rooms&Corridors 100.00 PSF NYS Building Code Exposure Factor(Ce) 1.00 none Balconies(same as occupancy served) 40.00 PSF NYS Building Code Thermal Factor(CE) 1.00 none Importance Factor(Is) 1.00 none Dead Loads-Typical Floor(wood framing) Flat Roof Snow Load(p r) 35.00 PSF Calculation Item Units Notes Ground Elevation 386.00 FEET add 2 lbs for every 100'above 1000' 3/4"plywood deck 3.00 PSF Added load due to elevation • 0.00 PSF wood framing 4.00 PSF Design Snow Load 35.00 PSF Calculation flooring 4.00 PSF 1"gypsum topping 9.00 PSF Dead Loads-Typical Roof(wood framing) insulation 1.00 PSF Item Units Notes ceiling 3.00 PSF 5/8"plywood deck ' 2.50 PSF mechanical systems 1.00 PSF wood framing 4.00 PSF, electrical systems 1.00 PSF roofing 3.50 PSF 5/8"gyp.Bd.Ceilings 3.00 PSF Total Dead Load 26.00 PSF Calculation insulation 4.00 PSF 20.00 mechanical 5.00 PSF Dead Loads-Balconies electrical systems 1.00 PSF Item Units Notes Total Dead Load 23.00 PSF Calculation composite deck boards 2.00 PSF 10.00 wood framing ,4.00 PSF soffit 4.00 PSF PSF PSF PSF Total Dead Load 10.00 PSF Calculation ■sa a„;.ter.,, Project Name: Fowler Square-6/8 Unit Buildings ��AloAli wr Project Number: 260-2024 A Y. .__`J . OJi_ _ _ _ Project Location: Queensbury,NY irwwavwc Deflection Criteria Wind Design Criteria Item Units Notes Item Units Notes Roof Members Live Load L/240 NYS Building Code Wind Speed(V) 109 MPH Dead+Live L/120 NYS Building Code Exposure Category C Floor Members Live Load NYS Building Code Dead+Live NYS Building Code Seismic Design Criteria Item Units Notes Site Class Category(soils report) D Seismic Use Group Importance Factor(le) 1 Ss 0.184 Fa 1.60 Sms(Fa*Ss) 0.294 SDS(2/3*Sms) 0.196 Seismic Design Category B from table 1613.5.6(1) S1 0.071 Fv 2.40 Sms(Fv*S1) 0.170 SDI(2/3*Sm1) 0.114 Seismic Design Category B from table 1613.5.6(2) Response Modification Factor 2 • • 11 Fowler Square 95(42) 100(45) 105{47) i, Wind Map .. ; / ,1 110(49) ��, ` = Y:..�'V .,tom : ' (40) `- , . � t il ;:�t,�•1. ^�.• �'�� ;�..� ;oft r''-� �-c , .�._ „ ti ra i, ) rd 1-:"-- r 11 ...,„,__,, j 4f. A / `j ` �...ji.. :r i " { Crosshatching on map / L. / �,- !r,.'1� �__� ` 1 indicates a Special ` t �T' _r j _ Wind Region .' �, ---1.---,T, fy((, / ,'r,,.,_._,—.,, •i fa. r __ c pi ----____+--r—.___)---1—-----::::;.AL-.;:::!-:1,'-, .._1"--111 O 7` L —�—r_ f I { Co. •::.. i 1 �' `95(42) ( ., -;� 100(45)to '� . Vl L _ 150(67) 105(47) 1�. 1� U140(63) -``j`N`,1- 105(47) .:0 . ril.111110111.1 120(54) 110(49) 103(46) • .1 CN (re, ,, VI �� This note explains why we used 109 A 4 r ''110(49) MPH for the wind speed in the 7, 1/4 lifJg Il design of Fowler Square. The --- ,Vri,-;17— -- ,(-,,,„,0,..� 120► project occurs between isobar line 2. w . '�,` . 