Loading...
1987-722 i w CERTIFICATE OF OCCUPANCY TOWN OF QUEENSSURY WARREN COUNTY, NEW YORK rr __ � February 13 19 90 This is to certify that work requested to be done as shown by Permit No. 87- 722 has been completed. Alterations to Retail. Store This structure may be occupied as a Location Northgate P3 aza Owner Northgate Enterprises Inc , By Order Town Board 70VV-N OF QUEENSOURY Building & Zoning Inspector BUILDING PERMIT TOWN OF QUEENSBURY No. 87-722 WARREN COUNTY, NEW YOR K o PERMISSION is hereby granted to Flan Mills Studio `orn I Plaza hate OWNER of property located at Nort g Street, Road or Ave, w in the Town of Queensbury, To Construct or place a Alterations to retail store at the above location in accordance to application together with plot plans and other information hereto filed and approved and in compliance with the Town of Queensbury Building and Zoning Ordinance_ 1 . OWNER'S Address is Northgate Plaza 728 Glen St . Queensbury , N . Y . t✓ 2. CONTRACTOR or BUI LDE R"S Name to to Michael Stouffer ii 3_ CONTRACTOR or BUILDER "s Address 0 4_ ARCHITECT'S Name O �-i rr 04 S. ARCHITECT'S Address p� rt m 'd W to 6. TYPE of Construction — {Please indicate 6y X} p� i i Wood Frame 1 y Masonry { 1 Steel { l 7. PLANS and Specifications No. 1178 sq . ft . per specifications and application . CD n 8. Proposed Use b Alterations to retail store c:o l ro rt $5 . 00 CIO r $ 15 . 00 PERMIT FEE PAID — THIS PERMIT EXPIRES May 1 , 19 88 cr5 (If a period longer is r rt g per squired an application far an extension must 4e made to the Building and Zoning inspector of the o town of Guaensbury before the expiration date.} rt fD Dated at the Town of Queensbury this 27th Day of October 19 87 SIGNED BY !� for the Town of Queensbury Building and Zoning Inspector A;OC--- TO BE COMPLETED BY BLDG . DEPT . a�] / Application No . wn ofeeerlbul't Permit Issued 19 "', � c t ' BUILDING and ZONING DEPARTMENT Permit Expires 19 _ OCTBay and Haailand Road, R. D. 1 Box 98 Zoning Designation C 191987 Queensbury, New York 12801 variance No . ✓ j Site Plan Review o , f ✓ Approved G e APPLICATION FOR � (/ FUILDING AND ZONING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION , ANSWER ALL OF THE FOLLOWING . The undersigned hereby applies for a Building Permit to do the following work which will be done in accordance with the description , plans and specifications submitted , and such special conditionsas may-be-indicated-on-the-Permit . ----- -�-- -------------------`--- The owner of this property is : Tel . P . O_ Address r7 Property Location : J:IQZ LL., —w "SZ- � / 2 o Tax Map Street number or building lot. number Subdivision name ( if applicable) THE PERSON RESPONSIBLE FOR SUPERVISION OF WORK AS REGARDS BUILDING CODES IS : Name P . O . Address Tel _ No . Name of builder �} p •asy �r { 5'?'t �c•£9�f Address_ . %mac f G �� .J ' Tel .