ChecklistReport002-20-24 091743 INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: RC-0458-2023 Case Module: Inspection Date: February 06, 2024 Inspection Status: Passed Inspector: Tyson Converse Inspection Type: Gas Insert Fireplace Job Address: , Parcel Number: Contact Type Company Name Name Contractor Cerrone Builders Inc Checklist Item Status Witness Operation On final PASS Dual Liner PASS CO Detection verify on final PASS Rigid Liner PASS Weather cap installed PASS Connected to flue: flue gases not mixing w/rm air PASS Manufacturer Hearth+Home Ser#LCG378185 PASS Gas Shut-off Valve PASS CSST Bonding PASS Model DV3732-B PASS Clearances to Combustibles (all sides) Verify mantel Height on Final. See page 53 of owners manual for spec's PASS Damper clip - permanently open PASS Installed per manual PASS Tank Placement (if LP) Natural Gas PASS Liner termination extends abv chimney PASS Tyson Converse Deputy Fire Marshal