105 and 110, closer to the 110. The r •1, ASCE Hazard report (included) g f - provides the proper wind load base ° 160(72) 62431 15.1 on live map data. I - - • 160(72) 1. Notes 1. Values are nominal design 3-s gust wind speeds in mi/h(m/s)at 33 ft(10 m)above ground for Exposure Category C. . '2. Linear interpolation is permitted between contours.Point.values are govided to aid with interpolation.) 3. Islands,coastal areas,and land boundaries outside the last contour shall use the last wind speed contour. i 4. Mountainous terrain,gorges,ocean promontories,and special wind regions shall be examined for unusual wind conditions. 5. Wind speeds correspond to approximately a 7%probability of exceedance in 50 years(Annual Exceedance Probability=0.00143,MRI=700 years). 6. Location-specific basic wind speeds shall be permitted to be determined using www.atcouncil.org/windspeed. if FIGURE 26.5-1 B Basic Wind Speeds for Risk Category If Buildings and Other Structures ti continues 252 - STANDARD ASCE/SEI 7-16 • 'i i 101(45) _ 103(46) - r� 105(47) i `¢ `T�a l _!._ L _rt \ I -r`� I i tji j-�--.. Go } 1 ri-T -P s ! i f_� ! 1 �� h P ��i �- 1 ` -- .` 115(51) 'I �-1,-f` `' ;-! L i r R - `)'1 -11_ ' 105(47) <<}�, 120(54) !f • "---{ ';--r--~- op- ,+i ,1 LT, I, ,',-1-'tc,='`/' 1., p-1- -', -Lrl- F.„4: 130(58) ;1 11:1 I I I I { 7• L� 1 ' 1 I I = `-=1 I 1-'`-f r1:1--+_'~�'�"• --1,';,'?==` - + ,1r f� 140(63) it 11 .L0..11 0L1'7AL,...i.6HI II1 k71_1-._i;.,,._,i i.,:.;-.:-,4-:r A0:l-1._.1 7,. ! '{• ems Y) '--,i,:1.f.()!i ;, I t---, _ , : t? r ct107(48) !.' 1 ,, 1 I i'+ :, _±____,-ri_.f 4-tr1r,il tilLL';,._i I L_icL..-i_1.47L'L (1 y k `_N t-1 -r _� 1 I ,-. '• Y" y ..I�� T.4 II ;I) ( ) r-)--i r- - .M,s-. ra :! :`` , ��: -'�, • 140(63) zi u_LL -1----r- '_ ' • ,-,T-'..-ti.-J._h-Lri-r- . m 'A f , o trirly_ ---7-ti_J N-.. --'4H AT1/--.. lr, _ ,..,k 1 ' We ,1 , ' .'t'46/c . ,,,/, `,L. ,71 ti,d_ 1 , i--.10,507�) r(46).•: k/'•`{� � 150(67) •• - a ' ti iiT1 I !A04(46). ' 1" % �, ,T l � i �fl11 a . 1 `o , t � SU n , -7 ..t 'tir -er, IiI-Li-! ! -r 1 547 ' 4.• _ ' ' 160(72) , 170(76) �� 170(76) 10.5(47) � 180(80) 110(49) ' t • 115(51) 150(67) ro 120(54) 140(63) 130(58) 0 P w 0 2 Location V(mph) V(m/s) Guam 195 (87) Virgin Islands 165. (74) American Samoa 160: (72) 150(67) 160(72) Hawaii See Figure 26:5-2B . 170(76) o FIGURE 26.5-1B(Continued). Basic Wind Speeds for Risk Category II Buildings and Other Structures Minimum Design Loads and Associated Criteria for Buildings and Other Structures 253 . . ASCE ASCE 7 Hazards Report AMERICAN SOCIETY OF CML ENGINEERS Address: Standard: ASCE/SEI 7-16 '.Elevation:' 386.18 ft(NAND 88 .' Fowler Square - 6/8 Unit Bldg. Risk Category: II Latitude: 43.358055 Fowler Square Boulevard Soil Class: D- Default(see Longitude: 73.658495 Queensbury, NY Section 11.4.3) ` L ,& Z ,,i-.F • . t „,,r,. /JO f EI•• I• rtarr —.. ., ��7(f- •. , "f+`{. .�•' ?