�-i � 7 Name of plumber Address Tel . Name of mason Address Tel . NATURE OF PROPOSED WORK : ZONING INFORMATION : _Construction of a new building A PLOT PLAN MUSS.' BE PREPARED AND SUBMITTED , _Addition to a building * drawn reasonably to scale and attached hereto , Alteration to a building showing clearly and distinctly all buildings , (no change to exterior dimensions } " whether existing or propose ndicate all Other work (describe) set-back dimensionT/docat! m plines . Give street and number f nd indicate whether interiornerow location FOR DEMOLITION PERMIT , STATE SIZE AND * of water supply on(figuration LOCATION OF STRUCTURES AFFECTEDw of septic dispo a . COMPLETE INFO TN Q RED BELOW _ size of prop ty ft X ft . Existing bu ' Ading ( s) Size £t t . PROPOSED BUILDING AND USE : " Existing building ( s ) se Size of new structure ft K ft a Foundation-pier/ slab/crawl/partial/full * Proposed building , distance from property line (circle one ) Front yard ft Rear yard ft Now of stories (habitable space) * Side yards ft and ft Height ( grade to ridge ) ft . If on corner , setback from side street ft If residential , no . of ili s Now of roomsfexcluding a hs OCCUPANCY INFORMATION No . of bedrooms _ PRIMARY BUILDING - No . of bathrooms One family dwelling Primary heating syst m � Two family dwelling Type of fuel Multiple dwelling / Number of units No , of fireplaces to be installed Permanent occupancy Will a wood stove be installed? � Transient occupancy Central Air conditioning? Business BUILDING STYLE, PRIMARY STRUCTURE Industrial Other Ranch Contemporary Log cabin If addition , what will use be? Raised ranch Mansion Duplex Split level Old style Bungalow Cape Cod Cottage Other ACCESSORY BUILDING- F Colonial Row Town House * Detached garage e r tw c / car ( CIRCLE ONE PLEASE ) Attached garage a ca / tw r/ car _Private storage uildi g ESTIMATED MARKET VALUE OF Other CONSTRUCTION �,,�}} 6W v INFORMATION ON BUILDING SPECIFICATIONSe ON REVERSE SIDE OF THIS SHEET , TO BE COMPLETED ? Form BPA 4/86 and-vl �IV/owl BUILDING PERMIT APPLICATION CONTINUED - BUILDING SPECIFICATIONS : VAlt Type of construction , wood frame , fire safe , etc . 076"A- iC._. will any second-hand or ungraded lumber be used? If so , for what ? Foundation wall material Thickness Depth of foundation below grade (to bottom of footing ) Will there be a cellar?_ Heated or unheated? Floor sq. footage sq ft Will there be a basement? Will any portion be used as living space ? ( If so , what portion? sq, ft . - - Type of use? Type of roof - sloped/flat/shed/other Material of roof Size , wood studs "X '" spacing "o . c . length ft , Joists ( floor beams ) 1st . floor it " spacing "o . c . span ft . Joists ( floor beams ) 2nd , floor "X '" spacing "o . c . span ft . Overlays ( ceiling beams ) '"x " spacing "o . c . span ft . Roof rafters ""3€ '" spacing o . c . span ft . / Roof trusses [pre-enginee f ) 0(f spacing "' o . c . span ft _ s ' / Awy Exterior wall finish 4. c6�_.__-._._of what material c� f4C' �"�j Interior wall finish if a garage is to be attached , describe materials to be used for FIRE SEPARATION : Is there to be an opening between garage and dwelling? If so will a Fire-rated door , enclosure , and self-closing device be provided? Will a flue-lined chimney be installed? Height above roof ft . Depth of chimney foundation below grade ft , Depth of fireplace hearth ft , in . Water supply - Municipal or private well SEPTIC SYSTEM _ Distance from ANY private well ( including adjoining properties ft , (A separate application is necessary for any