SEP-0005-2024 SEPTIC VARIANCE Office Use Only �.� Permit#:� -Oot j— 202 - APPLICATION Permit Fee: $ t Town of Cirecnibury Invoice#: tsb51 _ 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 ww.queensburvnet Approvals: w Submittal: 1 (one) original & 8 copies of the completed application package PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL Section 1: Contact Information: Property Owner(s): SUN-AE BENSON Owner's Agent: HUTCHINS ENGINEERING,PLLC Address: 3 ORIENT AVENUE Address: 169 HAVILAND ROAD BROOKHAVEN,NY 11719 QUEENSBURY,NY 12804 Phone#: Phone#: 518-796-2515 Email: Email: TCENTER@HUTCHINSENGINEERING.COM Section 2: Site Information: Site Address: 371 GLEN LAKE ROAD Tax ID#: 289.10-1-1 Directions to Site: NORTH SIDE OF GLEN LAKE ROAD BETWEEN SULIIVAN DRIVE & ELM DRIVE Section 3: Distance from well on property to septic system (if applicable) 116' feet Section 4: Is it possible to install a conforming septic system on this property? ❑Yes 0 No If YES, please explain and attach a diagram: Section 5: Does the proposed system meet setback requirements for distance from wells&septic systems on neighboring properties? MYes ❑ No If NO, please explain: Section 6: Is the proposed system to be installed under a parking area? ❑Yes 0 No Section 7: Section of the Sanitary Sewage Ordinance from which you are seeking the variance (i.e. leaching system will be 89 ft. -- from well in lieu of required 100 ft.): PLACE ABSORPTION FIELD 8 FT FROM EAST PROPERTY LINE IN LIEU OF 10 FT REQUIRED&6 FT FROM STRUCTURE IN LIEU OF 20 F[REQUIRED. Septic Variance Application Revised December 2021 Section 8: List the names, parcel addresses, and tax map numbers of all adjoining property owners. You may obtain this information from the Town of Queensbury's Assessor's Office: North Name • QUEENSBURY LAND CONSERVANCY/SUN-AE BENSON Address 169 HAVILAND RD, QUEENSBURY/ SAME AS OWNER Tax Map ID 289.9-1-65 / 289.6-1-4 South Name GARY HILLERT TRUST Address 366 GLEN LAKE RD QUEENSBURY Tax Map ID 289.10-1-53 East Name FRANCIS DONOHUE Address 40 RED WOOD TREE LANE, IRVINE CA 92612 Tax Map ID 289.10-1-2 West Name SANDRA STROTHER Address 357 GLEN LAKE ROAD, QUEENSBURY Tax Map ID 289.9-1-64 Section 9: OWNER STATEMENT I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: . I/We realize that putting the well, septic tank or leaching system less than the required feet from the may increase the risk of pollution. • Owner—Print Name: Owner—Signature: Date: Section 10: NEIGHBOR OR TENANT RELEASE STATEMENT(if applicable) I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: . I/We realize that putting the well, septic tank or leaching system less than the required feet from the may increase the risk of pollution. Neighbor/Tenant—Print Name: •. Neighbor/Tenant-Signature: Date: Septic Variance Application Revised December 2021 • PLEASE ATTACH THE FOLLOWING TO YOUR APPLICATION: 1. A location map showing the site within the Town of Queensbury 2. A plot plan showing existing and proposed features of the property, including: a. Lot dimensions b. North arrow and scale: 1 inch=40 feet c. Location & dimensions of existing and proposed buildings, showing setback distances and uses d. Parking layout to scale (if applicable) e. Physical features (street, steep slopes, lakes, wetlands, etc.) f. Location of all wells and septic systems on neighboring properties g. Adjacent ownerships h. All properties within 500 feet A sample plot plan and location are shown below: I III , aC'wv: i I • ! ro 1 "tr., I /r ..