= , '� � . - .. - �/-- 'l.__-- DTI•. ,..„ ; ,. , • J-A.....:i.:,;•:-.:„.Jkse./..,..,--,-_, le• . ../ 4::, _... ''...:,1. ,r.;„‘: 0. i, * -t.. ' ' '''• I 1.4'..`•'' : . ' '- ,;,!I. A _ , . „ , � ;.....Glrc Falb f�l ' {F T I I D� 'r .. :. 11''-" '`�1 ,' ;:.f't�5aR1.S0`.'L ♦ For sEri".N r i• -; t .its • �\ I' I-:.'I ,C _I, ' . 1. t I -----.-.- --_ ' i Wind Results: ,Wnd_Speedi 109 Vmph) 10-year MRI 74 Vmph 25-year MRI 80 Vmph 50-year MRI 86 Vmph 100-year MRI 92 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1 B and Figs. CC.2-1—CC.2-4 Date Accessed: Tue Sep 01 2020 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours.Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability= 0.00143, MRI =700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Mountainous terrain, gorges, ocean promontories, and special wind regions should be examined for unusual wind conditions. https://asce7hazardtool.online/ Page 1 of 6 Tue Sep 01 2020 AXE, AMERICAN SOCIETY OF CML ENGINEERS Seismic Site Soil Class: D- Default(see Section 11.4.3) Results: Ss : 0.241 SD, : 0.11 Sl : 0.069 TL : 6 Fa : 1.6 PGA : 0.135 F, : 2.4 PGA M : 0.206 Sms : 0.386 FpGA : 1.53 Sm.' : 0.165 le : 1 Sips : 0.257 C, : 0.782 Seismic Design Category B MCER Response Spectrum 0.40 , 0.30 Design Response Spectrum - , T- ! , , . , • • . . ---i , . 0.20- --:4 ' I , 0.25 - r, • , ) . 0.20- . i . — , 0.15 'S..' S - - i 0_15 3 ' ''' '' 1 0.10 ' .3‘,, - 1 . 1 0.05 , , '. '- , -- - - •:,------ __ - ' 0-05 ,-x,----:—...,_ -- - -j- ----- - - ' - -- A '' .•'' o 0 O., -. .4-,..- . _''44,4'1....ri' -.1700.- I I 1 2 3 4 5 6 1 Z 3 4 5 6 Sa(g)vs T(s) Sa(g)vs T(s) MCER Vertical Response Spectrum Design Vertical Response Spectrum 0.25 —' — 0.18 r- , . ; 0.16 — - i 0.20 0 14 4—0.15- 0_12 - • • . , t , , .z... . 0.10.. ' 0.10 ''' , ' ,' • 0.08-- s. 0.06- : , L . .., 0 05- , _ - : ,,... ' • '''''''(:."-a..• —f. 0_0 0 1 —. • .. . . a a '3.. ,, , 'I. /.:e : . :"....''.#,.. " 0.02_ i ...I:,...*, •- - -,,- • ' 'i ..-,.r.t*t- ;kw:. I 1 , 0 5 1.0 1.5 2_00 5 1.0 1 5 20 Sa(g)vs T(s) Sa(g)vs T(s) Data Accessed: Tue Sep 01 2020 Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-16 and ASCE/SEI 7-16 Table 1.5-2.Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-16 Ch. 21 are available from USGS. https://asce7hazardtooLonline/ Page 2 of 6 Tue Sep 01 2020 ASCE, AMERICAN SOCIETY OF CML ENGINEERS Ice Results: Ice Thickness: 1.00 in. Concurrent Temperature: 5 F Gust Speed: 40 mph Data Source: Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8 Date Accessed: Tue Sep 01 2020 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Snow Results: Ground Snow Load, pg_I 50 lb/fir Elevation:; 386.2 ft:, Data Source: ASCE/SEI 7-16, Table 7.2-8 Date Accessed: Tue Sep 01 2020 Values provided are ground snow loads. In areas designated"case study