ChecklistReport001-31-24 011701
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: CC-0013-2023 Case Module: Permit
Inspection Date: January 31, 2024 Inspection Status: Reinspect
Inspector: Mark Smith Inspection Type: Framing
Job Address: 78 MAIN ST
, Parcel Number:
Contact Type Company Name Name
Architect N/A Ethan Hall
Granted Permission FOOTHILLS BUILDERS, LLC
Contractor FOOTHILLS BUILDERS, LLC
FOOTHILLS BUILDERS, LLC
Primary Owner 78-80 Main Street LLC
Checklist Item
Status
Permit card visible from road FAIL
Building Inspector notes
1/31/24 partial approval for framing -remaining sheer walls at third floor
corridors, nailing pattern verified. PASS
Framing FAIL
Ice and water shield 24 inches from wall FAIL
Less than 4:12 pitch install double layer
of ice and water shield FAIL
Attic Access 22 inch x 30 inch minimum
with 30 inch head clearance FAIL
Crawl space 18 inches x 24 inches
access, 1 sq. ft. per 150 sq. ft. vents FAIL
Jack Studs, headers and double jack
studs 6' or greater FAIL
Garage portal framing FAIL
Truss Specification Provided on site FAIL
Bracing and bridging FAIL
Hurricane Clips and Uplift Screws all nail
holes filled as per manufacturer FAIL
Jack Posts and Main Beams FAIL
Lag top plates and bottom plates of steel
columns FAIL
Exterior sheeting nailed properly FAIL
Notches, Holes and Bearing Walls FAIL
Headroom 6 ft. 8 in. FAIL
Deck post beam connections must use
hex head bolts FAIL
Joist hangers FAIL
Metal Strapping for Notches Top Plate FAIL
Mark Smith