-,,/ La I 07. ' yiYs c'\ -- Cin /S yT _ I rf k,;r. ,„" iVr.•. ( r a�' w s . I ' � / ph r j44 wax: w.+ t lt...„.. i 1 s(---9, 1 / ? a7.c:;er,ea a; c TcAn Caieaa �# P 1 J/.L ._. U Y a ! / / _ °,�,,,w, _=--- -=_ ,— ' T t - ` //lye i �8 - •1 «,,mow2 it .i> Septic Variance Application Revised December 2021 Section 11: AUTHORIZATION AND SIGNATURE PAGE This page includes the Authorization to Act as Agent form, engineering fee disclosure, authorization for site visits, other permit responsibilities and agreement to provide documentation required. Complete the following if the OWNER is using an Agent: Owner's Name: SUN-AE BENSON Designates: HUTCHINS ENGINEERING as agent regarding the Septic Variance for Site Address: 371 GLEN LAKE ROAD Tax Map#: 289.1-1-1 Engineering Fee Disclosure:Applications may be referred to the Town consulting engineer for review of septic design, storm drainage, etc. as determined by the Town Board of Health. Fees for engineering review services will be charged directly to the applicant. Authorization for Site Visits: By signing this page and submitting the application materials attached herein,the Owner, Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code Enforcement Officers and Town Engineer to enter the subject properties for the purpose of reviewing the application submitted. Please Note: Other permits may be required for construction or alteration activity subsequent to approval by the Town Board of Health. It is the applicant's responsibility to obtain any additional permits. Official Meeting Minutes Disclosure: It is the practice of the Town Board of Health to have a designated stenographer tape record the proceedings of the meetings resulting from the application, and that the minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy between such record and the handwritten minutes taken by the designated stenographer,the handwritten minutes shall be deemed the official record. I,the undersigned, have thoroughly read and understand the instructions for submission; agree to the submission requirements and completed checklist: OWNER—PRINT NAME: OWNER—SIGNATURE: DATE: AGENT—PRINT NAME: THOMAS CENTER, PE - HUTCHINS ENGINEERING, PLLC DATE: 1/3/2142416gt AGENT—SIGNATURE: Septic Variance Application Revised December 2021 169 Haviland Road Queensbury, NY 12804 Hutchins Engineering PLLC Phone: (51 )745-0307 45-0308 January 3, 2024 Town of Queensbury Town Board 4 Board of Health . ' �',' 742 Bay Road Queensbury NY 12804 1. JAN 03 2024 Re: Sun-ae Benson 371 Glen Lake Road TOWN OF l=L:NSaURY BUILDING 8; CODES Tax Map ID: 289.10-1-1 Dear Supervisor Strough &Town Board Councilmen: This office represents Sun-ae Benson with respect to the pursuit of wastewater variances for a replacement wastewater system installation at their property located at 371 Glen Lake Road. Presently the 1-bedroom cottage is served by a 1,000-gallon concrete septic tank and a 4 ft x 4 ft