ChecklistReport002-02-24 092855
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0755-2023 Case Module: Permit
Inspection Date: February 02, 2024 Inspection Status: Reinspect
Inspector: Mark Smith Inspection Type: Rough Plumbing
Job Address:
, Parcel Number:
Contact Type Company Name Name
N/A
Granted Permission N/A
Primary Owner N/A
Checklist Item
Status
Permit card visible from road FAIL
Building Inspector notes
2/2/24 partial approval for rough plumbing. - plumbing for domestic water
supply approved. plumbing charged at time of inspection. FAIL
Rough plumbing, nail plates PASS
Plumbing vent, vents in place FAIL
3 inches vent through roof - 18 inches
minimum exposed FAIL
1 1/2 inch minimum drain size FAIL
Shower liner test with 2 inches of water FAIL
Washing machine drain, 2 inches
minimum PASS
Washing machine trap: 18 inches-42
inches discharge PASS
Cleanout every 100 feet change of
direction FAIL
Drain and venting PASS
Pressure test FAIL
Air or head test PASS
5 psi or 10 ft. above highest connection
for 15 minutes PASS
Water supply piping PASS
Water supply piping pressure test PASS
Water supply piping air or head test PASS
50 psi for 15 minutes FAIL
Air test gas piping 10 psi for 10 minutes FAIL
All return air duct work must be hard
piped FAIL
Duct insulation- if required in unheated
spaces FAIL
Duct Blaster Test for duct work, minimum
R-8, unheated spaces FAIL
Duct work sealed properly FAIL
Mark Smith
Code Enforcement Officer