CC-0472-2022 Office Use Only ADDITION/ALTERATION PERMIT Permit#: C —04'2- APPLICATION Permit Fee:$ '2 t4 .115 Town of Queensbury 11` s 742 Bay Road,Queensbury,NY 12804 Invoice#: "J�J� P:518-761-8256 www.queensbury.net -, Flood Zone? Y /Reviewed By: /I Project Location: 257 Dix Ave C/ Tax Map ID#: 303.15-1-3 Subdivision Name: PROJECT INFORMATION: TYPE: Residential X Commercial, Proposed Use: Automotive sales & service Single-Family Two-Family Multi-Family(#of units ) _Townhouse Business Office _Retail Industrial/Warehouse Garage (#of cars_) _Other(describe ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 6,707 1st floor: 2nd floor: 1,620 2nd floor: 3rd floor: 3rd floor: Basement(habitable space): Basement(habitable space): Total sq ft: 8,327 Total sq ft: Scope of work to be done: Addition to Garvey Hyundai to include new detail bays, new service drop off and carwash facility. Additional office space to be added above existing office block. Interior finishes will be modified in accordance with Hyundai Motor Corporation rebranding color scheme to inlcude new paint, furniture and interior floor finishes in showroom, service advisor and parts area, all customer touch pionts are to be upgraded per Hyundai Motor Corporation requirements. JUL 28202 TOWN OF QU{rl :, Ui",Y Addition/Alteration Application Revised January 2021 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ $2,000,000 2. Source of Heat(circle one): x Gas Oil Propane Solar Other Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? YES x NO Explain: 4. Are there any easements on the property? YES X NO SITE INFORMATION: • Is this a corner lot? YES X NO • Will the grade be changed as a result of the construction? YES X _NO • What is the water source? X PUBLIC PRIVATE WELL • What type of wastewater system is on the parcel? X SEWER PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date,100%of the fee is retained. 3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. I certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Ethan P. Hall --1 Architect\Agent for the Applicant �� Yr SIGNATURE: P DATE: 27 July 2022 Addition/Alteration Application Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Garvey Sisters, LLC Mailing Address, C/S/Z: 257 Dix Ave, Queensbury NY 12804 Cell Phone: ( ) Land Line: (518 )792-9003 Email: mdgmdg1@gmail.corn • Primary Owner(s): Name(s): Garvey Sisters, LLC Mailing Address, C/S/Z: 257 Dix Ave, Queensbury NY 12804 Cell Phone: ( ) Land Line: (518 )792-9003 Email: mdgmdgl gmail.com ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Tom Albrecht, Jr. -Hilltop Construction Contractor Trade: General Contractor-All work to be performed by Hilltop Construction Mailing Address, C/S/Z: 51 Crowley Road, Hudson Falls NY 12839 Cell Phone: ( .ri1R )258-9327 Land Line: ( 51a )798-0338 Email: tomjr@hilltopconstructionco.com **Workers' Comp documentation must be submitted with this application** • Architect(s)/Engineer(s): Business Name: Rucinski Hall Architecture Contact Name(s): Ethan P. Hall Mailing Address, C/S/Z: 134 Dix Ave, Glens Falls NY 12801 Cell Phone: ( 518 )260-2888 Land Line: ( 518 )741-0268 Email: ephall@nycapsr.com Contact Person for Compliance in regards to this project: Ethan P. Hall Cell Phone: ( 518 )260-2888 Land Line: (gig )741-0268 Email: Pphall rr(�nyrap rr ram Addition/Alteration Application Revised January 2021 FIRE MARSHAL'S OFFICE ._• Town of Queensbury 742 Bay Road, Queensbury, NY 12804 "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Garvey Hyundai 257 Dix Avenue CC-0472-2022 8/8/2022 The following comments are based on review of drawings: • Verify fire extinguisher locations throughout • Locks / latches must comply with 2020 IFC • Verify function of all exit and emergency lighting, including exterior • Truss ID signage required • Add Knox box to new main entry door. Add additional keys as needed • Verify CO detection Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fire Marshal 's Office • Phone: 518-761-8206 • Fax: 518-745-4437 firemarshal@queensbunj.net • www.queensbunj.net Right-J8® Form J1Si Job: Entire House aw S CA Date: Sep 07,2022 1 By. Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@themialassociates.com Web:www.thermalassociates.com 1 Name of Room Entire House Room4 2 Running Feet of Exposed Wall 179.0 ft 70.0 ft 3 Ceiling Ht(Ft)and Gross Wall Area(sgFt) 17.5 ft 7848.9 ft' 9.0 ft 1260.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 7801.0 ft' 63.0 x 7.0 ft 441.0 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 ° 7801.0 ft' 0 ° 441.0 ft' I 1 1 I I Type of Const., Panel HTM Area or I Btuh Area or I Btuh I Exposure Number Faces Lenght Lenght Htg. I Clg. Heating S-Clg L-Clg Heating I S-Clg I L-Clg r 6 all 12F-0sm n 7.13 0.93 1503 6722 878 63 449 59 oor Door,ovhd mti,pur n 4.11 1.18 560 2304 659 0 0 0 . Wall 12F-0sm w 7.13 0.93 1089 3906 510 567 335 44 —Door 11P0 w 20.88 5.97 21 438 125 0 0 0 11 —Door Door,ovhd mti,pur w 4.11 1.18 520 2139 612 520 2139 612 Ceil 18A-38md - 2.09 0.47 7801 16288 3642 441 921 206 Flor 22B-10tnm - 25.56 0.00 7801 4575 0 441 1789 0 d P�° Infiltration Heating Load(Btuh) 0.32 56942 13840 Effect WAR WAR 12 Sensible Load(Btuh) I ACH I 0.17 1.00 4201 0.24 1021 I I Latent Load(Btuh) I 6886 Internal a Occupants at 230 and 200 Btuh 30 6900 6000 0 0 0 b Scenario number 3400 0 13 c Default Adjustments d Custom Appliances 55000 0 0 0 e Plants 0 0 114 I Subtotals I Sum lines 6 through 12 I I 93315 75928 1288 6 19473 1942 115 I Ids I ELGEHLF 8 ESGF I OI OI 0 0 0 0 0 0 16 I Ventilation Loads Vent Cfm 0 E Cfm I 0 I I 0 0 0 I I I I I 117 I Winter Humidification Load Gal/Day I 0 I 0 I I I I I I 18 I Piping Load I 0 I 0 I I I 19 Blower Heat 120 AED Excursion&Latent Moisture Migration Load 0 0 21 Total Load Sum lines 13 through 19 93315 75928 12886 19473 1942 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -4'- wr+ghtsofr- 2022-Sep-07 09:06:29 ^am -•^^--.---•-- Right-Suite®Universal 2018 18.0.31 RSU24121 Page 1 Projectl.rup Calc=MJ8 Front Door faces: N Right-J8® Form J1 Job: Entire House Date: Sep 07,2022 - Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com 1 Name of Room Room2 2 Running Feet of Exposed Wall 109.0 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SqFt) 18.0 ft 6050.0 ft2 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 92.0 x 80.0 ft 7360.0 ft2 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 ° 7360.0 ft' Type of Const., r Panel HTM Area or I Btuh Area or I Btuh Exposure Number Faces Lenght Lenght Htg. Cig. Heating S-Clg L-Clg Heating I S-Clg L-Clg 6 all 12F-0sm n 7.13 0.93 1440 6273 819 L—poor Door,ovhd mtl,pur n 4.11 1.18 560 2304 659 . all 12F-Osm w 7.13 0.93 522 3571 466 oar 11P0 w 20.88 5.97 21 438 125 11 oor Door,ovhd mtl,pur w 4.11 1.18 0 0 0 Cell 18A-38md - 2.09 0.47 7360 15368 3436 Flor 22B-10tpm - 25.56 0.00 7360 2786 0 Infiltration Heating Load(Btuh) 0.32 43102 Effect WAR 12 Sensible Load(Btuh) I ACH I 0.17 0.76 3180 —I Latent Load(Btuh) I Internal a Occupants at 230 and 200 Btuh 30 6900 6000 b Scenario number 3400 13 c Default Adjustments d Custom Appliances 55000 0 e Plants 0 114 I Subtotals Sum lines 6 through 12 I I 73842 73986 I I I l 15 I LLoads EHLF 8 ESGF I OI Oil 0 0 o f I I I l 16 I Ventilation Loads Vent Cfm 0 E Cfm I 0 I I I I I I I I I 117 I Winter Humidification Load Gal/Day I 0 I I I I I I I oad 19 I Piping Blower Heat l l I l 20 AED Excursion&Latent Moisture Migration Load 0 21 Total Load Sum lines 13 through 19 73842 73986 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. — -41- wr+gtitsot f - 2022-Sep-07 09:06:29 -ram -•^-v-••---- Rig htSu fie®Universal201818.0.31 RSU24121 Paget Projectt.rup Cale=MJ8 Front Door faces: N Load Short Form Job. Date: Sep 07,2022 1.t:xu Entire House By: 4 ``1," Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thennalassociates.com Project Information For: Garvey Hyundai 257 Dix Ave.,Queensbury, NY 12804 Design Information Htg Clg Infiltration Outside db(°F) -2 85 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD(°F) 72 10 Fireplaces 0 Daily range - M Inside humidity(%) 50 50 Moisture difference(gr/Ib) 51 27 HEATING EQUIPMENT COOLING EQUIPMENT Make Sample Make Sample Trade SampCorp Trade SampCorp Model ACP120100 Cond ACP120100 AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 10 EER Heating input 0 Btuh Sensible cooling 84000 Btuh Heating output 0 Btuh Latent cooling 36000 Btuh Temperature rise 0 °F Total cooling 120000 Btuh Actual air flow 4000 cfm Actual air flow 4000 cfm Air flow factor 0.043 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Room4 441 19473 1942 835 102 Room2 7360 73842 73986 3165 3898 Entire House d 7801 93315 75928 4000 4000 Other equip loads 0 0 Equip.@ 0.90 RSM 68335 Latent cooling 12886 TOTALS I 7801 I 93315 I 81221 I 4000 I 4000 Bold/Italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t wrightSof`t- 2022-Sep-07 09:06:29 � •.....•..........-....,........, Right-suite®Universal 2018 18.0.31 RSU24121 Page 1 ACCA ProJectl.rup Calc=MJ8 Front Door faces: N Loads for Multiple Orientations Job: Date: Sep 07,2022 I Entire House By: 1tE:w! l iti{14rE5 Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@themialassociates.com Web:www.thermalassodates.com Project Information For: Garvey Hyundai 257 Dix Ave.,Queensbury, NY 12804 Design Conditions Location: • Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 75 Elevation: 335 ft Design TD(°F) 72 10 Latitude: 43°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.4 26.5 Drybulb(°F) -2 85 Infiltration: Daily range(°F) - 22 ( M ) Wet bulb(°F) - 71 Wind speed(mph) 15.0 7.5 Front Door North-.. Northeast East Southeast South Southwest West Northwest Sensible Load(Btuh) ;;;'.'68335 68335 68335 68335 68335 68335 68335 68335 Latent Load(Btuh) 12886 12886 12886 12886 12886 12886 12886 12886 Total Load(Btuh) ,::81221 81221 81221 81221 81221 81221 81221 81221 Heating AVF(cfm) -4000.. 4000 4000 4000 4000 4000 4000 4000 Cooling AVF(cfm) • 4000, 4000 4000 4000 4000 4000 4000 4000 Building Orientation Cooling Load 11111 :1111 :1111 .1111 N NE E g S SN W WV gtedicn Rat Cbrfaes Current Orientation: Front Door faces North Highest Cooling Load: Front Door faces North Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2022-Sep-07 09:06:29 � ..--...„ RightSuite®U niversal 2018 18.0.31 RSU24121 Page 1 ACCA Projectl.rup Cabo=MJ8 Front Door faces: N BuildingAnalysis Job: x Y Date: Sep 07,2022 Entire House By: 1.4 x`'s , Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com Pro'ect Information For: Garvey Hyundai 257 Dix Ave.,Queensbury,NY 12804 Desi•n Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 75 Elevation:. 335 ft Design TD(°F) 72 10 Latitude: 43°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.4 26.5 Dry bur b(°F) -2 85 Infiltration: Dailyrange(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btu h/ft2 Btuh %of load Walls 7.1 10628 11.4 NCI lk Glazing 0 0 0 r Doors 4.4 4882 5.2 Ceilings 2.1 16288 17.5 Floors 0.6 4575 4.9 Infiltration 22.0 56942 61.0 Gjli Ducts 0 0 Piping 0 0 Irfltration Humidification 0 0 Ventilation 0 0 Roos Adjustments 0 Total 93315 100.0 Coolin• Component Btu h/ft2 Btuh %of load Walls 0.9 1388 1.8 Cafirxs Cther Glazing 0 0 0 Irfltrati Doors 1.3 1397 1.8 Ceilings 0.5 3642 4.8 Floors 0 0 0 Infiltration 1.6 4201 5.5 Ducts 0 0 Ventilation 0 0 Internal gains 65300 86.0 Blower 0 0 Adjustments 0 \Irterrnl Gains Total 75928 100.0 Latent Cooling Load=12886 Btuh Overall U-value=0.028 Btuh/ft2°F WARNING:window to floor area ratio=0.0%-less than 5%. Bold/italic values have been manually overridden i- wrightsoft- 2022-Sep-07 09:06:29 �0+ Right-Suite®Universal 2018 18.0.31 RSU24121 Page 1 .9L - Projectl.rup Calc=MJ8 Front Door faces: N J1 Form - Worksheet A Job: Date: Sep 07,2022 Entire House By: rtrmai Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com Supporting Detail Project Name: Date: Sep 07,2022 Address: 257 Dix Ave., Queensbury, NY 12804 Phone: Job ID: Worksheet A Location and Design Conditions Weather Location: Glens Falls AP, NY, US Elevation= 335 Latitude= 43 Indoor Conditions, Heating: DB= 70°F RH= 50 % Indoor Conditions,Cooling: DB= 75°F RH= 50 % Table 1 Conditions 99% DB= -2 °F 1%DB= 85 °F Grains Difference= 27 gr/Ib Daily Range= M Design Temperature Differences HTD= 72 °F CTD= 10 °F Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wIrightsoft" 2022-Sep-07 09:06:29 RightSuite®Universal 2018 18.0.31 RSU24121 Page 1 ACCt ProJectl.rup Cabo=MJ8 Front Door faces: N • Component Constructions Job: Date: Sep 07,2022 1�, f Entire House By: Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com Pro'ect Information For: Garvey Hyundai 257 Dix Ave.,Queensbury, NY 12804 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 75 Elevation: 335 ft Design TD(°F) 72 10 Latitude: 43°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(grAb) 51.4 26.5 Drybulb(°F) -2 85 Infiltration: Dailyrange(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuhlft?'F ft'-'FBluh Btuh/ft' Btuh Btuhilt' Btuh Walls 12F-Osm:Frm wall,mtl ext,r-30 cav ins,5/8"gypsum board int fnsh, n 943 0.099 21.0 7.13 6722 0.93 878 2"x6"metal frm,24"o.c.stud w 548 0.099 21.0 7.13 3906 0.93 510 all 1491 0.099 21.0 7.13 10628 0.93 1388 Partitions (none) Windows (none) Doors Door,ovhd mtl,pur core type n 560 0.057 16.6 4.11 2304 1.18 659 w 520 0.057 16.6 4.11 2139 1.18 612 all 1080 0.057 16.6 4.11 4443 1.18 1271 11 P0:Door,mtl pur core type w 21 0.290 10.5 20.9 438 5.97 125 Ceilings 18A-38md:Rf/clg ceiling,mtl roof mat,frm cons,5/8"gypsum board int 7801 0.029 38.0 2.09 16288 0.47 3642 fish,12"thkns,r-38 cell ins Floors 22B-10tpm:Bg floor,heavy dry or light damp soil,on grade depth,r-10 179 0.355 10.0 25.6 4575 0 0 edge ins,tile flr fnsh wrightsoft" 2022-Sep-07 09:06:29 Right-Suite®Universal 2018 18.0.31 RSU24121 Page 1 ACON Projectl.rup Cala=MJ8 Front Door faces: N • • Project Summary Job: Date: Sep 07,2022 Entire House By: ' t' Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com Pro'ect Information For: Garvey Hyundai 257 Dix Ave.,Queensbury, NY 12804 Notes: Desi•n Information Weather: Glens Falls AP, NY,US Winter Design Conditions Summer Design Conditions Outside db -2 °F Outside db 85 °F Inside db 70 °F Inside db 75 °F Design TD 72 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 93315 Btuh Structure 75928 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 93315 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 68335 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 12886 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 7801 7801 Equipment latent load 12886 Btuh Volume(ft3) 136449 136449 Air changes/hour 0.32 0.17 Equipment Total Load(Sen+Lat) 81221 Btuh Equiv.AVF(cfm) 728 387 Req.total capacity at 0.70 SHR 8.1 ton Heating Equipment Summary Cooling Equipment Summary Make Sample Make Sample Trade SampCorp Trade SampCorp Model ACP120100 Cond ACP120100 AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 10 EER Heating input 0 Btuh Sensible cooling 84000 Btuh Heating output 0 Btuh Latent cooling 36000 Btuh Temperature rise 0 °F Total cooling 120000 Btuh Actual air flow 4000 cfm Actual air flow 4000 cfm Air flow factor 0.043 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Bold/Italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2022Sep-07 09:06:29 . -- •-T-. RightSuite®Universal 2018 18.0.31 RSU24121 Page 1 ACCA Projectl.rup Cabo=MJ8 Front Door faces: N AED Assessment Job: Date: Sep 07,2022 Entire House By: "A`` Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thennalassociates.com Web:www.thermalassociates.com Project Information For: Garvey Hyundai 257 Dix Ave.,Queensbury, NY 12804 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 75 Elevation: 335 ft Design TD(°F) 72 10 Latitude: 43°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 51.4 26.5 Drybulb(°F) -2 85 Infiltration: Dailyrange(°F) - 22 ( M ) Wet bulb(°F) - 71 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hxiiy Glazing Load too 90. 80. 701 600 501 401 30' 201 101 • 8 9 10 11 12 13 14 15 16 17 18 19 20 rerdDay Maximum hourly glazing load exceeds average by 0.0%. House has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 0 Btuh Bold/Italic values have been manually overridden wrightsoft'• 2022Sep-Sep 09:06:29 f�' RightSuite®U niv ersal 2018 18.0.31 RSU24121 Page 1 /1�� Projectl.rup Calc=MJ8 Front Door faces: N • • • Right-J® Worksheet Job: Entire House Date: Sep 07,2022 By: Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5560 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com 1 Room name Entire House Room4 2 Exposed wall 179.0 ft 70.0 ft 3 Room height 17.5 ft d 9.0 ft heat/cool 4 Room dimensions 63.0 x 7.0 ft 5 Room area 7801.0 ft' 441.0 ft' I Ty r Construction r U-value Or I HTM I Area (ft') Load I Area (ft') Load number (Btuh/ft-"F (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool I Gross I N/P/S Heat I Cool I Gross I NIP/S Heat I Cool I 6. Vy 12F-0sm 0.099 n 7.13 0.93 1503 943 6722 878 63 63 449 59 �p Door,ovhd mtl,pur 0.057 n 4.11 1.18 560 560 2304 659 0 0 0 0 . W 12F-0sm 0.099 w 7.13 0.93 1089 548 3906 510 567 47 335 44 —D 11 PO 0.290 w 20.88 5.97 21 21 438 125 0 0 0 0 11 —D Door,ovhd mtl,pur 0.057 w 4.11 1.18 520 520 2139 612 520 520 2139 612 C 18A-38md 0.029 - 2.09 0.47 7801 7801 16288 3642 441 441 921 206 F 22B-lotom 0.355 - 25.56 0.00 7801 179 4575 0 441 70 1789 0 0 6 I Envelope loss/gain I I I 363731 64271 I 56331 920I 12 a) Infiltration 56942 4201 13840 1021 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 30 6900 0 0 Appliances/other 58400 0 Subtotal(lines 6 to 13) 93315 75928 19473 1942 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 93315 75928 19473 1942 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 I I Air rel dl(cfm) I I I 94000I 74000I I I 198437351 1902I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -rid- wrigatso tft- 2022-Sep-07 09:06:30 �.�A ._.. RightSuite®Universal 2018 18.0.31 RSU24121 Page 1 Projectl.rup Calc=MJ8 Front Door faces: N Right-JO Worksheet Job: • ray Entire House Date: Sep 07,2022 By: Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com 1 Room name Room2 2 Exposed wall 109.0 ft 3 Room height 18.0 ft heat/cool 4 Room dimensions 92.0 x 80.0 ft 5 Room area 7360.0 ft' r I I • , Ty Construction U-value Or I HTM I Area (ft') Load I Area Load number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter Heat I Cool I Gross I NIP/S Heat I Cool I Gross I NIP/S Heat I Cool 6. Vy 12F-0sm 0.099 n 7.13 0.93 1440 880 6273 819 �p Door,ovhd mU,pur 0.057 n 4.11 1.18 560 560 2304 659 12F-0sm 0.099 w 7.13 0.93 522 501 3571 466 11P0 0.290 w 20.88 5.97 21 21 438 125 11 11 Door,ovhd mU,pur 0.057 w 4.11 1.18 0 0 0 0 C 18A-36md 0.029 - 2.09 0.47 7360 7360 15368 3436 F 22B-10tom 0.355 - 25.56 0.00 7360 109 2786 0 6 I c)AED excursion I I I I OI Envelop a loss/gain 30740 5506 12 a) Infiltration 43102 3180 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 30 6900 Appliances/other 58400 Subtotal(lines 6 to 13) 73842 73986 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 73842 73986 15 Duct loads -0% 0% 0 0 I I TAirt rel uime i o( I I I 73 65I 73898I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlgtitsoft- 2022-Sep-07 09:06:30 .-`=c """ --^-""••"-` Rig htSuite®Universal201818.0.31 RSU24121 Page ' � Projectl.rup Cale=MJ8 Front Door faces: N tie F.W.WEBB COMPANY SUBMITTAL DATA Order#: Date: 08/11/2022 Project: GARVEY HYUNDAI Project#: Submitter: Don Abbruzzese FW WEBB COMPANY-ALBANY 17 ERIE BLVD, ALBANY, New York 12204 • 518-490-7500 Fi LE PY Information is subject to change without notice.Check local codes. Printed 08/11/2022 Date 08/11/2022 Project Name %If* GARVEY HYUNDAI Project Number etivwEasCOMPANY Client/Purchaser Submittal Summary Page Qty Tag# Model#/Material# Description 1 BUSINESS 1 RC0471 Roof Curb-14" High, Flat, Uninsulated, Full Perimeter(Shipped OFFICE Knocked Down) 1 ENCLOSED ZJO90S18R2D1AAD1A2 7.5 Ton, Single Packaged R-410A Air Conditioner, High Efficiency, SERVICE Two Stage Cooling, 12.0 EER, 180 MBH Input Stainless Steel,Two DRIVE Stage Gas Heat, 208/230-3-60 • Dry Bulb Low Leak Economizer w/Barometric Relief and Power Exhaust and Hoods(Bottom or Horizontal End Return Only)with Economizer Fault Detection & Diagnostic(Meets ASHRAE 90.1- 2013, IECC 2015, California Title 24,AMCA 511). •3 HP High Static Belt Drive Blower •Standard 2"Throwaway Filters • IntelliSpeed control of the VFD based on stages of cooling (Provides Single Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10) •Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors. • Micro-Channel "all-aluminum"condenser coil, Copper tube/aluminum fin evaporator coil • Composite Drain Pan-Front Connection •Tool-free maintenance with features like hinged doors for all- access panels, slide-out blower and blower motor tray • Hot Gas Bypass 1 ENCLOSED 1RC0471 Roof Curb- 14" High, Flat, Uninsulated, Full Perimeter(Shipped SERVICE Knocked Down) DRIVE 1 WASH/ ZJO78S18P2D1AAA1A2 6.5 Ton, Single Packaged R-410A Air Conditioner, High Efficiency, DETAIL Two Stage Cooling, 11.8 EER, 180 MBH Input Stainless Steel,Two BAYS Stage Gas Heat, 208/230-3-60 • Dry Bulb Low Leak Economizer w/Barometric Relief and Power Exhaust and Hoods(Bottom or Horizontal End Return Only)with Economizer Fault Detection& Diagnostic(Meets ASHRAE 90.1- 2013, IECC 2015, California Title 24,AMCA 511). • 1.5 HP Standard Static Belt Drive Blower • Standard 2"Throwaway Filters • IntelliSpeed control of the VFD based on stages of cooling (Provides Single Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10) •Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors. • Micro-Channel"all-aluminum"condenser coil, Copper tube/aluminum fin evaporator coil Information is subject to change without notice.Check local codes. Printed 08/11/2022 Qty Tag# Model#/Material# Description •Composite Drain Pan-Front Connection •Tool-free maintenance with features like hinged doors for all- access panels, slide-out blower and blower motor tray Equipment start-up and commissioning by a factory trained technician is recommended. Contact your supplying distributor or sales representative for additional information &guidance. AWARNING:Cancer and Reproductive Harm-www.P65Wamings.ca.gov Information is subject to change without notice.Check local codes. Printed 08/11/2022 York® Sun TM Pro 3-12.5 Ton Page:4 al YORK® Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO90S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED System: ZJO90S18R2D1AAD1A2 SERVICE DRIVE Cooling Performance ___ Total gross capacity 99.6 MBH r� j r Sensible gross capacity 76.8 MBH ; ¢ajl � Total net capacity 93.6 MBH Sensible net capacity 70.8 MBH Efficiency(at ARI) 12.00 EER ji t I til. Integrated eff.(at ARI) 14.60 IEER [' ' ® I'• ' Ambient DB temp. 95.0 °F i r i I. '.lid'--� l N +' Entering DB temp. 84.1 °F I. , Entering WB temp. 70.0 °F l' I; , ` \ Leaving DB temp. 62.6 °F Leaving WB temp. 61.2 °F I' Leaving air temp dew point 60.40 °F .� Power input(w/o blower) 6.38 kW '�� Sound power 90 dB(A) Refrigerant :.