drywell. During the property transfer inspection, it was discovered that the existing drywell is within the 150 ft setback of a neighboring well. Given the terrain and site constraints, it is not possible to install a compliant wastewater system. We are proposing to install a new 10 ft wide by 25 ft long stone absorption bed in the southeast corner of the property. Relief is requested for the installation absorption field fill within 8.ft of the east property line where 10 ft is required and within 6 ft of the structure where 20 ft is required. The existing cottage is built on piers with a shallow crawl space. Enclosed please find ten submission packages for this project. We respectfully request, if possible, that this item be placed on the agenda of the next town board meeting. Please contact me if you have any questions or if you require additional information. Best Regards, Thomas R. Center Jr., P.E. Associate - Design Engineer 00"E 26, 52'`_ 23.9E T_ S ---80'83 3Y E low / 702.49 i AREA L / S- C;F--7 k 8, 724. 57± sq. ft. 0.43± acres oh /} ooCO� �� � X Q o o V�zi/ i j Oh ® 40 114" PER FOOT MIN. SLOPE 4" HOUSE SEWER WATERTIGHT SLEEVE & SEAL (TYP.) SEPTIC TANK NOTES EXISTING SEPTIC TANK TO BE PUMPED, INSPECTED AND RE -USED IF IN ACCEPTABLE CONDITION, EXPOSE BOTH INLET AND OUTLET PORTS, VERIFY BAFFLES, AND REPLACE WITH 4" PIPE TEE BAFFLES IF NECESSARY. INSTALL RISER TO GRADE ABOVE OUTLET PORT. 1 A/ A !`Tr-1 A/ A Tr-1'1 [111['`TrAA n 1.-n1 A/ r A A CA IT n► A A .?L^LL. 1 —LV GRAPHIC SCALE 10 0 5 10 20 40 ( IN FEET ) CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES. 12" MIN. COVER ad ]Tr � 3" o LIQUID LEVEL 16" 18" MIN. 1 e LIQUID DEPTH a 30 MIN. ,a 60 MAX. a a MINIMUM 2X WIDTH e MAXIMUM 4X WIDTH e a EXISTING 1,000 GALLON PRECAST CONCRETE SEPTIC TANK INSTALLER TO EXPOSE BOTH INLET AND OUTLET PORTS OF EXISTING TANK TO VERIFY BAFFLES AND TANK INTEGRITY EXITING SEPTIC TANK DETAIL SCALE: NTS SUGGESTED: POLYETHYLENE EXTENSION TO GRADE WITH TAMPER RESISTANT ACCESS COVER (NON -TRAFFIC AREAS 118" PER FOOT MIN. SLOPE 4" EFFLUENT SEWER 12" MIN. COVER DISTRIBUTION BOX BAFFLE USE SPEED LEVELERS TO ASSURE ALL OUTLETS ARE AT EXACTLY THE SAME ELEVATION 2"MIN. 4" PVC SDR-35 SOLID HEADER TO ABSORPTION LATERALS, 118" PER FOOT MIN SLOPE 2"MIN. DROP BETWEEN INVERTS No Septic Or Wells Found VARIANCE SUMMARY ABSORPTION FIELD TO EAST PROPERTY LINE 10' REQUIRED 8' PROPOSED 2' RELIEF REQUESTED ABSORPTION FIELD TO RESIDENCE 20' REQUIRED 6' PROPOSED 14' RELIEF REQUESTED LIMIT OF 10'x25' STONE BED APPROXIMATE EXISTING GRADE SITE SOILS DATA TEST PIT TP-1-1112012023 BY TOM CENTER, P. E. 0-11 " - TOPSOIL 11-31 " LOAMY MEDIUM FINE SAND 31-67" MEDIUM FINE SAND NO MOTTLING OR GROUNDWATER OBSERVED PROVIDE 24" VERTICAL SEPARATION TO BOUNDARY CONDITION PERCOLATION TEST PT-1-1112012023 BY TOM CENTER, P. E. STABILIZED PERCOLATION RATE - 3 MIN 30 SEC @ 24" IN 30" HOLE 10' BED WIDTH E—EnOI7E SLOPE--4 / i T T 2' MIN. USABLE SOIL BACKFILL MATERIAL AS NEEDED 10'x25' CRUSHED STONE TO ESTABLISH GRADES ABSORPTION BED ABSORPTION BED SECTION NTS 4" MINIMUM TOPSOIL ON ENTIRE BACKFILL AREA; SEED AND ESTABLISH TURF 25' BED LENGTH F—EAOIIE SLOPE NTS 25' ' ABSORPTION BED PLAN NTS PROPOSED DISTRIBUTION BOX TRANSITION FORCE