Loading...
INSPECTION WORKSHEET INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: RC-0672-2023 Case Module: Permit Inspection Date: February 20, 2024 Inspection Status: Failed Inspector: John O'Brien Inspection Type: Residential Final Job Address: , Parcel Number: Contact Type Company Name Name Granted Permission Crown Field Services Contractor Crown Field Services Primary Owner U.S. Bank Trust N.A., Trustee N/A Checklist Item Status Building Inspector notes 2/20/24 The final inspection has failed for the following reasons. 1) The home has been winterized and there is no heat, electricity or water turned on. 2) The heat needs to be on in order to turn the water on. 3) The electricity needs to be on and a final inspection performed by a third party electrical inspector approved by the Town of Queensbury. Note: Please address these issues before scheduling a Final Inspection by the Town of Queensbury Building and Code Enforcement Department. FAIL 4 inch min building number address visible from road FAIL Chimney height, B vent, direct vent location FAIL Chimney rain cap installed FAIL Fresh air intake FAIL Fresh air supply 3 feet from grade FAIL 3 inch plumbing vent through roof, minimum 18 inches FAIL Outside spigots have air gap FAIL Roof complete Exterior finish complete Platform at all exterior doors PASS Handrail required with 4 or more risers FAIL Guards at stairs, decks and patios 30 inches or more above grade FAIL Guard at stairwell at 34 inches or more FAIL Guard at deck and porches 36" or more in height FAIL Handrail termination at newell post or wall FAIL Interior and exterior handrails 34" to 38" high FAIL 6 inch clearance to sill plate from grade PASS Gas meter and or regulator shut off 12 inches min above grade FAIL HVAC vent terminal 10 feet from lot line and openings FAIL Dryer duct max length 35 feet or per manufacturer's instructions FAIL Interior privacy doors and trim required PASS Exterior main entrance door min 36" wide PASS Bathroom and Kitchen floors must be watertight FAIL Low flow toilet 1.3 gallon per flushing cycle FAIL Safety glazing required within 5 feet of tub and shower FAIL Smoke detectors are min of 3 feet horizontally from opening of bathroom FAIL Smoke Detectors are required on every level and in every bedroom FAIL Smoke Detectors are required outside every bedroom area FAIL Smoke Detectors have battery back up FAIL Smoke detectors are interconnected FAIL Carbon monoxide detectors are within 10 ft of all sleeping areas FAIL Carbon monoxide detectors are required in bedrooms with gas appliances FAIL Carbon monoxide detectors are required on all levels with gas appliances (i.e. furnace) FAIL Bathroom fans required, if no window FAIL All plumbing fixtures complete FAIL Backflow preventors where required FAIL All Hot Water Systems R 3 on 3/4 inches or larger piping FAIL Duct work sealed properly FAIL Intake openings for HVAC FAIL Furnace shut off within 30 ft. or within line of site FAIL Furnace and hot water heater operating FAIL Pressure relief valve, heat trap, water temp 110 degrees or less FAIL Pressure relief valve down spout within 6 inches of floor FAIL Jack posts in basement lagged at top and bottom FAIL Fin elect; energy saving light bulbs 90 percent FAIL Arc fault breaker habitable spaces FAIL Flex gas pipe bonding FAIL Ok to issue temporary certificate of occupancy FAIL Ok to issue certificate of occupancy FAIL John O'Brien Director of Building & Codes