Mixed Use Building 70-80 Main Street Queensbury NY sample 23082 max density determinationCONSTRUCTION TECHNOLOGY INSPECTION & TESTING DIVISION, P.D.& T.S., INC. 4 William Street, Ballston Lake, New York 12019 Phone: (518) 399-1848 Email: constructiontech@live.com CLIENT: FOOTHILLS BUILDERS REPORT DATE: 04/07/23 9 MOUNTAINSIDE DRIVE SAMPLE NUMBER: 23082 QUEENSBURY, NEW YORK 12804 OUR FILE NUMBER: 100.319 LAB TECHNICIAN: ROBERT BEHAN ATTN: MR. JOE LEUCI PROJECT: MIXED USE BUILDING: 70-80 MAIN STREET, QUEENSBURY, NEW YORK REPORT OF MOISTURE / DENSITY RELATION OF SOILS ::: PROCTOR MATERIAL SOURCE: ONSITE MATERIAL MATERIAL DESCRIPTION: SAND, fine/medium; trace Silt/Clay PROCTOR METHOD: ASTM D-1557: MODIFIED EFFORT GRADATION METHOD: ASTM D-1140 / D-422: WASHED MAXIMUM DENSITY 107.6 PCF OPTIMUM MOISTURE 14.2 % GRADATION SIEVE PERCENT SPECIFICATION SIZE PASSING ALLOWANCE 4" 3" 2 1/2" 2" 1 1/2" V 3/4" 1/2" 3/8" 1/4" #4 100.0 1/8" #8 99.8 #10 #16 98.5 #20 #30 93.4 #40 53.2 #50 15.8 #60 12.2 #80 #100 5.1 #140 #200 2.4 REPORT DISTRIBUTION: 1 2 3 4 5 113 112 111 H z 110 w 0 0 109 I- O O LL U 108 m n U w 107 a 0 =z 106 O a. 105 104 103 10 ZERO AIR VOIDS CURVE: 2.46 SPECIFIC GRAVITY 11 12 13 14 15 16 17 18 MOISTURE CONTENT::: PERCENT DRY WEIGHT GENERAL NOTES: Respectfully, CONSTRUCTION TECHNOLOGY )a4v' &.4. ROBERT BEHAN, (NICET) MANAGER TECHNICAL SERVICES