•' Refrigerant type R-410A Sys1 7 lbs 12 oz Sys2 7 lbs 5 oz 7.5 Ton Gas Heating Performance • York Sun Pro units are manufactured at an ISO 9001 registered facility and Entering DB temp. 60 °F each rooftop is completely computer-run tested prior to shipment. Heating output capacity(Max) 144 MBH Unit Features Supply air 3300 CFM • Two Stage Cooling Heating input capacity(Max) 180 MBH Leaving DB temp. 100.4 °F • 180 MBH Input Stainless Steel,Two Stage Gas Heat Air temp.rise 40.4 °F • Full perimeter base rails with built in rigging capabilities SSE 80.0 % • Unit Cabinet Constructed of Powder Painted Steel,Certified At 750 Hours Stages 2 Salt Spray Test(ASTM B-117 Standards) Supply Air Blower Performance • Scroll Compressor[s] Supply air 3300 CFM • Dry Bulb Low Leak Economizer w/Barometric Relief and Power Exhaust and Ext.static pressure 0.6 IWG Hoods(Bottom or Horizontal End Return Only)with Economizer Fault Addl.Unit Losses(Options/Accessories) 0.02 IWG Detection&Diagnostic(Meets ASHRAE 90.1-2013,IECC 2015,California Blower speed 916 RPM Title 24,AMCA 511). Max BHP of Motor(including service factor) 3.45 HP 3 HP Duct location Bottom High Static Belt Drive Blower Motor rating 3.00 HP • Solid Core Liquid Line Filter Driers Actual required BHP 1.88 HP • Unit Ships with 2"Throwaway Filters Power input 1.75 kW • Replacement Filters:4-(24"x 20").Unit accepts 2"or 4"wide filters. Elevation 0 ft. • Short Circuit Current:5kA RMS Symmetrical Drive type BELT Outside/Mixed Air • Single Point Power Connection Outside Air Cfm 1500 CFM • Through-the-Curb and Through-the-Base Utility Connections Outside Air DB temp. 95 °F • Micro-Channel"all-aluminum"condenser coil,Copper tube/aluminum fin Outsided Air WB temp. 78 °F evaporator coil Outside Air RH 47.3 % • Composite Drain Pan-Front Connection Return Air CFM 1800 CFM • Tool-free maintenance with features like hinged doors for all-access panels, Return Air DB temp. 75 °F slide-out blower and blower motor tray Return Air WB temp. 62 °F Return Air RH 48.1 % • Hot Gas Bypass Electrical Data BAS Controller Power supply 208-3-60 • IntelliSpeed control of the VFD based on stages of cooling.Provides Single Unit min circuit ampacity 51.3 Amps Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10. Unit max over-current protection 60 Amps • Smart Equipment Controller including Discharge Air,Return Air,and Outdoor Dimensions&Weight Air Temperature Sensors. Hgt 51 in. Len 89 in. Wth 59 in. Standard Unit Controller: Smart Equipment Control Board Weight with factory installed options 1305 lbs. • Safety Monitoring-Monitors the High and Low-Pressure Switches,the Clearances Freezestats,the Gas Valve,if Applicable,and the Temperature Limit Switch Right 12 in. Front 36 in. Rear 36 in. on Gas and Electric Heat Units.The Unit Control Board will Alarm on Ignition Top 72 in. Bottom 0 in. Left 36 in. Failures,Safety Lockouts and Repeated Limit Switch Trips. Note: Please refer to the tech guide for listed maximum static pressures Warranty • One(1)Year Limited Warranty on the Complete Unit ru' 'CERTIFIED„WAFT?=G.r1\ ' )� 0 • Five(5)Year Warranty-Compressors and Electric Heater Elements ...,�,a..b.,o„ CO WA i `rus®. = ,A, • Fifteen(15)Year Limited Warranty-Stainless Steel Heat Exchanger Information is subject to change without notice.Check local codes. Printed 08/11/2022 York® SunTM Pro 3-12.5 Ton Page:5 YORK Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO90S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED System: ZJO90S18R2D1AAD1A2 SERVICE DRIVE Additional Electrical Data Power supply 208-3-60 Unit min circuit ampacity 51.3 Amps Unit max over-current protection 60 Amps Min Voltage 187 V Max Voltage 252 V Comp#1 RLA 13.6 Comp#1 LRA 83.1 Comp#2 RLA 13.6 Comp#2 LRA 83.1 Indoor Mtr Voltage 208-3-60 Indoor Mtr FLA 9.6 Outdoor Mtr Qty 2 Outdoor Fan Voltage 208-1-60 OD Fan Mtr FLA(ea.) 2.8 Power Ex Mtr Qty 1 Powered Ex Voltage 208-1-60 Power Ex Mtr FLA(ea) 5.5 York® Sun TM Pro 3-12.5 Ton Page:6 PORK Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO90S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED System: ZJO90S18R2D1AAD1A2 SERVICE DRIVE Factory Installed Options ZJO90S18R2D1AAD1A2 Equipment Options Option(s) Selected Single Packaged R-410A Air Conditioner, High Product Category: ZJ Efficiency 12.0 EER 7.5 Ton Nominal Cooling Capacity: 09u Two Stage Cooling Heat Type and Nominal Heat Capacity: S18 180 MBH Input Stainless Steel,Two Stage Gas Heat 3 HP High Static Belt Drive Blower IntelliSpeed control of the VFD based on stages of Blower Option: R cooling(Provides Single Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10) Voltage: 2 208/230-3-60 Dry Bulb Low Leak Economizer w/Barometric Relief and Power Exhaust and Hoods(Bottom or Horizontal End Outside Air Option: D Return Only)with Economizer Fault Detection& Diagnostic(Meets ASHRAE 90.1-2013, IECC 2015, California Title 24,AMCA 511). Service Options: 1 1 Sensor Options: A I n Smart Equipment Controller including Discharge Air, Controls: A Return Air,and Outdoor Air Temperature Sensors. Micro-Channel"all-aluminum"condenser coil,Copper Refrigeration: D tube/aluminum fin evaporator coil Standard 2"Throwaway Filters Additional Options: 1 Hot Gas Bypass Composite Drain Pan-Front Connection Tool-free maintenance with features like hinged doors for Cabinet Options: A all-access panels,slide-out blower and blower motor tray Product Generation: 2 Field Installed Accessories O 1 BD0408-Burglar Bars (32.0 Ibs) 0 1 CV0413-Concentric 0 1 FL0402-Permanent 2"only O 1CG0420-Coil Guard (27.0 lbs) Diffuser,Side Discharge,18X28 Filter Kit(Includes (4) Four Filters) O 1CV0403-Concentric 0 1CV0420-Concentric (2.2 Ibs) Diffuser,Flush Mount,20RD Diffuser,Specialty,24X24 0 1 HG0411 -Hail Guard Kit- O 1 CV0404-Concentric 0 1 FE0412-Flue Exhaust Diamond Pattern (37.0 Ibs) Diffuser,Flush Mount,18X28 Extension Kit(14.0 lbs) 0 1HG0432-Hail Guard Kit- O 1CV0412-Concentric 0 1FF0414-2"Only Metal Filter Provent Style (25.0 Ibs) Diffuser,Side Discharge,20RD Frame Kit(16.0 Ibs) Information is subject to change without notice.Check local codes. Printed 08/11/2022 York® Sun TM Pro 3-12.5 Ton Page:7 rial YORK Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO90S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED System: ZJO90S18R2D1AAD1A2 SERVICE DRIVE O 1 RC0470-Roof Curb-8" High, 0 S1-ADDWIRE-Add-a-Wire allows 0 S1-NSB8BHN240-0-Wall Flat, Uninsulated, Full Perimeter 5-wire thermostats to use only 4 Temperature and 3% Relative (Shipped Knocked Down)(135.0 wires. (0.3 Ibs) Humidity Combined Sensor, Full Ibs) 0 S1-CTSDTS-CTS Wired Display,WHITE, JCI LOGO, • 1 RC0471 -Roof Curb- 14" High, Temperature Sensor for NS8000 Series(0.4 Ibs) Flat, Uninsulated, Full Perimeter thermostat I Duct*Also works for 0 S1-NSB8BHN241-0-Wall (Shipped Knocked Down)(135.0 LX Series(0.3 Ibs) Temperature and 3% Relative Ibs) 0 S1-CTSHTS-CTS Hardwired Humidity Combined Sensor, Full O 1 RC0472-Roof Curb,Transition- Temperature Sensor for CTS Display,WHITE, NO JCI LOGO, Sunline 7.5T thru 12.5T to Pro Thermostats*Works with LX NS8000 Series(0.4 Ibs) 3.0T thru 12.5T(Shipped series as well(0.2 Ibs) 0 S1-NSB8BHN243-0-Wall Assembled)(200.0 Ibs) 0 S1-CTSPLATE-Wall Plate for Temperature and 3% Relative O 1 RC0476-Roof Curb-24" High, CTS Thermostats*Also works for Humidity Combined Sensor, Full Flat, Uninsulated, Full Perimeter new platform LX series models Display, BLACK, NO JCI LOGO, (Shipped Knocked Down)(135.0 below(0.0 Ibs) NS8000 Series(0.4 Ibs) Ibs) 0 S1-CTSWFTS-CTS Temperature 0 S1-NSB8BPN240-0-Wall O 1WC0412-Wooden Crate (445.0 Sensor with WiFi for CTS Temperature and 2% Relative Ibs) Thermostats*Also works with LX Humidity Combined Sensor, Full O 2AP0402-Air Proving Switch (1.0 Series (0.1 Ibs) Display,WHITE, JCI LOGO, Ibs) 0 S1-LXLOCK-Locking Ring For NS8000 Series(0.4 Ibs) O 2AQ04700524-CO2 Space LX-Series Thermostats(0.4 Ibs) 0 S1-NSB8BPN241-0-Wall Sensor-Wall Mount Accessory 0 S1-LXPLATE-Wall Plate For LX- Temperature and 2% Relative (5.0 Ibs) Series Thermostats (0.0 lbs) Humidity Combined Sensor, Full O 2AQ04700624-CO2 Unit Mount 0 S1-LXWFM- For LX Series Display,WHITE, NO JCI LOGO, Accessory(4.6 Ibs) Thermostats-WiFi NS8000 Series(0.4 Ibs) O 2DF0403-Dirty Filter Switch (1.0 Communication (0.1 Ibs) 0 S1-NSB8BPN243-0-Wall Ibs) 0 S1-MP-PRTKIT-OP-MAP Temperature and 2% Relative O 2EC0401 -Kit, Single Enthalpy (Multiple Access Portal) Gateway Humidity Combined Sensor, Full Field Installed (1.0 Ibs) Kit-Replacement MAP gateway Display, BLACK, NO JCI LOGO, O 2EC0402-Kit, Dual Enthalpy protective case, lanyard and NS8000 Series(0.4 lbs) Field Installed (Includes two communication cable. Use only to 0 S1-NSB8BTN041-0-Wall humidity sensors)(1.0 Ibs) replace worn or damaged Temperature Sensor, No Display, O 2LA04702412-Low Ambient Kit- components. (0.3 Ibs) WHITE, NO JCI LOGO, NS8000 ICM 333 (2.2 lbs) 0 S1-NSB8BHN041-0-Wall Series (0.4 Ibs) O 2SD04700824-Smoke Detector Temperature and 3% Relative 0 S1-NSB8BTN043-0-Wall Kit w/Mounting Hardware for Humidity Combined Sensor, No Temperature Sensor, No Display, Supply Air(Horizontal/Downflow) Display,WHITE, NO JCI LOGO, BLACK, NO JCI LOGO, NS8000 Only(9.4 Ibs) NS8000 Series(0.4 Ibs) Series(0.4 Ibs) O 2SD04700924-Smoke Detector 0 S1-NSB8BHN043-0-Wall 0 S1-NSB8BTN141-0-Wall Kit w/Mounting Hardware for Temperature and 3% Relative Temperature Sensor, Return Air(Downflow Only)Only Humidity Combined Sensor, No Warmer/Cooler Display,WHITE, (10.0 Ibs) Display, BLACK, NO JCI LOGO, NO JCI LOGO, NS8000 Series O 2SD04701024-Smoke Detector NS8000 Series (0.4 Ibs) (0.4 Ibs) Kit w/Mounting Hardware for 0 S1-NSB8BHN141-0-Wall 0 S1-NSB8BTN143-0-Wall Supply(Horizontal/Downflow)and Temperature and 3% Relative Temperature Sensor, Return Air(Downflow Only)(8.0 HumidityCombined Sensor, Warmer/Cooler Display, BLACK, Ibs) Warmer/Cooler Display,WHITE, NO JCI LOGO, NS8000 Series O S1-03102529000- Non- NO JCI LOGO, NS8000 Series (0.4 lbs) Networking Wall Sensor-Allows (0.4 Ibs) 0 S1-NSB8BTN240-0-Wall remote sensing and control from 0 S1-NSB8BHN143-0-Wall Temperature Sensor, Full Display, single or multiple zones. (0.2 Ibs) Temperature and 3% Relative WHITE, JCI LOGO, NS8000 O S1-03102529004-Non- Humidity Combined Sensor, Series(0.4 Ibs) Networking Wall Sensor with Warmer/Cooler Display, BLACK, 0 S1-NSB8BTN241-0-Wall Over-ride button-Allows remote NO JCI LOGO, NS8000 Series Temperature Sensor, Full Display, sensing and control from single or (0.4 Ibs) WHITE, NO JCI LOGO, NS8000 multiple zones. Override allows Series(0.4 Ibs) setpoint to be overridden for 2 hour time period. (0.2 Ibs) Information is subject to change without notice.Check local codes. Printed 08/11/2022 YORKYork® Sun TM Pro 3-12.5 Ton Package Page:8 Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO90S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED System: ZJO90S18R2D1AAD1A2 SERVICE DRIVE O S1-NSB8BTN243-0-Wall 0 S1-TEC3631-14-000-7 DAY Temperature Sensor, Full Display, PROGRAMMABLE BLACK, NO JCI LOGO, NS8000 THERMOSTAT, OPTIONAL MSTP Series(0.4 Ibs) OR N2 COMMUNICATION, O S1-SE-COM1001-0-Field RTU/HEAT PUMP WITH ECON, Installed Communication Card for OCC SENSOR, FULL COLOR, Simplicity SE control. Can be field WHITE, JCI LOGO(0.8 Ibs) configurable for BACnet, N2 or 0 S1-TEC3631-16-000-7 DAY ModBUS MSTP (0.0 Ibs) PROGRAMMABLE O S1-TBSU305-Y-York Branded LX THERMOSTAT, OPTIONAL MSTP Series I 3" LCD Display 13/4 OR N2 COMMUNICATION, Stage Heating 12 Stage Cooling I RTU/HEAT PUMP WITH ECON, (5+1+1)7-day Programmable (1.0 OCC SENSOR, FULL COLOR, Ibs) WHITE, NO LOGO(0.8 Ibs) O S1-TEC3030-14-000-7 DAY 0 S1-YK/AN-RSO-ACI -Non- PROGRAMMABLE Networking Wall Sensor with THERMOSTAT, ZIGBEE PRO Setpoint Adjustment and Over-ride WIRELESS COMMUNICATION, Button—Allows remote sensing RTU/HEAT PUMP WITH and control from single or multiple ECON,FULL COLOR,WHITE, JCI zones. (1.0 Ibs) LOGO (0.8 Ibs) 0 S1-YK-MAP1810-0P-MAP O S1-TEC3030-16-000-7 DAY (Multiple Access Portal) Gateway- PROGRAMMABLE For use with SimplicitySE Control. THERMOSTAT,ZIGBEE PRO (0.2 Ibs) WIRELESS COMMUNICATION, 0 S1-YK-MAP1810-0S-Stationary RTU/HEAT PUMP WITH ECON, MAP Gateway(Includes MAP AND FULL COLOR,WHITE, NO Gateway, Field Bus Adapter, LOGO (0.8 Ibs) Mounting Bracket and 100 to 240 O S1-TEC3031-14-000-7 DAY VAC Power Supply). US- PROGRAMMABLE compatible counties. (1.9 Ibs) THERMOSTAT, ZIGBEE PRO WIRELESS COMMUNICATION, RTU/HEAT PUMP WITH ECON, OCC SENSOR, FULL COLOR, WHITE, JCI LOGO (0.8 Ibs) O S1-TEC3031-16-000-7 DAY PROGRAMMABLE THERMOSTAT,ZIGBEE PRO WIRELESS COMMUNICATION, RTU/HEAT PUMP WITH ECON, OCC SENSOR, FULL COLOR, WHITE, NO LOGO (0.8 Ibs) O S1-TEC3630-14-000-7 DAY PROGRAMMABLE THERMOSTAT, OPTIONAL MSTP OR N2 COMMUNICATION, RTU/HEAT PUMP WITH ECON,FULL COLOR,WHITE, JCI LOGO (0.8 Ibs) O S1-TEC3630-16-000-7 DAY PROGRAMMABLE THERMOSTAT, OPTIONAL MSTP OR N2 COMMUNICATION, RTU/HEAT PUMP WITH ECON,FULL COLOR, WHITE, NO LOGO (0.8 Ibs) Information is subject to change without notice.Check local codes. Printed 08/11/2022 gigiyoRK® York® Sun TM Pro 3-12.5 Ton Package Page:9 Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJ090S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED SERVICE DRIVE Consolidated Drawing 1 2 3 4 5 6 7 8 9 10 II 12 13 14 I5 I NOTES: OPERATING CENTER OF GRAVITY I. FOR OUTDOOR USE ONLY, TONNAGE UNIT WEIGHT D(NIT� LOCATION(BASE UNIT) 4 POINT CORNER LOADS IL05)10A5E UNIT) (BASN 2. WEIGHTS SHOWN ARE FOR COOLING ONLY UNITS. ~—32.67 6.5 IB/IN 030(4611 4011 1 0161 2516351 111112456 91[891 262 11191 327 11481 3. MIN. CLEARANCES TO BE: [829.81 1.5 20/111 080(4901 39 1990,61 24(609.61 245 11111 89(86) 281 11281 365 11661 N RIGHT SIDE: 12 [3051 07 8.5 28/24 084 14921 38 1965,21 24 1609,61 255 11161 90 I801 214 11;11 381 (1611 LEFT SIDE: 36 [9151 6.83 II IeaN 085 1A921 39(990,61 zs 163s1 257 1117] 99 1901 274 11241 355 11611 FRONT: 36 [915] [113.5]~ 810 IF/25.5 /FM0103 15011 38 1965,21 24(609,61 251 11171 92(811 279 11271 315 11101 REAR: 36 [9151 P4.38 8.5 GAITS 030 14671 38(965,21 24 1609,61 240(1091 79(811 261 [net 350(1591 TOP: 72 [18301 [619 2] + 1 10 IN/ZU 090 14941 38(965,21 24(609,61 254(1151 89 1861 , 276 11251 371 11681 BOTTOM: 0 [O1 6.5 23(08 030(167] 39 1990,61 25[6351 2/5)III] 91 [81) 260 11181 333 1(511 3 4. TO REMOVE THE SLIDE-OUT DRAIN PAN, A REAR CLEARANCE OF V - 8 8,5 u/7W os0(176] 39(990.61 25 16351 _ 250 11131 84(841 265/1201 3/0 n5/1 8.5 ZJ/ZW 060 l/811 38[965,21 24[609.61 217[112] 84 1841 168 71221 360(163/ 3 60 in (1525 IS REQUIRED. IF SPACE IS UNAVAILABLE, THE 10 2J/2e 070 14851 39 1990,61 24[609,61 245(1111 91 [871 278 11261 357 11621 DRAIN PAN CANN H BE REMOVED THROUGH THE FRONT BY SEPARATING —MOO 7.84 8.5 X II 2AnR 200(5441 38 1965,21 25.5 1641,71 297 11351 221 (1001 291 (1321 350 Inn THE CORNER WALL. [457,2] [199,.1] 6,5 %P196 080(4901 38 1$65,21 25(6351 262(1191 95(891 266 1121] 357 11621 5. FOR SMALLER SERVICE AND OPERATIONAL CLEARANCES r6.75 7.5 %P/IA 090 14941 38 1965,21 23(584,21 243 11101 81 (821 284(1291 361 (1731 CONTACT YOUR APPLICATION ENGINEERING DEPARTMENT. 32.06 - I [171,61 8.5 %P/%A 137(5161 38 1965,21 25,5 1647,71 282 1128] 210 1951 276(1251 3/0 1168) 6, DOWNFLOW DUCTS DESIGNED TO BE ATTACHED TO ACCESSORY [814 4] + 10 %P/%A 135[5151 38[965,21 25.5 1647,71 281 [1211 209 1951 275 1125) 369 1161) T. SIDER DUCT FLANGES ARE ON7A" EISO. [FROM MTB. • A ' A IU B ALTERNATE CONDENSATION DRAIN 0.50 18.25 N H ROOF CURB ONLY. IF UNIT IS MOUNTED SIDE SUPPLY, IT • �.-,. I IS RECOMMENDED THAT THE DUCTS ARE SUPPORTED BY - J 24.2461 IN CROSS BRACES, AS DONE ON ACCESSORY ROOF CURBS. [615,6] 'R [ S ["�,,�411 G,1 [266,7] �� [463,6] BOTTOM DUCTS DO NOT HAVE FLANGES. FLANGE) T P 24.00 lam • 3�i _ o —�� 8. MINIMUM CONDENSATION TRAP HEIGHT SHALL BE 1.5 TIMES 27.50 P s f �` 2:= THE LOWEST NEGATIVE STATIC. t 'R(698,51 L [609,6] \ ' j/ -s�E T 9, DIMENSIONS IN [ 1 ARE IN MILLIMETERS OR KILOGRAMS, :II T \�...� RIGHT =_ a G 10. OPTIONAL COIL GUARDS, POWER EXHAUST, GAS HEAT, LEFT i -4g57G ECONOMIZER, DISCONNECT SWITCH, CONVENIENCE OUTLET, � J 18.25 � [219,26] AND BAROMETRIC RELIEF AND FRESH AIR HOODS SHOWN. f } ,51 „"�lk+('�%DI [463,61 �__aT R 20.39 1 I 21.00 I +,�,+61, 111E1 =�!�� N ©'EXCEPT %P/XA (HEAT PUMP) UNITS. 19.14 y [533,41 !• e d [518,0] 20.14 11.14 I. °Mfg" _' II [511,61 [486,2] [435,4] 1 CJ II® 18,06 DIRECTION OF AIRFLOW 1 + ii 3_ Q 1 F__ [458,1) F S CENTER OF GRAVITY 14.47 �• FRONT •OT OM GAS gym.____I_ F [367,6] 6.39�OTTOM ENTRY: SUPPLY ENTRY 02.00 [50,8] 5.16 [^2,88 18.06 - I [416,41 POWER 952,50 [63,51 [I31,1] 28.25 31.63 --•{ [73,2] [458,81 - 18.89 CONTROL 30 00.875 [22,231 [717,61 [803,41 OUTSIDE A I R X [479,9] 7I1�1�1. �W(PARTIAL VIEW) E INTAKE HOOD DISCONNECT SWITCH COVER (INTAKE HOOD NOT SHOWN IN THIS VIEW) E 8 (OPTIONAL) (OPTIONAL) I L [2239 I2239,9] -•I POWER ENTRY 962.50 (63,5) lit —" ' ---• ----i .( r I11415,51� AS INLET A -�- - - --• I653,31 1_ FRESH AIR HOOD! BLOWER ACCESS !:, 25.72 I I nll ECONOMIZER P1 I. [COMPREHOR.. CTL PANEL/ (OPTIONAL) FILTER/ --D • COMPRESSOR, 7 D • I CONTROL ENTRY 00.875[22,23/ ACCESS ACCE ==— _ • - _ •. •: ',. POWER ENTRY G42,50 (63,51 �;• _ _ n. "" Imo--,__ I BAROMETRIC RELIEF HOOD/ II I-���• .��• - I1289,I1 N - -"-- __�, POWER EXHAUST A66, I I_ � � C 12� (OPTIONAL/ , ,Ba l� -- — ----- - C CONVENIENCE OUTLET COVE' „__a.,_, - "- !EFT VIEW (OPTIONAL/ ^--27,31 21.19 --- 11.38 - _ [693,71 SEE DETAIL A FOR [538,2] [289,1] Poo. • ; oa} CONVENIENCE OUTLET DRAIN LOCATION EXHAUST © I-. 59.00 POWER ENTRY 00.815(22.231 FLUE [1498,6] 3/4° FPT 89.00 - OIL GUARD B [2260,61 FT40NT IEW RIGHT VIEW (OPTIONAL) B (OPTIONAL FRONT COIL GUARD NOT SHOWN IN THIS VIEW) A ft 4TEH DATE REVISION RECORD EC N0 DR CR Be TAINT AMC PROJECTION AMP+OP+¢ixn Mlaxrs a Ix[4U0ncr wATru [[OF+A4[An av[P A+P 113,111r11 141101 O SAFETY AND N[Y lCY If 4AAMTEe r0 ACPADPMCI TN13 P41Mr II PTOIE Cl PAA7 0A el4CAe5[ SAAEpACT[[RI6XIC.N PEA A 02-I1-20 NEW DRAWING (FROM UST-PRED-F SON) 75168 LOP RCH SAA ur0101104 UPOM I7 TO 01xa4.VIT0OUT VEITT[M QM.el 109M10e COMIAOLM BE•POP-fTD-OI 5,37 J�\ ORAWI16 PER ASYE 114.3.2000 MATERIAL (136,41 �J r IWI.u[111MIMEMIMI: SUBMITTAL DWG, PRO TYPE NOT APPLICABLE A MT OHPMOECI4A[: 9:.I 512E A DIN 1.IUWO 12.11.21 193/Ma0)0186l: 3.91 STD FLAT COIL, 50" CAB IAGIPIE NOT APPLICABLE ONG NO. ono I.AAOW 12.11•21 MAMEIPIACID1CI4AE: 2.010 JOHNSON CONTROLS 5883785 REV SC AEEA..0.A ENG E.AM12.1141 Mtn f Y UNITARY PRODUCTS GROUP A SMFG CALE OIME65101A AMt IA IKMt3 PART NO. SCALE 0,01S (0+ol sat[FewNORNAN,ON 73069 SA1 N0 10r I . I 2 3 4 5 6 7 8 9 10 II 12 13 (4 15 16 Information is subject to change without notice.Check local codes. Printed 08/11/2022 2 YORK® York® Sun TM Pro 3-12.5 Ton Page:10 Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO90S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED SERVICE DRIVE Component Locations Cooling With Gas Heat(6.5 Through 10 Tons) Smart Equipment'm control board Filter drier Disconnect location Filter access w/screw connector for T-stat (solid core) optional disconnect switch) (2"or 4"filter options) wiring and network connections ( P Terminal block for Micro-Channel Aluminum hi-voltage connection _�" .- Tube/Aluminum Fin 'fie J , J Condenser model �' `. nameplate = inside hinged - ��!�--l Slide-out motor and , ,� blower assembly for access panel /' I"\,__,- Second /� easy adjustment - and service Dual stage i Belt-drive cooling for I, % T'.maximum '' \ ._' V . blower motor comfort !. tom " ,, ,,- I F i�` : VFD location(optional) '�� ��� ' "�); J �e Power ventor motor Compressor#2 u, !' ram',j. iA �_ ; access(high- I ,:• ,• ,; ;Rill'' '���"rA'► ( 9 J- 20-gauge aluminized efficiency ' ��` •s t Y .� , p ! r'. •steel tubular heat compressor) I f • a l.l.i 2 p&a t _j�• exchanger for long life 13 i I� (stainless steel option) /'� ,- 1 Two-stage gas Base rails w/forklift { I j N heating to maintain ' slots(three sides) �'- "i warm,comfortable Slide-out drain pan and lifting holes i _ /` temperature \� =l1__ / with 1"NPT, Roof curbs in eight-and /j female connection Intelligent control fourteen-inch heights.Roof�� l board for safe and curbs for transitioning from efficient operation York Sunlinev"footprint to Side entry power Compressor#1 access the ZH/ZJ/ZR/ZU/ZW/ZK Toolless and control wiring (high-efficiency compressor) Series footprints door latch knockouts are also available(field installed accessory) Information is subject to change without notice.Check local codes. Printed 08/11/2022 iiiiiYORK® York® Sun TM Pro 3-12.5 Ton Page:11 Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO90S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED SERVICE DRIVE Low Leak Downflow Economizer Low Leak Downflow Economizer(shown with optional Power Exhaust) � Olttitvr., �'' l ,��a,. �_ Fresh Air Hood ���\0� ' 'I''it (included) Ilirrir---...*:-.-ii:-...s---',,,,,,,,,, / 1.11-1---1 -00 _111.11w:- --1—..-- ,..._ •!--.1-1-I'l-i _ Arii �"� 1 tl lIli t111 ill .'... =-1-7i___-_--1 I FVw, 1 - = `J ; '' gATw i I 'ice i — r ►ar4r 4 0,010-0-01-1 Low Leak Economizer(included) Power Exhaust(optional) Barometric Relief Damper Barometric Relief (included) Hood (included) Low leak economizers are capable achieving low leakage rates of 3 cfm/sq. ft at 1"of static pressure, meeting or exceeding the following standards: ASHRAE 90.1-2010 ASHRAE 62 AMCA 511 (licensed as Class 1 A damper) International Energy Conservation Code (IECC) California Title 24 The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit.Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. Information is subject to change without notice.Check local codes. Printed 08/11/2022 York® Sun TM Pro 3-12.5 Ton Page:12 yoRK® Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO90S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED SERVICE DRIVE Factory Installed Power Exhaust SP-in:wg. o o 0 0 0 0 0 0 0 0 o W -A in 01 4 O (O O 0 0 0 0 0 O 0 0 0 CA _ 0 N 0 . 0 0 N O O 0 w 01 ni F+ O 3 O = x • CI 0 M CCy et w cn 0 0 5 v 0 0 0 o . 0 0 0 0 0 o w b� io 0 0 0 0 BHP Information is subject to change without notice.Check local codes. Printed 08/11/2022 YORK® York® Sun TM Pro 3-12.5 Ton Page:13 Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO90S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED SERVICE DRIVE Seismic Certification l OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT ' FACILITIES DEVELOPMENT DIVISION i ----- — - --- ------ 1 APPLICATION FOR OSHPD SPECIAL SEISMIC -- OFFICE USE ONLY -- [CERTIFICATION PREAPPROVAL (OSP) APPLICATION#: OSP—0213 i OSHPD Special Seismic Certification Preapproval (OSP) Type: ❑ New ® Renewal ---- ----- -- --- --------- --- -- - ------------ L Manufacturer Information Manufacturer: Johnson Controls Inc.(JCI) Manufacturer's Technical Representative: Cameron Boyce,Engineer II Mailing Address: 5005 Interstate Drive,Norman,OK,73069 Telephone: (405)419-6830 _ r,,QEma`il: d cameron.w.boyceaici.com , Product Information ,�i .4 Product Name: Predator Rooftop Air.Conditioning_Units 1 ! J ) '?_ Product Type: Packaged Air Conditioning Units C S P-f 71:1 Product Model Number: See attached 1 (List all unique product identification numbers and/or part-nurnbers))oth ef N i a n d The units are enclosures withthe following subcomponents:refrigerant compressors,outdoor General Description: fan motors,indoor coils,outdoor coils,reversing valve with coil,thermostatic expansion valves, standard indoor blower motor,Variable frequency dr ve` ndobr blower motor,exhaust fan motor,variable frequency drive,economizer,electric heater,heat cells,filters,and other miscellaneous items included in the subcomponent tables. .._ .;-,r1 (`, r/ f1rv1. ri'-) Mounting Description: Units are rigid'curb and isolated curb.base mounted . r >Y c s. Applicant Information — -- --- t,`I &UIL-Dsl � �''�= -- —-- — ----� Applicant Company Name: The VMC Group Contact Person: John Giuliano Mailing Address: 113 Main Street,Bloomingdale,NJ 07403 Telephone: (973)838-1780 Email: john.giulianoQthevmcgroup.com I hereby agree to reimburse the Office of Statewide Health Planning and Development review fees in accordance with the California Administrative Code, 2016. Signature of Applicant: �� ,o,_ Date: 8/28/19 Title: President Company Name: The VMC Group { "Access to Safe,Quality Healthcare Environments that Meet California's Diverse i j�Ip��`�� OSHPD STATE OF CALIFORNIA—HEALTH AND HUMAN SERVICES AGENCY 1111{y OSH-FD-759(REV 12/16/15) Page 1 of 3 Information is subject to change without notice.Check local codes. Printed 08/11/2022 al YORK® York® Sun TM Pro 3-12.5 Ton Page:14 Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO90S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED . SERVICE DRIVE Seismic Certification ,_ OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT iYI�1'` FACILITIES DEVELOPMENT DIVISION rCalifomia Licensed Structural Engineer Responsible for the Engineering and Test Report(s) J Company Name: The VMC Group Name: Kenneth Tarlow California License Number: SE-2851 Mailing Address: 113 Main Street,Bloomingdale,NJ 07403 Telephone: (973)838-1780 Email: _ken.tarlowt thevmcgroup.com. 1 Supports and Attachments Preapproval ❑ Supports and attachments are preapproved under OPM- (Separate application for OSHPD Preapproval of Manufacturer'sCODE 's Certification(OPM)of Supports and attachments is required) ® Supports and attachments are not preapproved '^ yyyy yy i\ti v09d/.'