Loading...
ChecklistReport002-01-24 021740 INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: RC-0715-2023 Case Module: Permit Inspection Date: February 01, 2024 Inspection Status: Passed Inspector: Charles Dyer Inspection Type: Residential Final Job Address: 9 RIDGEWOOD CT , Parcel Number: Contact Type Company Name Name N/A Contractor PATTEN PROPERTY DEVELOPMENT, LLC Granted Permission PATTEN PROPERTY DEVELOPMENT, LLC Primary Owner N/A Primary Owner N/A Checklist Item Status Building Inspector notes for partial alteration of basement/full bath and sleeping area. PASS 4 inch min building number address visible from road PASS Chimney height, B vent, direct vent location FAIL Chimney rain cap installed FAIL Fresh air intake PASS Fresh air supply 3 feet from grade PASS 3 inch plumbing vent through roof, minimum 18 inches PASS Outside spigots have air gap PASS Roof complete PASS Exterior finish complete PASS Platform at all exterior doors PASS Handrail required with 4 or more risers PASS Guards at stairs, decks and patios 30 inches or more above grade PASS Guard at stairwell at 34 inches or more PASS Handrail termination at newell post or wall PASS Interior and exterior handrails 34" to 38" high PASS Grade away from foundation sloping 6 inches in the first 10 feet PASS 6 inch clearance to sill plate from grade PASS Interior privacy doors and trim required PASS Exterior main entrance door min 36" wide PASS Bathroom and Kitchen floors must be watertight PASS Low flow toilet 1.3 gallon per flushing cycle PASS Safety glazing required within 5 feet of tub and shower PASS Smoke detectors are min of 3 feet horizontally from opening of bathroom PASS Smoke Detectors are required on every level and in every bedroom PASS Smoke Detectors are required outside every bedroom area PASS Smoke Detectors have battery back up PASS Smoke detectors are interconnected PASS Carbon monoxide detectors are within 10 ft of all sleeping areas PASS Carbon monoxide detectors are required in bedrooms with gas appliances PASS Carbon monoxide detectors are required on all levels with gas appliances (i.e. furnace) PASS Bathroom fans required, if no window PASS All plumbing fixtures complete PASS Backflow preventors where required PASS Foundation insulation to basement floor PASS Energy sticker on elec. panel, R values and heating systems FAIL All Hot Water Systems R 3 on 3/4 inches or larger piping PASS Duct work sealed properly PASS Intake openings for HVAC PASS HRV or ERV installed per bedroom requirements PASS Emergency egress window below grade 44 inches max from sill height from basement floor PASS Furnace shut off within 30 ft. or within line of site PASS Furnace and hot water heater operating PASS Pressure relief valve, heat trap, water temp 110 degrees or less PASS Pressure relief valve down spout within 6 inches of floor PASS Basement stairs closed rise greater than 4 inches PASS Basement wall insulation R- value verified PASS Basement egress: 5 s.f. window w/sill or Bilco door PASS Jack posts in basement lagged at top and bottom PASS Fin elect; energy saving light bulbs 90 percent PASS Arc fault breaker habitable spaces PASS Flex gas pipe bonding PASS As built septic system FAIL Truss ID signage installed at electrical meter PASS Ok to issue certificate of occupancy PASS Charles Dyer Code Enforcement Officer