INSPECTION WORKSHEET 03112024 INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: RC-0421-2023 Case Module: Permit Inspection Date: March 11, 2024 Inspection Status: Reinspect Inspector: Mark Smith Inspection Type: Residential Final Job Address: 7 Quarry Crossing , Parcel Number: Contact Type Company Name Name Owner N/A Melissa Lambert Applicant N/A Tobias Kipp Checklist Item Status Building Inspector notes 3/11/24 partial approval for final inspection of single family dwelling. Approved for temporary Certificate of Occupancy only. please complete the items listed below and call for recheck - complete work at the side and front porches and call for framing inspection. - complete exterior trim and siding. - pressure release valve at hot water heater should extend to 6” above finished floor. PASSN/O 4 inch min building number address visible from road Fresh air intake PASS Fresh air supply 3 feet from grade PASS 3 inch plumbing vent through roof, minimum 18 inches PASS Roof complete PASS Exterior finish complete FAIL Platform at all exterior doors PASS Handrail required with 4 or more risers PASS Guards at stairs, decks and patios 30 inches or more above grade PASS Guard at stairwell at 34 inches or more PASS Window guards req at less than 2' above floor and 6' above grade PASS Guard at deck and porches 36" or more in height PASS Handrail termination at newell post or wall PASS Interior and exterior handrails 34" to 38" high PASS Wood deck 2 feet or more from grade diagonal bracing required FAIL 4 or more Deck Joist Ledger Connections starting 24" from each end FAIL Deck ledgers to be bolted per code FAIL Grade away from foundation sloping 6 inches in the first 10 feet PASS 6 inch clearance to sill plate from grade PASS Gas meter and or regulator shut off 12 inches min above grade PASS HVAC vent terminal 10 feet from lot line and openings PASS Dryer duct max length 35 feet or per manufacturer's instructions PASS Interior privacy doors and trim required PASS Exterior main entrance door min 36" wide PASS Bathroom and Kitchen floors must be watertight PASS Low flow toilet 1.3 gallon per flushing cycle PASS Smoke detectors are min of 3 feet horizontally from opening of bathroom PASS Smoke Detectors are required on every level and in every bedroom PASS Smoke Detectors are required outside every bedroom area PASS Smoke Detectors have battery back up PASS Smoke detectors are interconnected PASS Carbon monoxide detectors are within 10 ft of all sleeping areas PASS Carbon monoxide detectors are required in bedrooms with gas appliances PASS Carbon monoxide detectors are required on all levels with gas appliances (i.e. furnace) PASS Bathroom fans required, if no window PASS All plumbing fixtures complete PASS All Hot Water Systems R 3 on 3/4 inches or larger piping PASS Duct work sealed properly PASS Intake openings for HVAC PASS Furnace shut off within 30 ft. or within line of site PASS Furnace and hot water heater operating PASS Pressure relief valve, heat trap, water temp 110 degrees or less PASS Pressure relief valve down spout within 6 inches of floor FAIL Jack posts in basement lagged at top and bottom PASS Fin elect; energy saving light bulbs 90 percent PASS Arc fault breaker habitable spaces PASS Flex gas pipe bonding PASS Truss ID signage installed at electrical meter FAIL Ok to issue temporary certificate of occupancy PASS Ok to issue certificate of occupancy Mark Smith Code Enforcement Officer