. Certification Method 7, am'al d d L /j ® Testing in accordance with: ,lk ICC-ES AC156 ❑ Other(Please Specify): 4 O S P-0213 --iA BY:Timothy J Piland , [Testing Laboratory _DATE_O3/Q$/2021 _ ___ — Company Name: DCL Labs ca „<1 Contact Name: Josh Sailer,Laboratory-Manager 2k' 1 3 _<.-.•v Mailing Address: 1315 Greg Street,Suite 109/Sparks,NV 89431',C `-'t</ILUt+''- Telephone: (775)358-5085 - Email: joshashaketest.com "Access to Safe,Quality Healthcare Environments that Meet California's Diverse liit\1+l OSHPD STATE OF CALIFORNIA—HEALTH AND HUMAN SERVICES AGENCY 'j II OSH-FD-759(REV 12/16/15) Page 2 of 3 Information is subject to change without notice.Check local codes. Printed 08/11/2022 YORK® York® Sun TM Pro 3-12.5 Ton Page:15 Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO90S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED SERVICE DRIVE Seismic Certification OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT /ff, ��+` FACILITIES DEVELOPMENT DIVISION p Seismic Parameters Design in accordance with ASCE 7-16 Chapter 13: ®Yes ❑No Design Basis of Equipment or Components(FpNVp)= Rigid Curb=1.5;Spring Isolated Curb=4.5 Sos(Design spectral response acceleration at short period,g)= 2.00 ap(In-structure equipment or component amplification factor)= 2.5 Rp(Equipment or component response modification factor)= Rigid Curb=6.0;Spring Isolated Curb=2.0 no(System overstrength factor)= 2.0 I,(Importance factor)=1.5 z/h(Height factor ratio)= 1 Equipment or Component Natural Frequencies(Hz)= See attachment Overall dimensions and weight(or range thereof).. See attachment 0F, UOUE �n Equipment or Components @ grade designed"jn accordance with ASCEjT,A16 Chapter 15: ❑Yes E No Design Basis of Equipment or Componentss(VNV)_ ,• SDS(Design spectral response accejeration_at short.per odl,.g)_ ?_ Sot(Design spectral respori acceleration at d3seco921 perjod,g)= R(Response modification coefficient)= co2 (System overstrength factor)= o..-; ;n,n4d,ea I Dilo-d Ca(Deflection amplification factor)_ 1p(Importance factor)= 1.5 DATE:03/08/2021 Height to Center of Gravity above base= c, Equipment or Component Natural Frequencies(liz) . n ' • Overall dimensions and weight(or range thereof), f e✓ Tank(s)designed in accordance with ASME BPVQ,2015: ❑Yes-®•NO I List of Attachments Supporting Special Seismic Certification ® Test Report(s) ® Drawings ❑ Calculations ❑ Manufacturer's Catalog ❑ Other(s)(Please Specify): OSHPD Approval (For Office Use Only)—Approval Expires on December 31,2025 Signature: �-�� � ;�— �4-- Date: March 8,2021 Print Name T rfiothy /Piland Title: SSE Special Seismic Certification Valid Up to: Sos(g)= 2.00 z/h= 1 Condition of Approval(if applicable): "Access to Safe,Quality Healthcare Environments that Meet California's Diverse 11, 0S1f PD STATE OF CALIFORNIA—HEALTH AND HUMAN SERVICES AGENCY rl OSH-FD-759(REV 12/16/15) Page 3 of 3 Information is subject to change without notice.Check local codes. Printed 08/11/2022 is Y O RK® York® Sun TM Pro 3-12.5 Ton Page:16 Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO90S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED SERVICE DRIVE Seismic Certification Table 1-Certified Components Manufacturer. Johnson Controls and other Unitary Product Group brands(York Coleman,Luxaire,Evcon,Fraser-Johnston and Ready Ship) Product Line: JCI Packaged Rooftop Units Product Construction:Cabinet's constructed of G90 galvanized 1,000 hour salt spray(per ASTM-8117)rated powder-coated 20 gage carbon steel wrapper and duct panel with integral corner posts,all attached atthe base to four(4)full perimeter 14 gage base rails with 410 sheet metal screws. Options:230-575 V,economizer,power exhaust,electric or gas heater,variable frequency drive Mounting Description:Rigid or Flexible Curb Mounting - ' - Dimensions(inches) Nominal .; Operating Cooling; ',induct Line MzidefNumber'" '" r SCIS(g),711i=1 Unit - Depth Width Height Weight(lb) Capacity - (Tons) - ZH/ZU/JA3 037 89 59 42 860' 3 3 72/ZW/1A3 037 89 59 42 740 3 Interpolated ZR/ZK/JA3 037 89 59 42 980' 3 1 ZT/ZV/JA3 037 89 59 42 922 3 Interpolated ZH/ZU/JA4049 89 59 42 763 4 Interpolated Predator Air Handling ZJ/ZW/1A4049 89 59 42 762 4 Interpolated Units(Short) ZR/ZK/JA4 049 89 59 42 880 4 20 Interpolated ZT/ZV/1A4049 89 59 42 960 4 Interpolated ZH/ZU/JA5 061 89 59 42 772 5 Interpolated 21/ZW/JA5061 89 59 42 1,070' 5 _ 4 ZR/ZK/JA5 061 89 59 „42- •-111:070.-- 5 2 ZT/ZV/JA5 061 89 59, +'__42' 96g'' _ -" 5 Extrapolated XP/XA/106078 89 1.59') 42 970' /6.5 .'•, 7 ZF/ZS/106 078 89 "-,59 42 1,090' 6.5 ,,,r' 10 ZH/ZU/106 078 89 - ,' 59 42 11-„910--, 'I 6.5 Interpolated ZI/ZW/106078 89_'.,' 59 - 51-=' ;1 4030 - 6.5 c<v'', Interpolated ZR/ZK/106 078 89'•. 59 51 1,060' 6.5 'c) 5 ZF/Z5/107090 89L- 59 142-,- .('8601."1 7.5 '.'1 Interpolated ZH/ZU/J07 090 89 59 42 910 7.5 . Interpolated 2J/ZW/J07090 89 59 51 1,081 7.5 Interpolated Xp/XA/J07090 89 59,,j :,,.,42_,:., , 9201-1i .-7.53 Interpolated ZR/ZK/107 090 89 59''' "'42'''` 'Y 965' ' `'7.5-' 2.0 Interpolated ZF/ZS/J08 102 89 59 51 1,020 8.5 Interpolated - ZH/ZU/J08102 89 59 51,, ,,,n 1,030,-,,-,,,, 8.5 Interpolated Predator Air Handling 21/ZW/J08102 89 59M I =. 'S1•J/LJ U1,060-1.! I 8.5 Interpolated Units(Standard) - - - XP/KA/108 102 89 59 51 �,1,135 8.5 I,• Interpolated • ZR/ZK/108 102 89' 59 51 c'1,200 8.5 ,`e-. Interpolated ZF/ZS/110120 89 - - 59 51 =j l II'1,060 10 .t' Interpolated ZH/ZU/110120 _ 89 '...,..59 51 ;';'ji 1,090 10 Interpolated L/ZW/J10120 89 L59., 51 1,070 10';j'' Interpolated XP/XA/J10 120 89 59.1'p ,51 ''"1,135 7,10' Interpolated ZR/ZK/110120 89 59 ''1 51y/j 't n T200q':\ , 10 Interpolated ZF/ZS/112 150 119.5 59 51 '`1,253 12.5 Interpolated ZH/ZU/J12 150 119.5 59 51 1,250' 12.5 11 XP/XA/J12 150 119.5 _ 59 51 1,510' 12.5 2.0 8 ZJ/ZW/J12 150 119.5 59 51 1,570' 12.5 9 ZR/ZK/112150 119.5 59 51 1,600' 12.5 6 ZT/ZV 120 119.5 59 51 1,470' 10 12 Predator Air Handling- _ ZT/ZV 078 119.5 59 51 1;550 6.5 Interpolated Units(Ultra High ZT/ZV 090 119.5 59 51 1,550 7.5 2.0 Interpolated Efficiency) ZT/ZV 102 119.5 59 51 1,575 8.5 Interpolated ZT/ZV 150 119.5 59 51 1,680' 12.5 13 1.Weights listed for tested units are actual,not approximate weights.The weights listed for interpolated units are maximum weights,auuming all optional features are Included.Optional features are summarized In the table below. 2.Model numbers are generalized for each type of unit and the associated BTU tonnage thatthe unit can output. Unit Accessory Operating Weight(lbs.) Economizer 85 Power Exhaust 35 Electric Heat 49 Gas Heat 110 Variable Frequency Drive 30 1.Weight given is for the maximum electric heater size available. 2.Weight given for the gas heater is for the maximum number oftube heat exchangers available(8 tube). 3.Weightincludes mounting hardware,controls and manual bypass option. Information is subject to change without notice.Check local codes. Printed 08/11/2022 YORK® York® Sun TM Pro 3-12.5 Ton Page:17 Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO90S18R2D1AAD1A2 Quantity: 1 Tag#:ENCLOSED SERVICE DRIVE 1 RC0471 Roof Curb RIGHT 80-5/8 INSULATED DECK UNDER CONDENSER SECTION 20 `0 SUPPLY O 20 6 ` DUCT SIZES: ♦�:``_'/i Return 19.5 x 29.5 RETURN Supply 19.5 x 29.5 2 TYP. �. ROOF OPENING: 46 Long �♦ / 30 Wide 30 ` 50-1/2 ► INSULATED DECK UNDER COMPRESSOR SECTION FRONT . 14" Supply and Return Air(Including duct support rails)as shown,are typical for bottom duct applications. For location of horizontal duct applications(On rear of unit),refer to Unit Dimensions details. 1RC0471 Roof Curb Dimensions Information is subject to change without notice.Check local codes. Printed 08/11/2022 York® Sun TM Pro 3-12.5 Ton Page:18 II YORK Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO78S18P2D1AAA1A2 Quantity: 1 Tag#:WASH I DETAIL System: ZJO78S18P2D1AAA1A2 BAYS Cooling Performance _ Total gross capacity 83.3 MBH , I)tP. :. ' Sensible gross capacity 60.9 MBH i Imo, 4 Total net capacity 79.5 MBH �a I , \ Sensible net capacity 57.1 MBH11 Efficiency(atARl) 11.80 EER ' ,I I �, i %, 'id Integrated eff.(at ARI) 14.60 IEER 15 ', , ' Ambient DB temp. 95.0 °F t'r ° : Entering DB temp. 83.2 °F I fl r? t_ Entering WB temp. 69.2 °F � I �\ Leaving DB temp. 61.7 � `• ' Leaving WB temp. 59.7 °F ` Leaving air temp dew point 58.50 °F i.Power input(w/o blower) 5.91 kW , Sound power 85 dB(A) l Refrigerant ••' Refrigerant type R-410A Sys1 5 lbs 12 oz Sys2 5 lbs 12 oz 6.5 Ton Gas Heating Performance • York Sun Pro units are manufactured at an ISO 9001 registered facility and Entering DB temp. 60 °F each rooftop is completely computer-run tested prior to shipment. Heating output capacity(Max) 144 MBH Unit Features Supply air 2626 CFM • Two Stage Cooling Heating input capacity(Max) 180 MBH Leaving DB temp. 110.8 °F • 180 MBH Input Stainless Steel,Two Stage Gas Heat Air temp.rise 50.8 °F • Full perimeter base rails with built in rigging capabilities SSE 80.0 % • Unit Cabinet Constructed of Powder Painted Steel,Certified At 750 Hours Stages 2 Salt Spray Test(ASTM B-117 Standards) Supply Air Blower Performance • Scroll Compressor[s] Supply air 2626 CFM • Dry Bulb Low Leak Economizer w/Barometric Relief and Power Exhaust and Ext.static pressure 0.6 IWG Hoods(Bottom or Horizontal End Return Only)with Economizer Fault Addl.Unit Losses(Options/Accessories) 0.02 IWG Detection&Diagnostic(Meets ASHRAE 90.1-2013,IECC 2015,California Blower speed 820 RPM Title 24,AMCA 511). Max BHP of Motor(including service factor) 1.73 HP Duct location Bottom • 1.5 HP Standard Static Belt Drive Blower Motor rating 1.50 HP • Solid Core Liquid Line Filter Driers Actual required BHP 1.20 HP • Unit Ships with 2"Throwaway Filters Power input 1.12 kW • Replacement Filters:4-(24"x 20").Unit accepts 2"or 4"wide filters. Elevation 0 ft. • Short Circuit Current:5kA RMS Symmetrical Drive type BELT Outside/Mixed Air • Single Point Power Connection Outside Air Cfm 1076 CFM • Through-the-Curb and Through-the-Base Utility Connections Outside Air DB temp. 95 °F • Micro-Channel"all-aluminum"condenser coil,Copper tube/aluminum fin Outsided Air WB temp. 78 °F evaporator coil Outside Air RH 47.3 % • Composite Drain Pan-Front Connection Return Air CFM 1550 CFM • Tool-free maintenance with features like hinged doors for all-access panels, Return Air DB temp. 75 °F slide-out blower and blower motor tray Return Air WB temp. 62 °F Return Air RH 48.1 % BAS Controller Electrical Data • IntelliSpeed control of the VFD based on stages of cooling.Provides Single Power supply 208-3-60 Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10. Unit min circuit ampacity 39.2 Amps • Smart Equipment Controller including Discharge Air,Return Air,and Outdoor Unit max over-current protection 50 Amps Air Temperature Sensors. Dimensions&Weight Standard Unit Controller: Smart Equipment Control Board Hgt 51 in. Len 89 in. Wth 59 in. • Safety Monitoring-Monitors the High and Low-Pressure Switches,the Weight with factory installed options 1285 lbs. Freezestats,the Gas Valve,if Applicable,and the Temperature Limit Switch Clearances on Gas and Electric Heat Units.The Unit Control Board will Alarm on Ignition Right 12 in. Front 36 in. Rear 36 in. Failures,Safety Lockouts and Repeated Limit Switch Trips. Top 72 in. Bottom 0 in. Left 36 in. Warranty Note: Please refer to the tech guide for listed maximum static pressures • One(1)Year Limited Warranty on the Complete Unit ram-* • Five(5)Year Warranty-Compressors and Electric Heater Elements .A•uli CERTIFIED.,; 9<1le'lisx-Wdz.c..,:@Tr.i0 • Fifteen(15)Year Limited Warranty-Stainless Steel Heat Exchanger ..w.as.a.yd° CDIItlURTh Information is subject to change without notice.Check local codes. Printed 08/11/2022 i York® Sun TM Pro 3-12.5 Ton Page:19 YORK Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO78S18P2D1AAA1A2 Quantity: 1 Tag#:WASH/DETAIL System: ZJO78S18P2D1AAA1A2 BAYS Additional Electrical Data Power supply 208-3-60 Unit min circuit ampacity 39.2 Amps Unit max over-current protection 50 Amps Min Voltage 187 V Max Voltage 252 V Comp#1 RLA 11.2 Comp#1 LRA 84.0 Comp#2 RLA 11.2 Comp#2 LRA 84 Indoor Mtr Voltage 208-3-60 Indoor Mtr FLA 5.2 Outdoor Mtr Qty 2 Outdoor Fan Voltage 208-1-60 OD Fan Mtr FLA(ea.) 1.65 Power Ex Mtr Qty 1 Powered Ex Voltage 208-1-60 Power Ex Mtr FLA(ea) 5.5 York® Sun TM Pro 3-12.5 Ton Page:20 YORK Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO78S18P2D1AAA1A2 Quantity: 1 Tag#:WASH/DETAIL System: ZJO78S18P2D1AAA1A2 BAYS Factory Installed Options ZJO78S18P2D1AAA1A2 Equipment Options Option(s) Selected Single Packaged R-410A Air Conditioner, High Product Category: ZJ Efficiency 11.8 EER Nominal Cooling Capacity: 078 6.5 Ton Two Stage Cooling Heat Type and Nominal Heat Capacity: S18 180 MBH Input Stainless Steel,Two Stage Gas Heat 1.5 HP Standard Static Belt Drive Blower IntelliSpeed control of the VFD based on stages of Blower Option: P cooling(Provides Single Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10) Voltage: 2 208/230-3-60 Dry Bulb Low Leak Economizer w/Barometric Relief and Power Exhaust and Hoods(Bottom or Horizontal End Outside Air Option: D Return Only)with Economizer Fault Detection& Diagnostic(Meets ASHRAE 90.1-2013, IECC 2015, California Title 24,AMCA 511). Service Options: 'I Sensor Options: A Smart Equipment Controller including Discharge Air, Controls: A Return Air,and Outdoor Air Temperature Sensors. Micro-Channel"all-aluminum"condenser coil,Copper Refrigeration: A tube/aluminum fin evaporator coil Additional Options: 1 Standard 2"Throwaway Filters Composite Drain Pan-Front Connection Tool-free maintenance with features like hinged doors for Cabinet Options: A all-access panels,slide-out blower and blower motor tray Product Generation: 2 Field Installed Accessories O 1 BD0408-Burglar Bars (32.0 Ibs) 0 1 FF0414-2" Only Metal Filter 0 1 RC0470-Roof Curb-8" High, O 1CG0420-Coil Guard (27.0 Ibs) Frame Kit(16.0 Ibs) Flat, Uninsulated, Full Perimeter O 1 CV0403-Concentric 0 1 FL0402-Permanent 2"only (Shipped Knocked Down)(135.0 Diffuser,Flush Mount,20RD Filter Kit(Includes(4) Four Filters) Ibs) O 1CV0412-Concentric (2.2 Ibs) 0 1RC0471 -Roof Curb- 14" High, Diffuser,Side Discharge,20RD 0 1 HG0411 -Hail Guard Kit- Flat, Uninsulated, Full Perimeter O 1FE0412-Flue Exhaust Diamond Pattern (37.0 Ibs) (Shipped Knocked Down)(135.0 Extension Kit(14.0 Ibs) 0 1HG0432-Hail Guard Kit- Ibs) Provent Style(25.0 Ibs) Information is subject to change without notice.Check local codes. Printed 08/11/2022 York® Sun TM Pro 3-12.5 Ton Page:21 ral PORK® Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO78S18P2D1AAA1A2 Quantity: 1 Tag#:WASH/DETAIL System: ZJO78S18P2D1AAA1A2 BAYS O 1RC0472-Roof Curb,Transition- 0 S1-CTSDTS-CTS Wired 0 S1-NSB8BHN241-0-Wall Sunline 7.5T thru 12.5T to Pro Temperature Sensor for Temperature and 3% Relative 3.0T thru 12.5T(Shipped thermostat I Duct*Also works for Humidity Combined Sensor, Full Assembled)(200.0 Ibs) LX Series (0.3 Ibs) Display,WHITE, NO JCI LOGO, O 1RC0476-Roof Curb-24"High, 0 S1-CTSHTS-CTS Hardwired NS8000 Series(0.4 lbs) Flat, Uninsulated, Full Perimeter Temperature Sensor for CTS 0 S1-NSB8BHN243-0-Wall (Shipped Knocked Down)(135.0 Thermostats*Works with LX Temperature and 3% Relative Ibs) series as well (0.2 Ibs) Humidity Combined Sensor, Full O 1 RC0479-Transition Roof Curb- 0 S1-CTSPLATE-Wall Plate for Display, BLACK, NO JCI LOGO, 8" High, Sunline to Pro CTS Thermostats*Also works for NS8000 Series(0.4 Ibs) O 1WC0412-Wooden Crate (445.0 new platform LX series models 0 S1-NSB8BPN240-0-Wall Ibs) below(0.0 Ibs) Temperature and 2% Relative O 2AP0402-Air Proving Switch (1.0 0 S1-CTSWFTS-CTS Temperature Humidity Combined Sensor, Full Ibs) Sensor with WiFi for CTS Display,WHITE, JCI LOGO, O 2AQ04700524-CO2 Space Thermostats*Also works with LX NS8000 Series(0.4 Ibs) Sensor-Wall Mount Accessory Series(0.1 Ibs) 0 S1-NSB8BPN241-0-Wall (5.0 Ibs) 0 S1-LXLOCK-Locking Ring For Temperature and 2% Relative O 2AQ04700624-CO2 Unit Mount LX-Series Thermostats(0.4 Ibs) Humidity Combined Sensor, Full Accessory(4.6 Ibs) 0 S1-LXPLATE-Wall Plate For LX- ' Display,WHITE, NO JCI LOGO, O 2DF0403-Dirty Filter Switch (1.0 Series Thermostats(0.0 Ibs) NS8000 Series(0.4 lbs) Ibs) 0 S1-LXWFM -For LX Series 0 S1-NSB8BPN243-0-Wall O 2EC0401 -Kit, Single Enthalpy Thermostats-WiFi Temperature and 2% Relative Field Installed (1.0 lbs) Communication (0.1 Ibs) Humidity Combined Sensor, Full O 2EC0402-Kit, Dual Enthalpy 0 S1-MP-PRTKIT-OP-MAP Display, BLACK, NO JCI LOGO, Field Installed (Includes two (Multiple Access Portal) Gateway NS8000 Series(0.4 Ibs) humidity sensors)(1.0 Ibs) Kit-Replacement MAP gateway 0 S1-NSB8BTN041-0-Wall O 2LA04702412-Low Ambient Kit- protective case, lanyard and Temperature Sensor, No Display, ICM 333 (2.2 Ibs) communication cable. Use only to WHITE, NO JCI LOGO, NS8000 O 2SD04700824-Smoke Detector replace worn or damaged Series(0.4 Ibs) Kit w/Mounting Hardware for components. (0.3 Ibs) 0 S1-NSB8BTN043-0-Wall Supply Air(Horizontal/Downflow) 0 S1-NSB8BHN041-0-Wall Temperature Sensor, No Display, Only(9.4 Ibs) Temperature and 3% Relative BLACK, NO JCI LOGO, NS8000 O 2SD04700924-Smoke Detector Humidity Combined Sensor, No Series(0.4 Ibs) Kit w/Mounting Hardware for Display, WHITE, NO JCI LOGO, 0 S1-NSB8BTN141-0-Wall Return Air(Downflow Only)Only NS8000 Series(0.4 Ibs) Temperature Sensor, (10.0 Ibs) 0 S1-NSB8BHN043-0-Wall Warmer/Cooler Display,WHITE, O 2SD04701024-Smoke Detector Temperature and 3% Relative NO JCI LOGO, NS8000 Series Kit w/Mounting Hardware for Humidity Combined Sensor, No (0.4 Ibs) Supply(Horizontal/Downflow)and Display, BLACK, NO JCI LOGO, 0 S1-NSB8BTN143-0-Wall Return Air(Downflow Only)(8.0 NS8000 Series(0.4 Ibs) Temperature Sensor, Ibs) 0 S1-NSB8BHN141-0-Wall Warmer/Cooler Display, BLACK, O S1-03102529000-Non- Temperature and 3% Relative NO JCI LOGO, NS8000 Series Humidity Wall Sensor-Allows Combined Sensor, (0.4 Ibs) remote sensing and control from Warmer/Cooler Display,WHITE, 0 S1-NSB8BTN240-0-Wall single or multiple zones. (0.2 Ibs) NO JCI LOGO, NS8000 Series Temperature Sensor, Full Display, O S1-03102529004-Non- (0.4 Ibs) WHITE, JCI LOGO, NS8000 Networking Wall Sensor with 0 S1-NSB8BHN143-0-Wall Series(0.4 Ibs) Over-ride button-Allows remote Temperature and 3% Relative 0 S1-NSB8BTN241-0-Wall sensing and control from single or Humidity Combined Sensor, Temperature Sensor, Full Display, multiple zones. Override allows Warmer/Cooler Display, BLACK, WHITE, NO JCI LOGO, NS8000 setpoint to be overridden for 2 NO JCI LOGO, NS8000 Series Series(0.4 Ibs) hour time period. (0.2 Ibs) (0.4 Ibs) 0 S1-NSB8BTN243-0-Wall 0 S1-ADDWIRE-Add-a-Wire allows 0 S1-NSB8BHN240-0-Wall Temperature Sensor, Full Display, 5-wire thermostats to use only 4 Temperature and 3% Relative BLACK, NO JCI LOGO, NS8000 wires. (0.3 Ibs) Humidity Combined Sensor, Full Series(0.4 Ibs) Display,WHITE,JCI LOGO, NS8000 Series(0.4 Ibs) Information is subject to change without notice.Check local codes. Printed 08/11/2022 York® Sun TM Pro 3-12.5 Ton Page:22 YORK Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO78S18P2D1AAA1A2 Quantity: 1 Tag#:WASH/DETAIL System: ZJO78S18P2D1AAA1A2 BAYS O S1-SE-COM1001-0-Field 0 S1-TEC3631-14-000-7 DAY Installed Communication Card for PROGRAMMABLE Simplicity SE control. Can be field THERMOSTAT, OPTIONAL MSTP configurable for BACnet, N2 or OR N2 COMMUNICATION, ModBUS MSTP (0.0 Ibs) RTU/HEAT PUMP WITH ECON, O S1-TBSU305-Y-York Branded LX OCC SENSOR, FULL COLOR, Series 13" LCD Display 13/4 WHITE,JCI LOGO(0.8 Ibs) Stage Heating 12 Stage Cooling I 0 S1-TEC3631-16-000-7 DAY (5+1+1)7-day Programmable(1.0 PROGRAMMABLE Ibs) THERMOSTAT, OPTIONAL MSTP O S1-TEC3030-14-000-7 DAY OR N2 COMMUNICATION, PROGRAMMABLE RTU/HEAT PUMP WITH ECON, THERMOSTAT,ZIGBEE PRO OCC SENSOR, FULL COLOR, WIRELESS COMMUNICATION, WHITE, NO LOGO(0.8 Ibs) RTU/HEAT PUMP WITH 0 S1-YK/AN-RSO-ACI -Non- ECON,FULL COLOR,WHITE, JCI Networking Wall Sensor with LOGO (0.8 Ibs) Setpoint Adjustment and Over-ride O S1-TEC3030-16-000-7 DAY Button—Allows remote sensing PROGRAMMABLE and control from single or multiple THERMOSTAT, ZIGBEE PRO zones. (1.0 Ibs) WIRELESS COMMUNICATION, 0 S1-YK-MAP1810-0P-MAP RTU/HEAT PUMP WITH ECON, (Multiple Access Portal) Gateway- AND FULL COLOR,WHITE, NO For use with SimplicitySE Control. LOGO(0.8 Ibs) (0.2 Ibs) O S1-TEC3031-14-000-7 DAY 0 S1-YK-MAP1810-0S-Stationary PROGRAMMABLE MAP Gateway(Includes MAP THERMOSTAT, ZIGBEE PRO Gateway, Field Bus Adapter, WIRELESS COMMUNICATION, Mounting Bracket and 100 to 240 RTU/HEAT PUMP WITH ECON, VAC Power Supply). US- OCC SENSOR, FULL COLOR, compatible counties. (1.9 Ibs) WHITE, JCI LOGO (0.8 Ibs) O S1-TEC3031-16-000-7 DAY PROGRAMMABLE THERMOSTAT,ZIGBEE PRO WIRELESS COMMUNICATION, RTU/HEAT PUMP WITH ECON, OCC SENSOR, FULL COLOR, WHITE, NO LOGO (0.8 Ibs) O S1-TEC3630-14-000-7 DAY PROGRAMMABLE THERMOSTAT, OPTIONAL MSTP OR N2 COMMUNICATION, RTU/HEAT PUMP WITH ECON,FULL COLOR,WHITE, JCI LOGO(0.8 Ibs) O S1-TEC3630-16-000-7 DAY PROGRAMMABLE THERMOSTAT, OPTIONAL MSTP OR N2 COMMUNICATION, RTU/HEAT PUMP WITH ECON,FULL COLOR,WHITE, NO LOGO (0.8 Ibs) Information is subject to change without notice.Check local codes. Printed 08/11/2022 ill! ® York® Sun TM Pro 3-12.5 Ton Package Page:23 YORK® Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO78S18P2D1AAA1A2 Quantity: 1 Tag#:WASH/DETAIL BAYS Consolidated Drawing I 2 3 4 5 6 7 8 9 10 II 12 13 14 15 16 NOTES: OPERATING CENTER OF GRAVITY I, FOR OUTDOOR USE ONLY. TONNAGE UNIT• WEIGHT (UNIT) LOCATION(BASE UNIT) 4 POINT CORNER LOADS(LOS)(BASE UNIT) K 2. WEIGHTS SHOWN ARE FOR COOLING ONLY UNITS. ~ --32.67 6.5 10/IN 030 MN 40(10161 2516351 0 6351 245 11111 97(891 262 E1191 321 11481 N 3. MIN. CLEARANCES TO BE: [829,8] 7,5 20/1N 080(4901 39 1990,61 24(609.61 245 11111 89 1861 281 11281 745 11661 RIGHT SIDE: 12 [305] 8.5 28/29 084 14921 38 1965,21 24(609.61 255 1116] 10 MIN Des 14921 39(990,6) t5(6751 257((IT) 93(88] 99(901 214 11241 361 116/1 LEFT SIDE: 36 [915] fi.63 214 11241 355(1611 [173,51~ 8.5 01/25 007(4581 38 1965,21 24(609,61 235 11011 75 1791 255 11161 342(1561 FRONT: 36 [915] 10 2F/2S 103(5011 38 1965,21 24(609.61 251 1117] 92(81) 279 11271 3/5(110] REAR: 36 [915] 24.38 �{ 8.5 2H/IU 030 14671 38 1965,21 24[609,61 240 11091 79(811 261(118] 350(159] - TOP: 72 [1830] [619,21 + I 10 29/28 090 14941 381965,21 24(609,61 254 11151 89(86] 276 11251 371 (1681 BOTTOM: 0 [0] 6.5 23/28 030(4611 39(990,61 25 16351 245(1111 91 (811 260 11181 - 333 11511 3 4. TO REMOVE THE SLIDE-OUT DRAIN PAN, A REAR CLEARANCE OF 7.5 23/2W 050(416] 39(990,61 7516351 250(1171 95(891 265 11201 34011541 8.5 23/211 060 14811 38 1965,21 24 1609,61 247(1121 84(841 268 11221 360(1631 3 60 in (1525 Inm) IS REQUIRED. IF SPACE IS UNAVAILABLE, THE -4 IBM 1.84 10 23/n 070 14851 -39(990.61 24(609,61 245 11111 91 (811 218 11261 357(1671 DRAIN PAN CAN BE REMOVED THROUGH .5 4 ID 2R/2N 200(5441 38 1965.21 25.5(647,11 291 11351 221 11001 291 11321 390 11771 _THE FRONT BY SEPARATING 8 THE CORNER WALL. [45T,2) [199,. ] 6.5 OP/IA 080(4901 38 1965.21 2516351 262(1191 95(89] 266(121) 357 n@21 5. FOR SMALLER SERVICE AND OPERATIONAL CLEARANCES [6.75 7.5 IP/IA 090(4941 38(965.21 27 1584,21 243 11101 81 (821 284 11291 381 (1131 CONTACT YOUR APPLICATION ENGINEERING DEPARTMENT. 