repair or new installation of septic system) Town of Queensbury County of Warren A F F I D A V I T STATE OF NEW YORK I swear that to the best of my knowledge and belief the statements contained in this application , together with the plans and specifications submitted , are a true and complete statement of all proposed work to be done , on the described premises and that all provisions of the BUILDING CODE , THE ZONING ORDINANCE , and all other laws pertaining to the proposed work shall be complied with , whether specified or not , and that such work is authorized by the owner . SWORN TO BEFORE ME THIS Signature_ ____ __ ---------- ------ er , owner ' s agent , zrect , contractor day of 19 Notary Public , Warren County , N . Y . SPECIAL CONDITIONS OF THE PERMIT : lell / ,/ elT By------------------------------ C�'] �upen3bur Q � Mown Of 1019 D4NG and ZGHf{VG OeeAkATM 98 puf� F.D. i B �J ; �� gay and Eiavilar►d Road, QueensbUrY• 'New York 12801 NG INSPPC-VOP I S REPORT T,y ME ---�'"-!� /� Permit t Dae / PsPP'RQVED - YES N4 Foot ingfk'ier Fc3rms Foun da Y_io n Waterproofing ��„c}cfili Framing " Roof ing 531 ing thasonry Veneer ___--- Baugh Plumbing._- _� --- Relief Valves______-_- Ext . Porches ;xn fished Floors Interior 'Trim Stairs & Railings r Dr �- ain Tile Cella -.---- ._.--- Concrete Floors�� p3-bg . Fixtures Gar - Fireproofing ,Door Closers 5mcke Detectors Chimney IN SU I,AT 10N Fours mat�-o'n Floors Walls, Ceiling 1N5PECT10", F It4 NL FLECTRICFs _- llR1VEWAy Al'pROV L � Final Building, �aurYey inepection (call Next scheduled when ready ) / 40 ` Remarks- /) _ _ Aa C r 17 Builc3in i 6/86 and-vl "�� �ueens � ury BUILDING and ZONING DE PAR Box 9$ Say and Haviland Road, R.C3- ,Queensbury, New+ York 12801 BUILDING ImSPECTOR ' S� RREPOR.Ti NAME LOCATION Date permit Now APpRC]V ET7 - YES NO FootIng/pier Forma Foundation Waterproofing Ba xfill naming Roofing Si ding Masonry Veneer _��--- Riough p1 ing Relief Valves � .-- Ext . porches Finished Floors Interior 'Trim Stairs & galling Cellar Drain Tile Concrete Floors plbg , Fixtures Gar . Firep roo€ i g -�--~ Door Closers s smoke Detecto �-- ChimneY IN SU LAT I ONI Foun dat i.on Floors Walls Ceiling `~~ F IN AL ELEC`PRICAI I1�1 SpECTI DR-IVEWAY APPROVAL Srvey� Final Building Next sc'hed'�`led Insp ection (call when ready) Remarks- Building Inspector 6/B�' >Yyc3-vl TOWN OF Q UEENSBURY BUILDING AND CODES DEPARTMENT BAY & HAVILAND ROADS I280 QUEENSBURY, NEW TELEPHONE ( 518 ) 792-5832 BUILD-ING INSPECTOR' S REPORT REQUEST FOR l}N�S,rPEC�T..CaN 'RXY'E� NAME LOCATION _ 7 ? 7 ^ 1 PERMIT # DATE ,APPROVED YES NO FOOTING/PIERS MONOLITHIC POZJR FORMS FOUNDATION/DAMPJPROOFING BACKFILL APPROVAL ROUGH PLUMBING FRAMING - ELECTRICAL ROUGH-IN INSULATION : l FOUNDATION FLOORS WALLS " ����1�CEILING C_F NAL INSPECTION CHIMNEY HEIGHT $, ROOFING SIDING EXTERNAL PORCHES/STEP$ ST,AIRS- CLEARANCE & IE VALVE PLUMBING FIXTURFSIRAL INTERIOR T14RXM PRIV*tCy DOORS IV FINISHED FLOORS GARAGE FIREPROOFING DOOR CLOSER (S) t SMOKE DETECTORS TON FINAL ELECTRICAL IN ONST,RUCTION FINAL APPROVAL A SIGNED CERT'IPICATE OF OCCUPANCY MUST BE T3TAX14 D FROM ES ARE UILDING D ED +•EPARTMENT BEFORE OCCUPI R,EMA R KS INSPECTOR TOWN OF QUEENSBURY BUILDING AND