INSPECTION WORKSHEET
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0672-2023 Case Module: Permit
Inspection Date: February 20, 2024 Inspection Status: Failed
Inspector: John O'Brien Inspection Type: Residential Final
Job Address:
, Parcel Number:
Contact Type Company Name Name
Granted Permission Crown Field Services
Contractor Crown Field Services
Primary Owner U.S. Bank Trust N.A., Trustee
N/A
Checklist Item
Status
Building Inspector notes
2/20/24
The final inspection has failed for the following reasons.
1) The home has been winterized and there is no heat, electricity or water
turned on.
2) The heat needs to be on in order to turn the water on.
3) The electricity needs to be on and a final inspection performed by a
third party electrical inspector approved by the Town of Queensbury.
Note: Please address these issues before scheduling a Final Inspection
by the Town of Queensbury Building and Code Enforcement Department.
FAIL
4 inch min building number address
visible from road
FAIL
Chimney height, B vent, direct vent
location
FAIL
Chimney rain cap installed
FAIL
Fresh air intake
FAIL
Fresh air supply 3 feet from grade
FAIL
3 inch plumbing vent through roof,
minimum 18 inches FAIL
Outside spigots have air gap
FAIL
Roof complete
Exterior finish complete
Platform at all exterior doors
PASS
Handrail required with 4 or more risers
FAIL
Guards at stairs, decks and patios 30
inches or more above grade
FAIL
Guard at stairwell at 34 inches or more
FAIL
Guard at deck and porches 36" or more
in height
FAIL
Handrail termination at newell post or wall
FAIL
Interior and exterior handrails 34" to 38"
high
FAIL
6 inch clearance to sill plate from grade
PASS
Gas meter and or regulator shut off 12
inches min above grade
FAIL
HVAC vent terminal 10 feet from lot line
and openings
FAIL
Dryer duct max length 35 feet or per
manufacturer's instructions
FAIL
Interior privacy doors and trim required
PASS
Exterior main entrance door min 36" wide
PASS
Bathroom and Kitchen floors must be
watertight
FAIL
Low flow toilet 1.3 gallon per flushing
cycle
FAIL
Safety glazing required within 5 feet of
tub and shower
FAIL
Smoke detectors are min of 3 feet
horizontally from opening of bathroom
FAIL
Smoke Detectors are required on every
level and in every bedroom
FAIL
Smoke Detectors are required outside
every bedroom area
FAIL
Smoke Detectors have battery back up
FAIL
Smoke detectors are interconnected
FAIL
Carbon monoxide detectors are within 10
ft of all sleeping areas
FAIL
Carbon monoxide detectors are required
in bedrooms with gas appliances
FAIL
Carbon monoxide detectors are required
on all levels with gas appliances (i.e.
furnace)
FAIL
Bathroom fans required, if no window
FAIL
All plumbing fixtures complete
FAIL
Backflow preventors where required
FAIL
All Hot Water Systems R 3 on 3/4 inches
or larger piping
FAIL
Duct work sealed properly
FAIL
Intake openings for HVAC
FAIL
Furnace shut off within 30 ft. or within line
of site
FAIL
Furnace and hot water heater operating
FAIL
Pressure relief valve, heat trap, water
temp 110 degrees or less
FAIL
Pressure relief valve down spout within 6
inches of floor
FAIL
Jack posts in basement lagged at top and
bottom
FAIL
Fin elect; energy saving light bulbs 90
percent
FAIL
Arc fault breaker habitable spaces
FAIL
Flex gas pipe bonding
FAIL
Ok to issue temporary certificate of
occupancy
FAIL
Ok to issue certificate of occupancy
FAIL
John O'Brien
Director of Building & Codes