INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0056-2022 Case Module:
Inspection Date: February 09, 2024 Inspection Status: Reinspect
Inspector: Mark Smith Inspection Type: Residential Final
Job Address: 1481 BAY RD
, Parcel Number:
Contact Type Company Name Name
Checklist Item
Status
Smoke Detectors: PASS
Inter Connected PASS
Guards at stairs,decks,patios 30" + above
grade PASS
Battery backup PASS
As Built Septic System PASS
Basement wall insulation R- value verified PASS
Low flow toilet 1.3 gal/flushing cycle PASS
Basement stairs closed rise greater than
4 inches PASS
Propane Tank: Proper Setback from Prop
Line/Struct PASS
Basement Egress: 5s.f. window w/sill or
Bilco door PASS
on all levels w/gas appliances (i.e.
furnace) PASS
Guard at stairwell at 34" or more PASS
Final Survey Plot Plan PASS
OK to Issue C/O FAIL
Interior/Exterior Railings 34 to 38 PASS
Roof Complete / Exterior Finish Complete complete exterior siding and trim PASS
Jack posts in basement lagged at top and
bottom PASS
General Comments
8/3/23 final residential inspection not approved, please address the items
listed below and call for recheck. - provide an updated manual S & J showing
the change to geo thermal heating and cooling equipment. - provide third
party sign off for installation of geo thermal heating system -a final inspection
by the Fire Marshal for the wood burning stove is required -condensate line
can not drain into the floor drain in basement. -thermostat needs installed in
main house. -provide blower door test results. -provide proof of final electrical
inspection. -basement ceiling will need to be sheet rocked or an approved
thermal barrier to cover insulation. complete exterior trim, siding, and soffits.
complete interior trim, installation of doors, and work at upstairs bathroom. -
ridged insulation at exterior of foundation will need to be covered or cut below
grade. - A final inspection by Code Compliance Officer Bruce frank will be
required. 8/9/23 partial approval for final inspection. -Approved for temporary
certificate of occupancy only. complete the items listed below for final
approval - provide a updated manual S&J showing the change to geo
thermal heating and cooling system - Provide third party sign off of installation
of geo thermal systems, - condensate line cannot drain in to floor drain in
basement. - install thermostats in there permanent locations. - Basement
ceiling will need to be sheet rocked or have an approved 20 minute thermal
barrier installed to cover the insulation. - Complete exterior trim siding and
soffits. - complete interior trim, install doors, work in up stairs bath room,
install permanent guards at stairs and loft at second floor. - ridged insulation
at exterior foundation will need to be covered or cut below grade. - final
approval from Code Compliance Officer Bruce Frank 2/8/24 partial approval
for final residential inspection. - provide updated manual S& J for changes at
the heating system - provided third party sign off for the geothermal heating
system that was installed by the homeowner. - final inspection and sign off
from Zoning dept. FAIL
Handrail 4 or more risers PASS
Handrail Termination at Newell Post or
Wall PASS
HRV or ERV Installed per Bedroom
Requirements PASS
Grade away from foundation: 6" down,
10' out complete site work PASS
Carbon Monoxide Detectors: PASS
4+ Deck Joist Ledger Connections-24"
From Ends PASS
Wood deck: 2'+ from grade dia bracing
required PASS
Furnace/Hot Water Heater operating PASS
OK to Issue Temporary C/O PASS
Not less than 3' horiz from opening of
bthrn PASS
Arc Fault Breaker Habitable Spaces PASS
Bathroom Fans, if no window PASS
Outside Spigots have Air Gap PASS
3" Plumbing Vent through roof minimum
18 inch PASS
Duct work sealed properly PASS
Fin Elect; Energy Saving Light Bulbs 90
Percent common wealth PASS
All Hot Water Systems: 3/4" or larger
piping R-3 PASS
Gas Shut-off Exposed & Regulator 12"
min abv grd PASS
6" clearance to sill plate PASS
Interior privacy/trim/doors/main entrance
36 PASS
Outside every bedroom area PASS
Blower Door Test Certification PASS
Guard at deck, porches 36" or more PASS
Dryer Duct Max Length 35', Labeled Over
35' PASS
Every level, Every bedroom PASS
within 10' of all sleeping areas PASS
Bathroom / Kitchen Watertight complete up stairs bathroom PASS
Relief Valve ,Heat Trap/Water Temp 110
deg or less PASS
Fresh air supply 3' from grade PASS
Platform at all exterior doors PASS
Window guards req:<2' above floor/6'
above grade PASS
Deck Ledger-Bolted per Code PASS
4 inch Building Number Address visible
from road PASS
Foundation insulation to floor PASS
Plumbing fixtures complete work at upstairs bathroom PASS
Fresh Air Intake PASS
Emergency egress below grade walk out basement PASS
Mark Smith
Code Enforcement Officer