IM Inspection Worksheet_20-12-2023_15-18-33INSPECTION WORKSHEET (RESFINAL-029532-2023)
RC-0341-2023Case Number:Case Module:Permit Management
12/20/2023 PassedInspection Status:Inspection Date:
Residential Final InspectionInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:11 Pershing Rd
Queensbury, NY 12804
302.14-1-19
Company Name NameContact Type
Applicant Cerrone Builders Inc
Contractor Cerrone Builders Inc
Engineer Daniel Ryan
Granted Permission JENNIFER HASKINS KRAUSE
Primary Owner JENNIFER HASKINS KRAUSE
Checklist Item CommentsPassed
Low flow toilet 1.3 gal/flushing cycle True
Bathroom Fans, if no window True
3" Plumbing Vent through roof minimum 18 inch True
Grade away from foundation: 6" down, 10' out True
Final Survey Plot Plan True to be provided / received 12/20/23
Window guards req:<2' above floor/6' above grade True
Interior privacy/trim/doors/main entrance 36 True
Backflow Preventors where required True
Basement wall insulation R- value verified True
Emergency egress below grade True
Intake Openings True
Safety glazing: w/in 5' of tub/shower True
Seals on Garage Doors, esp. Wood True
Not less than 3' horiz from opening of bthrn True
Attic Access Insulation = Attic R- Value True
Gas Shut-off Exposed & Regulator 12" min abv grd True
Platform at all exterior doors True
Garage Floor Pitched True
Inter Connected True
Arc Fault Breaker Habitable Spaces True
Energy Sticker on Elec. Panel:R-Val. & Heating Sys True
Furnace/Hot Water Heater operating True
Fresh Air Intake True
Basement stairs closed rise greater than 4 inches True
Outside every bedroom area True
Blower Door Test Certification True
Fin Elect; Energy Saving Light Bulbs 90 Percent True
Heat detector in garage True
Gas Log In Sealed or Glass Enclosure False N/A
December 20, 2023 Page 1 of 2
INSPECTION WORKSHEET (RESFINAL-029532-2023)
Checklist Item CommentsPassed
OK to Issue C/O True O/K to issue C/O upon approval of final survey
Truss ID Signage Installed at Electrical Meter True
Range Hood 400+ cfm-Fresh Air REQUIRED True
4 inch Building Number Address visible from road True
Attic Access Gasketed True
Jack posts in basement lagged at top and bottom True
6" clearance to sill plate True
20 Minute Fire Door/Self-Closing Hardware True
Every level, Every bedroom True
Furnace shut-off w/in 30 ft. or w/in line of site True
within 10' of all sleeping areas True
on all levels w/gas appliances (i.e. furnace)True
Relief Valve ,Heat Trap/Water Temp 110 deg or less True
Electronic as-builts False
1/2" Gypsum or House Wall and Gable True
Basement Egress: 5s.f. window w/sill or Bilco door True
Bathroom / Kitchen Watertight True
HRV or ERV Installed per Bedroom Requirements True
Duct work sealed properly True
Foundation insulation to floor True
As Built Septic System False N/A existing system
Outside Spigots have Air Gap True
All Hot Water Systems: 3/4" or larger piping R-3 True
General Comments False
Guards at stairs,decks,patios 30" + above grade False N/A
Flex Gas Pipe Bonding True
Handrail 4 or more risers True
Carbon Monoxide Detectors:True
Handrail Termination at Newell Post or Wall True
Fresh air supply 3' from grade True
Battery backup True
Roof Complete / Exterior Finish Complete True
Encl. Stairs Sheetrock Underside minimum ½ Gypsum False N/A
Interior/Exterior Railings 34 to 38 True
Plumbing fixtures True
Smoke Detectors:True
Attic Access 22 x 30 minimum True
Guard at stairwell at 34" or more True
December 20, 2023 Page 2 of 2