32.06 - I [171,61 8.5 [P/[A 137(5161 38(965.21 25.5(641,1] '28211281 210 MI 276 11251 30(1681 I8)4.41 + 10 OP/IA 175(5151 38(965.21 25.5[641,1) 281 11211 209(951 275 11251 389 11671 6, DOWNFLOW DUCTS DESIGNED TO BE ATTACHED TO ACCESSORY A H ROOF CURB ONLY. IF UNIT IS MOUNTED SIDE SUPPLY, IT , . . IS RECOMMENDED THAT THE DUCTS ARE SUPPORTED BY 24 24 �� '�\ 'B 10.50 18.25 x CROSS BRACES, AS DONE ON ACCESSORY ROOF CURBS. ALTERNATE CONDENSATION DRAIN 11111 7. SIDE DUCT FLANGES ARE 0.75" HIGH. [615,6] R (Si 1 - -1 n„4 ,,,�(,P [266,71 [463,6] BOTTOM DUCTS DO NOT HAVE FLANGES. (FROM FLANGE)MTB. • E P j �42 �i�.,,IJ1 __ o —e,_ 8. MINIMUM CONDENSATION TRAP HEIGHT SHALL BE 1.5 TIMES T 27 50' P [609�6] ppri;*MM THE LOWEST NEGATIVE STATIC, [698,5] L `=siR9. DIMENSIONS IN [ ] ARE IN MILLIMETERS OR KILOGRAMS. t N Y RIGF[T E• 11 O 10. OPTIONAL COIL GUARDS, POWER E%HAUST, GAS HEAT, �T IB 25r/ T 28.25 G ECONOMIZER, DISCONNECT SWITCH, CONVENIENCE OUTLET, - 1 ` [463,6] EaAgEg --_ A [717,6] AND BAROMETRIC RELIEF AND FRESH AIR HOODS SHOWN. I I -i ry.-z Sr ,.I. s-- 11 - } - 21,00y, ,r i�i�y N Ilk ©EXCEPT XP/XA (HEAT PUMP) UNITS. 20.39 I 19 IA 21.00 ] �'�'' = [518.0] 20.14 17.14 Y _j a",Ni _ _- [486,21 [435,41 I' !q%7 _ DIRECTION OF AIRFLOW I [511.6] .,4j- - 11 )t )`111, I18,06 -� + i I ; [ O tea;`-��' 11•j,:'�� I [[458,71 F S CENTER OF GRAVITY 14.47 0 L' FRONT _ � F IOTTOM GAS --� �'C0 [367,61 - i' 16.39 OTTOM ENTRY: SUPPLY ENTRY 952.00 [50,81 2.88 5.16 18.06 - ., [416,41 POWER 02.50 [63,5] [131,11 28.25 31.63 [73,2] 1458,8] - 1 18.89 CONTROL 3%4 0.875 [22.231 [717,61 [803,4] % [479,91 •ropy REAR MARTIAL VIEW OUTSIDE AIR (INTAKE HOOD NOT SHOWN IN THIS VIEW) E INTAKE HOOD DISCONNECT SWITCH COVER {� E 88,18 (OPTIONAL) (OPTIONAL) [2239,91 POWER ENTRY 952.50[63,5] I -- — 58.09 [1475,5] 25.72 - r-_-'i - FREsx AIA xpoD/ I AS INLET 1ECONO25.72 1 FRESH TIER I BLOWER ACCESS iTIOPTIONALI ILTER/— COM PANEL/ MPRESSOR COXPAESSOA I CONTROL ENTRY 00.875[ 22 �- ACCESSCCESSPOWER ENTRY 02.50 [6351 _I ® g4 !e= 50.75 -- - I _.I'��� �•I�_=_ [1289.I] — BAROMETRIC RELIEF HOOD/ e, -== - , —_ ,17 �I. POWER EXHAUST Al; I ____ C no . :�-w_.,-� —� (OPTIONAL) ;-��1� - e C . •�: Ob CONVENIENCE OUTLET COVER IFE'T VIFW (OPTIONAL) —27.31 21.19 -- 11.38 [693,71 SEE DETAIL A FOR [538,21 [289,1] On. S 00. CONVENIENCE OUTLET DRAIN LOCATION EXHAUST A 1-. 59.00 POWER ENTRY 00.875(22.231 FLUE [1498,61 3/4" FPT - 89.00 OIL GUARD e [2260,61 ROW VIF11[ 91,GHT VIEW (OPTIONAL) B (OPTIONAL FRONT COIL GUARD NOT SHOWN IN THIS VIEW) ,1r , p[V DATE REVISION RECORD EC NO DR CH ENG THIRD ANGLE IRO3ECTIOA A44 PAD@11GRT NIOHR IN lx[6YDIIC8 RATTLN NCR(OP ARI RESIRY(D ANO NO P4AR1a510D 541L/1 AND 8[Y ,.O. LEV IS GRNMT[D 10 NCIROOYC[tX15 PAIYI IN.HOIC OA IY P491 OR OI101506 ANI 01 INC • O CHA AACI[A151 C3 PER A 02•I •I.20 NEW DRAWING (FROM UST-PRED-F SOH/ 15768 LOP RCN SAA wroRN4nON uroY It to 018844 nrxour Nu rnn 601166[Wr 100680R 00610003 8C-PpP 3TO.01 5.37 -. - ,©1 DRAWING PER ASK T14.5-2009 MATERIAL [136,4] _ "1,,,,/ I41n4ACa,W114411nn11FPRIM SUBMITTAL DWG, PRO TYPE NOT APPLICABLE p2t1 -1=1 R SAT: DU PIKE D[CIN41 a f.1 STD FLAT COIL. 50" CAB nG sett NOT APPLICABLE A 1 DAtl L.woo I1•I I•20 LWO PIKE DlCI14, 4.01 _SIiE • (HA I.HOW42.11a1 Huff PL4CE Haw :.DID JOHNSON CONTROLS DIG U. REV �A FAG I.A1111 12-IP71 4AEd86= *0 UNITARY PRODUCTS GROUP 5883785 O)TA A SCALE 0.300 MFG DIoE0910n 4RE Il INCHES PART N0. SCALE 0,015 DO Nor SLUE(P11N1 NORMAN,OR 73069 ( se l0 I DC I I I 2 3 4 5 6 7 8 9 10 II 12 13 ' 14 15 16 Information Is subject to change without notice.Check local codes. Printed 08/11/2022 3 YORK® York® Sun TM Pro 3-12.5 Ton Page:24 Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO78S18P2D1AAA1A2 Quantity: 1 Tag#:WASH/DETAIL BAYS Component Locations Cooling With Gas Heat(6.5 Through 10 Tons) Smart EquipmenV'1 control board Filter drier Disconnect location Filter access w/screw connector for T-stat (2"or 4"filter options) (solid core) wiring and network connections (optional disconnect switch) Terminal block for Micro-Channel Aluminum hi-voltage connection F,. Tube/Aluminum Fin e-� • Condenser Second model nameplate ;i �� Slide-out motor and inside hinged - +, r blower assemblyfor access panel ` —/— ,' t � I �� 'i _ % , easy adjustment Dual stage I ' and service cooling for �, " a ,` I I I Belt-drive maximum '•� S ,; } l_� ✓iio i • blower motor comfort i j ��� g, i 4, r- l fp, i EEEnal) efficiency �f .i 11 t,'�il "A r •II t • steel tubular heat compressor) h^1\.. Ni, 5.o \ .t J lI exchanger for long life .% ', t' 1 ,>- - ,.01" (stainless steel option) �� `� " 1, Two-stage gas Base rails w/forklift %J''" heating to maintain slots(three sides) i • . i Slide-out drain pan warm,comfortable and lifting holes ` w i --• -- temperature with 1"NPT, Roof curbs in eight-and `" Intelligent control g i female connection 9 fourteen-inch heights.Roof�~ �-- board for safe and curbs for transitioning from Compressor#1 access efficient operation York SunlineTM footprint to Side entry power the ZH/ZJ/ZR/ZUIZW/ZK Toolless and control wiring (high-efficiency compressor) door latch knockouts Series footprints are also available(field installed accessory) Information is subject to change without notice.Check local codes. Printed 08/11/2022 York® Sun TMPro 3-12.5 Ton Page:25 layoRK® Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJ078S18P2D1AAA1A2 Quantity: 1 Tag#:WASH/DETAIL BAYS Low Leak Downflow Economizer Low Leak Downflow Economizer(shown with optional Power Exhaust) �` w �`1fir ` y�r.. \\ate �%- ^S ��—�JIIL Fresh Air Hood ��a F itz----MrAriii --' '''I ,ii, IN , j'III I � (included) _____•_ ,03,,,, z.............. 4.:...,..:..„...„._.:.: 100 �•��_�� to -..-,,--1,,,---_,_, .,iii, , k-- "-_,-. ri -i'.'ilde; •- •'-- .zis----------- Low Leak Economizer(included) I_ Power Exhaust(optional) Barometric Relief Damper Barometric Relief (included) Hood (included) Low leak economizers are capable achieving low leakage rates of 3 cfm/sq. ft at 1"of static pressure, meeting or exceeding the following standards: ASHRAE 90.1-2010 ASHRAE 62 AMCA 511 (licensed as Class 1A damper) International Energy Conservation Code (IECC) California Title 24 The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. Information is subject to change without notice.Check local codes. Printed 08/11/2022 rigiyoR ® York® Sun TM Pro 3-12.5 Ton Package Page:26 I I' 1 Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO78S18P2D1AAA1A2 Quantity: 1 Tag#:WASH/DETAIL BAYS Factory Installed Power Exhaust SP-in.-wg. 0 o 0 o o O 0 0 O O O t+ J 4.1 - Ui 01 J C7 i0 F, O 0 0 0 O 0 O 0 0 O O O O O N a O O 0 fa7 M Ia O 3 O c K VI IN O Nc 1'F O 0 • 0 O w O O O O O O O lJ 01 to O O O O BHP Information is subject to change without notice.Check local codes. Printed 08/11/2022 YORK® York® Sun TM Pro 3-12.5 Ton Page:27 Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO78S18P2D1AAA1A2 Quantity: 1 Tag#:WASH/DETAIL BAYS Seismic Certification OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT Irbil FACILITIES DEVELOPMENT DIVISION j APPLICATION FOR OSHPD SPECIAL SEISMIC ---- OFFICE USE ONLY I CERTIFICATION PREAPPROVAL (OSP)_— — APPLICATION#: OSP-0213 OSHPD Special Seismic Certification Preapproval(OSP) Type: El New ® Renewal - - r---------'-'--— ----_.---------— ------------ - — �---- -- -- --__. -- n LManufacturerinform- -- --- Manufacturer: Johnson Controls Inc.(JCI) Manufacturer's Technical Representative: Cameron Boyce,Engineer II Mailing Address: 5005 Interstate Drive,Norman,OK,73069 • Telephone: (405)419-6830 cameron.w.boyce(mici.com Product InformationN. 444 • Product Name: Predator Rooftop Air,Conddioning_Units il L !lJ !4- Product Type: Packaged Air Conditioning Units OS p_fl21? Product Model Number: See attached (List all unique product identification numbers and/or pa rtnurtibars)�O f `/ J I I i The units are enclosures wit the following subcomponents:refrigerant compressors,outdoor General Description: fan motors,indoor coils,outdoor coils,reversing valve with coil,thermostatic expansion valves, standard indoor blower motor,Variable frequency dnve'fijndoor blower motor,exhaust fan motor,variable frequency drive,economizer,electric heater,heat cells,filters,and other miscellaneous items included in the subcomponent tables: C, ,-111 • Mounting Description: Units are rigid curb and isolated curb"base mounted .C)j), • ! 4 Applicant Information L LD9 ‘j v— Applicant Company Name: The VMC Group Contact Person: John Giuliano Mailing Address: 113 Main Street,Bloomingdale,NJ 07403 Telephone: (973)838-1780 Email: john.oiuliano@thevmcorouo.com I hereby agree to reimburse the Office of Statewide Health Planning and Development review fees in accordance with the California Administrative Code, 2016. Signature of Applicant: Date: 8/28/19 Title: President Company Name: The VMC Group "Access to Safe,Quality Healthcare Environments that Meet California's Diverse II)V OSHPD STATE OF CALIFORNIA—HEALTH AND HUMAN SERVICES AGENCY :!ii LI II�yi OSH-FD-759(REV 12/16/15) I Page 1 of 3 Information is subject to change without notice.Check local codes. Printed 08/11/2022 • YORK® York® Sun TM Pro 3-12.5 Ton Page:28 Package Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO78S18P2D1AAA1A2 Quantity: 1 Tag#:WASH/DETAIL BAYS Seismic Certification OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT ' i1l�li p), FACILITIES DEVELOPMENT DIVISION California Licensed Structural Engineer Responsible for the Engineering and Test Report(s) Company Name: The VMC Group Name: Kenneth Tarlow California License Number: SE-2851 Mailing Address: 113 Main Street,Bloomingdale,NJ 07403 Telephone: (973)838-1780 Email: ken.tarlow(cathevmcdroup.com Supports and Attachments Preapproval ❑ Supports and attachments are preapproved under OPM- (Separate application for OSHPD Preapproval of Manufacturer's Certification(OPM)of Supports and attachments is required) fCE)j , El Supports and attachments are not preappro{ed :_,'t., Certification Method �`° r _r D -cox ® Testing in accordance with: .®, ICC-ES AC156 ba, ❑ Other(Please Specify): : O S P-0213 Cal BY:Timothy J Piiand Testing Laboratory DATE:03/08/2021 Company Name: DCL Labs Contact Name: Josh Sailer,Laboratory-Manager Mailing Address: 1315 Greg Street,Suite 109,'Sparks,NV 89431:,r `) ur�IL.�tu'a- Telephone: (775)358-5085 Email: joshAshaketest.com "Access to Safe,Quality Healthcare Environments that Meet California's Diverse 1I�l� jp t 0 S P D STATE OF CALIFORNIA—HEALTH AND HUMAN SERVICES AGENCY +'' v1 tVI OSH-FD-759(REV 12/16/15) l Page 2 of 3 Information is subject to change without notice.Check local codes. Printed 08/11/2022 YORK® York® Sun TM Pro 3-12.5 Ton 3 Package Page:29 Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO78S18P2D1AAA1A2 Quantity: 1 Tag#:WASH/DETAIL BAYS Seismic Certification -iii4OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT ,16' FACILITIES DEVELOPMENT DIVISION Seismic Parameters Design in accordance with ASCE 7-16 Chapter 13: ®Yes LI No Design Basis of Equipment or Components(Fp/Wa)= Rigid Curb=1.5;Spring Isolated Curb=4.5 Sos(Design spectral response acceleration at short period,g)= 2.00 ap(In-structure equipment or component amplification factor)= 2.5 Rp(Equipment or component response modification factor)= Rigid Curb=6.0;Spring Isolated Curb=2.0 Co2 (System overstrength factor)= 2.0 la(Importance factor)=1.5 z/h(Height factor ratio)= 1 Equipment or Component Natural Frequencies(Hz)= _See attachment - Overall dimensions and weight(or range thereof)_„_, _ See attachment Equipment or Components @ grade designed.in accordance with ASCEi.7-16 Chapter 15: ❑Yes ®No Design Basis of Equipment or Components(V/W)_ , . „ , Sos(Design spectral response acceleration at short period.g)= Sol(Design spectral response"acceleration,at dssecond�period,g)= f R(Response modification coefficient)= S2o(System overstrength factor)= r.,„I-i „,,.p,\, I i i o r,r-i Ca(Deflection amplification factor)= la(Importance factor)= 1.5 D ATE: 03/03/2 J? Height to Center of Gravity above base= Equipment or Component Natural Frequencies(Hz)' r,":-' Overall dimensions and weight(or range thereof)'9, 1 . Tank(s)designed in accordance with ASME BPVC,'2015: ' 'LI y es-,-El,No • - �i,i f' List of Attachments Supporting Special Seismic Certification ® Test Report(s) ® Drawings ❑ Calculations ❑ Manufacturer's Catalog ❑ Other(s)(Please Specify): OSHPD Approval (For Office Use Only)—Approval Expires on December 31,2025 Signature: _ �� / Z Date: March 8,2021 Print Name...—. imothy/J.lPiland Title: SSE Special Seismic Certification Valid Up to: Sos(g)= 2.00 z/h= 1 Condition of Approval(if applicable): "Access to Safe,Quality Healthcare Environments that Meet California's Diverse 1 k 1 iillitOSHPD STATE OF CALIFORNIA-HEALTH AND HUMAN SERVICES AGENCY ;l;' 1 1 OSH-FD-759(REV 12/16/15) Page 3 of 3 Information is subject to change without notice.Check local codes. Printed 08/11/2022 iiii YORK® York® Sun TM Pro 3-12.5 Ton Package Page:30 Single Package R-410A Air Conditioner Project Name: GARVEY HYUNDAI Unit Model#: ZJO78S18P2D1AAA1A2 Quantity: 1 Tag#:WASH I DETAIL BAYS Seismic Certification Table 1-Certified Components Manufacturer. Johnson Controls and other Unitary Product Group brands(York,Coleman,LuxaIre,Evcon,Fraser-Johnston and Ready Ship) Product Line: id Packaged Rooftop Units Product Construction:Cabinet's constructed of G90 galvanized 1,000 hour salt spray(per ASTM-8117)rated powder-coated 20 gage carbon steel wrapper and duct panel with Integral comer posts,all attached atthe base to four(4)full perimeter 14 gage base rails with Is10 sheet metal screws. Options:230-575 V,economizer,power exhaust,electric or gas heater,variable frequency drive Mounting Description:Rigid or Flexible Curb Mounting Dimensions(inches) Nominal Product Line Model Number' - Operating Cooling'- Sds(g);z/h=l Unit Depth Width Height Weight(Ib) Capacity (Tons) ZH/ZU/JA3 037 89 59 42 860' 3 3 Z1/ZW/lA3 037 89 59 42 740 3 Interpolated ZR/ZK/JA3 037 89 59 42 980' 3 1 ZT/ZV/1A3 037 89 59 42 922 3 Interpolated ZH/ZU/JA4049 89 59 42 763 4 Interpolated Predator Air Handling 7.1/ZW/1A4049 89 59 42 762 4 Interpolated Units(Short) ZR/ZK/1A4049 89 59 42 ,880 4 20 Interpolated ZT/ZV/JA4049 89 59 42 960 4 Interpolated ZH/ZU/JA5 061 89 59 42 772 5 Interpolated 11/ZW/JA5061 89 59 42 1,070' 5 4 ZR/ZK/1A5 061 89 59 .42: ',i' 4,070'- 5 2 ZT/ZV/JA5 061 69 59 '._42 968 = 5 Extrapolated XP/XA/106 078 89 ,59' .' 42 970' -'6:5�„ 7 ZF/25/106 078 89 ".,.59 42 1,090' 6.5 10 Z1-1/ZU/106078 89 \.„' 59 42!=- 'I_ '910 , „ 6.5 -,,,-.9 Interpolated ZI/ZW/106078 89 ' 59 •--53• -1 •1030 - 6.5 - Interpolated ZR/ZK/106 078 89"', 59 51 1,060' 6.5 -`) 5 ZF/Z5/107090 09 59 f 42t-;' -1 '8601_y 7.5 Interpolated ZH/ZU/107 090 89 .59 . 42 910 7.5 Interpolated ZI/ZW/107090 89 59 51 1,081 7.5 Interpolated XP/XA/107090 89 59.;7 ;,,.42_,.;.-, r 920 i_'• ..•7.5.1 _ Interpolated ZR/ZK/107 090 89 59... ...42"• './ 965' ' "'7.5' Interpolated ZF/Z5/108 102 89 59 51 1,020 8.5 2.0 Interpolated ZH/ZU/108 102 89 59 51,-. ,,-,r�1,030,-„-,A 8.5 Interpolated Predator Air Handling L/Z1N/108102 89 591,! _:151J/ J lJ1,00.,) I 8.5 Interpolated Units(Standard) XP/XA/108 102 89 a 59 51 .-1,135 8.5 Interpolated ZR/ZK/108 102 89- -. 59 51 ''1,200 8.5 `,, Interpolated ZF/ZS/110120 89 '-" 59 51 ''i ;1,060 10 .-1 _ Interpolated ZH/ZU/110120 89 _59 51 • ' ' 1:090 30 Interpolated ZI/ZW/110 120 89 l 59' _ 51 r 4,1,070 10-? ' _ Interpolated XP/XA/110 120 89 59'.'I,'r ,51 '"1,135 t',10' Interpolated ZR/2K/110120 89 59 151'.'1 '5) 1,200,;.' . 10 Interpolated ZF/ZS/J12 150 119.5 59 51 • 1:253 12.5 Interpolated ZH/ZU/112 150 119.5 59 51 1,250' 12.5 11 XP/XA/112 150 119.5 59 51 1,510' 12.5 2.0 8 21/ZW/112150 119.5 59 51 1,570' 12.5 9 ZR/ZK/112 150 119.5 59 51 1,600' 12.5 6 ZT/ZV 120 119.5 59 51 1,470' 10 12 Predator Air Handling ZT/ZV 078 119.5 59 51 1,550 6.5 Interpolated Units(Ultra High ZT/ZV 090 119.5 59 51 1,550 7.5 2.0 Interpolated Efficiency) ZT/ZV 102 119.5 59 51 1,575 13.5 Interpolated ZT/ZV 150 119.5 59 51 1,680' 12.5 13 1.Weights listed for tested units are actual,not approximate weights.The weights listed for interpolated units are maximum weights,assuming all optional features are Included.Optional features are summarized in the table below. 2.Model numbers are generalized for each type of unit and the associated BTU tonnage thatthe unit can output. Unit Accessory Operating Weight(Ibs) Economizer 85 Power Exhaust 35 Electric Heat 49 Gas Heat 110 Variable Frequency Drive 30 1.Weight given is for the maximum electric heater size available. 2.Weight given for the gas heater is for the maximum number oRube heat exchangers available(8 tube). 3.Weightincludes mounting hardware,controls and manual bypass option. Information is subject to change without notice.Check local codes. Printed 08/11/2022 Page:31 Date 08/11/2022 Project Name GARVEY HYUNDAI F.W WEBB COMPANY Project Number Client/Purchaser Guide Specification Summary Page Product Series Models and Unit Tags York®Sun TM Pro 3-12.5 Ton Package ZJO90S18R2D1AAD1A2 ENCLOSED SERVICE DRIVE ZJO78S18P2D1AAA1A2 WASH/DETAIL BAYS Information is subject to change without notice.Check local codes. Printed 08/11/2022 rayoRK® Guide Specification for Page:32 York® Sun TM Pro GENERAL removing panels or creating bypass of the coils. York®SunT"" Pro units are convertible single packages Condensate pan shall be slide out design, constructed of a non corrosive material, internally sloped and with a common footprint cabinet and common roof curb conforming to ASHRAE 62-B9 standards. Condensate for all 6-1/2 through 12-1/2 ton models.All have two connection shall be a minimum of%" I.D.female and be compressors with independent R-410A refrigeration rigid mount connection. circuits to provide 2 stages of cooling.The units were designed for light commercial applications and can be INDOOR(EVAPORATOR) FAN ASSEMBLY easily installed on a roof curb, slab, or frame.All units are self contained and assembled on rigid full perimeter Fan shall be a belt drive assembly and include an base rails allowing for 3-way forklift access and adjustable pitch motor pulley.Job site selected brake overhead rigging. Every unit is completely charged with horsepower shall not exceed the motors nameplate R-410A,wired, piped, and tested at the factory to horsepower rating plus the service factor. Units shall be provide a quick and easy field installation.All units are designed to operate within the service factor. Fan wheel convertible between side and down airflow. Independent shall be double inlet type with forward curve blades, economizer designs are used on side and down dynamically balanced to operate smoothly throughout discharge applications, as well as all tonnage sizes. the entire range of operation.Airflow design shall be Predator®units are available in the following constant volume. Bearings shall be sealed and configurations: cooling only, cooling with electric heat, permanently lubricated for longer life and no cooling with gas heat, reheat only, reheat with electric maintenance. Entire blower assembly and motor shall be heat and reheat with gas heat. Electric heaters are slide out design. available as factory-installed options or field-installed OUTDOOR(CONDENSER) FAN ASSEMBLY accessories. DESCRIPTION The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to Units shall be factory assembled, single package, corrosion resistant steel spider brackets and shall be (Elec/Elec, Gas/Elec), designed for outdoor installation. dynamically balanced for smooth operation.The outdoor They shall have built in field convertible duct connections fan motors shall have permanently lubricated bearings for down discharge supply/return or horizontal discharge internally protected against overload conditions and supply/return and be available with factory installed staged independently.A cleaning window shall be options or field installed accessories.The units shall be provided on two sides of the units for coil cleaning. factory wired, piped and charged with R-410A refrigerant REFRIGERANT COMPONENTS and factory tested prior to shipment.All unit wiring shall be both numbered and color coded.The cooling Compressors: performance shall be rated in accordance with DOE and AHRI test procedures. Units shall be CSA certified to a. Shall be fully hermetic type,direct drive, internally ANSI Z21.47 and UL 1995/CAN/CSA No.236-M90 protected with internal high-pressure relief and over standards. temperature protection.The hermetic motor shall be suction gas cooled and have a voltage range of+or UNIT CABINET —10%of the unit nameplate voltage. Unit cabinet shall be constructed of galvanized steel with b. Shall have internal spring isolation and sound exterior surfaces coated with a non-chalking, powder muffling to minimize vibration and noise, and be paint finish, certified at a 750-hour salt spray test per externally isolated on a dedicated, independent ASTM-B117 standards. Indoor blower sections shall be mounting. insulated with up to 1"thick insulation coated on the airside. Either aluminum foil faced or elastometric rubber Coils: insulation shall be used in the unit's compartments and be fastened to prevent insulation from entering the air stream. Cabinet doors shall be hinged with toolless access for easy servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment,overhead rigging,fork truck access and proper sealing on roof curb applications. Disposable 2"filters shall be furnished as standard and be accessible through hinged access door. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without Information is subject to change without notice.Check local codes. Printed 08/11/2022 PORK® Guide Specification for Page:33 York® Sun TM Pro a. Evaporator coils shall have aluminum plate fins Heat exchanger and exhaust system shall be mechanically bonded to seamless internally enhanced constructed of aluminized steel, and be designed with copper tubes with all joints brazed. Special Phenolic induced draft combustion with post purge logic, energy coating shall be available as a factory option. saving direct spark ignition, and redundant main gas b. Evaporator coils shall be of the direct expansion, draw- valve. The heat exchanger shall be of the tubular type, thru design. constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering c. Condenser coils shall have aluminum plate fins temperature of 40°F. Burners shall be of the in-shot mechanically bonded to seamless internally enhanced type, constructed of aluminum-coated steel.All gas copper tubes with all joints brazed or Micro-Channel piping shall enter the unit cabinet at a single location, aluminum tube, aluminum fins. through either the side or bottom,without any field d. Condenser coils shall be of the draw-thru design. modifications.An integrated control board shall provide timed control of evaporator fan functioning and burner Refrigerant Circuit and Refrigerant Safety Components ignition. Heating section shall be provided with the shall include: following minimum protection: a. Independent fixed-orifice or thermally operated a. Primary and auxiliary high-temperature limit switches. expansion devices. b. Induced draft pressure sensor. b. Solid core filter drier/strainer to eliminate any moisture c. Flame roll out switch (manual reset). or foreign matter. d. Flame proving controls. c. Accessible service gage connections on both suction e. All two stage gas units shall have two independent and discharge lines to charge, evacuate, and measure stages of capacity(70% or 75% 1st stage, 100%2nd refrigerant pressure during any necessary servicing or stage)3 through 5 ton and (60% 1st stage, 100% 2nd troubleshooting, without losing charge. stage)6-1/2 through 12-1/2 ton. d. The unit shall have two independent refrigerant circuits, equally split in 50% capacity increments. UNIT OPERATING CHARACTERISTICS Unit Controls: Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria a. Unit shall be complete with self-contained low-voltage of AHRI Standard 340/360.The compressor,with control circuit protected by a resettable circuit breaker standard controls, shall be capable of operation down to on the 24-volt transformer side. 0°F outdoor temperature. Unit shall be provided with fan b. Unit shall incorporate a lockout circuit which provides time delay to prevent cold air delivery before heat reset capability at the space thermostat or base unit exchanger warms up. (Gas heat only) should any of the following standard safety devices trip and shut off compressor: ELECTRICAL REQUIREMENTS-All unit power wiring • Loss-of-charge/Low-pressure switch. shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry to • High-pressure switch. minimize roof penetrations and avoid unit field • Freeze condition sensor on evaporator coil. If any modifications. Separate side and bottom openings shall of these safety devices trip,the LCD screen will be provided for the control wiring. display the alarm message. STANDARD LIMITED WARRANTIES-Compressor—5 c. Unit shall incorporate"AUTO RESET"compressor Years, Heat Exchanger— 10 Years, Elect. Heat Elem.—5 over temperature, over current protection. Years, Parts—1 Year. d. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy FACTORY INSTALLED OPTIONAL OUTDOOR AIR hook-up. (Shall be made available by either/or): e. Unit control board shall have on-board diagnostics and fault message display. ADDITIONAL FACTORY INSTALLED OPTIONS f. Standard controls shall include anti-short cycle and low • Alternate Indoor Blower Motor—For applications voltage protection, and permit cooling operation down with high restrictions, units are available with optional to a selectable value as low as 0°F. indoor blower motors that provide higher static output g. Control board shall monitor each refrigerant safety and/or higher airflow. switch independently. GAS HEATING SECTION Information is subject to change without notice.Check local codes. Printed 08/11/2022 yoRK® Guide Specification for Page:34 York® Sun TM Pro • IntelliSpeedTM Supply Fan Control Option (ASHRAE 90.1 compliant,section 6.4.3.10)—Units configured with the IntelliSpeedm1 Supply Fan Option will contain a VFD for variable volume supply fan operation.This option allows the supply fan RPM to vary based on the number of compressors or heating stages energized.The economizer's minimum position will also be configurable to vary based on the supply fan VFD frequency output. • BAS Controls—Include supply air sensor, return air sensor, dirty filter indicator and air proving switch. • Stainless Steel Heat Exchanger—For applications in a corrosive environment,this option provides a full stainless steel heat exchanger assembly. FIELD INSTALLED OPTIONS • Roof Curb—14"high,full perimeter knockdown curb, with hinged design for quick assembly. Information is subject to change without notice.Check local codes. Printed 08/11/2022 Page:35 Date 08/11/2022 Project Name GARVEY HYUNDAI F.W WEBB COMPANY Project Number Client/Purchaser Control Summary Page Control Models and Unit Tags (Standard Simplicity Control ZJO90S18R2D1AAD1A2 ENCLOSED SERVICE DRIVE ZJO78S18P2D1AAA1A2 WASH/DETAIL BAYS Information is subject to change without notice.Check local codes. Printed 08/11/2022 PORK® SSE Guide Spec Page:36 23 09 23 Direct-digital Control system for HVAC 23 09 23. 13 Decentralized,Rooftop Units: 23 09 23. 13.A. Unit Control Board 1. ASHRAE 62-2001compliant. BTL certified. 2. Shall accept 20-30 VAC input power,50/60Hz. 24 VAC nominal. 3. Operating temperature range from-40F to 158F; 10-90%RH(non-condensing UI),and-4F to 158F; 10-90%Rh(non- condensing),with a storage temperature range from-40F to 194F;5-95%RH(non-condensing). 4. Shall include an option of and Economizer microprocessor controller which communicates directly with the Unit Control Board and has 8 Analog outputs,2 Analog inputs,2 Binary outputs,3 Binary outputs. 5. Controller shall accept the followinginputs:space temperature,return air temperature sensor,setpointadjustment,outdoor air temperature,indoor air quality,outdoor air quality,indoor relative humidity,compressor lock-out,fire/smoke shutdown,single and dual enthalpy,fan status,remote time clock,SA Bus communicated temperature/humidity/CO2 values from Network sensors, FC Bus Network Overrides for space temperature,outdoor air temperature,space humidity,outdoor air quality,Indoor air quality, System purge. 6. Shall accept a single CO2 sensor or multiple CO2 sensors networked together via communication bus in the conditioned space,and be Demand Control Ventilation(DCV)ready. 7. Shall provide the following outputs:economizer,fan,cooling stage 1,cooling stage 2,heat stage 1,heat stage 2,heat stage 3/ exhaust/reversing valve/dehumidify/occupied. 8. Unit shall provide surge protection for the controller through a circuit breaker. 9. Shall be Internet capable,and communicate at a Baud rate of 38.4K or faster. 10. Shall have an LED display independently showingthe status of activity on the communication bus,and processor operation. 11. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit should any of the following standard safety devices trip and shut off compressor. If any of these safety devices trip,the LCD screen will display alarm message indicating the specific safety device that caused the lockout. a. Loss of charge/Low-pressure switch. b. High-pressure switch. c. Freeze condition sensor on evaporator coil. 12. Unit control board must support each usage case: a. Conventional thermostat with low voltage input terminals for easy installation b. Communicating network sensors in the occupied space to provide feedback on space conditions for unit control board to compare with associated setpoints c. Communication via BACnet MS/TP, Modbus RTU, N2 protocols for integration into a building automation/management system 13. Anti-short cycle and low voltage protection features included. 14. Internal occupied/unoccupied scheduling 15. Unit control board shall permit cooling operation down to a selectable value as low as 0 degrees F. 16. Shall allow for start-up, commissioning,troubleshooting,parameter adjustment,setpoint adjustment via onboard display and navigable menu with no additional interface tool or controls technician required. 17. The unit control board shall run a self-test diagnostics algorithm at startup that operated the cooling cycle,heating cycle,fan operation.A status report shall be provided upon completion of the diagnostic self-test. 18. Utilize any wi-fi enabled smart device to access the HVAC or multiple HVAC units if communication wiring between them is present(FC Bus or SA Bus).Remote access shall allow complete ability to perform start-up, commissioning, troubleshooting,parameter adjustment,setpoint adjustment. 19. Local embedded trending and scheduling.Trending data and occupancy scheduling predefined from the factory. Occupancy schedule to be modified via control board joystick menu navigation and remotely using a smart device (cellular phone,laptop,tablet) 20. A menu on the onboard screen shall display the unit status and allow changing parameters where applicable.These include but are not limited to: a. Demand Ventilation Mode—enable or disable b. Operational Setpoint—display current value c. Supply Air Temperature(SAT)—display current value d. Return Air Temperature(RAT)—display current value Information is subject to change without notice.Check local codes. Printed 08/11/2022 PORK® SSE Guide Spec Page:37 e. Operational Supply Humidity(OprSH)—display current value as provided by a 0-10VDS input,SA Bus Network Sensor,or FC Bus communicated value f. Return Air Humidity(RAH)—display current value g. Operational outdoor Air Temperature(OprOAT)—enthalpy calculated from OAH 0-10VDC input to Economizer board and OprOAT only if economizer is present h. Operational Outdoor Air Humidity(OprOAH)—the buffered outdoor air humidity.May be from economizer boards OAH 0-10VDC input or FC Bus communicated value i. Operational outdoor Air Quality(OprOAQ)—the buffered outdoor air quality in use. May be from economizer boards OAQ 0-10VDC input or FC Bus communicated value j Operational Indoor Air Quality(OprIAQ)—the buffered indoor air quality in use.May be from economizer board IAQ 0-10VDC input,SA Bus Network Sensor,or FC Bus communicated value 21. A menu shall display and allow modification to the following operations and settings: a. HVAC Zone Fan b. Cooling c. Heating d. Economizer e. Demand Ventilation f. Power Exhaust g. Sensors h. Network 22. A menu shall display and allow modification to the following operations and settings: a. HVAC Zone—Occupied status b. Indoor Fan status c. Cooling status d. Heating status e. Economizer indication whether free-cooling is available or not f. Enabling or disabling of Demand Ventilation g. Power Exhaust 1) Enable/disable hot-gas reheat if available 2) Warmup/Cooldown 3) Title 24 Load Shed 4) Defrost 23. A menu shall display and allow modification to the following operations and settings: a. Firmware version(of UCB, Economizer,other peripheral boards) b. Setting time zone c. Network information 1) Device name that will appear on the FC Bus 2) Selection of communication protocol 3) Operational Baud Rate 4) Device ID 24. A menu shall display and allow modification to the following operations and settings: a. Version of firmware b. Ability to Load new firmware c. Create a backup file of the firmware and parameter setting via USB port d. Restore factory default parameter values and setup e. Full and Partial Cloning of parameter setpoints from or to other units f. Data trend exporting 25. A menu shall display and allow modification to the following operations and settings: Information is subject to change without notice.Check local codes. Printed 08/11/2022 YORK® SSE Guide Spec Page:38 a. Unit serial number,model number and name b. Ability to reset Lockouts c. Controller name d. Displays the current values of all setpoints in use e. Displays all current values for the indoor and outdoor zones f. Displays current values related to: 1) Indoor Fan 2) Cooling 3) Heating 4) Heat Pump operation 5) Economizer operation 6) Power Exhaust 7) Demand Ventilation 8) Air monitoring station 9) Hot Gas Reheat 10) Smoke Control g. Current information for inputs;including 1) Sensors 2) Coil Sensors 3) Thermostat 4) Binary Inputs 5) Unit Protection 6) Network Inputs 7) All outputs(relay and binary) h. Self-Test 1) A patented self-test system that runs through a series of algorithms to provide a report of all functioning characteristics of the system at time of startup and commissioning. 23 09 23. 13.B. Auxiliary Control Boards 1. ASHRAE 62-2001 compliant. BTL certified. 2. Economizer controller CEC Title 24 Compliant a. Display alarms if the following occur 1) Economizer is economizing when conditions do not support 2) Economizer is not economizing when conditions do support 3) Damper Stuck 4) Excess Outdoor Air 5) Failed Sensor 3. Refrigeration Fault Detection&Diagnostics a. There is insufficient refrigerant in any circuit b. There is excessive refrigerant in any circuit c. There is excessive refrigerant flow d. There is insufficient refrigerant flow(restriction) e. Inefficient compressor f. Insufficient High-side heat transfer g. Excessive High-side heat transfer(low ambient control problem,low AP) h. Insufficient Low-side heat transfer i. Excessive Low-side heat transfer Information is subject to change without notice.Check local codes. Printed 08/11/2022 PORK® SSE Guide Spec Page:39 j. Sensor fault-The liquid temperature is greater than the condenser temperature(Could also be triggered if refrigerant level is very low in the system) k. Sensor fault-Sensor data is not available I. The unit is off m. The ambient temperature is too low n. The ambient temperature is too high o. The return air wet-bulb temperature is too low p. The return air wet-bulb temperature is too high q. Sensor fault-The condensing temperature is lower than the ambient temperature(Could also be triggered when the condenser is wet) r. The suction line temperature is less than the evaporator temperature s. The evaporator temperature is greater than the ambient temperature t. The liquid temperature is lower than the ambient temperature u. Sensor fault-Suction temperature or ambient temperature is invalid v. Sensor fault-The return air dry-bulb or wet-bulb temperature is invalid w. Sensor fault-The liquid pressure or suction pressure is invalid x. Sensor fault-The suction line temperature is invalid y. The return air dry-bulb temperature is too low z. The return air dry-bulb temperature is too high aa. The Efficiency Index is below 75%of ideal bb. The Capacity Index is below 75%of ideal 23 09 23. 13.0 Remote Accessibility: 1. ASHRAE 62-2001 compliant. BTL certified. 2. Provide the ability to adjust parameter values,setpoints,limits remotely 3. Connectivity to an Ethernet network via static IP address or Dynamic Name Server(DNS) 4. Allow a maximum of 100 devices on the same FC bus trunk and accessed by one remote device Information is subject to change without notice.Check local codes. Printed 08/11/2022 Page:40 START-UP & SERVICE DATA INSTRUCTION COMMERCIAL PACKAGE UNITS 3.0 To 40.0 TONS START-UP CHECKLIST Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician: Signature: HVAC Contractor: Phone: Address: Contractor's E-mail Address: Electrical Contractor: Phone: Distributor Name: Phone: WARRANTY STATEMENT This start-up sheet covers all startup check points common to all package equipment.In addition it covers essential startup check Johnson Controls/UPG is confident that this equipment will points for a number of common installation options.Depending operate to the owners satisfaction if the proper procedures are upon the particular unit being started not all sections of this startup followed and checks are made at initial start-up.This confidence is sheet will apply.Complete those sections applicable and use the supported by the 30 day dealer protection coverage portion of our notes section to record any additional information pertinent to your standard warranty policy which states that Johnson Controls/UPG particular installation. will cover parts and labor on new equipment start-up failures that Warranty claims are to be made through the distributor from whom are caused by a defect in factory workmanship or material,for a the equipment was purchased. period of 30 days from installation.Refer to current standard warranty policy and warranty manual found on UPGnet for details. EQUIPMENT STARTUP In the event that communication with Johnson Controls/UPG is required regarding technical and/or warranty concerns,all parties Use the local LCD or Mobile Access Portal(MAP)Gateway to to the discussion should have a copy of the equipment start-up complete the start-up. sheet for reference.A copy of the original start-up sheet should be A copy of the completed start-up sheet should be kept on file filed with the Technical Services Department. by the distributor providing the equipment and a copy sent to: The packaged unit is available in constant or variable air volume Johnson Controls/UPG versions with a large variety of custom options and accessories Technical Services Department available.Therefore,some variation in the startup procedure will 5005 York Drive exist depending upon the products capacity,control system, options and accessories installed. Norman,OK 73069 Information is subject to change without notice.Check local codes. Printed 08/11/2022 Page:41 SAFETY WARNINGS The inspections and recording of data outlined in this procedure AWARNING are required for start-up of Johnson Controls/UPG's packaged Lethal voltages are present during some start-up products.Industry recognized safety standards and practices checks.Extreme caution must be used at all times. must be observed at all times.General industry knowledge and experience are required to assure technician safety.It is the responsibility of the technician to assess.all potential dangers and take all steps warranted to perform the work in a safe A�A�■1fARNING manner.By addressing those potential dangers,prior to beginning any work,the technician can perform the work in a safe manner with minimal risk of injury. Moving parts may be exposed during some startup checks.Extreme caution must be used at all times. NOTE: Read and review this entire document before beginning any of the startup procedures. DESIGN APPLICATION INFORMATION This information will be available from the specifying engineer full open position`and the frequency drive is operating at 60 HZ. who selected the equipment.If the system is a,VAV system the Do not proceed with the equipment start-up without the CFM will be the airflow when the remote VAV boxes are in the design CFM information. Design Supply Air CFM: Design Return Air CFM: Design Outdoor Air CFM At Minimum Position: Total External Static Pressure: Supply Static Pressure: Return Static Pressure: Design Building Static Pressure: Outside Air Dilution:Economizer Position Percentage: _CFM:. Supply Gas Pressure After Regulator W/o Heat Active Inches _ ADDITIONAL APPLICATION NOTES FROM SPECIFYING ENGINEER: Information is subject to change without notice.Check local codes. Printed 0 8111/2 0 2 2 Page:42 REFERENCE General Inspection Completed See Notes Unit inspected for shipping,storage,or rigging damage ❑ ❑ Unit installed with proper clearances 0 0 Unit installed within slope limitations ❑ 0 Refrigeration system checked for gross leaks(presence of oil) 0 0 Terminal screws and wiring connections checked for tightness ❑ 0 Filters installed correctly and clean ❑ ❑ Economizer hoods installed in operating position 0 ❑ Condensate drain trapped properly,refer to Installation Manual ❑ 0 Economizer damper linkage tight ❑ 0 Gas Heat vent hood installed 0 0 All field wiring(power and control)complete ❑ 0 Air Moving Inspection' Completed See Notes Alignment of drive components 0 ❑ Belt tension adjusted properly 0 ❑ Blower pulleys tight on shaft,bearing set screws tight,wheel tight to shaft ❑ 0 Pressure switch or transducer tubing installed properly 0 ❑ Exhaust Inspection Powered 0 Barometric Relief 0 Completed See Notes Check hub for tightness 0 0 Check fan blade for clearance 0 0 Check for proper rotation 0 0 Check for proper mounting(screen faces towards unit) ❑ 0 Prove operation by increasing minimum setting on economizer ❑ 0 Economizer Inspection Standard 0 BAS 0 Completed See Notes CO2 sensor installed Yes 0 No 0 0 0 Check economizer setting(Reference SSE Control Board LCD menu location) 0 0 Prove economizer open/close through SSE Board Setting 0 0 Reheat Mode Normal 0 or Alternate❑ Not Applicable❑ Humidity Sensor(2SH0401) Information is subject to change without notice.Check local codes. Printed 08/11/2022 Page:43 Operating Measurements -Air Flow Fan operates with proper rotation ID Fans 0 Exh.Fans 0 Cond.Fans 0 Pressure drop across dry evaporator coil(At maximum design CFM)1 IWC External Static Pressure IWC Return Static Pressure IWC Supply Static Pressure IWC Supply Air CFM Using Dry Coil Chart CFM Final Adjusted Supply Air CFM2 CFM 1. Consult the proper airflow to pressure drop table to obtain the actual airflow at the measured pressure.differential. 2. Was a motor pulley adjustment or change required to obtain the correct airflow? Was it necessary to increase of decrease the airflow to meet the design conditions? If the motor pulley size was changed,measure the outside diameters of the motor and blower pulleys and record those diameters here; Blower Motor HP FLA RPM Pulley Pitch Diameter Turns Out Final Turns Out Blower Pulley Pitch Diameter Fixed Sheave ELECTRICAL DATA T1 -T2 • Volts T2-T3 Volts Control Voltage Volts T1 -T3 Volts Device Nameplate Measured List All Three Amperages Supply Fan Motors.2 AMPS AMPS Exhaust Motor(Dampers 100%) AMPS AMPS Condenser Fan#1 AMPS AMPS Condenser Fan#2(if equipped) AMPS AMPS Condenser Fan#3(if equipped) AMPS AMPS Condenser Fan#4(if equipped) AMPS AMPS Compressor#1 AMPS AMPS Compressor#2(if equipped) AMPS AMPS Compressor#3.(if equipped) AMPS AMPS Compressor#4(if equipped) AMPS .AMPS 1. VAV units with heat section-simulate heat•call to drive VAV boxes.and VFDIGV to maximum design airflow position. 2. VAV units without heat section-VAV boxes must be set to maximum design airflow position. Information is subject to change without notice.Check local codes. Printed 08/11/2022 Page:44 OPERATING MEASUREMENTS -COOLING DischaSuction Stage Pressure e Discharge Temp. Liquid Line SubcoolingZ PressSuctuon re Temp. Superheat First # ° 0 # ° Second(if equipped) # 0 # ° Third(if equipped) # ° 0 # ° Fourth(if equipped) # # ° Reheat 1st Stage # 0 0 0 # 00 1. Liquid temperature should be taken before filter/drier. 2. Subtract 10 psi from discharge pressure for estimated liquid line pressure Outside air temperature .°F db °F wb %RH Return Air Temperature °F db °F wb, %RH Mixed Air Temperature °F db °F wb %RH Supply Air Temperature °F db °F wb %RH REFRIGERANT SAFETIES Action Completed See Notes Prove Compressor Rotation(3 phase only)by gauge pressure ❑ ❑ Prove High Pressure Safety,All Systems 0 ❑ Prove Low Pressure Safety,All Systems 0 0 OPERATING MEASUREMENTS -GAS HEATING Fuel Type: 0 Natural Gas 0 LP Gas Action Completed See Notes Check for gas leaks 0 O. Prove Ventor Motor Operation 0 0 Prove Primary Safety Operation ❑ ❑ Prove Auxiliary Safety Operation 0 ❑ Prove Rollout Switch Operation 0 ❑ Prove Smoke Detector Operation ❑ 0 Stage 1 IWC 0 Manifold Pressure Stage 2(If Equipped) - IWC 0 Stage 3(If Equipped) IWC ❑ Supply gas pressure at full fire IWC 0 Check temperature riser 0 measured at full fire °F 0 t, Input X Eff.(BTU output) 1.08 X Temp.Rise Information is subject to change without notice.Check local codes. Printed 08/11/2022 Page:45 OPERATIONAL MEASUREMENTS -STAGING CONTROLS Verify PrOper Operation of Heating/Cooling Staging Controls Create a cooling demand at the Thermostat,BAS System or Simplicity SE Verify that cooling/economizer stages are energized. ❑ Create a heating demand at.the Thermostat,BAS System or Simplicity SE Verify that heating stages are energized. ❑ Verify Proper Operation of the Variable Frequency Drive(If Required). Verify that motor speed modulates with duct pressure change. I ❑ FINAL -INSPECTION Verify that all operational control set points have been set to desired value ❑ Scroll through all setpoints and change as maybe necessary to suit-the occupant requirements. Verify that all option parameters are correct Scroll through all option parameters and ensure that all installed options are enabled in the software,and all ❑ others are disabled in the software.