CODES DEPARTMENT BAY & HAVILAND ROADS QUEENSBURY, NEW YORK I280k TELEPHONE (5I8 ) 792- 58.32 BUILDING INSPECTOR' S REPORT REQUEST FOR INSPECTION RECEIVED NAME _ /`/- IS. 3 ' 3'?JL2 LOCATION DATPERMIT APPROVED YE NO FOOTING/PIERS MONOLITHIC' POUR FORMS FOUNDATIONIDAMP-PROOFING BACKFILL APPROVAL ROUGH PLUMBING FRAMING ELECTRICAL ROUGH-IN INSULATION: FOUNDATION F . FLOORS WALLS CEILING FINAL INSPECTION: CHIMNEY HEIGHT ROOFING ,SIDING EXTERNAL PORCHESI EPS� -�- STAIRS-CLEARANCE v RAILS PLUMBING FIXTUREOIRELIEF VALVE INTERIOR TRIM/PyIVACY ZOORS FINISHED FLOOR GARAGE FIREPR FING DOOR CLOSERS SMOKE DETEC S FINAL ELECTRIC L INSPECTION FINAL ApPROVA OF CONSTRUCTION A SIGNED CER FICATE OF OCCUPAiYVCY MUST BE OBTAINED FRO THE BUILDING D�EPApTMENT BEFORE THESE PREMISES ARE OCCUPIED'REMARxS: I „t [ & f tAA " I f/ I f D. III INSPE TOR BUILDING DEPT. COPY OF APPLICATION FORM "-EL, NEW YORK BOARD OF FIRE UNDERWRITERS, FILE THIS COPY WITH BUILDING DEPT. WHEN REQUIRED, TEMP. A DATE ' CITY OR r• VILLAGE TOMYNSFIIP �^% / -: ,.. '' STREET . ow No � .� i - f /COUNTY ROAD AND POLE NO. f -'` BETWEEN WHAT TWO POLE NO, CROSS TREETS IS ? OCCUPANT'S TION BLOCK -' LOT BUILDING !C.a OCCUPANCY / • ' OWNER'S NAME ANO ADDRESS TEL. il# SUPPLIED f ' ,r .+'r ], FROM THEIR OFFICE BUILDING IS MEW Q OLD CJ WORK {�'7 DEFECTS iS NEW ❑ ADDITIONAL RENKIVE6 ❑ LIST 13ELOW ALL EQUIPMENT WHICH YOU INSTALLED na NU No. of Flxtu B MBER OF OUTLETS Lanlp Reaaptaalas. M oTORS HEATERS CIRCUITS OFFICE USE tiot Slid* rVft ONLY df Atsb't alli..a Wa6 Reaep bswkbch M1ndant Brrlket No, T.. Emit No a ft� Deem INSPECTION Chat• aide Sara- bra Ba all- tat FR. 2nd FR. 7lyd FI. REMARKS: LIST OTHER ELECTRICAL DEVICES NOT SET FORTH ABOVE: 00 NOT USE THIS SPACE, This mpplicatjw is intended IO cover the abnae-fisted aqu ipnant to be inspected but it at taste of i Yell are autbo"zod tO smite the 1 there f4utd additietal aquipr eslt tpt abeaa listed, nspettion alws adjust tM fee W cwar- tlsa additiarllal egpnparaant, so Prtleidieel by tlr applicatt. 512E OF E L ECTR IC SIGN MAINS FEEDERS TOTAL LAMPS WATTS CHARACTER EXPOSED GAS TUBE SIGN OF WORK CONCEALED TRANSFORMERS OF VA WORK TO BE INUMSER) STARTED COMPLETED $12f OF SIGN ICAPACITYI SERVICE OVERHEAD UNDERGROUND ENTERS MAKER IL ING OF SIGN INSPECTION REQUESTED ON OR AS NEAR AS P40KMBLE NEW OLD O "DID DELAY BY GIVING FULL AND ACCURATE INF¢RMATiON. ALL SPACES { MUST BE FILLED IN OR APPLICATION MAY BE RETURNED- DATE OF ..i` PRINT NAMFe AWD ADO SS ' - - APPLICATIO NAME OF / -. '- r'F r 1/ SIGNATURE APPLICANT ' .. "' "' '�� ' /\ OF APPLICANT STREET ADWiESS ,i �_ - HONE # - POST OFITY OR F :: fin • - Or f � T -- � xICODE t ' LICENSE ND. WHEN APPLMCABLE AS EL (REV. 1/86) A SEPARATE APPLICATION UST BE FILED R EACH SEPARATE BUILDING v1cRrrIEx0 w n L L C O V E A N G 5 -�� 'llYllllllr� DESIGNERS, MANUFACTURERS and DISTRIBUTORS aF QUALITY WALLCOVERINGS, FABRICS and ACOUSTICAL SYSTEMS T December 12 , 1986 Olan Mills P . O . Box 23456 Chattanooga , TN 37422 PROJECT : ALL OLAN MILLS STUDIOS Per your request , this letter is to certify that VICRTEX vinyl Wall Covering pattern ( s ) BOSA NOVA-ALAMO meets the Federal Specifications CCC -W- 408A& B with Fire Hazard Classification as tested under