MAIN TO 4" PVC OUTSIDE OF D-BOX 4" MINIMUM TOPSOIL ON ENTIRE BACKFILL AREA; SEED AND ESTABLISH TURF APPROXIMATE EXISTING GRADE FILTER FABRIC, TENCATE MIRAFI 140N OR EQUIVALENT 289.10-1-1 SEP-OOOS-2024 Benson, Sun-ae 371 Glen Lake Rd Septic Variance/Alteration IF�rrz BAN 0 3 2024 T® 0FBUILD/ G Qt1��t, MAP REFERENCE: 1. BASE MAP INFORMATION FROM "MAP OF A SURVEY MADE FOR WILLIAM P. BENSON," IN THE TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK. DATED OCTOBER 22, 2009. LAST REVISED MARCH 29, 2021. PREPARED BY VAN DUSEN & STEVES LAND SURVEYORS. WASTEWATER SYSTEM SETBACK REQUIREMENTS PROPERTY LINE HOUSE STREAM, LAKE, WATERCOURSE, WETLAND WELL SEPTIC TANK 10' 10' 50' 50' ABSORPTION FIELD 10' 20' 100' 100' Dig a Safely. Newyork Call Before You Dig Wait The Required Time p Confirm Utility Response p Respect The Marks Dig With Care 800.962-7962 www.digsafelynewyork.com N N o � P O 0 ® 0 Z ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. Hutchins Engineering PLLC 169 Hoviland Road Queensbury, NY 12804 (518) 745-0307Phone (518) 745-0308 Fox TAX MAP # 289.10-1-1 WASTEWATER SYSTEM REPLACEMENT PLAN & DETAILS prepared for: Sun-ae Benson 371 Glen Lake Road Town of Queensbury, County of Warren, State of New York Drawn: AVAIWGC lChecked., TRC Scale: NOTED IDate. 1112012023 2922 74— 01-Sl SEPTIC DISPOSAL PERMIT Office Use Only APPLICATION Permit#: '0 —20 1 Town of ucens'bory qq J Q- tt Permit Fee:$ O� [, a 9 Invoice#: 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.Queensburv.net :::: APR 1 qqrb1ne. TOWN OF QUEENSBURY Wetlands? Yes Reviewed By: 6-4_ 'C) BUILDING& CODES Project Location: 371 GLEN LAKE ROAD —1 Tax Map #: 289.10-1-1 RESIDENCE INFORMATION: Year Built Gallons #of bedrooms: X gallons per =total daily flow per day bedroom Garbage Grinder Yes No 1980 or older 150 Installed? (choose one) x _ J 1981-1991 130 Spa or Hot Tub Yes No 1992-Present 110 1 110 110 Installed? (choose one) PARCEL INFORMATION: Topography • Flat Rolling n Steep Slope % Slope Soil Nature ❑ Sand n Loam Clay U Other, explain: Groundwater At what depth? 57"+ Bedrock/Impervious material At what depth? 57"+ Domestic Water Supply Municipal ■ Well Lake (if well or lake, water supply from any septic system absorption is 115 ft.) -Percolation Test Rate: 3.5 per minute per inch (test to be completed by a licensed engineer/architect) PROPOSED SYSTEM INFORMATION: Tank size EX1000 gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field w/#2 stone Total length ft.; Each Trench ft. Seepage Pit w/#3 stone How many: ; Size: Alternative System Bed or other type: 1o'X 25' BED Holding Tank System Total required capacity? tank size ; # of tanks Septic Application Revised July 2022 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): SUN-AE BENSON Mailing Address, C/S/Z: 3 ORIENT AVENUE,BRROKHAVEN,NY 11719 Cell Phone: 67‘,) ;1a, 3n('7 Land Line: Email: • Primary Owner(s): Name(s): SAME AS APPLICANT Mailing Address, C/S/Z: Cell Phone:&/6)- �,�j 30�� Land Line: Email: ❑ Check if all work will be performed by property owner only • Contractor: Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: Land Line: Email: **Workers' Comp documentation must be submitted with this application** • Engineer(s): Name(s): HUTCHINS ENGINEERING, PLLC Mailing Address, C/S/Z: 169 HAVILAND RD,QUEENSBURY,NY 12804 Cell Phone: 518-796-2515 Land Line: Email: TCENTER@HUTCHINSENGINEERING.COM Contact Person for Compliance in regards to this project: MIKE SCHUSTERITSCH Cell Phone: 518-307-3014 Land Line: Email: �..r Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal' Ordinance. �' , PRINT NAME: O I/C--d'l ki l` 1'lV L !