(Factory software settings should match the installed options) Verify that all access panels have been closed and secured ❑ OBSERVED PRODUCT DIFFICIENCIES 8,CONCERNS: Information is subject to change without notice.Check local codes. Printed 08/11/2022 � ® KNIGHT 14ocJjjjivaj FIRE TUBE BOILER HIGH EFFICIENCY BOILERS &WATER HEATERS Submittal Sheet KHBWHB-Sub-02 KNIGHT FIRE TUBE BOILERS - FLOOR AND WALL MOUNT MODELS Job Name: Location: - Engineer: Agent/Wholesaler: Contractor: Type Gas: {�/ i�rf rL Model it: Equipment Tag(s): al_� doe NOTES: > Four Pump Control r•_ System Pump with Parameter for Continuous Operation '. Boiler Pump with Variable Speed Control Domestic Hot Water Pump Domestic Hot Water Recirculation > Domestic Hot Water Prioritization DHW tank piped with priority in the boiler loop DHW tank piped as a zone in the system with the pumps controlled by the SMART SYSTEM DHW Modulation Limiting o-10 VDC BMS External Control Contact Separately Adjustable Space Heat/DHW o-io VDC Boiler Rate Output Contacts Smart System Features Switching Times 0-10 VDC Variable Speed System Pump Signal Input > Building Management System Integration 0-10 VDC Signal to Control Variable Speed Boiler Pump > Smart System Digital Operating Control o-lo VDC Input to Control Modulation or Setpoint Modbus Contacts Multi-Color Graphic LCD Display w/Navigation Dial, o-lo VDC Modulation Rate Output p > Time Clock Soft Keys and Loch-N-Link USB programming o-10 VDC Input to Enable/Disable Call for Heat > Three Boiler Setpoint Temperature Inputs > Data Logging > Access to BMS Settings through Graphic LCD Hours Running,Space Heating Plus Domestic Hot Water Prioritization Di• splay Hours Running,Domestic Hot Water > Built-in Cascading Sequencer for up to > High-Voltage Terminal Strip Ignition Attempts 8 Boilers,with Cascade Redundancy 12o VAC/6o Hertz/i Phase Power Supply Last io Lockouts Multiple Size Boiler Cascade Three Sets of PumpContacts Lead Lag ) Maintenance Reminder Efficiency0ptimization > Low-Voltage Terminal Strip Custom Maintenance Reminder with Front End Loading Capability DHW Recirculation Pump Start/Stop Contractor Contact Information 24 VAC Device Relay Installer Ability to De-activate Service > Outdoor Reset Control with Outdoor Air Sensor Configurable Proving Contacts Reminder Programmable for Three Reset Temperature Inputs Flow Switch Contacts > Programmable System Efficiency Optimizers Alarm on Any Failure Contacts > Low-Water Flow Safety Control&Indication SH Night Setback Runtime Contacts > Password Security DHW Night Setback DHW Thermostat Contacts > Customizable Freeze Protection Parameters Anti-Cycling 3 Space Heat Thermostat Contacts Outdoor Air Reset Curve System Sensor Contacts Ramp Delay DHW Tank Sensor Contacts Optional Equipment Modulation Factor Control Outdoor Air Sensor Contacts ❑CON•X-US Remote Connectivity Boost Temperature&Time Cascade Contacts ❑Modbus Communication ❑BACnet MSTP Standard Features 0 Flow Switch ) 95%DOE AFUE Efficiency(55-285) > SMART SYSTEMT"'Control ❑Low-Water Cutoff w/Manual Reset&Test > Modulating Burner with up to so:z Turndown > Condensate Trap ❑Alarm Bell Direct Spark Ignition > ECM Variable Speed Boiler Circulating Pump ❑Concentric Vent Kit Low NOx Operation ❑Condensate Neutralization Kit > ASME Stainless Steel Heat Exchanger > noV Convenience Outlet 3o PSI ASME Relief Valve > High Altitude Models Available ❑BMS Gateway to LON or BACnet IP > Top and bottom water connections(MNPT, > Other Features El Multi-Temperature Loop Control Automatic Reset High Limit ❑Sidewall Vent Termination WHB 55-285 Only) Wireless Outdoor Sensor > Vertical&Horizontal Direct Vent Adjustable High Limit w/Manual Reset ❑ PVC,CPVC,Polypropylene orSSVenting up to loo ft. Zero Clearances to Combustible Materials ElLP Gas Conversion Kit > Universal Vent Adapter 15-Year Limited Warranty(See Warranty for Details) > Firing Codes Built-in Combustion Analyzer Port 5-Year Limited Parts Warranty ❑M9 Standard Construction • ® FRONT LEFT SIDE 1tBHT �G �'FIRE TUBE BOIL t cill Water Outlet I Gas Inlet III Vt , - L 4 • - - - TOP01; - -1 D i-- Flue Vent Water Inlet AC High Voltage Outlet O Electrical I1 I' '‘" A 43.3/8" ... ® Connection i C/:t), -i I o -��� I- Low Voltage ----Q ((III 19" - - CEle onnection F Condensate o Ta El°o I 1 ` Drain K =� { . 16" L H -'I I (FLOOR MOUNT ^• CERTIFIED` I Input MBH Net Heating AHRI Shipping Model Capacity Rating Gas Water Air Vent Weight Number Min Max AFUE% MBH MBH A B C D E F G H I J K Conn. Conn. Inlet Size (lbs.) VI KHB055N B.3 55 95 51 44 3.1/2" 13.1/4° 6" 2-3/4° 37-2/3" 13-1/2" 8-1/3" 10.1/2" 15° 32.1/2' 8.1/3" 1/2° 1° 2" 2° 160 yc KHB085N 8.5 85 95 79 69 3-1/2° 13.1/4" 6" 2-3/4" 37-2/3" 13-1/2° 8.1/3" 10.1/2' 15' 32.1/2' 8.1/3' 1/2" 1" 2° 2° 165 Qf K118110N 11 110 95 102 89 2-3/4" 14-3/4" 7-1/2° 2.3/4" 38" 14.1/3" 9.3/4" 10.1/2' 15' 33° 8-1/3' 1/2° 1° 3° 3" 170 l?f K11815511 15.5 155 95 143 124 2.3/4" 14.3/4" 7.1/2° 2.1/2° 38" 14-1/3° 9-3/4" 10-1/2' 15' 33' 8-1/3' 1/2" 1° 3" 3' 175 lrj K1181990 19.9 199 95 184 160 3° 15.1/2° 7-1/2" 2-1/2" 38-1/3" 14-1/3' 10-1/2° 11.1/2' 15' 33' 8•1/3" 1/2° 1.1/4" 3° 3' 195 a KHB2B5N 28.5 285 95 164 230 3" 15.1/2" 7.1/2" 2.1/2" 38.1/3" 14-1/3• 10-1/2" 11-1/2' 15" 33' 8-1/3' 1/2" 1.1/4" 3° 3° 205 •Information subject to change without notice.•Dimensions shown are approximate and should not be used for construction purposes.•Change"N"to"L"for LP gas models. •The Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15.•Lochinvar should be consulted before selecting a boiler for installations having unusual piping and pickup requirements,such as intermittent system operation,extensive piping systems,etc.•The ratings have been determined under the provisions governing forced draft burners. RIGHT SIDE °� TOP High Voltage BOTTOM =t t rH�i F Flue Vent Electrical Connection taw Voltage _ Electrical Connector • I Air Intake ---- • - Water Inlet �..a AC Outlet s�=r�� I 000 ® 00• I E I• I M ilir i - to` IF . D I 1 I' 1 --r J' I Condensate Drain G - - I l -aIIIIIIIIIIII L y Gas Inlet •ti . I t B M M . N Water Outlet I 1i L WALL MOUNT AnilCERTIFIED° C Input MBH Net AIM g ae ae. Rating, e = Ship Model *Output Water, o'E. 1 8= Gas Water Air Vent WI. Number Min Max MBH MOH AFUE,% ""' "' A B C D E F G H I I K I. M N Conn. Conn. Inlet Size (lbs.) Q 88055N 8.3 55 51 44 95.0 - 40° 18-3/4" 16" 31-1/8" 8-1/2" 3-3/4" 4-1/2" 6-1/2" 7-1/4" 8-7/8" 3-1/2° 1-1/2" 1-1/2" 6" 1/2" 1" 2" 2° 139 Q1lWHB_085N8.5 85 79 69 95.0 - - 39.3/4' 18-3/4' 16' 31-1/8' 8-1/2" 3-3/4" 4-1/2' 6-1/2" 7-1/4' 8-7/8" 3-1/2' 1-1/2' 1-1/2° 6' 1/2' 1' 2' 2' 142 Q(9tWH8110N 11 110 102 89 - 95.0 - - r 41-1/4" 18.3/4"-19' 31-1/8" 10"-- 2-3/4' 5" 5.1/4' 11-1/2" 8-1/2' 5" 1' 1' 4:1/2' 1/2' 1' 3" 3" 159 al/1WH8155N 15.5 155 144 125 95.0 - - - • 41-1/4' 18-3/4'-19-1/8' 31-1/8' 10' 2-3/4' 5' 5-1/4' 11-1/2' 8-1/2' 5' 1' 1' 4-1/2' 1/2' 1' 3' 3' 166 091WHB199N 19 9 199 184 160 95 0 - - 1 41-1/4' 18-3/4' 19-1/8" 31-1/8' 10-1/7' 3' 5-1/4" 6• 11' 9-1/2' 6-1/4'1-1/2' 1-1/2' 4S/2" 1/2' 1:1L4" 3' 3' 175 -919IHB285N 28.5 285 264 230 95 0 - - • 41-3/4' 18-3/4' 21-1/8' 31.1/8' 15' 3' 3.3/4' 5.1/4' 12.1/4' 11' 6-1/4'1.1/2' 1.1/2" 6-1/2' 1/2' 1-1/4' 3' 3' 184 -O-llWHB399N 39.9 399 377 328 - 96.0 94.4• 43-5/8' 25-1/4" 21-7/8" 34-3/8' 3-1/8° 4-1/4" 23" 3-7/8' 8-3/4' 12-1/2" 9-1/4'2' 2' 23' 3/4" 1-1/2" 4' 4' 213 *Top and bottom water connections are not •Information subject to change without notice.•Dimensions shown are approximate and should not be used for included on WHB399. construction purposes.•"Output"is"Heating Capacity"for units with inputs(30o MBH and"Gross Output"for units a3oo MBH.•Change"N"to"L"for LP gas models. •The Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15.• Lochinvar should be consulted before selecting a boiler for installations having unusual piping and pickup requirements,such as intermittent system operation,extensive piping systems,etc.•The ratings Lochinvar,LLC *Lochinvar® 3oo Maddox Simpson Parkway O'N \ -�iti` Lebanon,Tennessee pogo SLID' LO NOK // tit 1111 P:6t5.88g.8gao1F6t6.547.t000 - • I �) 1 I� I MEMBER ,.;,e; ,•` HIGH EFFICIENCY BOILERS&WATER HEATERS ■I©®G Lo[hI11Var.tom --- H 2/22-Printed in U.SA. • s HE HAANEN ENGINEERING Job No l ‘oc13 Sheet No. 1 of k 6 Subject: RIIA Asa) torved ky.t in 644 J.:‘• 1.-11)vt By (11- Date 0 T-1.26 I 22 atl• C,J.1 CJJISYC NYS OC 20 20 Npeck LC344- A s shtrvai‘-s Sew rele h...4 10 11, 2• 5 psi SAspeetc.le_ci Cei 4 psf- g rilLr- COPY — c,,,,,,svc 4 6.6.) (Py v-Irk cryi goo Prtkvvi 0"-3 5 S F _011 crKtd litkrtck0^3 rn RocrE 5-42S P Zt.,utD1)e-sic:yin De_ci Leaci t r P Su.ife-Ads‘_.t.A 303.15-1-3 CC-0472-2022 GARVEY SISTERS, LLC 1-43 SLtsr41,4-e.4, 257 Dix Ave Commercial Addition 8327 s.f. Roc,r 13te-5 Live L c 2 orsic ' IF\ EC EriV NEw JUL 9 8 2022 Aisc\ L _ _ _ .‘"t452744#411\ Tow'! 'Or1P77-' _BUILL'ANG_6 ‘,4 ts' r \ 0.61241 kr/ \ft/po 111,•‘:./ " FESSIO 12.610/ 254 Bay Rd - Queensbury, NY 12804- Phone:518-793-7444- Fax:518-793-7061 s Fla HAANEN ENGINEERING Job No l6tlg3 Sheet No. 2 of "lb Subject: f}S\ 0 Ctu � � (cwt.vey ('l Undue.• A-G�.c�i\-0 1 I By f `S C Date 6 f l 2-6 2-t L�JQck. 60/c,, 1iti h 3) 'R SY1o‘,J L --� esc YlIurc.1) Svc \p \ - 0 psP R„,F CY< w Luc hp 6. 7 -c,- CI_ -15 173 --�► Loh eye. C : f - Ct - I- o is = 1 0- 7 x )•OXI.oXSor,P P 35'iF. Coo F SLo,z C = 34" : )2_ Ynu-dFZh Ex t 1 h- 'o e slope_ )ritvlt2 ee_c! 7rnoP SY1 LAJ j-dc.A..a Ps = CS • bp, wk Ye_ C5 : S L® rt R jvr 2- ►,o Slope e7vJF Sn`.) Lod 3 GpSr 254 Bay Rd - Queensbury, NY 12804- Phone:518-793-7444- Fax:518-793-7061 HAANEN ENGINEERING Job No , Gn R I Sheet No. 3 of Its Subject: R1-1W PcSSUGic s By R S (a Date 0 I?26 P 2 L LL,L4 A VVGaA(i.J.Jv-Val 5 . 4) W n Loa C Ck4ektr ) As C s 9- l S/ Caw FTZS - ' we d .) \ile Li (J1�°SSVv-C C 0.00 , V4 \cd V2 \,/ „basis Win Spee_ci I f S-.s,Y, ti (<c COi d INYeti10 ;tj d s-s lLZ 2 V L 6 6- 5 a re. Co-e.P c.— i C.t e 0_ o (uY Yoe0 ytioF Ytet t t d rt- rfiod Sure. • C (fit z 'broraphic Pikcly't Ciiz z a c. 9 5ei 26 psr 254 Bay Rd - Queensbury, NY 12804- Phone:518-793-7444- Fax: 518-793-7061 • EIBIHAANEN ENGINEERING Job No 1 Gd1S Sheet No. A of 10 Subject: 12-14 A- P"SS o C'c..l S By Date 07IA-C. 12L l.o , z Ce-kc..l.o ,\a.., p. z 9, . [ x Cre) - (cir Cpi J j W11 9.Yh z 26 ?s 'coop orate 0 .,- Z ' GC P -�• O• I i5 j (s C P e _ Lk l-e ,1 i h EQ/10 w i1•4 'k h-1t i 16u kSkNe.3 SMIle0Ce CCPe a. Cp; Nlefi 0re,cs�o--t, ( PS 1 0. 4 0 — c)•1s IS. I 2 - b, GI -1- 6 .1W - 2Z. ‘ 3 - 0 .37- 6 . tc‘ — l4. 3 Li — 0 - Zq -I- G. 1c‘ _ 12. L2 I E 6 . GI o , 1tic +20 , 2C a 1. 03- 4- 6. 1CS — 32• S 3 6 - 0 . 63 -k-o .l&< - Ir-S. 46 — 0 , G3 .4- 0- \ - 16 . 254 Bay Rd Queensbury, NY 12804- Phone:518-793-7444- Fax:518-793-7061 HEHAANEN ENGINEERING Job No lG °9 3 Sheet No. 5 of to Subject: ' -1-tPr Pnc o c t>_..4-et , &c Ve.3 H jurdui Melk h)O%1 By I"`5 k Date 6 3-1 2 6 I ZL U.o(AA (bi.„� 0,,n, 1-(-e ACC) hv4 g . u !pi P4- cJ- Ey.J.s . 3 a-S e s f r&c.tx u' LiY4 at- 4-t: for me p b,(k.6 nn = Z 2-6 42Sf \ t c Case — C3 I3u6 A SA YPuce CIPG. Cr% Neil- t� ,ka ra re,A k�-e ( psP) 3 , ltS — 0 , 1 " • 6, 4 2 — a -C9 + 0,tcL — 22-6 3 - V -34 i6- tce — 14. 3 4 _ o - 4 - -t o . lY - 16. 4 5 G, Leo — o,lts lS- I G. 0-29. 6 . 1K - 12-3 I _ o-G8' 0 . kw — I3- 24 — I -o + o. l — 32-s 3L — 6 'S3 -I- 6. IS( —kcc-C lyi. 6 - G —4- (N• W — I�- 254 Bay Rd - Queensbury, NY 12804- Phone:518-793-7444- Fax:518-793-7061 HEHAANEN ENGINEERING Job No V G ° 53 Sheet No. 6 of .o Subject: R-R Pt A'J So ci chi.S Cs<GYvej k ld1-.(lai By )'tS Date 6'0 LC 12L LOCI A, CCA CiAlOirCarIS 5 E 6,6 I _ o, [5( 6E — 6'G3 6• t5 — 1s-9 4-k C vI c e _ c- ( hry;z. 10 / )( 25 F} c o . G h = 6 . 4 x 2+F4- 2. is e� 64- 1rt4k- e d1 .2 5P4— 2 I Pq- Us a,= 3f 2ctz- pk IJt,-)e SIle_CAY in ('Yowc- Gf--� x I"3pi- X (2.a-6pif)t- (I3 x x ls• I Ps P) -r 3 .6 , k;rs 39 . k‘'es- \ht S r �u,a L o f c,es 254 Bay Rd - Queensbury, NY 12804- Phone:518-793-7444- Fax: 518-793-7061 • Fla HAANEN ENGINEERING Job No l6 d't 3 Sheet No. $ of Subject: H R- f1-3,io ciiJ-_S Crc_t rve3 A-AA .)gbh By j't S Date e?"1"-C I2-'L r,,lLanbr �- \) (� Ffi x I ;F+ x 20 .600 -f- ( I G q P+ x -x 1 si l lose) -2. 11'1‘ps 21 3 • " .45 . k-ips L ewe -z 'e ac l' h'01 is iv., -Orlrec siz1 e o f g—x\S}�lg 10usk A3-i)-`63 4,juilj,1� f- e (d" VJ - 10 << 1rYt°S a F 4-1n t •J: v\ 1/0 u G CJ 41i e.4 p'OSPc_ kb w�G� WI6 k C \Ce.) UYI`j ?CM\-i C �v� C Jo a c-3:4 h C. su n r me w Pyu vv,,),,q e.vvl ev,\- N r S w Cecl en.tmt_ ‘Ts p.),01iUe_A. PuY W W c1 i s h`oh IAQ J J fvy‘e_ 6 19 m.., d . 254 Bay Rd - Queensbury, NY 12804- Phone:518-793-7444- Fax: 518-793-7061 HEHAANEN ENGINEERING Job No 0 6 t g 3 Sheet No. Ce of \. Subject: RH S cill.•k-Pj By S (( Date 6?-11-612Z �vu (u-G"c "A'lkcj 55) Sec l,na G. a-I c\kx_55iPC ;on ���5►w+�'c �e-s►yh 96.31.+w,c keys SS = 6, 2S5 2 S s o.o Srr,5 _ Fel S _ 6, 4 S— Srh , l - S, _ o, l92 n5 2/ Sms - 0, 3 SDI 2�3 S = o. I3 �r Gtc. , you nc-1 ti,,,;. sv) cage - a. - +zAak I1 6 - , IIG - z) •� u 51 G.Q,:v J e - f a-t.e ?ro ce.c.L&rt C C kw 0 r 2 Y) 254 Bay Rd - Queensbury, NY 12804- Phone:518-793-7444- Fax:518-793-7061 • HAANEN ENGINEERING Job No 16o 0.3 Sheet No. q of Lb Subject: `. H/r A-SSo«u.,t-C acvve j kyu,1a,..; A-gji hbti By ) {.5 Date 6 3"1'4 12-Z Lc c4 C0-14.--r)-11 v^k.y Se-tSYY\;C ebe-S1cy\ S1'eo Cv, z CS , W 6.1 .61, CS ? S213M;c- Y'Q-Sk,ovti)e Co-eE'R'c SPS (t&I ) = g e-5 90w3e eert'c.t`cv' S E \ 0 y(301n-a ON Yr.e J- Pro re,c,, g 15-rv_c e A R'urwe_ Use 3 -5 r, i - b C3 o, 3 _ o .o Fib (3.5 I i-oi FF Q ci ve, J e_( S►-bn i.G ( el"1' i y' `Gl X Roo P (DcQd 1k>0.8' -+ 1 !c,10 I -ect X 0. X �tJ 1 5Y� P`oc1F Inv J + Walt Elo,30 F4-1 X igpsF) ( 000 Fir 6 '23<35 psf'� 13 3 I` es + 4ct ki'Ps -1- 2 V 14,-( a2 10 icip� 254 Bay Rd - Queensbury, NY 12804- Phone:518-793-7444- Fax: 518-793-7061 Fla HAANEN ENGINEERING Job No 166y3 Sheet No. t° of k-° Subject: R1-01. A s o - &c•v�te �-tyuv, QJ.ai htih By }'t S Date 6?-124 (it C c 3 ti S21 Srn<< 'De.Si61 bu.se SI, eav (V ) Cs - W o,o ec x 210 Ic IY) I k•‘Ps • 254 Bay Rd - Queensbury, NY 12804- Phone:518-793-7444- Fax:518-793-7061 COMPONENTS " FACETED MAIN EAM _ HD8908F08—Faceted 8°0.C::: Use for radius'15'or less .. m mica 144 I " HD8906F18-Face ted 16°0.C. Use for radius over 15'(Directional Main Beam) =12= oo o oo ° eo .. O CG'C91q OD 1'a G1C �°a J.GG�° G°IO� °C-�C__...1.___I CP__",rr.�, 4° 16 on center. 12° • MIL MAIN BEAMS Load Test Da ta * P Face rofile Duty FinewiresgRem fanber h: Di ion Hi Rated Routs mat Perspective . . 2' 3' 4' 2' 3' 4' HD8908 51 mute- starting 8D8906690 144"'.- :-1-1/2 1-11/16" Heavy Duty Yes 95.5 43.19 18.66 143.0 57.3 28.14 �a • 2-1/4"from HD84QSFtRC..' each endt v r , HD8906F08 51 •- t Routs HD8906F18 HD89061:35 :'144' 1-1/2° 1-11/16" - No 42 Routs starting 12.3 16A 2-1/4°from each ends •.Tested ed fiat per AVM C635 with RC2 clips at each faceted location :t.Type`F'?blurs compatible CROSS TEES • Load Test Data(LbsR-F) Face Profile MO U360 L/240 Item Number I Length I Dimonstar I Height I Rated I Routs wires at wires at Perspective 72" 72" • Xl.8965 72° 1-1/2° 1-1/2" No 6t6uts-starting 4.58 6.87 24 from each emit 50" 50° i i XL8947F�90 50" 1 1/2" 1 1/2° Yes 10,° 12from each emit .79 19.5 ,o r 2' 3' 4' 2' 3' 4' x 0 s ---..,,,--•:---- - e X1.8945P 9 routs- - 1 •:��� XI8945P890 48" 1-1/2' 1-1/2" Yes rout and starting 14.27 22.5 XL8945HRC 10°from each ends X17936890 36" 1-1/2" 1-120 No none 33.13 50 t Type"F°fixture compatible 4 For more information,call 1 877 276 7876 p , COMPONENTS & MOLDINGS . . . , ,, „ .- ,..:: . ir.,,, -, -, - .,,,,, - .- '.--•„. ,:,:,..:-'::-.---..:: ,,..:-,. ----_.., -:',.-::•,,.-:',,,,; CROSS TEES aliffil Load Test Data(Lbs.ILF) Poe .Profile Re U3130 U240 item Humber Length Dimension Height Hated Rinds wiles at - whoa at Perspective Z 3' 4 2' 3' 4' •' • „. • • •° „ ... 3 mob;—canto - 0 • ----,-,C:- 70.8926 • 24" 1-1t2" 1-1/2° Yes rout and 10°from 9025 158.0 (013 •-...---:,-;.?--- • . each endt . itet„.-7 t Type°P fixture compatible .____________.__.................._ _ ' : " - , -: '• - - -- -,2. . . ' - - - . ' '. WALL MOLDING _,__,,,,,,„. ,...,..„,. ,.... .. . .....,-,----,...-...--•----.....--,....-..--......----,--,..----,....... item Ili/miter WO Descrfortion Profile Perspective 7858 144" Ream Angle Wittig nominal ' 1-9/16"x 15/16" Unliumared Channel Molding nominal 7838 120° 3/4"x 1-9/16°x 1-1/4° Knurled Angle Wing nominal KAMIO 120° 11—- / 5/181,90° 1-1/4°x 1-1/4°-259 KAM12 T Knurled Angle Waling nominzi KAM12990 144° 1-atier 1-1/4°x1-1/4°-259 , KAM121010 1_. Knurled Angie Molding nominal T H14,41- .. IMM1510 1-1/2"x 1-1/2° 1-1/4' KAM1512 120° 20 tlaila KAM151020 144° 22 gags 1_ T .1=4— WM151020E4 (4MM1510&KAM1512-25g.;KAM151020-20g.; KAM151020£0-229) 1-1-1/4°---1 1-1/4' IrAM21020 Knurled Angle Molding nominal 2"x 2"(20 gaga) or 120° J__ .-------- lat21025 1 (KAA121020-20g.;ICAM21025-22 gage 2594 IfAM21020C0 22g) ...-.,.:.--• 44° 1(4121021M Of 2' LAIAI2 Locking Angle Molding naminal LAM12680 144" 1.A111211RC ' CORROSION PREVENTION AIM Corrosion prevenb'on is an essential factor in the economical utilization of galvanized sheet metal for ceiling grid. Armstrong provides 640 for Interior construction per ASTM C645.When conditions include exposure to extreme .• -::---- moisture and salt water,G00 is available per ASTM A653. ,.- -...,.. ,. ,....:...-. NOTE High Recycled Content(HRC)grid Items are available as a special order. ..... - :.:....- .-. . ...,.....,.: ... . .... ..-..-•.•..-...,...-•... ..:. . . • f..•:.,-•••-',..":-, -.-.:_-----,-::-.:-- .....;,,:-...; ..*...--.-...::.-:, . -Fot.-MOi-fy.11ifori.i)Otigji.,:talll':57,7'?7,5-'7576 5 AXIOM®:TRIM' • AXIOMO TRANSITIONS TRIM Materiel:Extudal aluminum,alloy 6063 Dem Plumber.. Description::. : , Dimensions AXTRVfSTA Straight7nuffiitiml lorVecta�:: 120 x 2-9116 x 1-11/16" 4101 .1 . . . ... :..: Mom*—Transiffixts etith Vecto welt dipal ptsf meter lAzrtIMESTiq AXIRTECIM [;erred Translbon.tr�Tegidar. 120 x 2-9/16 x 1-11/18" P dom*—Tram with Tegtder panel to drywall pertcretar(=RrESTA, tOQ82oSTp: 2'StistghtTran Iwn 120 x2 x1-1/2" AXtii2tX1R -:.:_.:: .:'. i.2"Cu►varD Trarrsti0n 120 z 2 x 1-1 " Attifl4STR. .::::: 4"SSrelghtTtan 120 x 4x 1-1/2" AXUW IJR. 4"Cuived TrattsitWn 120 x 4 x 1-1/2" AXTi36STR:: .. B".StraightTransBion 120x6x1-1/2" AXTRBGttR 6"Curoad Ttatlfp@on 120 x 6 x 1-1/2" 1A(tii8STR. . .::. 8"StraightTmnssbae 120 x 8 x 1-1/2" AX4SP1M EB Splice Plate — • T-Sar&electoralp — ^' Loolikftitisvl AXBTSTft. Drywall Bottom Trim 120 x 1-1/8 x 27/32" 6 For more information,call 1 877 276 7876 AXIOM® TRIM AXIOM®ONE-PIECE DRYWALL TRIM • Malang Contmercial-tpargy,hetdipped galvanized steel Length!Item ham Plantar Description AX1PC2STR 25"One-fie Straight Drywall Trim HANGER WIRE DGS AXnBC AX1PC2lJR 2.5'One-Piece Curved DrywaNTrim ✓ +-_r�;� 2-8118' a�p p p p e o � � One-Piece Drywr r< '�`',s-•:m l;t S-<�scj ail Trim 5/8'Drywall AX1PC4SIR 4'One-Piece Straight Drywall Trim HANGER WIRE DOS AXTBO • 4. 11111111111M11. AX1 PC4CUR 4"One-Piece towed Drywall Trim {-r.�7�1 Drywall Trim �eao=e°a_ �.r 5/8°Drywall AX1 PCSSTA 8"One-Piece Straight Oryvrall Trim HANGER WIRE OGS AXTBC One-Piece AX1PC6OU B"One-Piece Curved Drywall Trim Drywall Trim 1e o0 oa 5/8'Drywall :Formore,informatiion;call 1 8772767876 7 ACCESSORIES DRYWALL GRID ACCES50RiES. A variety of drywall grid accessories are available to provide problem-solving solutions that save time,labor,and money. For a complete list of accessories,request submittal BPCS-3082: Item Number Qusnttt7r Description Perspective Application DWACS • :160 Dayw21 Attachment Clip facalitefes transition farm drywall to awl ceiling;locks under bulb of grid section to prevent \ • - ramard Ii We and inside SerXtae attachment surface on one e of exposed grid Dy+I3DC _ . . :: 250 3a,45-,60-and DO-degree Drarraall Angie i ps are used OW=. 250 to create positive mid secure angles for drywaa9 and ceilrg • DW&OC 250..- installations on either main beams or mass tees. \/ DY+t90C : 250: C� • 1110 • 30 Partition Tap%a is used to finish the top of a drywall • — partition fora continuous drywall/acoustical ceiling interface. • DW581.t 125" :: QB5 LT-Try Clip for 5/Ir gall with Leg Tabs; facilitates transition train drywall to ace steal ceiling;one-sided hold-down clip;eliminates need far drywall bead.Locking tabs e �y provide secure location for CGS lees. DW50LT . 125 D1 LT-Tranziion Cp for 9d1°Drywall with Locking Tabs fad transition from drywall to acoustical calhrg;one-sided bald down clip;eliminates the need fora kit drywall bead.Locking tabs provide secure location for DGS tees. MBAC 70 Philo Bean Adapter Brim altars to web of grid section; provides larger surface for screw attachment used es a told- dosvm clip for thin material(metal or ply lay-in pals); 0 a fastens drywall track to underside of exposed grid with lay-by ® . panels,leaving grid face free of screw holes. BiBSC2 200 MaIO Bean Spaces C p(2'in length)is used to space two parallel main beams 2'0.C.far air supply or return, r r GSC9 100 Add Geld Spacer Clip is used to space two parallel 6S612 100 maim beams for light fixtures,air diffusers,etc.;allows for 1/4" GSC16 100 adpshnents with three diffwtnt clips. 8 For more information,call 1 877 276 7876 ACCESSORIES DRYWALL GRID ACCESSORIES(_,_NTIND__ Item Number Quantity Description Perspecthre Apt on • XL4C 100 Crew Toe Adapter trip—isusedtoattarfieldnitcrosstees to main beams • a, Q a O 0 0 DDC 250 Double Drywall Clip In hang suspension system below eidstmg (I 14/2'grid face,transferring weight directly to hangerwhe; may be used to mesons the fire rating of an existing r -hng ,' `` and to support heart�allows far double layer of Ara ` '> 5/8"gypsum beard. `�� :4%.1. DLCC 250 Direct Lid Ceiling Cato hang suspension system below existing 15f16'grid face,transferrhng weight directly to hanger wire;may be used to prr+re thefua rating of an existing ' N ceiling and to support heavy aocessules. I ' DYtC 250 thyme C!p alovesfrnr a'second'tang to be installed below a drywall Ong attach through installed drywall to supporting shuCbaa. 1:‘ Q° U. ° For more:Information,call 1,:87-7 276-7876 9 CURVED MAIN BEAMS CREATING CURVES = . Creating curved framing for drywall is easy•: g g �and offers unlimited possibilities. • Custom radii to suit any design installation • You control the curve:. '... • Not limited to a pre-selected orr pm-determined curved radius. • Full range of clips and accessories make installation easier than bending stud and track. ®® ®® ®() 10® Radius and drywall thickness will determine on-enter Install RC2 clip using four screws spacing of cuts.Refer to"Establishing An Arc"on page 9 per clips. for creating a curved template. RC2 Clip is used to secure the main beam at the desired angle in curved ceiling with rout for installing cross tees.Refer to"Making a Template" --r=-r-:r•. - --r--o-=s-• --- on page 9. RC2 Clip must be installed at all knockout locations when used to frame a flat or curved ceiling. RC2 Clip Cross Tee RC2 Clip Cross Tee `.`IV ._a e Q CI n a - �, Cross Tee O o � ♦ \\\\�0 0 oDo o 0 0 0 �,��```� When Installing a vault,cross tees should be placed between RC2 clips. • � o O •� When installing a valley,cross tees should be placed at the RC2 clips. ‘30 0 o D • \\� o 7DO ,......,A101 o � 0o i `,`,,�♦, 10 For more information,call 1 877 276 7876 • MAKING A TEMPLATE ESTABLISHING AN ARC ANEIM How to draw a radius on a template(plywood,gypsum board,etc.) 1 Establish a center fine. 3 At 2'marks,identify points of arc below perpendicular 2 Mark 2'Increments on line perpendicular to center line. line(maintain consistent spacing of point).See radius charts on page 20. 