ASTM- E84 and has earned a Class " A " Fire Rating . The Underwriters Laboratories Fire Hazard Classification for the above pattern ( s ) is as follows : FLAME SPREAD 15 FUEL CONTRIBUTED 0 SMOKE DEVELOPED 20 If we can be of further assistance , please advise . Sincerely , VICRTEX William Rauch Divisional vice President /ll cc : Steve Braden VICRTEX Sales Representative VICRTEX - A DIVISION OF L.E. CARPENTER AND COMPANY 1144 LOGAN CIRCLE, N .W., ATLANTA, GA 30318-2886 • TEL! (404) 351 .8220 .'ff. At^ , +. RRI T /\AIL. L- E3 POST OFFICE BOX SW • CHATSWORTH, GEORGIA 30705 May 16 , 1986 Olan Mills P . Q . Box 23456 Chattanooga , Tenn . 37422 Attn : Judy Noorbergen The Galaxy style listed below has been tested in the Flooring Radiant Panel Test . The test results exceed an average of 0 . 45 watts per square centimeter . 673 Versatility This style meets or exceeds Flooring Radiant Panel 'Pest ( NBS IR 75- 954 ) limits recommended by the Rational Bureau of Standards for exitways and corridors in institutional health occupancies ( hospitals , nursing homes ) . Please let us know if we can be of further assistance . Sincerely ,, " Lou Childers Technical Services Manager LCckd f i HOME OFFICE • 850 ARTHUR AVE. ELK GROVE VILLAGE. ILLINOIS 60007 • TELEPHONE (312) 593-0555 MILL r INDUSTRIAL BLVD. w CHATSWORTH. GEORGIA 30705 • TELEPHONE (404) 695-961 1 l ti noutL *� w . -�� car d if April 2 , 1986 clan Mills P . O . Box 23456 Chattanooga , Tenn . 37422 TO WHOM IT INLAY CONCERN The carpet style listed below complies with IiuD, FIIA standards and has been certified bar Associated Laboratories , lnc . , an approved _ LL- approved administrator in accordance with provisions of Bulletin UM- 44c . STYLE NUMBER : 673 STYLE NAME : `JERSATI1,1TY/ CELEBRITY TYPE : I I B SA XONY CLASS : 1 - MODERATE Tr.AFFIC FIBER : 1 00 o CFTI SECONDARY BACE I NG : ACTION Bt'?C This carpet will be listed in the ALI Certified Products Directory and will have the code designation 05244 . Sincerely , Brad Britton Technical Services r-janager BB ; rb A DIVISION OF GALAXY CARPET MILLS, INC_ HOME OFFICE • 850 ARTHUR AVE, + ELK GROVE VILLAGE, ILLINOIS 60007 TELEPHONE (312) 593-0555 MILL • mcrosTRIAL RI VD, 0 rHAT�WnRTH . +C;EORGIA ln7n9 0 TELFP"ONF f404) 695-9611 T4Wj I IL j April 2 , 1986 Olan Mills P . O . Box 23456 Chattanooga ., Tenn . 37422 Attn : Mr . Bill Taylor Listed below are manufacturing specifications for our style Versatility ,/ Celebrity . Pile Filler : 101 ) Nylon Pile tp.eiqht : 2 ") . 5 uzs . Pile 111eight : 1W34" " Gauge 3 / 16 " Stitchos Per 3 " : 28 11rimary U'(-ir1Jnfj * U - P - Secondary Ij) l- . A . i� Please let us knov) if we can 1)(% of iu )- ther ass i stance . Sincerely , Brad Britton Technical Services I' lana (Ijer / rb A DIVISION OF GALAXY CAnPET NULLS, INC. HOME OFFICE • 850 ARTHUR AVE. * ELK GROVE VILLAGE. ILLINOIS 60007 • TELEPHONE (312) 593-0555 MILL • INDO %TnIAL si. vn Trt t- 4 r-N P P I r) I s v y ar �r OF ATLAIAYA IRC. ` 3480 C- 1 OAKCLI17F ROAD n rLArv '1' n cyi Uttc: in 30340 "I' I; 1_ 1, tPIIONV 458-90 .14 ( 4041 February 24 , 1984 Citati.cAl CarpoUI P. O. 13ax 3909 Dalton , GA 30721 Attention : .Mr. ,Woe Withrc-n4 . Dean: Mr. Withrow : Izeference : Certification of 71267 L3E!M{.SLIIR --24 1dc3 have la).X).ratcary test results showing t1lat your BERISIIS_RL-24 li s physical �harac, t f:'ristics which meet and/or exceed the requireivents of LJ M44c . 