IM Inspection Worksheet_10-01-2024_11-49-44INSPECTION WORKSHEET (RESFINAL-000113-2024)
RC-0296-2023Case Number:Case Module:Permit Management
01/10/2024 PassedInspection Status:Inspection Date:
Residential Final InspectionInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:98 West Mountain Rd
Queensbury, NY 12804
315.6-1-18
Company Name NameContact Type
Applicant Cerrone Builders Inc
Contractor Cerrone Builders Inc
Engineer Vision Engineering
Granted Permission Cerrone Builders Inc
Primary Owner Cerrone Builders Inc
Checklist Item CommentsPassed
Low flow toilet 1.3 gal/flushing cycle True
Bathroom Fans, if no window True
3" Plumbing Vent through roof minimum 18 inch True
Grade away from foundation: 6" down, 10' out True winter conditions
Final Survey Plot Plan True
Window guards req:<2' above floor/6' above grade True
Interior privacy/trim/doors/main entrance 36 True
Backflow Preventors where required True
Basement wall insulation R- value verified True
Emergency egress below grade True
Intake Openings True
Safety glazing: w/in 5' of tub/shower True
Site Plan / Variance required False
Seals on Garage Doors, esp. Wood True
Attic Access Insulation = Attic R- Value True
Gas Shut-off Exposed & Regulator 12" min abv grd True
Platform at all exterior doors True
Garage Floor Pitched True
Wood deck: 2'+ from grade dia bracing required False N/A
Inter Connected True
Arc Fault Breaker Habitable Spaces True
Energy Sticker on Elec. Panel:R-Val. & Heating Sys True At furnace
Furnace/Hot Water Heater operating True
Hot water drain pan to indirect waste False N/A
Fresh Air Intake True
Basement stairs closed rise greater than 4 inches True
Outside every bedroom area True
Blower Door Test Certification True
Fin Elect; Energy Saving Light Bulbs 90 Percent True
January 10, 2024 Page 1 of 3
INSPECTION WORKSHEET (RESFINAL-000113-2024)
Checklist Item CommentsPassed
Heat detector in garage True
OK to Issue C/O True
Truss ID Signage Installed at Electrical Meter True
Range Hood 400+ cfm-Fresh Air REQUIRED False less than 400 cfm's
4 inch Building Number Address visible from road True
Attic Access Gasketed True
Jack posts in basement lagged at top and bottom True
Flood Plain Certification, if required False
Guard at deck, porches 36" or more False N/A
6" clearance to sill plate True
Crawl space/knee wall access insulated & gasketed True
5/8" Type X with Living Space Above True
Propane Tank: Proper Setback from Prop Line/Struct False
4+ Deck Joist Ledger Connections-24" From Ends False N/A
20 Minute Fire Door/Self-Closing Hardware True
Every level, Every bedroom True
Furnace shut-off w/in 30 ft. or w/in line of site True
Chimney Height / B Vent / Direct Vent Location True
within 10' of all sleeping areas True
on all levels w/gas appliances (i.e. furnace)True
Relief Valve ,Heat Trap/Water Temp 110 deg or less True
Electronic as-builts True
1/2" Gypsum or House Wall and Gable True
Basement Egress: 5s.f. window w/sill or Bilco door True
Duct work sealed properly True
Handrail Termination at Newell Post or Wall True
All Hot Water Systems: 3/4" or larger piping R-3 True
Plumbing fixtures True
Deck Ledger-Bolted per Code False N/A
Guard at stairwell at 34" or more True
Knee wall/Crawl space 18" x 24"True
Handrail 4 or more risers True
Carbon Monoxide Detectors:True
Interior/Exterior Railings 34 to 38 True
Battery backup True
Flex Gas Pipe Bonding True
Encl. Stairs Sheetrock Underside minimum ½ Gypsum False N/A
Foundation insulation to floor True
Outside Spigots have Air Gap True
Fresh air supply 3' from grade True
Smoke Detectors:True
As Built Septic System True
January 10, 2024 Page 2 of 3
INSPECTION WORKSHEET (RESFINAL-000113-2024)
Checklist Item CommentsPassed
Guards at stairs,decks,patios 30" + above grade True
Roof Complete / Exterior Finish Complete True
HRV or ERV Installed per Bedroom Requirements True
Bathroom / Kitchen Watertight True
Attic Access 22 x 30 minimum True
General Comments False