ChecklistReport002-01-24 014200
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: CC-0746-2023 Case Module: Permit
Inspection Date: February 01, 2024 Inspection Status: Reinspect
Inspector: Mark Smith Inspection Type: Rough Plumbing
Job Address: 257 DIX AVE
, Parcel Number:
Contact Type Company Name Name
Granted Permission GARVEY SISTERS, LLC
Primary Owner GARVEY SISTERS, LLC
N/A
Architect N/A Ethan Hall
Checklist Item
Status
Permit card visible from road FAIL
Building Inspector notes
2/1/24 partial approval for rough plumbing - plumbing under slab for sanitary
drains and vents approved. - plumbing under slab for floor drains, oil
separator verified. plumbing tested with 5 psi air pressure. PASS
Rough plumbing, nail plates FAIL
Plumbing vent, vents in place FAIL
3 inches vent through roof - 18 inches
minimum exposed FAIL
1 1/2 inch minimum drain size FAIL
Shower liner test with 2 inches of water FAIL
Washing machine drain, 2 inches
minimum FAIL
Washing machine trap: 18 inches-42
inches discharge FAIL
Cleanout every 100 feet change of
direction FAIL
Drain and venting FAIL
Pressure test FAIL
Air or head test FAIL
5 psi or 10 ft. above highest connection
for 15 minutes FAIL
Water supply piping FAIL
Water supply piping pressure test FAIL
Water supply piping air or head test FAIL
50 psi for 15 minutes FAIL
Air test gas piping 10 psi for 10 minutes FAIL
All return air duct work must be hard
piped FAIL
Duct insulation- if required in unheated
spaces FAIL
Duct Blaster Test for duct work, minimum
R-8, unheated spaces FAIL
Duct work sealed properly FAIL
Mark Smith
Code Enforcement Officer