� l � �/ }c. SIGNATURE: ;�' DATE: -th9/ 211 Septic Application Revised July 2022 { • • 5Dc7,6O .— 2 • • TOWN OF QUEENSBURY „o, 742 Bay Road, Queensbury,NY. 12804-5902 • • • Septic System Checklis • t • lan to scale . • 74 Received Deep hole pert test results from engineer/Architect if applicable Tow • • Architects;June 30 to April 15 Town Engineer for unapproved Engineers and Archit c Approved Engineers and ) wells on property and adjacent properties shown ,Water line shown Municipal 0 0'separation to any part of system AP Setback to property lines show 10'or more for any part of system /4i t septic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10'from any waterline • N lseptic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required(field verification required) %eptic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each AV�Leech Field 20'from foundation 100'from any well 10'from water line /0 14Seepage pit 150'from-well 50'from septic tank P4Seepage Pits 3-times diameter apart • lSeptic tank and pump stations over 30 gallons 50'from watercourse or wetland • � • //4 . distance from bottom of trench or system 24"to bedrock or mottling 36"within 1000'of Lake George • 16c Leech field 100' from watercourse or wetland r f- .e of mound or bottom of retaining wall.10'from property line 100'from well 20'from Foundation ttProvide'Engineer/Architect stamp for bed or design systems • . . 141 Department of Health Approval for all mobile home park new systems Flood Plain requirements • /' 2'above established flood elevation to bottom of system • 12All tanks anchored or 2'above flood elevation 09, _p 26. 52 , 1 23 96 S 80° 63 31„ E BqC of � "��'� ® AREA °/O ®S 0' P 1 8, 724.57± sq. ft. �T ACK '`��/y hry 0.43± acres ya� ��� `l I 40 l P o �� k QCoGG� / ���U� / / % e / 'EXIS71NG 1,000 GALLON SEPTIC TANK ® / TO BE PUMPED, INSPECTED, w ' ' 6.00' '/ k AND REUSED IF SUITABLE. Tp.1 k 143.80, ® 'y0 PT-1 % ` 8.0' No Septic IV-10,� z ' ° �0' P,L T SF / Or Wells Found 1 Op ,W 20 00 ® 40, 03, 1 PROPOSED 10 x25 ABSORP110N BED ®® N 6�0.�3 WASTEWATER SYSTEM REPLACEMENT PLAN ®®'°'® Pump House \ 1 SCALE 1 "=20' 77 GRAPHIC SCALE 10 0 5 10 20 40 ( IN FEET ) CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES. APPROXIMATE EXISTING GRADE 10' BED WIDTH F—SLOPE SLOPE--i 2' MIN. USABLE SOIL BACKFILL MATERIAL AS NEEDED— J \-10'x25' CRUSHED STONE TO ESTABLISH GRADES ABSORPTION BED ABSORPTION BED SECTION NTS 4" MINIMUM TOPSOIL ON ENTIRE BACKFILL AREA; SEED AND ESTABLISH TURF 25' BED 4" MINIMUM TOPSOIL ON ENTIRE BACKFILL AREA; SEED AND ESTABLISH TURF LENGTH SLOPE SLOPE—i, 10 APPROXIMATE EXISTING GRADE 4" SDR-35 PVC PERFORATED LATERAL — FILTER FABRIC, TENCATE MIRAFI INSTALLED NEAR LEVEL, IN BED 140N OR EQUIVALENT CONFIGURATION ABSORPTION BED PROFILE NTS LIMIT STON 10' 25' v ABSORPTION BED PLAN NTS PROPOSED