Loading...
IM Inspection Worksheet_24-01-2024_15-09-55INSPECTION WORKSHEET (RESFINAL-000365-2024) RC-0556-2021Case Number:Case Module:Permit Management 01/24/2024 PassedInspection Status:Inspection Date: Residential Final InspectionInspection Type:Inspector:Charles Dyer Job Address:Parcel Number:195 Assembly Point Rd Lake George, NY 12845 226.19-2-1 Company Name NameContact Type Applicant John Graziano Architect Beardsley Architects & Engineers James Brown Contractor Crandall Excavating Granted Permission John Graziano Primary Owner John Graziano Checklist Item CommentsPassed Low flow toilet 1.3 gal/flushing cycle True Bathroom Fans, if no window True 3" Plumbing Vent through roof minimum 18 inch True Grade away from foundation: 6" down, 10' out True Final Survey Plot Plan False Window guards req:<2' above floor/6' above grade True Interior privacy/trim/doors/main entrance 36 True Backflow Preventors where required True Basement wall insulation R- value verified True R 15 Intake Openings True Safety glazing: w/in 5' of tub/shower True Site Plan / Variance required False Provide engineer asbuilt certification for site / received Seals on Garage Doors, esp. Wood True Attic Access Insulation = Attic R- Value True Gas Shut-off Exposed & Regulator 12" min abv grd True Propane Platform at all exterior doors True Garage Floor Pitched True Wood deck: 2'+ from grade dia bracing required True Inter Connected True Arc Fault Breaker Habitable Spaces True Energy Sticker on Elec. Panel:R-Val. & Heating Sys True Furnace/Hot Water Heater operating True Fresh Air Intake True Basement stairs closed rise greater than 4 inches True Outside every bedroom area True Fin Elect; Energy Saving Light Bulbs 90 Percent True Gas Log In Sealed or Glass Enclosure True Existing fireplace OK to Issue C/O True Items completed / OK to Issue C/O Truss ID Signage Installed at Electrical Meter True Stick framed January 24, 2024 Page 1 of 3 INSPECTION WORKSHEET (RESFINAL-000365-2024) Checklist Item CommentsPassed Range Hood 400+ cfm-Fresh Air REQUIRED True 4 inch Building Number Address visible from road True On mail box Attic Access Gasketed True Jack posts in basement lagged at top and bottom True Existing Guard at deck, porches 36" or more True 6" clearance to sill plate True 5/8" Type X with Living Space Above True Propane Tank: Proper Setback from Prop Line/Struct True 4+ Deck Joist Ledger Connections-24" From Ends True 20 Minute Fire Door/Self-Closing Hardware True Every level, Every bedroom True Furnace shut-off w/in 30 ft. or w/in line of site True within 10' of all sleeping areas True Relief Valve ,Heat Trap/Water Temp 110 deg or less True 1/2" Gypsum or House Wall and Gable True Bathroom / Kitchen Watertight True HRV or ERV Installed per Bedroom Requirements True Duct work sealed properly True Provide duct sealing / or if sealed at interior of ducts, provide certification Completed / verified with mastic Foundation insulation to floor True As Built Septic System True Engineer asbuilt report has been received 8/23/22 Outside Spigots have Air Gap True OK to Issue Temporary C/O False Conditions for temporary C/O : complete windows/siding, complete duct sealing,Provide site plan certification, provide engineer septic asbuilt, provide site plan certification Permit has expired, renew permit Windows / siding / sealing of ducts verified 4/27/23 Provide site plan certification in order to close out permit All Hot Water Systems: 3/4" or larger piping R-3 True Battery backup True Carbon Monoxide Detectors:True Handrail 4 or more risers True Interior/Exterior Railings 34 to 38 True Roof Complete / Exterior Finish Complete True Complete siding at lakeside when windows installed Completed / verified 4/27/23 Handrail Termination at Newell Post or Wall True Plumbing fixtures True General Comments True Engineer asbuilt report received for septic system Guards at stairs,decks,patios 30" + above grade True Guard at stairwell at 34" or more True Fresh air supply 3' from grade True Attic Access 22 x 30 minimum True 3' from Baths True Smoke Detectors:True January 24, 2024 Page 2 of 3 INSPECTION WORKSHEET (RESFINAL-000365-2024) Checklist Item CommentsPassed Deck Ledger-Bolted per Code True January 24, 2024 Page 3 of 3