1. are 1s::claPys, therefore , to certify this c�ualil y and will I�uhlish the following SLxla ill our July 1984 Directory of Certified CarLx PlzmLl No. 735; Quality No. 71267 ; I3T'RKSII1RE---24 ; Type III , Class l ; Olefin fAer; a-!a�l Loop texture; 0 . 15 inch pile heigl-1t ; 24 . 0 ounces pilo weight; 5760 pile density; and, 1.38 , 240 pile weight/densi.ty . Sedona Colors approved : Birch N:Lghtwatch Tangle charcoal Prairie Brown Walnut Graphic Red Rust 'Wnut oc3 Moorland Sable Wineroot The dies needed to back mark this quality have been furnished to you . Subscribed and sworn to before me wool thi of �' 19 e r / 9 ants very truly , Awe d? Notary _Public Notary Public, G2c�r�ia, State at Park J .W. McCarty , L' . E . tuSY (.61nft7l$Sigf1 Expires January 26, isaa Fc3ininistratcar MLA. CALF 30-r CEFffIFICA`I'lON I'F 1GI2AM 1 JTr 3/r>~V 1',eslirrr 1,6 tor'sra Ito rw.s N ..r.iclnrr it Vr) iriru•rr : . t :r>nI o oil.r,' 1 low 7 rr the re!1ral . ;rl r>,ir•n . . . . . . - . . 1 did Report Number 28957 Page 4 of 5 y the results are computed to the nearest number divisible by five . The data for flame spread and smoke developed are shown as solid computer print-out at the end of the reporte lines an the Tektronix 4051 TABLE I - DESCRIPTION OF MATERIAL TESTED Material Identification - Berkshire 24 Test Number - 1369-6333 (R) ' Date Tested December 14 , 1983 Construction - Tufted Loop Pile Pile Yarn Type - Olefin Weight - Total , 79 . 2 ounces /yard Secondary Backing - Woven Synthetic Color - 8587 Brown Sugar TABLE II - TEST RESULTS Flame Spread Smoke Developed Test Index index Specimen 0 0 mineral-fiber /cement board 100 100 red oak. flooring 30 130 i Berkshire 24 Although not a requirement of ASTM E 84--81a , Fuel Contributed , as calculated in accordance with ASTM E 84-75 , is 15 for the material tested . TABLE III - OBSERVATIONS DURING TESTING Ignition over the burners was noted at 0 . 82 minutes . The flame front advanced to 9 . 0 feet at 7 . 40 minutes with a maximum temperature recorded during the test of 647QF . dj drdddd d Id } �, __ dr r _ , ,_dddd � Y f "rr i `-0" € ; CAM do „r 4: Report Number 28955 Test Number 1360-5925 (R) Page 4 of 5 VI , TEST RESULTS The test data for the three specimens tested are shown in the chart below and in the Tektronix 4051 computer print-out on Page 5 . ,7' Material Identification - Berkshire 24 Test Number - 1360- 5925 (R) Date Tested - November 28 , 1983 Specimen Number 1 2 3 ' Distance Maximum Burn (cm) 49 . 6 53 . 4 48 * 6 Time to Flame-out (minutes ) 58 . 4 87 . 7 62 . 1 Critical Radiant Flux (W/ cm2 ) 0 . 35 0 . 31 0 . 37 . .F AVERAGE CRITICAL RADIANT FLUX 0 . 34 Watts / centimeterZ RADIANT The Standard Deviation } of the three values of the measured ( 5 critical radiant flux is 0 . 608 watts per square centimeter when calculated in accordance with the American Societyr for Testing and Materials Manual on Quality Control , STP 15c . Id ;k �s :i ' —.^._ W ef" • • r— -t -. ., f"' . �.l ^ R"?xTlik# 4 ± C4f .fiia� n+ �:1 ' ' " ' " "