INSPECTION WORKSHEET 03012024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0309-2021 Case Module:
Inspection Date: March 01, 2024 Inspection Status: Passed
Inspector: Mark Smith Inspection Type: Residential Final
Job Address: 23 KNOLLS RD NORTH
, Parcel Number:
Contact Type Company Name Name
Owner N/A Thomas Ormsby
Checklist Item
Status
5/8" Type X with Living Space Above
PASS
Emergency egress below grade
walk out basement
PASS
Heat detector in garage
PASS
Gas Shut-off Exposed & Regulator 12"
min abv grd
PASS
Fresh Air Intake
PASS
All Hot Water Systems: 3/4" or larger
piping R-3
PASS
As Built Septic System
PASS
Battery backup
PASS
Roof Complete / Exterior Finish Complete
PASS
Furnace shut-off w/in 30 ft. or w/in line of
site
PASS
Not less than 3' horiz from opening of
bthrn
PASS
Guard at stairwell at 34" or more
PASS
Jack posts in basement lagged at top and
bottom
PASS
3" Plumbing Vent through roof minimum
18 inch
PASS
CSST/other piping in conduit if buried,if
required
PASS
OK to Issue Temporary C/O
PASS
Outside Spigots have Air Gap
PASS
Relief Valve ,Heat Trap/Water Temp 110
deg or less
PASS
1/2" Gypsum or House Wall and Gable
PASS
Handrail 4 or more risers
PASS
Gas Log In Sealed or Glass Enclosure
PASS
Inter Connected
PASS
within 10' of all sleeping areas
PASS
Fresh air supply 3' from grade
PASS
Plumbing fixtures
complete work in master bathroom
PASS
4 inch Building Number Address visible
from road
PASS
Fin Elect; Energy Saving Light Bulbs 90
Percent
PASS
Duct work sealed properly
PASS
Smoke Detectors:
PASS
Outside every bedroom area
PASS
Window guards req:<2' above floor/6'
above grade
PASS
Guards at stairs,decks,patios 30" + above
grade
PASS
Attic Access 22 x 30 minimum
PASS
Attic Access Gasketed
PASS
Bathroom / Kitchen Watertight
complete doors and trim at interior
PASS
Grade away from foundation: 6" down,
10' out
PASS
Interior privacy/trim/doors/main entrance
36
PASS
Arc Fault Breaker Habitable Spaces
PASS
Carbon Monoxide Detectors:
PASS
6" clearance to sill plate
PASS
HVAC Vent Terminal 10' from Lot Line &
Openings
PASS
Foundation insulation to floor
PASS
Chimney Height / B Vent / Direct Vent
Location
PASS
CO in bedrooms w/gas appliances
PASS
Seals on Garage Doors, esp. Wood
PASS
Low flow toilet 1.3 gal/flushing cycle
PASS
Blower Door Test Certification
PASS
20 Minute Fire Door/Self-Closing
Hardware
PASS
Platform at all exterior doors
PASS
on all levels w/gas appliances (i.e.
furnace)
PASS
Dryer Duct Max Length 35', Labeled Over
35'
PASS
Flex Gas Pipe Bonding
PASS
Furnace/Hot Water Heater operating
PASS
Basement stairs closed rise greater than
4 inches
PASS
Attic Access Insulation = Attic R- Value
PASS
Every level, Every bedroom
PASS
OK to Issue C/O
PASS
Propane Tank: Proper Setback from Prop
Line/Struct
PASS
Bathroom Fans, if no window
PASS
Handrail Termination at Newell Post or
Wall
PASS
Basement wall insulation R- value verified
PASS
Guard at deck, porches 36" or more
PASS
Final Survey Plot Plan
submit final survey
PASS
General Comments
11/13/23 partial approval for final residential inspection. Approved for
temporary Certificate of Occupancy only. Complete the items listed below
for final approval.
-Complete siding and exterior trim.
- install permanent stairs at interior garage entry.
-complete work at master bathroom.
-Submit blower door test results.
-Submit final survey.
-Install permanent counter tops in kitchen.
- Final inspection for gas fire place.
- Final inspection by Code Compliance Officer Bruce Frank will be
required.
2/22/24 final inspection for single family dwelling not approved.
items remaining
- blower door test results
- submit final survey.
3/1/24 final inspection for signal family dwelling approved.
- items listed above have been received.
PASSN/O
Mark Smith
Code Enforcement Officer