4 Connect points to forma smooth arc. Example:43'arc using chart on page 16. 2 0" 20' 2I 1 LL.5L. 1 1 1 1I 5I T T 9'1'2-1/8' I Location of Fist I Row at Center Line ` COMPLETING THE TEMPLATE—OPTION 1 1 Cut along the arc and remove section of template 3 Screw RC2 clips to faceted main beam at all knockout 2 Cut main beam as required and position along the cut locations.* radius on the template(use the chart on page 20). 4 On the template,mark a rout location reference point to maintain consistent rout location. .41,..._ .. ..-. .-7,-, .: Main Beam RC2 Clip placement Vaults—Cross tee placement in routs between cuts. Template under valleys—Crass tee lock into rout on RC2 clip(tight radius Eislailations may Main Beam require bending up of the flange et ends of cross tees). ® . opt,15' H118906F08 ®, Other 15' HB89Q6F16 to FitTe e iG ."'.4.. ...,. yr �t Radius of Vault Pius Thickness of Gypsum Cut Board(Can Be Partial:Radius.of Large Spans) Cut I. Span of Vault For more information,call 1 877 276 7876 11 • MAKING A TEMPLATE 1-1.11 COMPLETING THE TEMPLATE—OPTION 2 1-1/2°x 3 Plywood or Blocks 12' Clamp main beam to flex track Main Beam RC2 Clip Ø11h1 3/111//174 11 21 or 3-5/8to p 'Screw flex track flex track .1% Wo,k 4.414 Platform 4'x 12' Gypsum Wall Board or Plywood 1 Draw radius on board. 12' PAsin Beam 2 Screw flex track to board along radius line. 4' 3 Gut main beams as required and position along The flex track on the template. Flarack 8245U5 /for span. Screw Flex Tmck to Plywood 4 Sciew RC2 clips faceted main beam at all \ es A / knockout locations. 5 On the template,mark a rout location reference point to maintain consistent rout location. • Contractors'efficiency and understanding of the suspended grid system constniction provides performance benefits and cost savings. • An unlimited range of vaults and valleys can be constructed using faceted main beams made on the job to meet design needs. • Single and multiple curved ceilings can be framed quickly and easily. 12 For more information,call 1 877 276 7876 • VAULTS WORKING WITH VAULTS 1 Hanger wires must be minimum 12 gauge and spaced along the main beams not more than 4'on-center for gypsum board construction and not more than 3'on-center for plaster work(spaced as required to support load). 2 Add vertical braces as required to stabilize the frame. 3 Thickness of the sheeting material is determines by its plasticity.Refer to table titled"Drywall Bending Radius"on page 19. 4 For vaults,space the main beams 4'on-center for gypsum board construction and 3'on center for plaster.Angle or channel molding is used to frame the ends of the structure. 4111111111111.1 :,. 1 \ , 444400p. 1 � ,• 1 \ �A it \ ``�'� • • • For more:information;•call`:1'877 276 7876 13 ARCHES:;AND .. : BARREL.:.VAULTS.: . :. • . 11-1111 BARREL VAULT _ _- • Hanger. • Vertical Brace • I, Main Beam r'.. `I %'. ,•''s 0 Crass Tee , jl,�i �. '... .. l'' ' ..• __•... • '.. -'----.---- A'- :11: ,..,r,-I•ei.i i/, 7 q�/:'iv VAULT WITH PERIMETER LIGHT COVE FLOATING VAULT u 1 o Hanger Wire 1 Track r# Channel MOB /IJ� • iG� G C--1‘11100-1204\ /--, r000sio, /see/ cti RC2 DWBOC Main Beam Ai/ ,e 1 14 For more information,call 1 877 276 7876 BARREL VAULTS AND CLOUDS DOUBLE BARREL VAULT MaIn Beam Angle Clip Available in 30°,45°,60°,90° Concave Angle Clip Available In Hole for 30°,45°,60°,90° Hanger Wire Convex Matti Beam CEILING CLOUD Al= Angle Brace Vertical Brace to Stabilize Hanger Wire— 1 Vertical Btace r, iz-a• Cross Tee __47 4 45;,, Main Ar Beam Hanger Win3 Nkr rarri %11,11141160, Track or channel molding Gypsurn Board Upside Down Main Beam (for End Panel) RC2 Clip) Track or channel molding Wall Board For more Information,call 1 877 276 7876 15 • DOMES :' : WORKING WITH'DOINES Dames,like arches;have many variable characteristics that make each design unique:_Witt a suspended drywall grid system,you can easily create the desired look of dames ranging from simple to complex . Hanger Wires Spaced Vertical Brace as Required '/' : : , Sheet Metal • fi�t 44 Main Beam ..• 1. Cut&Screw g,' Cross Tee A� ;.. Cross Tees if, ft > I Main Beam I :Detemiine the starting point attire top and bottom of the dome. 2'.Prepare a sheet Metal disk or donut for the top of the dome.The disk should be one to two feet In diameter and should be fabricated from steel with a thickness of at least 25-gauge thickness.Note that the center of the dome may need to be open to receive an electrical box, pole,or some other architectural detail.Refer to"Options for Top of Dome"on page 17. 3 Prepare airing for the base of the dome from rolled angle or charm!. 4:Attach curved main beams to the disk at the top of the dome and to the ring at the bottom with sharp point pan or wafer head screw(by others). 5 Mains should be spaced no greater than 4'on-center(measured at the bottom ring).Install main beams 2'on-center for a radius of 15'or less.(Refer to Radius Chart on page 22.) 6 Use crass tees cut to the appropriate length and screwed to the flange of the main beams to complete the dome frame structure. 7 Cross tees are not required near the top of the dome when The space between mains becomes less than 16". • 8 The sheathing must be cut Into pie shaped sections and screw attached to the framework. 16 For more information,call 1 877 276 7876 DOMES OPTIONS FOR TOP OF DOME AMIE Vertical Brace Folded Plate Dome Sheet Metal disk Positive Attachment Top(by ) Or "kW* itinlitliNt** yAimitanie Light Fixture Cone • Threaded Rods - , > (by others) OIL lAtritisrljtzwallimi t 1�arli �WaF ,/ o'lSheet Metal disk (by others) 41111114 W:i\ 11111. • \\*, . . . •: _.• •. . • . For more,information,call=l:877 276..7876 17 DRYWALL GRID SYSTEMS IrmlElk COMPONENTS Electrical Chain: ..`. . : Self Supporting Tee Top Sheet Metal ' Disk wi h Hole. Pan Head Screw r%anvp�;cr>+ % Sl. „oft..., 0 14,,,kit.-741...”!:_4041,„reik* / IL Allik18\1 `1 Ta Electrical Box )r�/ Pan Head �� metal, sheet with ;f Screw In if E , _. e. „`Ai��i%t:+ • 18 For more information,call 1 877 276 7876 DOMES . . . .. DOMES Dome with Skylight 1 r ••„ . • 1 ,�o is 1/:::\T'— ---- -z''---.' . . �/! 0—'------ T—=T1-H" ,...... ____. IltiNt\ Typical Details Radius GYPsum Ranger Wire 4' _�,`, Wall Board I ��O.C.arises >.% .•,. r`l�� .".... .A. . j iii. ,,. /I i NAO/ 'B0„. / �y y , - ,4.‘ �����` RadiusB�m \\ ��` .0 4.�i .4—,-: i/ RC2 Radius Cll A. ®`-:• I Main Beam �t► J Main Beam Main Beam ` / ,` Curved Angle Molding of des ----\ Gypsum Wail Bid l `` See page 15 for Bending Radius of gypsum board. For more information,call 1 877 276 7876 19 DOMES OTHER DOMES Multi-Level.Dome Egg or Elliptical Dome Saucer Dome Up:.. Pole Dome Saucer Dome Down Saucer Dome Step Up Dome Checker Board Dome Offset 2 way Radius Dome (step down) Column Ring Made from a Metal Angle 0 0 ° 'c4 am o-- 044,(41 0 o. 20 For more Information,call 1 877 276 7876 • FINISHING AND EXTERIOR APPLICATION DRYWALL BENDING RADIUS AIM Drywall Bending Radii Minimum Maximum Cross Tee Minimum Maximum Cross Tee Water Required Material Radius(dry) Spacing(dry) Radius(wet) Spacing(wog Per Panel(cm) 1/4"ffl-flax Gypsum 32" 9° 20"concave 8°concave 14"coax 6"convex 1/4"Gypsum 5' 8" 2' 6" 30 ounces 3/8°Gypsum 7-1/2" 3' 8" 35 ounces 1/2"Gypsum 20' 16" 4' 12° 45 ounces 5/8"Gypsum 28' 24" NOTE:Referto gypsum wallboard manufaching fur additional Information. if required,apply water to the side of the panel that will be in compression.Apply the water uniformly over the surface of the boards. Stack moistened boards on a fiat surface and cover with plastic sheeting.Allow water to soak Into the panels far at least 1 hour before application to the frame.Allow Installed panels to dry for 24 fours before finishing. AIIIIIII CONTROL JOINTS Please refer to ASTM C840 Section 20.3.3-20.4 for control Ceiling expansion Joints are installed to separate the metal requirements. suspension system when expansion joints occur in buildings, when span is over 100'or when metal changes direction. Expansion joints are required to separate a system in T-,H-, L-and U-or Circle-shaped buildings to eliminate cracking from expansion.Expansion and control joints look similar but perform different functions. Non-Module Cut and Screw Application,Metal-to-Metal NOTE Refer to the Transition Moldings Data Page(BPCS-4307)and Axioms—Transitions Data Page(BPCS•3530)to view full details. For-more information,call 1°877 276 7876 21 • • RADIUS IN FEET • RADIUS DIMENSIONS { Radius Dimension •11'0° " 12'.0'. ° .13'0° 14'0"- 15 0° 16'0° 17'0" 18'0° :19'0" 20..01 - 21'0° 22'0" '23'.0" 24'0": m . .2' 2° 2-1/4" • 2" 1-7/8° 1-3/4" 1-5/8" 1-1/2° 1-12" 1-3/8° 1-1/4" 1-1/4" 1-1/8° 1-1/8" 1-1/8" 1" f i 4' 10" .9-1/8° 8-1/4" • 7-5/8" •7" .••• 6-12° 6-1/8° 5-3/4" 5-3/8" 5-1/8" 4-7/8" 4-5/8" 4-3/8° 4-1/4° 4" • c j 6' 2'0" 1'9-3/8" 1'7-3/8 1'5-5/8" 1'4-1/4° 1'3" 1'2" 1'1-1/8" 1'0-3/8" 11-3/4" 11-1/8° 10-1/2" 10° 9-5/8" 9-1/8" •• V! •8' 4'0" 3'5-5/8 3'0.3/4° ,2`9-1/8" •2'6-1/8°. 2'3-3/4" 2'1-3/4" 2'0° 1'10-12° 1'9-1/4° 1'8-1/8" 17° 1'6-118" 1'5-1/4" 1'4-12° • ��7 i . 25'0" •26'0° 27'0 28'0° . 29'0 30'0° 31'0",. •32'0" 33'.0 •34'0" 35'0° ; 36'0" 37!0" 38'0° 39'0"• ! `� ; . 2' ' •1" . 1° . • 7/8". 7/8 . 7/8" 7/8° 314" 3/4° 3/4" 3/4" 3/4" 3/4° 518" 5/8° 5/8" c • 4'. •. 3-7/8" . 3-3/4" 35/8 3-12° 3-3/8" 3-1/4" 3-1/8" 3" 3" 2 7/8" 2-3/4° 2-3/4° 2-518° 2-5/8° 2-1/2' • E j .6' • 8-3/4" " 8-1/2" 81/2". • 7-7/8° 7-1/2" 7-1/4" 7-1/8" 6-7/8° 6-5/8" 6-3/8° 6-1/4" 6-1/8" 5-7/8" 5-3/4" 5-5/8° v j 8' 1'3-3/4" 1'3-1/8" .1'25/8" . 1'2° 1'2-12" 1'1-1/8" 1'0-5/8" 1'0-1/4" 11-12" 11-12° 11-1/8" 10-7/8" 10-12° 10-1/4° 10" 40'0. 41'0". 42'0" 43'0° . 44'0", .•45'0" 46'0" -47'0" . 48'0"' 49'0" 50'0"_ 51'0" 52'0° 53'0°' 54'0" • i j :2' • 5/8 5/8" . .5/8" . 5/8" 5/8" 5/8° 1/2° 12" 1/2" 12" 12° 12" 12° 12° 1/2° . { 4'. - .2-3/8" 2-3/8° 2-3/8". •2=1/4° 2-1/8" 2-1/8° 2-1/8° 2-1/8° 2" 2" 2" 1-7/8" 1-7/8" 1-3/4° 1-3/4" • ' j 6' .5L12" •,5-318 5-1/4°. 5-1/8° 5" 4-7/8" 4-314" 4-5/8" 4-12° 4-1/2" 4-3/8" 4-1/4" 4-1/4" 4-1/4" 4" , • 8' 9-3/4".• 9-12" 9-1/4" 9" 8-7/8" 8-5/8" 8-12" 8-1/4" 8-1/8" 7-7/8° 7-3/4" 7-5/8° 7-12° 7-3/8" 7-1/8" 55'.0" . '56'0" 57`0 58'0° ' 59'0"r 60'0° 61'0"- 62'0". .63'0" ..64'0", 65'0": 66'0" .67"07. 68'0" 69'0" .2' 12" 12" 12" 1/2° 12" 3/8" 3/8" 3/8" 3/8° 3/8" 3/8" 3/8° 3/8" 3/8° 3/8" • :# ---! 4' .•1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-5/8" 13/8" 1-518° 1-5/8" 1-12" 1-1/2° 1-12" 1-12" 1-12" 1-12" 1-3/8° • , , .) .6' 4" 3-7/8" 3-7/8" 3-3/4° 3-3/4° 3-5/8" 3-5/8" 3-12" 3-12" 3-3/8" 3-3/8" 3-1/4° 3-1/4" 3-1/4" 3-1/8" I 8' 7 677/8"• 6.3/4" 6 /8" 6-5/8° 6-12" 6-3/8" 6-1/4° 6-1/8" 6" 6" 5-7/8" 5-3/4" 5-3/4" 5-5/8° •{ 70'0" _71'0" . 72'0' 73'.0" 74'0" ' 75'0°. 76'0" 77'0 78'0°. 79'0" 80'0" 81'0° . ..82'0" 83'0" ,84'0" 2' 3/8" 3/8° 3/8" 3/8" 318" 3/8° 3/8" 3/8" 3/8" 3/8" 3/8° 3/8" 3/8° 3/8° 3/8° 1 3/8°_ •1-3/8" 1-3/8" 1-3/8° 1-3/8" 1-1/4" 1-1/4° 1-1/4" 1-1/4° 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/8° i s 6' 3-1/8°. 3-1/8" 3" 3° 3" 2-7/8" 2-7/8" 2-7/8" 2-3/4" 2-3/4" 2-3/4" 2-3/4" 2-5/8° 2-5/8" 2-5/8" ' 8' 5-12"_ 5-12" 5-3/8° 5-1/4" 5-1/4° 5-1/8° 5-1/8" 5" 5" 4-7/8" 4-7/8" 4-3/4" 4-3/4" 4-5/8° 4-5/8° • 65'0" " 86'0" 87'0 88'0' 89'0°- 90'0° 91'0 92'0" 93'0° 94'0" .95'0"- : 96'0° 97'0" ` 98'0" 99'0": 2' 3/8" 1/4° 1/4° 1/4" 1/4° 1/4° 1/4" 1/4° 1/4" 1/4" 1/4" 1/4° 1/4" 1/4" 1/4" , - " 4' • 14/8" 1-1/8° 1-1/8" 1-1/8" 1-1/8" 1-1/8" 1-1/8" 1-1/8" 1-1/8° 1° 1" 1° 1" 1° 1" ,C " 1 6' 2-5/8" 2-1/2° 2-12° 2-12° 2-1/2" 2-3/8° 2-3/8" 2-3/8" 2-3/8° 2-3/8" 2-1/4" 2-1/4" 2-1/4" 2-1/4" 2-1/4° •1. i 8' 4-12" 4-12° 4-12" 4-3/8" 4-3/8" 4-1/4" 4-1/4" 4-1/4" 4-1/8" 4-1/8° 4-1/8° 4" 4" 4" 3-7/8" • .100'0"..'105'0° 110'0". 115'0" 120'0'_ 125'0° 130:0° 135'0" 140'0 145'0" 150'.0" 155'0" 160..0'. 165'0° 170'0". 2' 1/4" 1/4" 1/4° 1/4° 1/4" 1/4" 1/4" 1/4" 1/4" 1/4° 1/4" 1/4° 1/8° 1/8° 1/8° - ; 4' 1" 1° 7/8" 7/8" 7/8° 3/4" 3/4" 3/4" 3/4" 3/4" 5/8" 5/8" 5/8" 5/8" 5/8" 6' 2-1/4" 2-1/8" 2" 1-7/8" 1-7/8" 1-3/4° 1-3/4" 1-5/8" 1-5/8" 1-12" 1-1/2" 1-318° 1-3/8° 1-3/8° 1-1/4° f j 8' 3-7/8° 3-3/4° 3-12" 3-3/8" 3-1/4" 3-1/8" 3" 2-7/8" 2-3/4° 2-3/4° 2-5/8" 2-1/2° 2-3/8° 2-3/8" 2-1/4" • 175'0"- 180'0° .185'0" 190'0" 195'•0 200'0"- 240" 220'0° , 230'0" 240'0" 250'0°'. - . 2' 1/8" 1/8" 1/8" 1/8° 1/8° 1/8" 1/8" 1/8" 1/8" 1/8" 1/8" • j ". j 4' 5/8" 5/8° 12" 12" 1/2° 1/2" 1/2" 1/2° 3/8° 3/8" 3/8" 6' 1-1/4" 1-1/4" 1-1/4" 1-1/8" 1-1/8" 1-1/8° 1" 1" i" 7/8° 7/8° 8' 2-1/4" 2-1/8" 2-1/8" 2" 2" 2° 1-7/8° 1-3/4° 1-5/8" 1-5/8° 1-12" 22 For more information,call 1 877 276 7876 ESTIMATING ESTIMATING MATERIAL Area of ceiling completed by one carton Item Number I Length I Pcs/Ctn. I LF/Cbn. I LbsiChi. O.C. O.C. O.C. O.C. O.C. O.C. DRYWALJJSTUCCO GRID MAIN BEAM H08901 144" 20 240 71 480 720 960 1000 sq.ft 1038906/08906090 144" 12 144 53 288 432 576 600 sq.ft H08906F08,1 D8906F18 144" 12 144 53 sq.ft. DRYWALL/STUCCO GRID 1-1/2°FACE CROSS TEES XL8985 72" 36 218 78 144 288 432 sgft X18947P018947F090" 50' 36 150 56 100 200 300 sq.ft, Y19945P1)118945P590 48" 36 144 52 96 192 288 sq.ft. XL7936690 38° 36 108 39 144 216 sq.lt. XL89261XL89261180 24" 36 72 26 48 sq.ft. **Dimensions are nominal. Item number I Length I PcslCtn. I LF/Ctn. I LbsJCht REVERSE MOLDINGS 7857 120" 30 360 51 7858 120° 20 240 67 DRYWALL IRRIEMME0 COMM MOLDING 7838 120" 20 200 36 DRYWALLANGLE MOLDING H97801890 120" 30 300 38 KAM-12 144" 30 360 31 KAM-10 120" 30 300 49 LAM-12 144" 30 360 31 Estimating Leal Feet of Grid Example calculation based on 5,100 SF ceiling: Based on Square Footage of Ceiling Main beam at 48"O.C. Spacing Percent of 5,100 SF x.25=1,275 LF of COlifµaraid Squar0 Footage 1,275 LF -144 LF/Ctn=9 cartons needed 8° 108% Cross tee at 16"0.C. 12' 100% 5,100SFx.76=3,8761F 16° 76% 3,876 LF=144 LF/Ctn=27 cartons needed 20" 60% 24" 50% 30" 40% 38" 33% 48" 25% B0" 20% For more Information,call 1 877 276 7876 23 1 + ilCOMcheck Software Version 4.1.5.0 l IPAEnvelope Compliance Certificate rH c) w Project Informatioyullji);Liti(lij ' , �; ,�_ < F,,Energy Code: 2018 IECC " ' ---- �� nX D FiProject Title: Garve H undai Addition / I _ <Location: Glens Falls, New Yor f �` �"� W Climate Zone: 6a _ I tom' i. - Project Type: 1 TO`P�'>y' (]-.- t--;`a" -- 0.. R1 j yP Addition a t;Li�,�„ ,,�c, Vertical Glazing/Wall Area: 4% ''T�- -"i �'>-- .. •-i;_l� "� p -�____-_y' y) = 44 r. n Construction Site: Owner/Agent: Designer/Contractor: I- n � 257 Dix Ave Marc Garvey Ethan P. Hall 0 Queensbury, NY 12804 Garvey Hyundai Rucinski Hall Architecture ,A REVIEWED 257 Dix Ave Dix Ave 0 FOR Glens Queensbury, NY 12804 Glens Falls, NY 12801 1.,..) N ENERGY CODE COMPLlq('xs) 2-9003 518-741-0274 ; v o eigl@gmail.com ephall@nycap.rr.com 0 N Building Area Floor Area N 1-Automotive Facility: Nonresidential 6707 ---- Envelope Assemblies — Assem IF rw-Tc:11 Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor,e> Perimeter Roof 1:Metal Building,Standing Seam,Filled Cavity with Thermal 6707 38.0 0.0 0.037 0.031 Blocks(d),[Bldg.Use 1 -Automotive Facility] Floor 1:Slab-On-Grade:Unheated,Vertical 4 ft.,[Bldg.Use 1 - 334 — 10.0 0.480 0.540 Automotive Facility](c) NORTH Exterior Wall 2:Metal Building Wall,Single Layer Mineral Fiber(in 1994 25.0 0.0 0.059 0.052 cavity,thermal block at girt),[Bldg.Use 1 -Automotive Facility] Door 4:Insulated Metal,Non-Swinging,[Bldg.Use 1 -Automotive 120 -- -- 0.070 0.179 Facility] Door 5:Insulated Metal,Non-Swinging,[Bldg.Use 1 -Automotive 100 -- -- 0.070 0.179 Facility] Door 6:Insulated Metal,Non-Swinging,[Bldg.Use 1 -Automotive 100 -- -- 0.070 0.179 Facility] Door 7:Insulated Metal,Non-Swinging,[Bldg.Use 1 -Automotive 100 -- -- 0.070 0.179 Facility] Door 8:Insulated Metal,Non-Swinging,[Bldg.Use 1-Automotive 100 -- -- 0.070 0.179 Facility] Door 9:Insulated Metal,Non-Swinging,[Bldg.Use 1 -Automotive 224 — -- 0.070 0.179 Facility] EAST Exterior Wall 1:Metal Building Wall,Single Layer Mineral Fiber(in 3014 25.0 0.0 0.059 0.052 cavity,thermal block at girt),[Bldg.Use 1 -Automotive Facility] Window 1:Metal Frame with Thermal Break:Fixed,Pert.Specs.: 96 -- -- 0.290 0.360 Product ID Product label,SHGC 0.33,[Bldg.Use 1 -Automotive Facility](b) Door 1:Glass(>50%glazing):Metal Frame,Non-Entrance Door,Perf. 140 -- -- 0.290 0.430 Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 1 of 20 , Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor1e1 Perimeter Specs.:Product ID product label,SHGC 0.33,[Bldg.Use 1 - Automotive Facility](b) Door 2:Insulated Metal,Swinging,[Bldg.Use 1-Automotive Facility] 21 -- -- 0.300 0.370 Door 3:Insulated Metal,Swinging,[Bldg.Use 1 -Automotive Facility] 21 -- -- 0.300 0.370 WEST Exterior Wall 3:Metal Building Wall,Single Layer Mineral Fiber(in 500 25.0 0.0 0.059 0.052 cavity,thermal block at girt),[Bldg.Use 1 -Automotive Facility] Door 10:Insulated Metal,Swinging,[Bldg.Use 1-Automotive Facility] 21 -- -- 0.300 0.370 (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. (d)Thermal spacer block with minimum R-3.5 must be installed above the purlin/batt,and the roof deck secured to the purlins. Envelope PASSES: Design 7% better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2018 IECC requirements in COMchecl ers'•n,4.1.5.0 and to comply..with any applicable mandatory requirements listed in the Inspection Checklist. ,i ` -j` 1t'' Ethan P.Hall-Architect f'' Gl J{/L�/LUGG Name-Title Signa '' �yr , ' , C. Date as ti +* � Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 2 of 20 r y 111111 COMcheck Software Version 4.1.5.0 ‘fii Interior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Garvey Hyundai Addition Project Type: Addition Construction Site: Owner/Agent: Designer/Contractor: 257 Dix Ave Marc Garvey Ethan P. Hall Queensbury, NY 12804 Garvey Hyundai Rucinski Hall Architecture 257 Dix Ave 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 (518)792-9003 518-741-0274 mdgmdgl@gmail.com ephall@nycap.rr.com Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Automotive Facility 6707 0.71 4762 Total Allowed Watts= 4762 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Automotive Facility LED 1:LED Linear 15W: 4 7 32 224 LED 2:LED Linear 11W: 2 6 24 144 LED 3:LED Linear 15W: 2 22 32 704 LED 4:LED Linear 11W: 3 6 32 192 LED 5:LED PAR 13W: 1 61 28 1708 Total Proposed Watts= 2972 Interior Lighting PASSES: Design 38% better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck V:- ',.n 4.1. and o comply with any applicable mandatory requirements listed in the Inspection Checklist. r / Ethan P.Hall-Architect ' Juty 0072 Name-Title Sig - ure Date Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 3 of 20 COMcheck Software Version 4.1.5.0 ril Exterior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Garvey Hyundai Addition Project Type: Addition Exterior Lighting Zone 4(High activity metropolitan commercial district) Construction Site: Owner/Agent: Designer/Contractor: 257 Dix Ave Marc Garvey Ethan P. Hall Queensbury, NY 12804 Garvey Hyundai Rucinski Hall Architecture 257 Dix Ave 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 (518)792-9003 518-741-0274 mdgmdgl@gmail.com ephall@nycap.rr.com Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage (B X C) Drive-up windows/doors 6 windows 200 No 1200 Entry canopy 3 ft2 0.4 Yes 1 Free standing/attached sales canopy 1 ft2 0.7 Yes 1 Total Tradable Watts(a)= 2 Total Allowed Watts= 1202 Total Allowed Supplemental Watts(b)= 900 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 900 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Drive-up windows/doors(6 windows or doors): Non-tradable Wattage LED 1:LED A Lamp 13W: 1 8 32 256 Entry canopy(3 ft2):Tradable Wattage LED 2:LED PAR 15W: 1 4 32 128 Free standing/attached sales canopy(1 ft2):Tradable Wattage LED 3:LED Roadway-Parking Unit 82W: 2 6 64 384 Total Tradable Proposed Watts= 512 Exterior Lighting PASSES: Design 43%better than code Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck ersion 4. .0 to comply with any applicable mandatory requirements listed in the Inspection Checklist. / Ethan P. Hall-Architect .. V JPV Name-Title Signature Date Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 4 of 20 , AfiCOMcheck Software Version 4.1.5.0 i Mechanical Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Garvey Hyundai Addition Location: Glens Falls, New York Climate Zone: 6a Project Type: Addition Construction Site: Owner/Agent: Designer/Contractor: 257 Dix Ave Marc Garvey Ethan P. Hall Queensbury, NY 12804 Garvey Hyundai Rucinski Hall Architecture 257 Dix Ave 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 (518) 792-9003 518-741-0274 mdgmdgl@gmail.com ephall@nycap.rr.com Mechanical Systems List Quantity System Type&Description 1 HVAC System 1 (Single Zone): Heating:5 each-Unit Heater,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Ec,Required Efficiency: 80.00%Ec Fan System: FAN SYSTEM 1 —Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Constant Volume, 1000 CFM,0.5 motor nameplate hp,0.0 fan efficiency grade Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The •roposed mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck V ion 4.1.ipI a • comply with any applicable mandatory requirements listed in the Inspection Checklist. Ethan P. Hall-Architect 0/JULY2022/ Name-Title Sig re Date Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 5 of 20 , COMcheck Software Version 4.1.5.0 14 Inspection Checklist Energy Code: 2018 IECC irP.' Requirements: 88.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans and/or specifications provide all ❑Complies Requirement will be met. [PR1]1 information with which compliance ODoes Not can be determined for the building ❑Not Observable Location on plans/spec:A-1 envelope and document where ❑Not Applicable exceptions to the standard are pP e claimed. C103.2 Plans,specifications, and/or OComplies Requirement will be met. [PR2)1 calculations provide all information ❑Does Not with which compliance can be ['Not Observable Location on plans/spec: M-1 determined for the mechanical systems and equipment and ONot Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 Plans,specifications, and/or ElComplies Requirement will be met. [PR4]1 calculations provide all information ❑Does Not with which compliance can be ['Not Observable Location on plans/spec: E-1 determined for the interior lighting and electrical systems and equipment ONot Applicable and document where exceptions to the standard are claimed.Information provided should include interior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. C103.2 Plans,specifications, and/or ❑Complies Requirement will be met. [PR8]1 calculations provide all information EDoes Not with which compliance can be ❑Not Observable Location on plans/spec: E-1 determined for the exterior lighting and electrical systems and equipment ONot Applicable and document where exceptions to the standard are claimed.Information provided should include exterior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. C402.4.1 The vertical fenestration area <=30 ElComplies Requirement will be met. [PR10]1 percent of the gross above-grade wall ❑Does Not area. Location on plans/spec:A-1 [Not Observable ONot Applicable C402.4.1 The skylight area <=3 percent of the ElComplies Requirement will be met. [PR11)1 gross roof area. ❑Does Not ❑Not Observable Location on plans/spec:A-1 ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 6 of 20 Section # Plan Review Complies? Comments/Assumptions & Req.ID C406 Plans,specifications,and/or OComplies Requirement will be met. [PR9]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable Location on plans/spec:A-1 determined for the additional energy efficiency package options. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 7 of 20 Section # Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID C303.2 Slab edge insulation installed per ❑Complies Requirement will be met. [FO4]2 manufacturer's instructions. ❑Does Not DNot Observable Location on plans/spec:A-1 ❑Not Applicable C303.2.1 Exterior insulation protected against ❑Complies Requirement will be met. [FO6]1 damage,sunlight, moisture,wind, ❑Does Not landscaping and equipment maintenance activities. Not Observable ❑Not Applicable C105 ;Installed slab-on-grade insulation type ❑Complies See the Envelope Assemblies table for values. [FO3]z ;and R-value consistent with insulation ODoes Not specifications reported in plans and COMcheck reports. ENot Observable ❑Not Applicable C402.2.4 Slab edge insulation depth/length. ❑Complies Requirement will be met. [FO7]2 !Slab insulation extending away from ❑Does Not building is covered by pavement or See the Envelope Assemblies table for values. >= 10 inches of soil. ❑Not Observable ❑Not Applicable C402.2.6 ;Radiant heating systems panels ❑Complies Exception: Requirement does not apply. [FO12]3 !insulated to>=R-3.5 on face opposite ❑Does Not space being heated. See the Envelope Assemblies table for values. ❑Not Observable ❑Not Applicable C403.12.2 Snow/ice melting system and freeze ❑Complies Requirement will be met. protection systems have sensors and ❑Does Not C403.12.3 controls configured to limit service for ❑Not Observable Location on plans/spec: M-1 [FO9]3pavement temperature and outdoor ENot Applicable temperature.future connection topP controls. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 8 of 20 Section Framing/Rough-In Inspection Complies? Comments/Assumptions & Req.ID C303.1.3 ;Fenestration products rated in ❑Complies Requirement will be met. [FR12]2 accordance with NFRC. ODoes Not { ['Not Observable Location on plans/spec:A-1 ONot Applicable C303.1.3 Fenestration products are certified as ❑Complies Requirement will be met. [FR13]1 to performance labels or certificates ❑Does Not provided. Location on plans/spec:A-1 ❑Not Observable ONot Applicable C402.4.3 Vertical fenestration SHGC value. ❑Complies See the Envelope Assemblies table for values. [FR10]1 ❑Does Not ONot Observable ONot Applicable C402.4.3, Vertical fenestration U-Factor. ❑Complies See the Envelope Assemblies table for values. C402.4.3. ODoes Not 4 1 ONot Observable [FR8] ❑Not Applicable C402.4.4 C U-factor of opaque doors associated ❑Complies See the Envelope Assemblies table for values. [FR14]2 I with the building thermal envelope ODoes Not ;meets requirements. ONot Observable ❑Not Applicable C402.5.1 The building envelope contains a ❑Complies Requirement will be met. [FR16]1 continuous air barrier that is sealed in ODoes Not an approved manner and either ONot Observable Location on plans/spec:A-1 constructed or tested in an approved manner.Air barrier penetrations are ONot Applicable sealed in an approved manner. C402.5.2, ;Factory-built fenestration and doors ❑Complies Requirement will be met. C402.5.4 are labeled as meeting air leakage ODoes Not [FR18]3 requirements. :Not Observable ONot Applicable C402.5.7 ;Vestibules are installed on all building ❑Complies Exception: Requirement does not apply. [FR17]3 ;entrances. Doors have self-closing ❑Does Not ;devices. ❑Not Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 9 of 20 Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.5, ;Heated water supply piping conforms ❑Complies C404.5.1, Ito pipe length and volume ❑Does Not C404.5.2 ;requirements.Refer to section details. ONot Observable [PL6]3 i ONot Applicable C404.6.3 Pumps that circulate water between a DComplies [PL7]3 ;heater and storage tank have controls ['Does Not that limit operation from startup to ONot Observable <=5 minutes after end of heating j cycle. DNot Applicable C404.7 1 Demand recirculation water systems DComplies [PL8]3 I have controls that start the pump ❑Does Not upon receiving a signal from the I action of a user of a fixture or ONot Observable appliance and limits the temperature ONot Applicable of the water entering the cold-water piping to 104°F. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 10 of 20 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C402.2.6 !Thermally ineffective panel surfaces of DComplies Exception: Requirement does not apply. [ME41]3 sensible heating panels have ❑Does Not insulation>= R-3.5. ONot Observable ONot Applicable C402.5.5, Stair and elevator shaft vents have OComplies Exception: Requirement does not apply. C403.2.4. motorized dampers that automatically ❑Does Not 3 !close.Refernece section C403.7.7 for [ME3]3 ;operational details. ['Not Observable ONot Applicable C403.11.3 HVAC piping insulation insulated in DComplies [ME61]2 accordance with Table C403.11.3. DDoes Not Insulation exposed to weather is protected from damage and is ['Not Observable provided with shielding from solar ONot Applicable radiation. C403.8.4 ;Motors for fans that are not less than DComplies [ME142]2 {1/12 hp and less than 1 hp are DDoes Not electronically commutated motors or have a minimum motor efficiency of ❑Not Observable 70 percent.These motors have the ONot Applicable means to adjust motor speed. C403.8.5 ;Each DX cooling system>65 kBtu DComplies [ME143]2 and chiller water/evaporative cooling DDoes Not ;system with fans> 1/4 hp are ONot Observable designed to vary the indoor fan airflow I as a function of load and comply with ONot Applicable ;detailed requirements of this section. C403.12.1 Systems that heat outside the building DComplies Exception: Requirement does not apply. [ME71]2 envelope are radiant heat systems DDoes Not controlled by an occupancy sensing device or timer switch. ❑Not Observable ❑Not Applicable C403.2.3 HVAC equipment efficiency verified. DComplies See the Mechanical Systems list for values. [ME55]2 DDoes Not ONot Observable { ONot Applicable C403.2.2 Natural or mechanical ventilation is DComplies Requirement will be met. [ME59]1 provided in accordance with DDoes Not International Mechanical Code ['Not Observable Location on plans/spec: M-1 Chapter 4. Mechanical ventilation has 1 capability to reduce outdoor air supply ❑Not Applicable to minimum per IMC Chapter 4. C403.7.1 Demand control ventilation provided DComplies Requirement will be met. [ME59]1 for spaces>500 ft2 and>25 DDoes Not people/1000 ft2 occupant density and [Not Observable Location on plans/spec: M-1 served by systems with air side economizer,auto modulating outside DNot Applicable air damper control,or design airflow >3,000 cfm. C403.7.2 Enclosed parking garage ventilation ❑Complies Exception: Requirement does not apply. [ME115]3 has automatic contaminant detection DDoes Not and capacity to stage or modulate !fans to 50%or less of design capacity. ONot Observable ❑Not Applicable C403.7.6 ;HVAC systems serving guestrooms in DComplies Exception: Requirement does not apply. [ME141]3 IGroup R-1 buildings with >50 ❑Does Not guestrooms: Each guestroom is provided with controls that ['Not Observable automatically manage temperature ONot Applicable Isetpoint and ventilation (see sections C403.7.6.1 and C403.7.6.2). 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 11 of 20 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.7.4 ;Exhaust air energy recovery on DComplies Requirement will be met. [ME57]1 systems meeting Table C403.7.4(1) ❑Does Not ;and C403.7.4(2). ONot Observable ONot Applicable • C403.7.5 Kitchen exhaust systems comply with DComplies Exception: Requirement does not apply. [ME116]3 replacement air and conditioned ❑Does Not supply air limitations,and satisfy hood rating requirements and maximum ONot Observable l exhaust rate criteria. ONot Applicable C403.11.1(HVAC ducts and plenums insulated in DComplies Exception: Requirement does not apply. accordance with C403.11.1 and ❑Does Not C403.11.2 j constructed in accordance with [ME60]2 i C403.11.2,verification may need to ONot Observable ;occur during Foundation Inspection. ONot Applicable C403.4.1. ;Heating for vestibules and air curtains DComplies Exception: Requirement does not apply. 4 ;with integral heating include ❑Does Not [ME63]2 I automatic controls that shut off the ONot Observable heating system when outdoor air ;temperatures>45F.Vestibule ONot Applicable j heating and cooling systems }controlled by a thermostat in the ;vestibule with heating setpoint<= 160F and cooling setpoint>=80F. C408.2.2. ;Air outlets and zone terminal devices ❑Complies Exception: Requirement does not apply. 1 i have means for air balancing. ❑Does Not [ME53]3 ONot Observable ONot Applicable C403.5, ;Refrigerated display cases,walk-in ❑Complies Exception: Requirement does not apply. C403.5.1, ;coolers or walk-in freezers served by ❑Does Not C403.5.2 !remote compressors and remote [ME123]3 ;condensers not located in a [Not Observable condensing unit,have fan-powered ONot Applicable condensers that comply with Sections 1 C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 12 of 20 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.2. ;Spaces required to have light- ❑Complies Requirement will be met. 2 I reduction controls have a manual ODoes Not [EL22]' control that allows the occupant to ❑Not Observable Location on plans/spec: E-1 reduce the connected lighting load in a reasonably uniform illumination ❑Not Applicable pattern >=50 percent. C405.2.1, Occupancy sensors installed in ❑Complies Requirement will be met. C405.2.1. classrooms/lecture/training rooms, ❑Does Not 1 1 conference/meeting/multipurpose Location on plans/spec: E-1 [EL18] rooms,copy/print rooms, lounges/breakrooms,enclosed offices, ❑Not Applicable open plan office areas, restrooms, storage rooms, locker rooms, warehouse storage areas,and other spaces<=300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. C405.2.1. Occupancy sensors control function in ❑Complies Exception: Requirement does not apply. 2 warehouses: In warehouses,the ❑Does Not [EL19]' lighting in aisleways and open areas is controlled with occupant sensors that ['Not Observable automatically reduce lighting power ENot Applicable by 50%or more when the areas are unoccupied.The occupant sensors control lighting in each aisleway independently and do not control lighting beyond the aisleway being controlled by the sensor. C405.2.1. Occupant sensor control function in ❑Complies Exception: Requirement does not apply. 3 open plan office areas: Occupant ❑Does Not [EL20]' sensor controls in open office spaces ❑Not Observable >=300 sq.ft. have controls 1) ❑Not Applicable e configured so that general lighting can PP be controlled separately in control ;zones with floor areas<=600 sq.ft. within the space, 2)automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space,3)are configured so that general lighting power in each 'control zone is reduced by>= 80%of the full zone general lighting power within 20 minutes of all occupants 'leaving that control zone, and 4)are configured such that any daylight responsive control will activate space general lighting or control zone general lighting only when occupancy for the same area is detected. C405.2.2, I Each area not served by occupancy ❑Complies Requirement will be met. C405.2.2. I sensors(per C405.2.1) have time- ❑Does Not 1, ;switch controls and functions detailed Location on plans/spec: E-1 C405.2.2. 'in sections C405.2.2.1 and C405.2.2.2.2 ONot Applicable [EL21]2 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 13 of 20 • Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.3, ;Daylight zones provided with DComplies Exception: Requirement does not apply. C405.2.3. individual controls that control the ODoes Not 1, ;lights independent of general area C405.2.3. ;lighting.See code section C405.2.3 DNot Observable 2 ;Daylight-responsive controls for ENot Applicable [EL23]2 ;applicable spaces, C405.2.3.1 Daylight responsive control function and ,section C405.2.3.2 Sidelit zone. C405.2.4 Separate lighting control devices for DComplies Requirement will be met. [EL26]1 specific uses installed per approved ODoes Not lighting plans. Location on plans/spec: E-1 DNot Observable ENot Applicable C405.2.4 Additional interior lighting power DComplies Requirement will be met. [EL27]1 allowed for special functions per the ODoes Not approved lighting plans and is ['Not Observable Location on plans/spec: E-1 automatically controlled and separated from general lighting. DNot Applicable C405.2.5 Automatic lighting controls for exterior ❑Complies Requirement will be met. [EL28]na0 .lighting installed.Controls will be ❑Does Not daylight controlled,set based on Location on plans/spec: E-1 business operation time-of-day,or DNot Observable reduce connected lighting>30%. ENot Applicable C405.3 Exit signs do not exceed 5 watts per DComplies Requirement will be met. [EL6]1 face. ODoes Not ❑Not Observable Location on plans/spec: E-1 DNot Applicable C405.6 Low-voltage dry-type distribution DComplies Exception: Requirement does not apply. [EL26]2 electric transformers meet the ODoes Not minimum efficiency requirements of Table C405.6. ['Not Observable DNot Applicable C405.7 ;Electric motors meet the minimum OComplies Requirement will be met. [EL27]2 efficiency requirements of Tables ODoes Not 'C405.7(1)through C405.7(4). ❑Not Observable Efficiency verified through certification :under an approved certification ❑Not Applicable !program or the equipment efficiency ratings shall be provided by motor 'manufacturer(where certification programs do not exist). C405.8.2, i Escalators and moving walks comply DComplies Exception: Requirement does not apply. C405.8.2. 'with ASME A17.1/CSA B44 and have ❑Does Not 1 "automatic controls configured to [EL28]2 reduce speed to the minimum DNot Observable permitted speed in accordance with ENot Applicable ASME A17.1/CSA B44 or applicable local code when not conveying passengers. C405.9 ;Total voltage drop across the DComplies Exception: Requirement does not apply. [EL29]2 ;combination of feeders and branch ❑Does Not circuits<=5%. ENot Observable ENot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 14 of 20 Section Insulation Inspection Complies? Comments/Assumptions & Req.ID C303.1 Roof insulation installed per ❑Complies Requirement will be met. [IN3]1 manufacturer's instructions. Blown or ❑Does Not poured loose-fill insulation is installed :Not Observable Location on plans/spec:A-1 only where the roof slope is<=3 in 12. DNot Applicable C402.2.1 Insulation installed on a suspended ❑Complies Exception: Requirement does not apply. [IN20]1 ceiling having ceiling tiles is not being ❑Does Not specified for roor/ceiling assemblies. Continuous insulation board installed ONot Observable in 2 or more layers with edge joints DNot Applicable offset between layers. C303.1 ;Building envelope insulation is labeled DComplies Requirement will be met. [IN1012 'with R-value or insulation certificate ❑Does Not providing R-value and other relevant data. DNot Observable ONot Applicable C303.2 Above-grade wall insulation installed ❑Complies Requirement will be met. [IN7]1 per manufacturer's instructions. DDoes Not DNot Observable Location on plans/spec:A-1 ONot Applicable C303.2.1 ;Exterior insulation is protected from ❑Complies Exception: Requirement does not apply. [IN14]2 I damage with a protective material. ❑Does Not I Verification for exposed foundation ;insulation may need to occur during ❑Not Observable !Foundation Inspection. ONot Applicable C402.1.3 Non-swinging opaque doors have R- ❑Complies Requirement will be met. [IN19]3 4.75 insulation. ❑Does Not ONot Observable Location on plans/spec:A-1 ONot Applicable C105 Installed above-grade wall insulation ❑Complies See the Envelope Assemblies table for values. [IN6]1 type and R-value consistent with ❑Does Not insulation specifications reported in plans and COMcheck reports. :Not Observable ❑Not Applicable C402.2.3 ;Installed floor insulation type and R- ❑Complies See the Envelope Assemblies table for values. [IN8]Z value consistent with insulation ❑Does Not specifications reported in plans and COMcheck reports. :Not Observable ❑Not Applicable C402.2.6 ;Radiant panels and associated ❑Complies Exception: Requirement does not apply. [IN18]3 components,designed for heat ODoes Not transfer from the panel surfaces to the :occupants or indoor space are :Not Observable insulated with a minimum of R-3.5. ❑Not Applicable C105 Installed roof insulation type and R- ❑Complies See the Envelope Assemblies table for values. [IN2]1 value consistent with insulation ❑Does Not specifications reported in plans and COMcheck reports. For some ceiling DNot Observable systems,verification may need to ONot Applicable occur during Framing Inspection. C402.5.1. All sources of air leakage in the ❑Complies Requirement will be met. 1 building thermal envelope are sealed, ❑Does Not [IN1]1 caulked,gasketed,weather stripped ONot Observable Location on plans/spec:A-1 or wrapped with moisture vapor- permeable wrapping material to ENot Applicable minimize air leakage. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 15 of 20 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 16 of 20 Section Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, Furnished O&M instructions for ❑Complies Requirement will be met. C408.2.5. 1 systems and equipment to the EDoes Not 2 ;building owner or designated [FI17]3 !representative. [Not Observable ONot Applicable C303.3, Furnished O&M manuals for HVAC DComplies Requirement will be met. C408.2.5. systems within 90 days of system ❑Does Not 3 acceptance. :Not Observable [F18]3 ONot Applicable C402.5.6 ;Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply. [FI37]1 I dock cargo door openings and provide ODoes Not direct contact along the top and sides of vehicles parked in the doorway. DNot Observable ONot Applicable C402.5.6 ;Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply. [FI37]1 :dock cargo door openings and provide ❑Does Not j direct contact along the top and sides ;of vehicles parked in the doorway. ONot Observable ONot Applicable C402.5.6 Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply. [F137]1 dock cargo door openings and provide ODoes Not direct contact along the top and sides of vehicles parked in the doorway. ❑Not Observable ONot Applicable C402.5.6 ;Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply. [FI37]1 :dock cargo door openings and provide ODoes Not direct contact along the top and sides I of vehicles parked in the doorway. :Not Observable ONot Applicable C402.5.8 ;Recessed luminaires in thermal ❑Complies Exception: Requirement does not apply. [FI26]3 !envelope to limit infiltration and be IC ODoes Not • rated and labeled.Seal between ONot Observable interior finish and luminaire housing. { ❑Not Applicable C403.2.2 ;HVAC systems and equipment ❑Complies Requirement will be met. [FI27]3 ;capacity does not exceed calculated ODoes Not loads. Location on plans/spec: M-1 ONot Observable ONot Applicable C403.2.4. ;Heating and cooling to each zone is ❑Complies 1 {controlled by a thermostat control. ODoes Not [FI47]3 ;Minimum one humidity control device ONot Observable I per installed humidification/dehumidification ❑Not Applicable ;system. C403.4.1. ;Thermostatic controls have a 5 °F ❑Complies Requirement will be met. 2 I deadband. ODoes Not [FI38]3 Location on plans/spec: M-1 ONot Observable ONot Applicable C403.2.4. ;Temperature controls have setpoint ❑Complies Requirement will be met. 1.3 ;overlap restrictions. ODoes Not [FI20]3 ' ❑Not Observable Location on plans/spec: M-1 ❑Not Applicable C403.2.4. ;Each zone equipped with setback ❑Complies Exception: Requirement does not apply. 2 controls using automatic time clock or ODoes Not [FI39]3 programmable control system. [Not Observable ONot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 17 of 20 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C403.2.4. ;Automatic Controls:Setback to 55°F DComplies Exception: Requirement does not apply. 2.1, (heat)and 85°F(cool); 7-day clock,2- ❑Does Not C403.2.4. hour occupant override, 10-hour 2.2 backup ONot Observable [F140]3 ONot Applicable C403.2.4. ;Systems include optimum start DComplies 2.3 controls. ODoes Not [FI41]3 [Not Observable DNot Applicable C405.4.1 Interior installed lamp and fixture DComplies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ODoes Not is shown on the approved lighting plans, demonstrating proposed watts ['Not Observable are less than or equal to allowed ONot Applicable ;watts. C405.5.1 ;Exterior lighting power is consistent DComplies See the Exterior Lighting fixture schedule for values. [F119]1 'with what is shown on the approved ODoes Not lighting plans,demonstrating proposed watts are less than or equal ONot Observable to allowed watts. DNot Applicable C408.1.1 Building operations and maintenance DComplies Requirement will be met. [FI57]1 documents will be provided to the ODoes Not owner.Documents will cover manufacturers'information, ONot Observable specifications, programming DNot Applicable procedures and means of illustrating to owner how building,equipment and systems are intended to be installed, maintained,and operated. C408.2.1 Commissioning plan developed by ❑Complies Requirement will be met. [FI28]1 registered design professional or ODoes Not approved agency. Location on plans/spec: M-1 ONot Observable DNot Applicable C408.2.3. 1 HVAC equipment has been tested to DComplies Exception: Unitary or packaged HVAC eqiupment without 1 ensure proper operation. ODoes Not supply air economizers. [FI31]1 ONot Observable ONot Applicable C408.2.3. HVAC control systems have been DComplies Requirement will be met. 2 tested to ensure proper operation, ODoes Not [FI10]1 calibration and adjustment of controls. DNot Observable Location on plans/spec: M-1 ONot Applicable C408.2.4 Preliminary commissioning report DComplies Requirement will be met. [FI29]1 completed and certified by registered ODoes Not design professional or approved DNot Observable Location on plans/spec: M-1 agency. ONot Applicable C408.2.5. !Furnished HVAC as-built drawings DComplies Requirement will be met. 1 !submitted within 90 days of system DDoes Not [FI7]3 ;acceptance. DNot Observable DNot Applicable C408.2.5. ;Furnished as-built drawings for DComplies Requirement will be met. 1 !electric power systems within 90 days ODoes Not [FI16]3 :of system acceptance. ONot Observable ONot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 18 of 20 Section Final Inspection Complies? Comments/Assumptions & Req.ID C408.2.5. An air and/or hydronic system ❑Complies Requirement will be met. 3 balancing report is provided for HVAC DDoes Not [FI43]1 systems. ❑Not Observable Location on plans/spec: M-1 ONot Applicable C408.2.5. {Final commissioning report due to DComplies Requirement will be met. 4 {building owner within 90 days of ❑Does Not [F130]1 :receipt of certificate of occupancy. ONot Observable Location on plans/spec: M-1 ONot Applicable C408.3 Lighting systems have been tested to ❑Complies Requirement will be met. [F133]1 ensure proper calibration,adjustment, ❑Does Not programming,and operation. ['Not Observable Location on plans/spec: E-1 { ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 19 of 20 Project Title: Garvey Hyundai Addition Report date: 07/27/22 Data filename: Y:\Garvey\Dix Ave Hyundai\Hyundai Dealship Renovations-2021\Garvey Hyundai Addition.cck Page 20 of 20