ChecklistReport002-01-24 021740
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0715-2023 Case Module: Permit
Inspection Date: February 01, 2024 Inspection Status: Passed
Inspector: Charles Dyer Inspection Type: Residential Final
Job Address: 9 RIDGEWOOD CT
, Parcel Number:
Contact Type Company Name Name
N/A
Contractor PATTEN PROPERTY DEVELOPMENT, LLC
Granted Permission PATTEN PROPERTY DEVELOPMENT, LLC
Primary Owner N/A
Primary Owner N/A
Checklist Item
Status
Building Inspector notes for partial alteration of basement/full bath and sleeping area. PASS
4 inch min building number address
visible from road PASS
Chimney height, B vent, direct vent
location FAIL
Chimney rain cap installed FAIL
Fresh air intake PASS
Fresh air supply 3 feet from grade PASS
3 inch plumbing vent through roof,
minimum 18 inches PASS
Outside spigots have air gap PASS
Roof complete PASS
Exterior finish complete PASS
Platform at all exterior doors PASS
Handrail required with 4 or more risers PASS
Guards at stairs, decks and patios 30
inches or more above grade PASS
Guard at stairwell at 34 inches or more PASS
Handrail termination at newell post or wall PASS
Interior and exterior handrails 34" to 38"
high PASS
Grade away from foundation sloping 6
inches in the first 10 feet PASS
6 inch clearance to sill plate from grade PASS
Interior privacy doors and trim required PASS
Exterior main entrance door min 36" wide PASS
Bathroom and Kitchen floors must be
watertight PASS
Low flow toilet 1.3 gallon per flushing
cycle PASS
Safety glazing required within 5 feet of
tub and shower PASS
Smoke detectors are min of 3 feet
horizontally from opening of bathroom PASS
Smoke Detectors are required on every
level and in every bedroom PASS
Smoke Detectors are required outside
every bedroom area PASS
Smoke Detectors have battery back up PASS
Smoke detectors are interconnected PASS
Carbon monoxide detectors are within 10
ft of all sleeping areas PASS
Carbon monoxide detectors are required
in bedrooms with gas appliances PASS
Carbon monoxide detectors are required
on all levels with gas appliances (i.e.
furnace) PASS
Bathroom fans required, if no window PASS
All plumbing fixtures complete PASS
Backflow preventors where required PASS
Foundation insulation to basement floor PASS
Energy sticker on elec. panel, R values
and heating systems FAIL
All Hot Water Systems R 3 on 3/4 inches
or larger piping PASS
Duct work sealed properly PASS
Intake openings for HVAC PASS
HRV or ERV installed per bedroom
requirements PASS
Emergency egress window below grade
44 inches max from sill height from
basement floor PASS
Furnace shut off within 30 ft. or within line
of site PASS
Furnace and hot water heater operating PASS
Pressure relief valve, heat trap, water
temp 110 degrees or less PASS
Pressure relief valve down spout within 6
inches of floor PASS
Basement stairs closed rise greater than
4 inches PASS
Basement wall insulation R- value verified PASS
Basement egress: 5 s.f. window w/sill or
Bilco door PASS
Jack posts in basement lagged at top and
bottom PASS
Fin elect; energy saving light bulbs 90
percent PASS
Arc fault breaker habitable spaces PASS
Flex gas pipe bonding PASS
As built septic system FAIL
Truss ID signage installed at electrical
meter PASS
Ok to issue certificate of occupancy PASS
Charles Dyer
Code Enforcement Officer