required," extreme local variations in ground snow loads preclude mapping at this scale. Site-specific case studies are required to establish ground snow loads at elevations not covered. https://asce7hazardtool.online/ Page 3 of 6 Tue Sep 01 2020 ASCE, AMERICAN SOCIETY OF CIVIL ENGINEERS Rain Results: 15-minute Precipitation Intensity: 5.48 in./h 60-minute Precipitation Intensity: 2.37 in./h Data Source: NOAA National Weather Service, Precipitation Frequency Data Server,Atlas 14 (https://www.nws.noaa.dov/oh/hdsc/) Date Accessed: Tue Sep 01 2020 https://asce7hazardtool.online/ Page 4 of 6 Tue Sep 01 2020 ASCE. AMER ICAN SOCIETY OF MIL ENGINEERS Flood Results: Flood Zone Categorization: Some areas are not in the National Flood Hazard Layer. Consult the Authority Having Jurisdiction. Base Flood Elevation: Refer to map for local elevations and interpolate according to the Authority Having Jurisdiction. Data Source: FEMA National Flood Hazard Layer- Effective Flood Hazard Layer for US, where modernized (https://msc.fema.gov/portal/search) Date Accessed: Tue Sep 01 2020 FIRM Panel: If available, download FIRM panel here Insurance Study Note: Download FEMA Flood Insurance Study for this area here • • 11-1 f• -.1=1 .41;,1 -. J . 4 ' ' ,:! i rr https://asce7hazardtool.online/ Page 5 of 6 Tue Sep 01 2020 AXE • AMERICAN SOCIETY OF CIVIL ENGINEERS The ASCE 7 Hazard Tool is provided for your convenience,for informational purposes only,and is provided"as is"and without warranties of any kind.The location data included herein has been obtained from information developed,produced,and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard.While ASCE has made every effort to use data obtained from reliable sources or methodologies,ASCE does not make any representations or warranties as to the accuracy,completeness,reliability, currency,or quality of any data provided herein.Any third-party links provided by this Tool should not be construed as an endorsement, affiliation,relationship,or sponsorship of such third-party content by or from ASCE. ASCE does not intend,nor should anyone interpret,the results provided by this Tool to replace the sound judgment of a competent professional,having knowledge and experience in the appropriate field(s)of practice,nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool,you expressly assume all risks associated with your use.Under no circumstances shall ASCE or its officers,directors, employees,members,affiliates,or agents be liable to you or any other person for any direct,indirect,special,incidental,or consequential damages arising from or related to your use of,or reliance on,the Tool or any information obtained therein.To the fullest extent permitted by law,you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. https://asce7hazardtool.online/ Page 6 of 6 Tue Sep 01 2020 11.11111111111111 1.111.1111111111 .... I w p ' " .. 