IM Inspection Worksheet_20-12-2023_15-18-33INSPECTION WORKSHEET (RESFINAL-029532-2023) RC-0341-2023Case Number:Case Module:Permit Management 12/20/2023 PassedInspection Status:Inspection Date: Residential Final InspectionInspection Type:Inspector:Charles Dyer Job Address:Parcel Number:11 Pershing Rd Queensbury, NY 12804 302.14-1-19 Company Name NameContact Type Applicant Cerrone Builders Inc Contractor Cerrone Builders Inc Engineer Daniel Ryan Granted Permission JENNIFER HASKINS KRAUSE Primary Owner JENNIFER HASKINS KRAUSE Checklist Item CommentsPassed Low flow toilet 1.3 gal/flushing cycle True Bathroom Fans, if no window True 3" Plumbing Vent through roof minimum 18 inch True Grade away from foundation: 6" down, 10' out True Final Survey Plot Plan True to be provided / received 12/20/23 Window guards req:<2' above floor/6' above grade True Interior privacy/trim/doors/main entrance 36 True Backflow Preventors where required True Basement wall insulation R- value verified True Emergency egress below grade True Intake Openings True Safety glazing: w/in 5' of tub/shower True Seals on Garage Doors, esp. Wood True Not less than 3' horiz from opening of bthrn True Attic Access Insulation = Attic R- Value True Gas Shut-off Exposed & Regulator 12" min abv grd True Platform at all exterior doors True Garage Floor Pitched True Inter Connected True Arc Fault Breaker Habitable Spaces True Energy Sticker on Elec. Panel:R-Val. & Heating Sys True Furnace/Hot Water Heater operating True Fresh Air Intake True Basement stairs closed rise greater than 4 inches True Outside every bedroom area True Blower Door Test Certification True Fin Elect; Energy Saving Light Bulbs 90 Percent True Heat detector in garage True Gas Log In Sealed or Glass Enclosure False N/A December 20, 2023 Page 1 of 2 INSPECTION WORKSHEET (RESFINAL-029532-2023) Checklist Item CommentsPassed OK to Issue C/O True O/K to issue C/O upon approval of final survey Truss ID Signage Installed at Electrical Meter True Range Hood 400+ cfm-Fresh Air REQUIRED True 4 inch Building Number Address visible from road True Attic Access Gasketed True Jack posts in basement lagged at top and bottom True 6" clearance to sill plate True 20 Minute Fire Door/Self-Closing Hardware True Every level, Every bedroom True Furnace shut-off w/in 30 ft. or w/in line of site True within 10' of all sleeping areas True on all levels w/gas appliances (i.e. furnace)True Relief Valve ,Heat Trap/Water Temp 110 deg or less True Electronic as-builts False 1/2" Gypsum or House Wall and Gable True Basement Egress: 5s.f. window w/sill or Bilco door True Bathroom / Kitchen Watertight True HRV or ERV Installed per Bedroom Requirements True Duct work sealed properly True Foundation insulation to floor True As Built Septic System False N/A existing system Outside Spigots have Air Gap True All Hot Water Systems: 3/4" or larger piping R-3 True General Comments False Guards at stairs,decks,patios 30" + above grade False N/A Flex Gas Pipe Bonding True Handrail 4 or more risers True Carbon Monoxide Detectors:True Handrail Termination at Newell Post or Wall True Fresh air supply 3' from grade True Battery backup True Roof Complete / Exterior Finish Complete True Encl. Stairs Sheetrock Underside minimum ½ Gypsum False N/A Interior/Exterior Railings 34 to 38 True Plumbing fixtures True Smoke Detectors:True Attic Access 22 x 30 minimum True Guard at stairwell at 34" or more True December 20, 2023 Page 2 of 2