231736_20231222_CFI_0000232947Client:
Project:
Technician:
Date:
Weather:
1471 ST RT 9 LLC
1471 ST RT 9, Lake George NY
Clear
Friday, December 22, 2023
Tyler Michaud
Client Rep.:Russ Faden
Temperature: AM 20-32 °F10-20 °F PM
Arrival Time:
9:30 AM
7:30 AM
Project Number:
Contractor:
Contractor Rep.:
231736
Boucher
Russ Faden Departure Time:
Concrete Field Report (ASTM C31, C143, C231 or C173, C1064, C138; AASHTO T23, T119, T152 or T196, T309, T121)Page 1 of 1
3348 Route 208, Campbell Hall, NY 10916 ■ Phone: 845-496-1600 ■ Fax: 845-496-1398
12960 Commerce Lake Dr #14, Ft Myers, FL 33913 ■ Phone: 239-204-4569
1813 State Route 7, Harpursville, NY 13787 ■ Phone: 607-235-2006
877 US-4, Schuylerville, NY 12871 ■ Phone: 518-372-4067
Report Reviewed By: Jack Harrison
Mix Details
Supplier Strength Cylinder Type Initial Curing Method Mix Design
Pallette Stone Corp, Saratoga Springs 3500 PSI @ 28 Days 4 x 8 Cylinder Curing Box 3500
Project Specifications (Available Via Drawings On Site)
Structure Type Slump Slump w/MRWR Slump w/HRWR Air Content Unit Weight Mix Temp Maximum Mix Time
Footings 6.00 in. max 4.0 - 7.0 %
Placement Information
Load
Num.
Truck
Num.
Ticket
Num.
Cubic
Yards
Total
Yards
Time
Loaded
Time
Arrived
Time
Discharged
Time
Completed Slump Air
Content
Unit
Weight
Mix
Temp
Air
Temp
H20
Added
Num
Cyls Location
1 4912 14969 11 11 7:13 AM 8:00 AM 8:10 AM 8:30 AM 5.00 in.5.0 %65 °F 15 °F 6 Half of South footing and
all of East Footing
2 4913 14970 11 22 7:45 AM 8:20 AM 8:35 AM 9:05 AM North Footing
3 4525 14973 10 32 8:09 AM 8:50 AM 9:05 AM 9:30 AM
West Footing and
remaining half of South
Footing.
Batch tickets were not available for review.
All tests within specifications.
Comments
Mid Range Water-Reducer and 2% Non Chloride was added into the mix.
General Location of Work:
All Footings
Technician Signature:Date:Friday, December 22, 2023
ACT-CFI-1, Rev 2, 10/13/20The results identified in this report relate only to the items sampled/tested.
No representation is made that materials or items not sampled and tested will produce the same or similar results.
This report shall not be reproduced, except in full, without the prior written approval of Advance Testing Company.