1 STRUCTURAL ENGINEERING Fowler Square — 6/8 Units Buildings 260-2024A Queensbury, NY Wind Loading Summary The design wind pressures for the building were determined using the Directional Procedure for Enclosed, Partially Enclosed and Open Buildings of all Heights as described in Table 27.2-1 of ASCE 7-16. The wind pressures used to determine the total wind load in pounds (Ibs)each floor level were determined using the load case that created the greatest effect on the building.The total wind load at each floor level is as follows: Wind Loading Total Load (Ibs) Floor Level N/S E/W Second Floor 31,420 94,400 Roof 20,770 62,400 1 124 EAST MAIN STREET, WATERVILLE, NY 13480 315.939.1740 TELEPHONE 51 8.458.2600 455 PATROON CREEK BLVD, SUITE 106,ALBANY, NY 12206 WWW.260STRUCTURALENGINEERING.COM Project Name: Fowler Sq-6/8 Unit Bldg ■ ■■a� ■ ■■�,, ;: Project Number: 260-2024A S ■I Project Location: Queensbury, NY sTRucruRaL ENGINEERING 1>n 30%I MAIN 51xtf I,\541IUVILLL,NY 11JNU 315.919.I140 MOHO?. ,•IG82000 +-,s xnrxwn cxu v,el vn,ninnwv�Nv I,e ol, H W W,i10!i xI1C I Uxnl I,N1:11111 xlNt.,.OM Wind &Seismic Load Distribution for Bracing Element X direction Length of wall 160 ft Number of bracing elements 3 Bracing Tower Forces (Kips) TOTAL LOAD (Kips) 1 2 3 Check Percent of total load 40.00% 20.00% 40.00%: 100.00%: Roof 62.4 24.960 12.480 24.960; 62.400` 2nd Floor 94.4 37.760 18.880 37.760 94.400 Y direction Length of wall 53.25 ft Number of bracing elements 2 Bracing Tower Forces (Kips) TOTAL LOAD (Kips) 1 2 3 Check Percent of total load 50.00% 50.00% 0.00%' 100.00% Roof 20.77 10.385 10.385 0.000, 20.770 2nd Floor 31.42 15.710 15.710 0.000 31.420, Project Name: Fowler Square-6/8 Unit Bldg Project Number: 260-2024A Envelope Procedure Project Location: Queensbury, NY 28.2 Part 1: Enclosed and Partially Enclosed Low-Rise Buildings per ASCE 7-16 Enclosure Classification= Enclosed Structure being designed= Buildings Building Occupancy Category= 2 Building Exposure Category= C Dimension normal to wind direction, B (ft)= 53.25 Dimension of parallel to wind direction, L (ft) = 160.00 Mean height of building,h (ft)= 38.625 width of pressure coefficient zone, a (ft)= 2a (ft)= _ . 4a (ft)= Velocity Pressure Exposure Coefficient, k = Wind Directionality Factor,kd = ,. Topographic Factor,k2t = 1.00 >No escarpments, hills or other extreme Ground Elevation Factor, Ke = 1.00 Basic Wind Speed, V (mph)= 109 Velocity pressure, qZ (Ib/ft2)= Internal pressure coefficient and Gust factor, GC p, = Roof Angle, O (Degrees) = 0 Load Case A(Wind Perpendicular to Long Face of Building) Wall Roof 1 4 1E 4E 2 3 2E 3E GC pf 0.40 -0.29 0.61 -0.43 -0.69 -0.37 -1.07 -0.53 Design Pressures,p = 5.89 -12.59 11.52 -16.34 -23.30 -14.73 -33.48 -19.02 Design Pressures,p = 15.53 -2.95 21.16 -6.70 -13.66 -5.09 -23.84 -9.37 Middle Zones Corner Zones Total Force on Building= 18.48 27.85 Project Name: Fowler Square-6/8 Unit Bldg Project Number: 260-2024A Project Location: Queensbury, NY Load Case B(Wind Perpendicular to Narrow Face of Building) Wall Roof 1 4 1E 4E 5 6 5E 6E 2 3 2E 3E GCpf -0.45 -0.45 -0.48 -0.48 0.40 -0.29 0.61 -0.43 -0.69 -0.37 -1.07 -0.53 Design Pressures,p = -16.87 -16.87 -17.68 -17.68 5.89 -12.59 11.52 -16.34 -23.30 -14.73 -33.48 -19.02 Design Pressures,p = -7.23 -7.23 -8.03 -8.03 15.53 -2.95 21.16 -6.70 -13.66 -5.09 -23.84 -9.37_ Middle Zones Corner Zones Total Force on Building= 18.48 27.85 Project Name: Fowler Square - 6/8 Unit Type: 3-2x6's Project Number: 260-2024A Project Location: Queenbury, NY Design Calculator for Simple Span SS lumber Simple Span Cantilever ft in ft in L 3 0 0 0 LL Wn (Ib/ft^2) 40 40 DL Wn (Ib/ft^2) 26 20 Floor Members Tributary Area (in) 193.5 36 LL A L/ 360 R1 1866.38 DL A L/ 240 R2 1866.38 Mn@ Zero Shear 1399.78 LL Ireq'd = 8.39651786 Mn@R2 0.00 Tot I req'd= 9.23616964 Fb 875.00 E (psi) 1,400,000 Sx req'd 19.20 Live Load A Total Load A Size Sx available Sx req'd I (in^4) (in) L/ (in) L/ 1 2x4 3.06 12.798 5.359 0.16 230 0.26 140 N.G 1 2x6 7.56 14.767 20.8 0.04 892 0.07 541 N.G 1 2x8 13.14 15.998 47.63 0.02 2043 0.03 1238 N.G 1 2x10 21.39 17.452 98.93 0.01 4242 0.01 2571 Ok 1 2x12 31.64 19.197 178 0.00 7632 0.01 4626 Ok 2 2x4 6.12 12.798 10.718 0.08 460 0.13 279 N.G 2 2x6 15.12 14.767 41.6 0.02 1784 0.03 1081 Ok 2 2x8 26.28 15.998 95.26 0.01 4085 0.01 2476 Ok 2 2x10 42.78 17.452 197.86 0.00 8484 0.01 5142 Ok 2 2x12 63.28 19.197 356 0.00 15264 0.00 9251 Ok Project Name: Fowler Square - 6/8 Unit Type: 3-2x10's Project Number: 260-2024A Project Location: Queenbury NY Design Calculator for Simple Span SS lumber Simple Span Cantilever ft in ft in L 5 10 0 0 LL Wn (Ib/ft^2) 40 40 DL Wn (Ib/ft^2) 26 20 Floor Members Tributary Area (in) 169.5 36 LL A L/ 360 R1 3244.06 DL.A L/ 240 R2 3244.06 Mn@ Zero Shear 4730.92 LL Ireq'd= 54.0722656 Mn@R2 0.00 Tot I req'd= 59.4794922 Fb 875.00 E(psi) 1,400,000 Sx req'd 64.88 Live Load A Total Load A Size Sx available Sx req'd I (in^4) (in) L/ (in) L/ 1 2x4 3.06 43.254 5.359 1.96 36 3.24 22 N.G 1 2x6 7.56 49.909 20.8 0.51 139 0.83 84 N.G 1 2x8 13.14 54.068 47.63 0.22 318 0.36 193 N.G 1 2x10 21.39 58.983 98.93 0.11 659 0.18 400 N.G 1 2x12 31.64 64.881 178 0.06 1186 0.10 719 N.G 2 2x4 6.12 43.254 10.718 0.98 72 1.62 44 N.G 2 2x6 15.12 49.909 41.6 0.25 277 0.42 168 N.G 2 2x8 26.28 54.068 95.26 0.11 635 0.18 385 N.G 2 2x10 42.78 58.983 197.86 0.05 1318 0.09 799 N.G 2 2x12 63.28 64.881 356 0.03 2371 0.05 1437 N.G Project Name: Fowler Square - 6/8 Unit Type: 3-2x12's Project Number: 260-2024A Project Location: Queenbury, NY