IM Inspection Worksheet_04-01-2024_15-17-38INSPECTION WORKSHEET (RESFINAL-000038-2024) RC-0714-2022Case Number:Case Module:Permit Management 01/04/2024 Partial PassInspection Status:Inspection Date: Residential Final InspectionInspection Type:Inspector:Charles Dyer Job Address:Parcel Number:4 Onondaga Dr Queensbury, NY 12804 239.8-1-49 Company Name NameContact Type Applicant William Mason Architect Eric Teras Contractor Takundewide Management Group Inc. (TMG INC) Granted Permission ROBERT FINEGOLD Primary Owner Ruth Finegold Checklist Item CommentsPassed bedroom(s) with gas appliances False Low flow toilet 1.3 gal/flushing cycle True Bathroom Fans, if no window True 3" Plumbing Vent through roof minimum 18 inch True Grade away from foundation: 6" down, 10' out True Final Survey Plot Plan False to be provided Window guards req:<2' above floor/6' above grade False Interior privacy/trim/doors/main entrance 36 True Backflow Preventors where required True Basement wall insulation R- value verified True Emergency egress below grade True Safety glazing: w/in 5' of tub/shower False N/A Site Plan / Variance required True to be provided Not less than 3' horiz from opening of bthrn False Attic Access Insulation = Attic R- Value True Gas Shut-off Exposed & Regulator 12" min abv grd False propane Platform at all exterior doors True Inter Connected True Arc Fault Breaker Habitable Spaces True Energy Sticker on Elec. Panel:R-Val. & Heating Sys False Furnace/Hot Water Heater operating True Hot water drain pan to indirect waste False Fresh Air Intake True Chimney Rain Cap Installed True Basement stairs closed rise greater than 4 inches True Foam in basement/attics covered w/thermal barrier True Outside every bedroom area True Oil Furnace Shut-Off at Entrance to Furnace Area False Blower Door Test Certification False to be provided January 04, 2024 Page 1 of 2 INSPECTION WORKSHEET (RESFINAL-000038-2024) Checklist Item CommentsPassed Fin Elect; Energy Saving Light Bulbs 90 Percent True Gas Log In Sealed or Glass Enclosure True Kozy heat / model-Bay 36 L / serial # 23114815 04 OK to Issue C/O False Truss ID Signage Installed at Electrical Meter False Range Hood 400+ cfm-Fresh Air REQUIRED False 4 inch Building Number Address visible from road True Attic Access Gasketed True Guard at deck, porches 36" or more False 6" clearance to sill plate True Propane Tank: Proper Setback from Prop Line/Struct True Every level, Every bedroom True Furnace shut-off w/in 30 ft. or w/in line of site False electric split system Floor truss, draft stop- fin base 1,000 sq. ft.False within 10' of all sleeping areas True on all levels w/gas appliances (i.e. furnace)False Relief Valve ,Heat Trap/Water Temp 110 deg or less True Electronic as-builts False Basement Egress: 5s.f. window w/sill or Bilco door True Bathroom / Kitchen Watertight True HRV or ERV Installed per Bedroom Requirements True Duct work sealed properly False N/A Foundation insulation to floor True CSST/other piping in conduit if buried,if required False As Built Septic System True All Hot Water Systems: 3/4" or larger piping R-3 True Handrail 4 or more risers False Encl. Stairs Sheetrock Underside minimum ½ Gypsum True Handrail Termination at Newell Post or Wall False Smoke Detectors:True Plumbing fixtures True General Comments False Guard at stairwell at 34" or more False Interior/Exterior Railings 34 to 38 True interior yes Carbon Monoxide Detectors:True Attic Access 22 x 30 minimum True Outside Spigots have Air Gap True OK to Issue Temporary C/O False Roof Complete / Exterior Finish Complete True Battery backup True Flex Gas Pipe Bonding False Guards at stairs,decks,patios 30" + above grade False as discussed / provide guards, handrail at exterior platforms January 04, 2024 Page 2 of 2