DISTRIBUTION BOX TRANSITION FORCE MAIN TO 4" PVC I OUTSIDE OF D-BOX 1/4" PER FOOT MIN SLOPE 4" HOUSE SEWER WATERTIGHT SLEEVE & — SEAL (TYP.) SEPTIC TANK NOTES EXIS71NG SEP77C TANK TO BE PUMPED, INSPECTED AND RE -USED IF IN ACCEPTABLE CONDI710N. EXPOSE B07H INLET AND OUTLET PORTS, VERIFY BAFFLES, AND REPLACE WITH 4" PIPE TEE BAFFLES IF NECESSARY. INSTALL RISER TO GRADE ABOVE OUTLET PORT. WASTEWATER SYSTEM DESIGN I -BEDROOM RESIDENCE DESIGN FLOW - 110 GPD16EDROOM SYSTEM DESIGN FLOW - 110 GPD SEPTIC TANK - EXISTING 1,000 GAL. CONCRETE TANK DESIGN APPLICATION RATE: .9 GPDISF, BASED ON 3 MINIIN PERCOLA77ON RATE ABSORPTION BED AREA REO''D- = (110 GPD)1(.9 GPD/SF) = 122 SF BED AREA PROVIDED = 10'x25' = 250 SF POTABLE WATER SUPPLY IS TO BE ON -SITE WELL MAINTAIN 50' MINIMUM SEPARATION BETWEEN SEPTIC TANK & WELL MAINTAIN 100' MINIMUM SEPARATION BETWEEN ABSORPTION FIELD & WELL VARIANCE SUMMARY ABSORPTION FIELD TO EAST PROPERTY LINE 10' REQUIRED 8' PROPOSED 2' RELIEF REQUESTED ABSORPTION FIELD TO RESIDENCE 20' REQUIRED 6' PROPOSED 14' RELIEF REQUESTED SITE SOILS DATA Dig ®Safely. New TEST PIT ®York TP-1 -11 20 2023 BY TOM CENTER P. E. Ell Ca11 Before You Dig 01 Wait The Required 0-11 " - TOPSOIL AA Time ® Confirm Utility Response 0 Respect The arks I1-31 " LOAMY MEDIUM FINE SAND M Dig W With Care "� 31 67 - MEDIUM FINE SAND 800.962.7962 www.digsafeiynewyork.com NO MOTTLING OR GROUNDWATER OBSERVED r,> PROVIDE 24' VERTICAL SEPARATION TO } BOUNDARY CONDITION o o PERCOLATION TEST {@y3xi� l �iC o r ! 0 PT-1 -1112012023 BY TOM CENTER, P. E. 0Arc�t"� STABILIZED PERCOLATION RATE - 3 MIN 30 SEC @ 24" IN 30" HOLE V RESOLUTION APPROVING SUN-AE BENSON'S APPLICATION FOR SANITARY SEWAGE DISPOSAL VARIANCES RESOLUTIONVO.: BOH 4, 2024 INTRODUCED BY: Mr. Michael Dixon WHO MOVED ITS ADOPTION SECONDED BY: Mr. Anthony Metivier WHEREAS, Sun-ae Benson (Applicant) filed an application for variances from Chapter 136 to install a replacement wastewater treatment system with its absorption field fill to be located within: 1. 8' of the east property line in lieu of the required 10' setback; and 2. 6' of the structure in lieu of the required 20' setback; on property located at 371 Glen Lake Road in the Town of Queensbury, and WHEREAS, the Town Clerk's Office published the Notice of Public Hearing in the Town's official newspaper and the Local Board of Health duty conducted a public hearing concerning the variance request on Monday, January 22"d, 2024, and WHEREAS, the Town Clerk's Office has advised that it duly notified all -property owners within 500 feet of the subject property, NOW, THEREFORE, BE IT RESOLVED, that 1, due to the nature of the variances, the Local Board of Health determines that the variances would not be materially detrimental to the purposes and objectives of this Ordinance or other adjoining properties nor otherwise conflict with the purpose and SITE LOCATION TOWN OF QUEENSBURY BUILDING Based on ourI mited e apminnat on,Ncompliance with our comments shall not be construed as indicating the plans and specifications are in �ai �> , ,�,g full compliance with the Building Codes of TOWN' 1,J E E N S B U RY New York State. BUIL.:i,4G t D D g Date. _-�. s=. objectives of any Town plan or