Design Calculator for Simple Span SS lumber Simple Span Cantilever ft in ft in L 5 10 0 0 LL Wn (Ib/ft^2) 40 40 DL Wn (Ib/ft"2) 26 20 Floor Members Tributary Area (in) 196.375 36 LL A L/ 360 R1 3675.18 DL A L/ 240 R2 3675.18 Mn@ Zero Shear 5359.64 LL Ireq'd= 62.6456706 Mn@R2 0.00 Tot I req'd= 68.9102376 Fb 875.00. E (psi) 1,400,000 Sx req'd 73.50 Live Load A Total Load A Size Sx available Sx req'd I (in^4) (in) L/ (in) L/ 1 2x4 3.06 49.002 5.359 2.27 31 3.75 19 N.G 1 2x6 7.56 56.541 20.8 0.59 120 0.97 73 N.G 1 2x8 13.14 61.253 47.63 0.26 274 0.42 166 N.G 1 2x10 21.39 66.821 98.93 0.12 569 0.20 345 N.G 1 2x12 31.64 73.504 178 0.07 1023 0.11 620 N.G 2 2x4 6.12 49.002 10.718 1.14 62 1.88 38 N.G 2 - 2x6 15.12 56.541 41.6 0.29 240 0.48 145 N.G 2 2x8 26.28 61.253 95.26 0.13 548 0.21 332 N.G 2 2x10 42.78 66.821 197.86 0.06 1138 0.10 690 N.G 2 2x12 63.28 73.504 356 0.03 2046 0.06 1240 N.G Project Name: Fowler Square - 6/8 Unit 260-2024A Type: 3-2x12s Project Number: Project Location: Queenbury, NY Design Calculator for Simple Span 1.9E LVLs Simple Span Cantilever ft in ft in L 7 2 0 0 LL Wn(Ib/ft^2) 40 40 DL Wn(Ib/ft^2) 26 20 Floor Members Tributary Area(in) 193.5 36 LL A L/ 360 R1 4458.56 DL A L/ 240 R2 4458.56 Mn@ Zero Shear 7988.26 LL Ireq'd= 100.0375905 Mn@R2 0 Tot I req'd= 108.4721324 E(psi) 1,900,000 Size Ma Mn I (in^4) Live Load A(in) L/ Total Load A(in) L/ 2 5.5 4250 7988.26 24 0.50 173 0.81 107 N.G 2 7.25 7110 7988.26 56 0.21 404 0.35 248 N.G 2 9.25 11200 7988.26 115 0.10 828 0.17 509 Ok 2 9.5 11770 7988.26 125 0.10 900 0.16 554 Ok 2 11.25 16140 7988.26 208 0.06 1498 0.09 921 Ok 2 11.875 17850 7988.26 244 0.05 1757 0.08 1080 Ok 2 14 24260 7988.26 400 0.03 2879 0.05 1771 Ok 2 16 31110 7988.26 597 0.02 4297 0.03 2642 Ok 2 18 38750 7988.26 851 0.01 6125 0.02 3766 Ok 2 20 47160 7988.26 1167 0.01 8400 0.02 5165 Ok Project Name: Fowler Square - 6/8 Unit Type: 3-9 1/4" Ivi's Project Number: 260-2024A Project Location: Queenbury, NY Design Calculator for Simple Span 1.9E LVLs Simple Span Cantilever ft in ft in L 9 0 0 0 LL Wn (Ib/ft"2) 40 0 DL Wn (Ib/ft^2) 26 0 Floor Members Tributary Area (in)• 223.5 0;LL A L/ 360 R1 5531.63 DL A L/ 240 R2 5531.63 Mn@ Zero Shear 12446.16 LL Ireq'd= 192.9452• Mn@R2 0 Tot I req'd= 212.2397 E(psi) 1,900,000 Sx req'd 170.69 Live Load Total Load Size Ma Mn I (in^4) A(in) L/ A(in) L/ 2 5.5 4250 12446.16 24 1.21 90 1.99 55 N.G 2 7.25 7110 12446.16 56 0.52 209 0.85 127 N.G 2 9.25 11200 12446.16 115 0.25 430 0.42 261 N.G 2 9.5 11770 12446.16 125 0.23 467 0.38 283 N.G 2 11.25 16140 12446.16 208 0.14 777 0.23 471 Ok 2 11.875 17850 12446.16 244 0.12 911 0.20 552 Ok 2 14 24260 12446.16 400 0.07 1493 0.12 905 Ok 2 16 31110 12446.16 597 0.05 2228 0.08 1351 Ok 2 18 38750 12446.16 851 0.03 3176 0.06 1925 Ok 2 20 47160 12446.16 1167 0.02 4355 0.04 2640 Ok