ChecklistReport002-05-24 092208
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0757-2023 Case Module: Application
Inspection Date: February 05, 2024 Inspection Status: Reinspect
Inspector: Mark Smith Inspection Type: Foundation
Job Address: 26 OTTER TRACK
, Parcel Number:
Contact Type Company Name Name
Granted Permission N/A
Primary Owner N/A
Contractor Michaels Group Homes, LLC
Engineer Northern Engineering Technologies PLLC
Granted Permission N/A
Primary Owner N/A
Checklist Item
Status
Permit card visible from road PASS
Building Inspector notes
2/5/24 partial approval for foundation - foundation damp proofing verified -
footing drains at exterior of foundation verified FAIL
Footings PASS
Piers PASS
Reinforcement in place PASS
Foundation wall pour with 2 rows #4 horizontally PASS
Foundation reinforcement in place PASS
Footing dowels or keyway in place PASS
Foundation dampproofing PASS
Footing drain to daylight or to sump pit PASS
Footing drain stone - 12 inch width PASS
Footing drain stone -- 6 inches above
footing PASS
Footing drain stone -- 6 mil poly with fabric PASS
Backfill approved PASS
Plumbing under slab FAIL
Pressure test FAIL
Air or head test FAIL
5 psi or 10 ft. above highest connection
for 15 minutes FAIL
PVC, Cast, Copper and Pex tubing FAIL
Foundation Insulation Interior or Exterior FAIL
Rough Grade 6 inch drop within 10 ft. FAIL
Poly under slab in wet areas FAIL
Mark Smith
Code Enforcement Officer