INSPECTION WORKSHEET 02232024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0108-2022 Case Module: Permit
Inspection Date: February 23, 2024 Inspection Status: Reinspect
Inspector: Charles Dyer Inspection Type: Residential Final
Job Address: 211 ASSEMBLY POINT RD
, Parcel Number:
Contact Type Company Name Name
Owner N/A
Owner N/A
Contractor Larmon House Movers Inc
Architect AJA Architecture & Planning
Checklist Item
Status
Building Inspector notes
provide kitchen sink / provide temporary guard at deck / provide final
electrical / provide garage doors / provide bedroom doors with hardware
PASS
4 inch min building number address
visible from road
Chimney height, B vent, direct vent
location
PASS
Chimney rain cap installed
PASS
Fresh air intake
PASS
Fresh air supply 3 feet from grade
PASS
3 inch plumbing vent through roof,
minimum 18 inches
PASS
Outside spigots have air gap
PASS
Roof complete
PASS
Exterior finish complete
FAIL
Platform at all exterior doors
PASS
Handrail required with 4 or more risers
Guards at stairs, decks and patios 30
inches or more above grade
FAIL
Guard at stairwell at 34 inches or more
FAIL
Window guards req at less than 2' above
floor and 6' above grade
PASS
Guard at deck and porches 36" or more
in height
FAIL
Handrail termination at newell post or wall
FAIL
Interior and exterior handrails 34" to 38"
high
FAIL
Wood deck 2 feet or more from grade
diagonal bracing required
provide diagonal bracing at 6x6 posts
FAILN/O
4 or more Deck Joist Ledger Connections
starting 24" from each end
PASS
Deck ledgers to be bolted per code
PASS
Grade away from foundation sloping 6
inches in the first 10 feet
FAIL
6 inch clearance to sill plate from grade
PASS
Gas meter and or regulator shut off 12
inches min above grade
propane
N/O
HVAC vent terminal 10 feet from lot line
and openings
PASS
Dryer duct max length 35 feet or per
manufacturer's instructions
PASS
Interior privacy doors and trim required
provide doors and hardware
FAIL
Exterior main entrance door min 36" wide
PASS
Bathroom and Kitchen floors must be
watertight
complete 2nd bath
N/O
Low flow toilet 1.3 gallon per flushing
cycle
at completed bath
FAIL
Smoke detectors are min of 3 feet
horizontally from opening of bathroom
PASS
Smoke Detectors are required on every
level and in every bedroom
PASS
Smoke Detectors are required outside
every bedroom area
PASS
Smoke Detectors have battery back up
PASS
Smoke detectors are interconnected
PASS
Carbon monoxide detectors are within 10
ft of all sleeping areas
PASS
Carbon monoxide detectors are required
on all levels with gas appliances (i.e.
furnace)
PASS
Heat detector required in attached garage
PASS
Attic access 22 inches x 30 inches
minimum with 30 inch high clearance
PASS
Attic access insulation R-value must
equal ceiling R- value
PASS
Attic access gasketed
PASS
Crawl space and knee wall access
insulated and gasketed
PASS
Bathroom fans required, if no window
PASS
All plumbing fixtures complete
FAIL
Backflow preventors where required
PASS
Foundation insulation to basement floor
PASS
All Hot Water Systems R 3 on 3/4 inches
or larger piping
PASS
Duct work sealed properly
PASS
Intake openings for HVAC
PASS
Furnace shut off within 30 ft. or within line
of site
PASS
Propane tank proper setback from
property line or structure
PASS
Furnace and hot water heater operating
PASS
Pressure relief valve, heat trap, water
temp 110 degrees or less
PASS
Pressure relief valve down spout within 6
inches of floor
PASS
1/2 inch Gypsum or House Wall and
Gable
PASS
5/8 inch Type X with living space above
PASS
20 minute fire door and self-closing
hardware
PASS
Seals on garage doors, esp. wood
provide garage doors
N/O
Basement wall insulation R- value verified
PASS
Basement egress: 5 s.f. window w/sill or
Bilco door
PASS
Jack posts in basement lagged at top and
bottom
PASS
Garage floor pitched
PASS
Gas log in sealed or glass enclosure
PASS
Fin elect; energy saving light bulbs 90
percent
FAIL
Final survey plot plan
provide final survey
FAILN/O
Arc fault breaker habitable spaces
PASS
Flex gas pipe bonding
PASS
As built septic system
PASS
Site plan or variance approval inspection
FAIL
Fuel Tanks above flood plain elevation
PASS
Ok to issue temporary certificate of
occupancy
FAIL
Ok to issue certificate of occupancy
FAIL
Charles Dyer
Code Enforcement Officer