INSPECTION WORKSHEET 03012024 INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: CC-0428-2022 Case Module: Permit Inspection Date: March 01, 2024 Inspection Status: Reinspect Inspector: Mark Smith Inspection Type: Commercial Final Job Address: 1066 State Route 9 , Parcel Number: 296.9-1-10.12 Contact Type Company Name Name Owner Furniture House North LLC Architect Rucinski Hall Architecture Checklist Item Status Building Inspector notes 2/21/24 final commercial inspection not approved, please address the items listed below and call for recheck when completed -provide as built drawings and letter of substantial completion from design engineer -provide proof of HVAC air balancing -provide proof of final electrical inspection -provide handicapped signage at upstairs and ground level rest rooms, install H.C. mirrors at restrooms as discussed on site -cover open spaces in electrical box a front gable closet -complete sheet rock in closet under stairs -complete plumbing for water supply in kitchen. -install ADA counter at front bar area as discussed on site. -install handicapped parking spaces and signage as discussed on site. 2/29/24 final commercial inspection not approved. - provide proof of final electrical inspection. - provide air balancing report. - complete plumbing work in kitchen and mechanical room under stairs. call for recheck when ready 3/1/24 partial approval for final commercial inspection, approved for temporary certificate of occupancy only. complete the items listed below and call for recheck - submit air balancing report - complete plumbing for domestic water supply in the kitchen. - final approval from Zoning Department will be required be C.O. can be issued - install handicapped service counter as discussed on site PASSN/O Chimney and B vent, direct vent location 3 inches vent stack through roof - 18 inches minimum exposed PASS Roof complete PASS Exterior finish of building PASS Grade Complete, 6 in 10ft or Equivalent PASS Interior and exterior guardrails 42 inches platforms and decks PASS Interior and exterior balusters 4 inch max spacing platform and decks PASS Stair rail 34 inches–38 inches high on both sides of stairway, 12 inches beyond top and bottom of stairs PASS Step risers 7 inches max and treads 11 inches minimum PASS Doors 36 inches with Lever Handle and or Panic Hardware, if required PASS Exits At Grade Or Platform 36 inches (w) x 44 inches (l) PASS Gas Shut-off Exposed and Regulator 12 inches min above grade PASS Floor Bathroom Watertight Other Floors Okay PASS Pressure relief valve, heat trap and water temp 110 deg or less PASS Pressure relief valve down spout within 6 inches of floor PASS Outside spigots have air gap PASS Gas furnace shut off PASS HVAC vent terminal 10 feet from lot line and openings PASS Attic Access 30 inches x 20 inches x 30 inches (h) PASS Attic access gasketed PASS Attic access insulation R-value must equal ceiling R- value PASS Elevator shaft sealed PASS HC toilet flush handle on open side of water closet PASS HC side and rear grab bars 36 inches above floor PASS HC grab bar: 42 inches side, 12 inches from corner PASS HC vertical grab bar 18 inches minimum high PASS HC vertical grab bar 39 inches from floor and corner PASS HC rear grab bar 36 inches with 24 inches to open side PASS HC mirrors 40 inches above floor to bottom of glass PASS HC sinks 34 inches above floor PASS Low flow toilet 1.3 gallons per flushing cycle PASS HC bathroom signage PASS HC parking lot signage PASS HC parking striping PASS Universal symbol of access displayed PASS Public toilet room handicapped accessible PASS Handicapped service counters 34 inches max from floor FAIL Final electrical and flex gas piping bonded PASS Building number or tenant address on building or drive PASS Bldg Access All Sides 20ft Drivable Surface PASS Engineer or architect approval PASS Electronic as builts PASS HVAC air balancing report FAIL Ok to issue temporary certificate of occupancy 3/1/24 approved for temporary c.o. only PASS Ok to issue certificate of occupancy Mark Smith Code Enforcement Officer