IM Inspection Worksheet_18-01-2024_11-26-49INSPECTION WORKSHEET (RPLUM-000286-2024) CC-0013-2023Case Number:Case Module:Permit Management 01/18/2024 Partial PassInspection Status:Inspection Date: Rough PlumbingInspection Type:Inspector:Mark Smith Job Address:Parcel Number:80 Main St Queensbury, NY 12804 309.10-1-25 Company Name NameContact Type Applicant FOOTHILLS BUILDERS, LLC Architect Rucinski Hall Architecture Contractor FOOTHILLS BUILDERS, LLC Granted Permission FOOTHILLS BUILDERS, LLC Primary Owner 78-80 Main Street LLC Checklist Item CommentsPassed Building Inspector Notes False 11/15/23 partial approval for rough plumbing. - 5 roof drains at the east side of building pressure tested and approved. 11/16/23 partial approval for rough plumbing: - Remaining 5 roof drains pressure tested and approved. 12/11/23 partial approval for rough plumbing. - sanitary drains and vents approved for rooms 308 thru 312 half of rooms 306 & 307 are included. 12/20/23 partial approval for rough plumbing. - remaining plumbing for sanitary drain and vents at the 3rd floor approved. - Domestic water supply at 3rd floor approved. - Main water line supplying 3rd floor approved. 1/2/24 partial approval for rough plumbing. - plumbing for domestic water supply at second floor approved. - main supply plumbing from first floor to second floor verified. 1/18/24 partial approval for rough plumbing. - Sanitary drains and vents at second floor approved. - Domestic water supply at second floor approved. - Sanitary drains and vents at laundry room approved. - Domestic water supply for laundry room approved. Pressure Test True Pressure Test True 3" Vent Through Roof - 18" min True Washing Machine Drain 2 inch minimum True All Return Air Hard Duct Work False 5 psi or 10 ft. above highest conn. for 15 minutes True third floor only Rough Plumbing / Nail Plates True Duct Testing Outside Conditioned Space False Shower liner test (2" of water)False Water Supply Piping True third floor only Duct Insulation - if required in unheated spaces False Duct work sealed properly False January 18, 2024 Page 1 of 2 INSPECTION WORKSHEET (RPLUM-000286-2024) Checklist Item CommentsPassed Cleanout every 100 feet change of direction False Plumbing Vent Vents in Place True Air Test Gas Piping 10 psi for 10 Minutes False Washing Machine Trap: 18"-42" discharge False Air Head True Air Head True 50 P.S.I for 15 minutes True 1 ½ inch minimum Drain Size True Drain Vent True Permit Card Visible From Road False January 18, 2024 Page 2 of 2