policy; and 2. the Local Board of Health finds that the granting of the variances is necessary for the reasonable use of the land and are the minimum variances which would alleviate the specific unnecessary hardship found by the Local Board of Health to affect the Applicant; and BE IT FURTHER, RESOLVED, that the Local Board of Health hereby approves Sun-ae Benson's application for variances from the Sewage Disposal Ordinance to install a replacement wastewater treatment system with its absorption field.fill to be located within: 1. 8' of the east property line in lieu of the required 10' setback; and 2. 6' of the structure in lieu of the required 20' setback; on property located at 371 Glen Lake Road in the Town of Queensbury and bearing Tax Map No: 289.40-1-1. Duly adopted this 22"d day of January, 2024, by the following vote: AYES : Mr. Metivier, Mr. Dixon, Mr, McNulty, Mr. Strough YOES :None ;'ABSENT: Mr. Freer v I, Betty Murphy, Deputy Town Clerk of the Town of Queensbury, Warren County, New York, do hereby certify that I have compared the foregoing with the original resolution as listed above adopted at a regular meeting of the Town Board of the Town of Queensbury held on the 2211 day of January, 2024 at which a quorum was present and that the same is a correct transcript therefrom and of the whole original thereof to date. 1J WITNESS THEREOF, I have hereto set my hand and the SEAL of said Town of Queensbury, this 23'a day of •January, 2024. SEAL SIGNED: Be , urph D u Town Clerk Town of Queensbury PUBLICATION DATE: January 13, 2024 L1 u J SUGGEST. POLYETHYLENE EXTENSGRADE WITHE TAMPER RESISTANT ACCESSION CCE SNCOVER l� TO (NON -TRAFFIC AREAS) APR 11 2024 T0p vi,.! OF 101UEE SJ B LtiLLdin�lr'i, 12 MIN. COVER 118" PER FOOT 12" MIN. COVER 289-10-1-1 SEP-0005-20 24 3" MIN. SLOPE DISTRIBUTION BOX Benson, Sun-ae ---� I 371 Glen Lake Road LIQUID LEVEL 4" EFFLUENT SEWER 1 i j-- Septic variance/alteration 16" 18" MIN. d LIQUID DEPTH 30" MIN. 60" MAX. MINIMUM 2X WIDTH MAXIMUM 4X WIDTH a a o d a .a c EXISTING 1,000 GALLON PRECAST CONCRETE SEPTIC TANK INSTALLER TO EXPOSE BOTH INLET AND OUTLET PORTS OF EXISTING TANK TO VERIFY BAFFLES AND TANK INTEGRITY EXITING SEPTIC TANK DETAIL SCALE: NTS BAFFLE USE SPEED LEVELERS TO ASSURE ALL OUTLETS ARE AT EXACTLY THE SAME ELEVATION 0 4" PVC SDR-35 SOLID HEADER TO ABSORPTION LATERALS, 1/8" PER FOOT MIN SLOPE 2"MIN. 2"MIN. DROP BETWEEN INVERTS MAP REFERENCE: 1. BASE MAP INFORMATION FROM "MAP OF A SURVEY MADE FOR WILLIAM P. BENSON," IN THE TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK. DATED OCTOBER 22, 2009. LAST REVISED MARCH 29, 2021. PREPARED BY VAN DUSEN & STEVES LAND SURVEYORS. WASTEWATER SYSTEM SETBACK REQUIREMENTS PROPERTY LINE HOUSE STREAM, LAKE, WA7ERCOURSE, WETLAND WELL SEPTIC TANK 10' 10' 50' 50' ABSORPTION FIELD 10' 20' 100' i 100' ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. Hutchins Engineering PLLC 169 Haviland Road Queensbury, NY 12804 (518) 745-0307 Phone (518) 745-0308 Fox TAX MAP # 289.10-1-1 WASTEWATER SYSTEM REPLACEMENT PLAN & DETAILS prepared for: Sun-ae Benson 371 Glen Lake Road Town of Queensbury, County of Warren, State of New York Drawn: AV*WGC Checked. TRC Scale: NOTED Date. 1112012023 2922 74— 01-S1